SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

Similar documents
SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM WINDOWS

DETENTION / SECURITY WINDOWS SECTION 08660

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SECTION STAINLESS STEEL WALL PANELS

STEEL WINDOWS & DOORS SECTION 08510

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

4600 Series Specifications (Section 08520)

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

SECTION ALUMINUM WINDOWS

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

CTB Commercial Aluminum Window

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

SILVER LINE BUILDING PRODUCTS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

AMBICO Limited Section and BLAST RESISTANT STEEL WINDOW FRAME ASSEMBLIES Page 1

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

SECTION ROOFING AND SIDING PANELS

HOTEL SPECIFICATION SECTION 08100

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

SECTION Coiling Counter Shutters

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION Coiling Counter Shutters

SECTION VINYL (PVC) WINDOWS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

A. Access doors and frames are part of an access door and frame allowance.

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Heavy Commercial / Architectural Projected Windows Series L900T AW150

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

Corium Brick Rainscreen System Specifications

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

SECTION DETAILS (MECHANICALLY ASSEMBLY)

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

SECTION ACCORDION FOLDING PARTITIONS

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing.

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION ROLLING STEEL DOORS

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

Series 8100 Horizontal Slider HS-C x 1524 ( 71 x 60 )

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION BLAST RESISTANT WINDOWS

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION COILING COUNTER DOORS

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

SECTION ORNAMENTAL ALUMINUM FENCING

HORIZONTAL SLIDER SERIES 700. Main Frame Depth: 2 3/4 Glazing Thickness (Maximum): 5/8 Thermal Break:

SECTION K. Section Millwork: Wood trim other than furnished by door and frame manufacturer

SECTION EXTERIOR SUN SHADES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

ADDENDUM # 1 To: RFP for: Blanco Store Fronts, Lighting & Mechanical Improvements

MPG Series 2250T Thermally Broken Aluminum Window

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

SECTION SHOWER AND DRESSING COMPARTMENTS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

SECTION ALUMINUM WINDOWS

SECTION Coiling Doors and Grilles Model 4320

SECTION 2 DIVISION 05 METALS

Hollow Metal Doors and Frames

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

.1 [Non-rated] [fire rated] pressed steel, lead-lined steel frames. .2 [Non-rated] [fire rated] hollow metal, lead-lined doors [and panels].

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

PROJECT IN SERIES 1300 NARROW SIGHT LINE AAMA/WDMA/CSA 101/I.S.2/A Structural Performance:

SECTION ALL ULTREX DOUBLE HUNG WINDOW

SECTION ORNAMENTAL WELDED STEEL FENCING

WESTECK WINDOWS and DOORS

SECTION ACCESS DOORS AND FRAMES

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION STEEL WINDOWS

SECTION EXTERIOR GRILLS AND SCREENS

SERIES /8 HORIZONTAL SLIDING WINDOW (CW30)

Transcription:

SECTION 08510 STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit. PART 1 GENERAL 1.1 SECTION INCLUDES A. Fire Rated Steel Windows (Horizontal Slider) 45-Minute UL Labeled B. Fire Rated Steel Windows (Horizontal Slider) 60-Minute UL Labeled 1.2 RELATED SECTIONS A. Section 08800 Glass, Glazing, and Glazing Materials 1.3 REFERENCES A. ASTM A 569-(1991a; R 1993) Steel, Carbon (0.15 Maximum, Percent), Hot-Rolled Sheet and Strip Commercial Quality B. ASTM A 653-(1994) Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process C. ASTM B 633-(1985; R 1994) Electrodeposited Coatings of Zinc on Iron and Steel D. ASTM B 766-(1986; R 1993) Electrodeposited Coatings of Cadmium E. ASTM E 283-(1991) Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors Under Specific Pressure Differences Across the Specimen F. ASTM E 330-(1990) Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference G. ASTM E 547-(1993) Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential H. ASME B18.6.3- (1972; R 1991) Machine Screws and Machine Screw Nuts I. ASME B18.6.4- (1981; R 1991) Thread Forming and Thread Cutting Tapping Screws and Metallic Drive Screws (Inch Series) J. NFPA 80-(2007) Fire Doors and Windows K. NFPA 101-(2006) Safety to Life from Fire in Buildings and Structures L. UL9-Fire Tests of Window Assemblies M. File No. R13157-D.V. Fyre-Tec Classification 1.4 PERFORMANCE REQUIREMENTS 08510-1

