Agilent 1220 Infinity LC Mobile Upgrade Kit

Similar documents
Agilent Enhancer Cell

Agilent 11716A/C Interconnection Kit

U7242A USB3.0 Test Fixture

Agilent High Sensitivity DNA Kit Guide

Agilent 7696A Sample Prep WorkBench

Agilent 490 Micro GC Biogas Analyzers

E-Series Installing E-Series U Cabinet

Agilent Technologies 11752D/E Option K01 Connector Gage Kit. User s Guide

Carbon Canister Vapor Polisher

Agilent G2615A Bar Code Reader

Mounting systems for solar technology

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

Bravo Platform Unpacking Guide

Agilent RNA 6000 Nano Kit Guide

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Operation and Service Manual

General Safety Information

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

DRYWALL DOLLY 900 LB. CAPACITY

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Agilent 16034E Test Fixture

VERsacourt LED Light System Installation Instructions

NetShelter. Four-Post Rack. Installation and Quick-Start Manual

HP 3-7U Quick Deploy Rail System Installation Instructions

Conair Thermolator. Stack Rack. (Temperature Control Unit -TCU) U S E R G U I D E UGH

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

LOAD RAMP 1000 LB. CAPACITY

MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316

HD Firewall Mount 850 all, S/V , C ipd #

Festoon Manual Heavy Duty C-Track

INSTALLATION MANUAL. All Types F Series Rev G

Owner s Manual & Safety Instructions

Preference Slimline 5537 Utility Console I NSTALLATION GUIDE

Agilent 2100 Bioanalyzer. Installation and Safety Guide

PRR. Flush Mount Racking System. Installation Manual

BESTMOVE STANDING TRANSFER AID

Installation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V

Automated Plate Replication

Assembly Instructions Legacy Basic Acoustical Shell

Universal Elevator Mount Owners Manual

Agilent N9330B Handheld Cable & Antenna Tester. Quick Start Tutorial

INSTALLATION MANUAL RECTANGULAR COLUMN

Conergy SolarFamulus II

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

VISE MOUNTED. Model 97359

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

1.0. Post Install Kit. For Use With All Vinyl Railing BOM V1 1/13. Owner's Manual. Assembly and Installation Instructions.

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

TrueClean ToteTilter TM

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions

PRB. Flush Mount Racking System. Installation Manual

4 rotary milling table

Agilent InfinityLab Preparative Flow Cells for MWD & DAD

Edge-of-Dock Leveler 'BA' - 'BX' Series. Owner s Manual and Installation Instructions

Agilent 7697A Headspace Sampler

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Troubleshooting Guide 9702 Series

ALUMINUM CURB RAMP. Model 98037

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

Owner s Manual & Safety Instructions

To Contact PS DOORS:

ODYSSEY FLOOR MODEL. Owner s Manual. O-6400-F shown rev 118

Distribution Box INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS UGC

The Racking System Designed By Installers for Installers

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

7 PIECE TUBE FLARING KIT

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.

Agilent 1200 Series Purification System. User Manual

Tourmaster 3-Step Riser

SAVE THESE INSTRUCTIONS

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

GROUND MOUNT INSTALLATION MANUAL

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

Agilent 1260 Infinity RID User Manual. 9 Maintenance

Agilent 16048D Test Leads

You will probably need to perform this procedure in the loading dock area of the building. A fork lift or chain hoist may be needed.

UNIVERSAL UTILITY TRUCK RACK

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

SQ-1 ROOF TRUSS WEG-IT TABLE

Circular Expansion Cement Curing Kit Instruction Manual

MTS Criterion Series 40

SQ-1 INTELLIGENT ROOF

Z5385 V Flying adapter Rigging manual (1.3 EN)

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

Power Distribution Module Replacement Instructions

Saphyr System Safety Guide for Saphyr P/N 60325

Installation Manual. Omnicell. Model: 9102 FB by Fairbanks Scales, Inc. Revision 4 08/16 All rights reserved

General Guidelines. Tools Required. Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC400-V2. Safety

BESTMOVE STANDING TRANSFER AID

Agilent G1674AA Deconvolution Reporting Software (DRS) Solution for Forensic Toxicology

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

MD Power Supply -48Vdc +Bias Tee

Aluminum Headache Rack

Transcription:

