Buy One, Get Two for Free: Simultaneous Knee T2 Mapping and Morphological Analysis On Synthetic Images Using GRAPPATINI

Similar documents
BIOMARKER DISCOVERY IN LOCALLY ADVANCED CERVICAL CANCER: IQ-EMBRACE PETRA VAN HOUDT, JESPER KALLEHAUGE, UULKE VAN DER HEIDE, KARI TANDERUP MARCH 23,

CQIE MRI PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

Press Presse Press Presse

Background. Magnetic Resonance Spectroscopy (MRS) non invasively measures metabolite concentrations

Purpose. Methods and Materials

Time-resolved 4D TWIST MR angiography of congenital heart and vessel anomalies: image quality and added diagnostic value compared to 3D MRA

Arterial Spin Labeling (ASL)

Precision in Quantitative Imaging: Trial Development and Quality Assurance

Clarity CT Technology

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

Life Sciences Reporting Summary

Magnetic Resonance Imaging at 7T in Glasgow. A unique opportunity!

Accelerating Clinical MRI in the 21 st Century

Generating ROI with Advanced PET and Diagnostic CT Imaging

First Experiences with the World s First MAGNETOM Vida

Do we need MRI quality assurance: experience from a multiunit imaging center with 14 MRI systems

Small footprint giant steps. MAGNETOM C! with syngo MR A30.

Magnetic Resonance Spectroscopy from fundamental developments to improved noninvasive diagnosis and characterisation of children s brain tumours.

2018 REVIEW CATEGORIES

Introduction: what do we mean by Quantitative MRI?

Quantitative biomarker for clinical decision making

MAGNETOM Skyra: The Mannheim Perspective

The Unique, New MRI Philips Ingenia 3 Tesla is now in Ayios Therissos! The first-ever digital broadband MR system has been installed in Ayios

PRINCIPLES OF CT AND MR IMAGING Marc-André d Anjou, DMV, DACVR Faculty of Veterinary Medicine, University of Montreal Saint-Hyacinthe, Quebec, Canada

Correspondence should be addressed to Yinghua Zhao;

CQIE PET PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

siemens.com/avanto MAGNETOM Avanto The landmark in 1.5T imaging.

Handzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014

Physicists Quality Control for MR Equipment

ClinScan. think forward. Small Animal MRI Solution for Molecular Imaging and Translational Research. Preclinical MRI

Power-class. Expect more performance. MAGNETOM Symphony.

I-class. All together a better way to work. MAGNETOM Avanto.

Magnetic Resonance Imaging (MRI) Safety for Boston Scientific Products. 1. WALLSTENT Iliac Endoprosthesis with Unistep Plus Delivery System

Creating a More Efficient Workflow for Reading High-Volume CT and MR Studies

Innovations in medical imaging:

A pilot study of short T2* measurements with ultrashort echo time imaging at 0.35 T

High quality and fast scanning with Compressed SENSE at KCH

Computed tomography. High. performance. no trade-offs. Philips Ingenuity CT family

Progress Towards an International Image Quality Monitoring Framework for Quantitative Imaging

Quality Control Concerns for New Generations of CT, MRI, & PET

AAPM Scientific Meeting Imaging Symposium. State of the Art in Quantitative Imaging CT, PET and MRI. Which Imaging Modality is the Most Quantitative

Optimizing Radiation Dose for Samsung GC85A

Imaging Biomarkers: Paradigm Change Towards Personalized Medicine

Table of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26

DCE MRI Team Activity. Gudrun Zahlmann, Edward Jackson, Sandeep Gupta

Optimisation in CT. A case for shared approach. Stephen J. Golding University of Oxford

Quantitative Imaging Biomarker DCE - MRI

Balancing versatility and value Introducing Optima MR T

GE Healthcare. Introducing Discovery MI DISCOVERY MI

Magnetic Resonance Imaging of Short-T2 Tissues with Applications for Quantifying Cortical Bone Water and Myelin

C-arm CT Perfusion Imaging in the Interventional Suite

Siemens Healthineers A paradigm shift in MRI and CT

Rapid Field-Cycling MRI using Fast Spin- Echo

Jeffrey T. Yap, Ph.D. Dana-Farber Cancer Institute Brigham & Women s Hospital Harvard Medical School

High-Speed 3T MR Spectroscopic Imaging of Prostate With Flyback Echo-Planar Encoding

Medical Engineering (Biomedical Engineering, Clinical Engineering, Bioengineering) Medical Materials Science (Biomaterials) Dental Materials Science

GE Healthcare. Introducing Veo * on Discovery * CT750 HD Great care by design

Accuracy, Precision and Measurement Validation

Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose

Declaration of Relevant Financial Interests or Relationships

Disclaimer. Fat in the body. Outline. Managing fat in MRI: a technical perspective

Delivering the most exciting equation in MRI. MAGNETOM Verio. Answers for life.