A. Horizontal sliding steel windows shall conform to the HS-C30 voluntary specifications in AAMA/NWWDA 101/I.S.2-97 and be designed to meet the following performance requirements. Fire-rated windows shall bear the Underwriters Laboratories, Inc. label including the manufacturer s file number for the indicated rating. 1. Structural Performance: Structural test pressures on window units shall be for positive load (inward) and negative load (outward) in accordance with ASTM E 330 at a static pressure of 45 PSF. After testing, there shall be no glass breakage, permanent damage to fasteners, hardware parts, support arms or actuating mechanisms or any other damage which could cause window to be inoperable. There shall be no permanent deformation of any main frame, sash or ventilator member in excess of the requirements established by AAMA/NWWDA 101/I.S.2-97 for the window types specified in this section. 2. Air Infiltration: Air infiltration shall not exceed.3 SCFM per square foot of window area at a static air pressure difference of 1.57 PSF as established by AAMA/NWWDA 101/I.S.2-97 when tested in accordance with ASTM E 283. 3. Water Resistance: When tested in accordance with ASTM E 547, there shall be no water leakage at a static air pressure difference of 4.5 PSF. B. Fire Protective: Fire protective rating shall meet requirements established by ASTM E 163 and as tested and classified by Underwriters Laboratories Inc, in accordance with UL-9. Products shall meet the requirements of Underwriters Laboratories Inc. The Listing Mark of UL on the product will be accepted as evidence of compliance. C. Life Safety Criteria: Windows shall conform to NFPA 101 Life Safety Code when rescue and/or second means of escape are indicated. 1.5 SUBMITALS A. Manufacturer s descriptive data and catalog cut sheets. B. Drawings indicating elevations of windows, rough-opening dimensions for each type and size of windows, section details, fastenings, methods of installation and anchorage, connections with other work, type of wall construction, method of glazing, types and locations of operating hardware, mullion details, weather-stripping details, screen details, and window schedules showing locations of each window type and indicting compliance with fire safety code, where required. C. Manufacturer s preprinted installation instructions and cleaning instructions. D. Manufacturer s standard color samples of painted finishes. 1.6 QUALITY ASSURANCE A. Installer Qualifications: Experienced in performing work of this section who has specialized in installation of work similar to that required for this project. B. Manufacturer s Qualifications: A firm with not less than 10 years experience in manufacture of similar type steel windows. 1.7 DELIVERY, STORAGE AND HANDLING A. Delivery: 08510-2

1. Manufacturer s original, unopened, undamaged containers, identification labels intact. Inspect for damage upon delivery. 2. Handle and store products according to manufacturer s recommendations. B. Storage and Protection: 1. Store materials protected from exposure to harmful weather conditions and at temperature and humidity conditions recommended be manufacturer 2. Store windows to prevent damage or marring of finish. Store in shipping containers under cover on building site. 1.8 PROJECT CONDITIONS A. Verify actual openings by field measurements before fabrication, show recorded measurements on shop drawings. B. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays. 1.9 WARRANTY A. Manufacturer s standard warranty to be 3 years from the date of delivery. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Series 900 Horizontal Sliding Windows as manufactured by D.V. Fyre-Tec, Inc.; 701 Centennial Road; Wayne, NE 68787; Tel: 1-800-377-3261; Fax; 1-402-375-4261; Web: www.fyre-tec.com; Email; info@fyre-tec.com. B. Architect approved equal. 2.2 STEEL WINDOW TYPES A. Horizontal sliding steel windows shall be designed for inside field glazing, and for glass types scheduled on drawings or otherwise specified. Units shall be complete with glass and glazing provisions to meet requirements of paragraph WINDOW PERFORMANCE. Glazing material shall be compatible with steel, and shall not require painting. B. Fire-rated windows shall conform to UL-9 and shall be labeled with a 3/4 - hour fire-test rating as specified in the window schedule. Units shall be designed and fabricated to meet glass sizes, window sizes, and opening dimensions established by NFPA 80. Hardware shall conform to NFPA 80 requirements. All operable fire-rated windows are to be self-closing and latching by means of a heat activated fusible link operator. C. Fire-rated windows shall conform to UL-9 and shall be labeled with a 1- hour fire-test rating as specified in the window schedule. Units shall be designed and fabricated to meet glass sizes, window sizes, and opening dimensions established by NFPA 80. Hardware shall conform to NFPA 80 requirements. All operable fire-rated windows are to be self-closing and latching by means of a heat activated fusible link operator. D. Optional automatic closure device to be activated by heat rise, or by a fire or smoke alarm, computer or other electrical signal. 24 or 110 volt actuation signal required. 2.3 MATERIALS 08510-3