Agilent 1220 Infinity LC Mobile Upgrade Kit User Manual Agilent Technologies

Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number G4292-90000 Edition 07/2012 Printed in Germany Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn This product may be used as a component of an in vitro diagnostic system if the system is registered with the appropriate authorities and complies with the relevant regulations. Otherwise, it is intended only for general laboratory use. Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Agilent 1220 Infinity Mobile Upgrade Kit

Contents Contents 1 Introduction 5 Introduction 6 Application Examples 8 2 Site Requirements and Specifications 9 Site Requirements 10 Specifications 14 3 Installation 15 Cautions and Warnings 16 Unpacking the Module 17 Installing the Handle Plate to the 1220 Infinity LC Instrument 20 Installing the Solvent Selection Valve Support 22 Installing the Mobile Solvent Compartment 24 Installing the Column Wire Mesh 27 Installing the Attenuation Unit to the Bench 28 Securing the LC to the attenuation unit 31 4 General Operation Instructions 33 General Operation Instructions 34 5 Consumables 35 Consumables 36 6 Appendix 37 General Safety Information 38 Agilent Technologies on Internet 39 Agilent 1220 Infinity Mobile Upgrade Kit 3

Contents 4 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 1 Introduction Introduction 6 Application Examples 8 This chapter gives an introduction to the use of the mobile kit. Agilent Technologies 5

1 Introduction Introduction Introduction The Agilent 1220 Infinity Mobile LC Solution is an Agilent 1220 Infinity LC with integrated variable wavelength or diode array detector and a mobile upgrade kit that enables transportation. The 1220 Infinity LC Mobile Upgrade Kit consists of functional parts that allows the Agilent 1220 Infinity LC to be mounted into a mobile lab so it can be moved to different locations to access remote measurement sites. The main component is the attenuation unit which acts as a shock absorber to protect the instrument during transit or from influences of operators moving in the mobile lab. A solvent bottle unit keeps the bottles fixed to the instrument. A column wire mesh keeps the column safe in the column heater and the mobile solvent compartment secures the solvent bottles during operation of the instrument. 6 Agilent 1220 Infinity Mobile Upgrade Kit

Introduction 1 Introduction Figure 1 Agilent 1220 Infinity Instrument with attached mobile kit Agilent 1220 Infinity Mobile Upgrade Kit 7

1 Introduction Application Examples Application Examples When samples of interest are locally remote from the lab, the lab has to come to the samples. GC and GC/MS based mobile labs have been around for quite some time but the need for mobile LCs has become a more burning issue recently. Mobile LC applications range from analysis of non-volatile pesticides in environmental and food applications, monitoring of drugs or testing of counterfeit drugs. It can also be used in teaching, when a mobile lab goes to students residing in remote areas. The diode array detector integrated in the Agilent 1220 Infinity LC enables spectra analysis for purity identification and comparison with self-created library data. 8 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 2 Site Requirements and Specifications Site Requirements 10 Specifications 14 This chapter provides information on environmental requirements, physical and performance specifications. Agilent Technologies 9

2 Site Requirements and Specifications Site Requirements Site Requirements Bench Space The attenuation unit has a footprint of 480 mm (18.9 in) in width and 445 mm (17.5 in) in depth. The overall room specified for operation (width x depth x height) of 560 mm (22.1 in) x 665 mm (26.2 in) x 970 mm (38.2 in) already includes the space for a complete 1220 Infinity LC Instrument mounted onto the attenuation unit and considering the necessary room for air circulation, electrical connections and safety area for the possible movement of the instrument on the attenuation unit. For a comfortable handling of the solvent bottles additionally 20 cm (7.9 in) should be kept free above the bottles. See Figure 2 on page 11 for more details. 10 Agilent 1220 Infinity Mobile Upgrade Kit

Site Requirements and Specifications 2 Site Requirements Figure 2 Required space for a 1220 Infinity LC Instrument installed to a mobile upgrade kit (numbers given in mm) Agilent 1220 Infinity Mobile Upgrade Kit 11