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening

CHAPTER 2 INTERFERENCE ISSUES OF RFID IN MRI AND CT SCAN

PET in clinical trials

UPICT template structure as modified by QIBA VolCT Technical Committee June 25, 2009

Propel your imaging abilities into the future.

A.K. Because edema should have attenuation of around zero Hounsfield units. D.A.B. Around water? A.K. Around water, yes.

Pre-clinical and postmortem diffusion MRI

Artifacts Caused by Eddy Current in Diffusion MRI

Preclinical MRI. Solutions for Small Animal Imaging. Molecular Imaging

Future bound. Philips Ingenuity Core

QIBA Profile: Small Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening

2017 ACR Computed Tomography Quality Control Manual FAQS

To Whom It May Concern:

MRI Protocols in Experimental Stroke. Xenios Milidonis Centre for Clinical Brain Sciences The University of Edinburgh

IMV 2006 CT Market Summary Report Featuring results from 2,565 hospital and non-hospital CT imaging sites in the United States

BODY MRI PROTOCOLS 3T

Hashem Almahmoud 1 Kang Wang 1 Brent Neuschwander-Tetri 2 Elhamy Heba 1 Michael S. Middleton 1 Albert Hsiao 1 Claude B. Sirlin 1

Design and Preliminary Clinical Studies of an MRI-Guided Transrectal Prostate Intervention System

Diagnostic Medical Image Processing

SELF-REGULATORY INITIATIVE FOR MEDICAL IMAGING EQUIPMENT MAGNETIC RESONANCE MEASUREMENT OF ENERGY CONSUMPTION

Meet your new business partner. MAGNETOM ESSENZA. Answers for life.

Press. Innovative systems for radiology from Siemens. Healthcare Erlangen, March 3, ECR 2016 in Vienna: Hall X5, Booth 12

Marco Essig MD, Department of Radiology, German Cancer Research Center, Heidelberg, Germany.

The Role of Tomosynthesis Imaging at Our Institute and X-ray Dose Optimization

Recent clinical advances and applications for medical image segmentation

WHY QIBA: MR SPECIFICS

Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT

8/1/2018. Optimization Strategies for Pediatric CT Imaging. Educational Objectives. Brain CT

Supplementary Material Cohort Description

CTA Throughout the Ages

CALIFORNIA LAW AND RESPONSE + FIVE QUICK LESSONS ON CT DOSE OPTIMIZATION

HHSN C Quantitative Imaging Biomarkers Alliance (QIBA)

Magnetic Resonance Histology for Morphologic Phenotyping

Construction and evaluation of a quantitative arterial spin labeling brain perfusion template at 3T

MRI Systems Market to 2018

QIN: Overview of Scientific Challenges

Transcription:

Buy One, Get Two for Free: Simultaneous Knee T2 Mapping and Morphological Analysis On Synthetic Images Using GRAPPATINI Marion Roux, Tom Hilbert, Jean-Baptise Ledoux, Fabio Becce, Tobias Kober, Patrick Omoumi 1 - Department of Radiology, University Hospital (CHUV), Lausanne, 2 - Advanced Clinical Imaging Technology (HC CMEA SUI DI BM PI), Siemens Healthcare AG, Lausanne 3 - LTS5, École Polytechnique Fédérale de Lausanne, Lausanne

Background Most commonly used contrasts to assess morphological joint abnormalities are [1]: Intermediate-weighted TSE (IW) T2-weighted TSE (T2w) Quantitative T2 mapping gained interest recently Clinical Relevance: quantitative T2 is a good biomarker of early degenerative disease of cartilage and meniscus [2-4] The acquisition of both morphological and quantitative sequences is however time consuming, hindering their spread in clinical use. [1] Huang M et al. Radiology 2014;273:S1-22. [2] Kijowski R, et al. Radiology 2013;267:503-13. [3] Zarins ZA et al. Osteoarthritis Cartilage 2010;18:1408-16. [4] Rauscher I et al. Radiology 2008;249:591-600.