A. Steel Frames and Inserts 1. Steel frames and inserts shall be fabricated from roll-formed galvanized lock-forming quality steel per ASTM A 653. 2. Frame and insert corners shall mitered and welded. Integral muntins where required shall be galvanized roll-formed material fitted and welded. 3. Operable insert/sash shall be supported on two field adjustable roller trucks consisting of corrosion resisting steel with integral ball bearing rollers. Rollers are to supported and operate on a stainless steel track. B. Installation Kits 1. Provide attachable fin installation kits for all windows. 2. Provide subframe installation kits for all windows. C. Weather Stripping 1. Weather-stripping for the inserts shall be designed to meet water penetration and air infiltration requirements specified under paragraph WINDOW PERFORMANCE, and shall be manufactured of material compatible with steel and resistant to weather. Weather-strips shall be factory applied and easily replaced in the field. D. Screens 1. Insect screens, if required, shall be steel window manufacturer s standard design, and shall be provided where scheduled on drawings. Insect screens shall be fabricated of roll formed galvanized steel frames and (18x16) plastic coated glass conforming fiber mesh screening conforming to ASTM D 3656. E. Formed Component Parts 1. Formed component parts shall be hot-rolled sheet steel conforming to ASTM A 569, commercial quality with a minimum of 0.15 percent carbon. 2. Sheet steel shall be zinc coated (galvanized) by the hot-dip process in accordance with ASTM A 653 or ASTM A 924. F. Screws and Bolts 1. Screws and bolts shall conform to ASTM B 766, ASME B18.6.3 and ASME B18.6.4. G. Fasteners 1. Fastening devices shall be window manufacturer s design made from cadmium-plated steel, zinc-plated steel, nickel/chrome-plated steel or magnetic stainless steel. H. Window Anchors 1. Anchors for installing windows shall be stainless steel or hot-dip zinc coated steel conforming to ASTM A 123. I. Glass and Glazing 1. As specified in Section 08800. 08510-4

2.4 FABRICATION 2. Traditional wire glass Misco or Baroque (3/4 hour rated) 3. Standard clear ceramic glass (1 hour rated) 4. Premium clear ceramic glass (1 hour rated) 5. Safety laminated premium clear ceramic glass CPSC16CFR1201 Cat I & II (1- hour rated) 6. Insulated glass units. A. Fabricate windows in accordance with approved shop drawings. B. Frame sections shall be one piece sections with corners mitered, welded and dressed smooth. C. Required muntins shall be securely welded to the frame members and at all intersections. D. All windows shall be designed for inside glazing. E. All windows shall be factory glazed with UL labeled glass meeting or exceeding the hourly rating required for the frame label. Individual lites shall display a UL label permanently affixed and in accordance with the requirements of the International Building Code and NFPA 80. 2.5 FINISHES A. Prime Coat 1. Steel windows, fins, mullions, cover plates and associated parts shall be cleaned, pretreated with iron phosphate and factory painted manufacturer s standard primer coat in a dry film thickness of not less than 0.025 mm (1.0 mil). B. Finish Coat Manufacturer s Standard Color 1. Steel windows, fins, mullions, cover plates and associated parts shall be cleaned, pretreated with iron phosphate and factory powder coated and cured with a manufacturer s standard color in a dry film thickness of not less than 0.050 mm (2.0 mil). C. Finish Coat Specified Color Match 1. Steel windows, fins, mullions, cover plates and associated parts shall be cleaned, pretreated with iron phosphate and factory coated with baked alkyd enamel or powdercoat with a dry film thickness of not less than 0.050 mm (2.0 mil). PART 3 EXECUTION 3.1 EXAMINATION A. Window openings shall conform to details and dimensions shown on the approved shop drawings. B. Notify the Architect immediately of conditions that may adversely affect the window installation. Correct conditions prior to installing windows 3.2 INSTALLATION 08510-5

A. Steel windows shall be installed in accordance with approved shop drawings and manufacturer s approved recommendations. B. Fire-rated windows shall be installed in compliance with NFPA 80 and NFPA 101. C. Steel surfaces in close proximity with masonry, concrete, wood, and dissimilar metals other than stainless steel, zinc, cadmium, or small areas of white bronze shall be protected from direct contact. D. Verify that weep features at the bottom of the sills are opened at least 1/8 x 1. Failure to do so may lead to premature finish failures and void warranty. E. The completed window installation shall be watertight. 3.3 ADJUSTING AND CLEANING A. Steel window finish and glass shall be cleaned on interior and exterior sides in accordance with window manufacturer s recommendation. Alkaline, abrasive or brick wash agents shall not be used. B. Operable sash shall be adjusted per manufacturer s instruction to provide minimal operating force. 3.4 PROTECTION A. Protect installed products and finished surfaces from damage during construction. B. Touch-up any abraded surface of the window finish with air dry paint furnished by the window manufacturer. -- END OF SECTION SPEC_900 11-2017 08510-6