2 Site Requirements and Specifications Site Requirements Bench Material and Strength A proper bench must be chosen under the aspect that it must bear the combined weight of the instrument with solvent bottles and the mobile kit. The bench material must be suitable for a proper fastening solution. Fastening Solution Because of the expected varieties in bench material and strength the fastening material is not included in the kit. A suitable fastening solution (screws or bolts) must be chosen to secure the attenuation unit to the bench of the mobile lab. NOTE This solution must be strong enough to withstand the forces that will result from the possible accelerations that can occur in a moving vehicle (app. 2000 N per screw, based on a calculation with 1 G acceleration and the weight of a G4294B). NOTE The head of the chosen screws or bolts must not stand out more than 15 mm on top of the attenuation unit s bottom plate. The attenuation unit comes with four 8.5mm (0.33 in) diameter holes prepared in the lower plate and four 20 mm (0.79 in) diameter holes located directly above them in the top plate. This allows the use of a 14 mm (9/16 in) nut for tightening the screws or bolts. See Figure 3 on page 13 for the layout information of the holes that must be prepared to the bench. 12 Agilent 1220 Infinity Mobile Upgrade Kit

Site Requirements and Specifications 2 Site Requirements Figure 3 Dimensions of the attenuation unit Agilent 1220 Infinity Mobile Upgrade Kit 13

2 Site Requirements and Specifications Specifications Specifications Physical Specifications Table 1 Physical Specifications Type Specification Comments Weight (all parts) Dimensions of the attenuation unit (height x width x depth) 14.2 kg (31.3 lbs) 73 x 480 x 445 mm (2.9 x 18.9 x 17.5 in) See Installing the Attenuation Unit to the Bench on page 28 for more information regarding safety space. Performance Specifications The performance specifications show details about the performed test patterns. Table 2 Performance Specifications Type Specification Comments Vibration Test Outdoor Agilent internal test guidelines 14 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 3 Installation Cautions and Warnings 16 Unpacking the Module 17 Damage to the module 17 Delivery Checklist 18 Installing the Handle Plate to the 1220 Infinity LC Instrument 20 Installing the Solvent Selection Valve Support 22 Installing the Mobile Solvent Compartment 24 Installing the Column Wire Mesh 27 Installing the Attenuation Unit to the Bench 28 Securing the LC to the attenuation unit 31 This chapter provides information on unpacking, checking on completeness, and installation of the mobile kit. Agilent Technologies 15

3 Installation Cautions and Warnings Cautions and Warnings WARNING Personal injury or damage to the system The system is bulky and heavy. Lift the instrument with at least two persons. WARNING Sharp metal edges Sharp-edged parts of the equipment may cause injuries. To prevent personal injury, be careful when getting in contact with sharp metal areas. CAUTION Damage to the system If the handle plate is not fixed precisely, the mobile system may tumble or slide off the bench. Use the handle plate only if it is fixed correctly to the instrument. NOTE Please note that the design of the 1220 Infinity mobile solution is intended for protecting the instrument from influences during transit. Analytical measurement however has to be conducted under stationary conditions. NOTE Operating the 1220 Infinity LC in a mobile lab environment can require special equipment or facilities to comply with local safety regulations (e.g. special solvent waste and storage containers). Please verify that these regulations are met before you operate the 1220 Infinity LC in your mobile lab. 16 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Unpacking the Module Unpacking the Module Damage to the module If the delivery packaging shows signs of external damage, please call your Agilent Technologies sales and service office immediately. Inform your service representative that the instrument may have been damaged during shipment. CAUTION "Defective on arrival" problems If there are signs of damage, please do not attempt to install the module. Inspection by Agilent is required to evaluate if the instrument is in good condition or damaged. Notify your Agilent sales and service office about the damage. An Agilent service representative will inspect the instrument at your site and initiate appropriate actions. Agilent 1220 Infinity Mobile Upgrade Kit 17

3 Installation Unpacking the Module Delivery Checklist Ensure all parts and materials have been delivered with the mobile upgrade kit. The delivery checklist is shown below. Please report missing or damaged parts to your local Agilent Technologies sales and service office. p/n Description G4292-60001 Mobile solvent compartment Includes 4 prefixed bottle holders and 4 Leak Tub brackets to fix it to the module s solvent compartment G4292-60000 Attenuation unit Shock absorbing unit to mount on the Mobile Lab s bench G4292-60003 Handling plate Pre-connected to the Attenuation unit (see Installing the Handle Plate to the 1220 Infinity LC Instrument on page 20 for further instructions) G4292-40000 Column wire mesh To protect the column G4292-00001 SSV support Needs to be installed when a solvent selection valve is installed NOTE The required fastening bolts or screws are not delivered with the mobile upgrade kit and a proper solution must be chosen. See Site Requirements on page 10 for more details. 18 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Unpacking the Module Leak tub brackets Mobile solvent compartment SSV support Handling plate Attenuation unit Figure 4 Mobile Kit Overview Agilent 1220 Infinity Mobile Upgrade Kit 19