The GRAPPATINI sequence Standard sequences + IW + T2 T2 mapping GRAPPATINI sequence + T2 mapping IW + T2

Objective Validation of : (1) T2 values phantom experiment (2) image quality quantitative and qualitative assessment 5 healthy volunteers in comparison to the consecutive acquisition of morphological and quantitative sequences

1) Phantom experiments Methods Validation of the T2 estimation with GRAPPATINI Phantom: Tubes filled with different concentrations of agar and gadolinium Experiment: Same hardware and protocols (MESE and GRAPPATINI) used as in in-vivo experiments Reference: Low resolution single slice, single spin-echo sequence

1) Phantom Experiments Results MESE > GRAPPATINI > SSSE (stimulated echoes) Agreement MESE GRAPPATIN I [8] Maier, Cynthia F. et al. JMRI 17, no. 3 (2003): 358-364.

2) In vivo experiments Methods Single-center prospective study, performed from September 2015 to January 2016 5 healthy volunteers (3 males, age 30.2±3.3 years) 3T (MAGNETOM Skyra, Siemens Healthcare, Germany), 15- channel knee coil Acquisition of the GRAPPATINI sequence Generation of additional synthetic contrasts with TE=34ms and TE=80ms Acquisition of standard morphological TSE images IW (TE=34ms) and T2w (TE=80ms)

2) In vivo Methods MRI protocol 3T (MAGNETOM Skyra, Siemens Healthcare, Germany) 15-channel knee coil All sequences were acquired in the sagittal plane.

2) In vivo Methods Analysis Comparison of synthetic morphological images versus conventional TSE images Quantitative analysis : SNR, CNR Qualitative analysis (2 radiologists blinded to employed sequence, Five-grade scale): Global image quality Image quality of each of the following anatomical structures: cartilage, menisci, cruciate ligaments, bone marrow, muscle, joint fluid, quadricipital and patellar tendons Visual image contrast Visual noise Artifacts -2: first image significantly worse than second, -1: moderately worse, 0: no difference, +1: moderately better, +2: significantly better

?? Synthetic Image (TE=34 ms) Standard IW TSE (TE=34 ms)

2) In Vivo Experiments Results Quantitative Analysis No significant difference in SNR and CNR SNR : average SNR = 9.9 for both synthetic and conventional sequences, p=0.99 CNR : cartilage/fluid: 6.2 vs. 6.6, p=0.62 meniscus/fluid: 11.3 vs. 11.6, p=0.81

2) In Vivo Experiments Results Qualitative Analysis No difference in global image quality or of any of the anatomical structures that were evaluated average score of 0, 95%CI=[0; 0.4] Artefact scores were slightly higher for the synthetic sequences average of -0.1, 95%CI=[-0.002; -0.6] Visual noise and contrast were slightly better for the synthetic sequences average score of 0.1 for both, 95%CI=[0.002; 0.6]

Limitations Number of included patients (volunteers) Implication in diagnosis imaging

Conclusion T2 map, IW and T2w images can be acquired with one GRAPPATINI sequence in 6.22 min instead of 12.13 min (sum of the acquisition times obtained with the standard techniques) GRAPPATINI provides Accurate T2 values Synthetic IW and T2w images quantitatively and qualitatively similar to conventional TSE images

Buy One, Get Two for Free: Simultaneous Knee T2 Mapping and Morphological Analysis On Synthetic Images Using GRAPPATINI Marion Roux, Tom Hilbert, Jean-Baptise Ledoux, Fabio Becce, Tobias Kober, Patrick Omoumi 1 - Department of Radiology, University Hospital (CHUV), Lausanne, 2 - Advanced Clinical Imaging Technology (HC CMEA SUI DI BM PI), Siemens Healthcare AG, Lausanne 3 - LTS5, École Polytechnique Fédérale de Lausanne, Lausanne Thank You

The GRAPPATINI sequence T2 Map Acquisition: 10-fold undersampled multi-echo spin-echo sequence (MESE) T2 Map Reconstruction: GRAPPATINI [7]: Subsequent application of parallel imaging (GRAPPA) [5] and model-based reconstruction (MARTINI) [6] Synthetic T2 weighted Images: Applying the forward signal Model to simulate TSE contrast with arbitrary echo-time TE [5] Griswold, Mark A., et al. MRM 47.6 (2002): 1202-1210. [6] Sumpf, Tilman J., et al. JMRI 34.2 (2011): 420-428. [7] Hilbert, Tom, et al. ISMRM 22.4077 (2014).