3 Installation Installing the Handle Plate to the 1220 Infinity LC Instrument Installing the Handle Plate to the 1220 Infinity LC Instrument WARNING Personal injury or damage to the system The system is bulky and heavy. Lift the instrument with at least two persons. 1 Lay the 1220 Infinity LC Module carefully on its rear plate. NOTE For the G4290B it is necessary either to position the bottom of the instrument slightly free over the bench s edge or to lay it onto the carton box of the solvent compartment. 2 Push on the two lock pins (1) to release the front fixing angles (2) and separate the handling plate (3) from the rest of the attenuation unit. 1 1 3 2 3 2 3 Use the four delivered screws to mount the handle plate to the bottom of the 1220 Infinity LC instrument. The holes for the screws are already prepared in the bottom of the instrument. NOTE Pay attention that the side with the concave cut-out section is orientated to the instrument front. 20 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Installing the Handle Plate to the 1220 Infinity LC Instrument 4 Verify that the screws are fixed and carefully bring the instrument back into the upright position. Agilent 1220 Infinity Mobile Upgrade Kit 21

3 Installation Installing the Solvent Selection Valve Support Installing the Solvent Selection Valve Support When The Solvent Selection Valve Support needs to be installed if a solvent selection valve (SSV) is used with the instrument. Parts required p/n Description G4292-00001 SSV support (delivered as part of the G4292-60000 attenuation unit) Preparations WARNING If SSV is already installed: Unplug the SSV. Clear the solvent compartment. Remove the whole top cover with the SSV still attached to it. Sharp metal edges Sharp-edged parts of the equipment may cause injuries. To prevent personal injury, be careful when getting in contact with sharp metal areas. NOTE When the SSV support is installed, the SSV cannot get attached to the top cover without removing the top cover. 22 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Installing the Solvent Selection Valve Support 1 Take the SSV-Support and slide it into the slits in the metal cover above the gradient valve. 2 If the SSV was already installed: Reinstall the top cover. Connect the SSV. OR If the SSV was not already installed: Remove the top cover. Fix the SSV to the top cover. Reinstall the top cover. Connect the SSV. Agilent 1220 Infinity Mobile Upgrade Kit 23

3 Installation Installing the Mobile Solvent Compartment Installing the Mobile Solvent Compartment Parts required p/n Description G4292-60001 Mobile solvent compartment including 4 special brackets WARNING Sharp metal edges Sharp-edged parts of the equipment may cause injuries. To prevent personal injury, be careful when getting in contact with sharp metal areas. 1 Take out the grey solvent bottle container of the instrument s top cover and attach the 4 leak tub brackets to it (two on each side). Look at the instrument s top and identify the referring spaces (where the arrows in the picture of step 2 on page 25 point to). This is the dedicated position for middle part of the clamps. This information is necessary for a correct positioning of the clamps. It is hard to correct their position once they are installed. 24 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Installing the Mobile Solvent Compartment 2 Now take the leak tub and reinstall it to the top cover. Verify that the leak tub brackets properly hook in underneath the top cover on the instrument s side. Agilent 1220 Infinity Mobile Upgrade Kit 25

3 Installation Installing the Mobile Solvent Compartment 3 Take the mobile solvent compartment and push it into the solvent container. The two metal clips will grip into the solvent container's plastic. On the rear of the mobile solvent compartment is the grounding clamp which needs to hook into the metal sheet between the board extension and the main assembly. Grounding clamp 26 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Installing the Column Wire Mesh Installing the Column Wire Mesh Parts required p/n Description G4292-40000 Column wire mesh 1 Put the column wire mesh with its open side facing to the top into the column heater assembly. 2 Position the column in the Column wire mesh so that it is fixed properly. Agilent 1220 Infinity Mobile Upgrade Kit 27

3 Installation Installing the Attenuation Unit to the Bench Installing the Attenuation Unit to the Bench The bench holding the instrument requires 4 screws or bolts to secure the attenuation unit of the 1220 Infinity Mobile LC Kit to the bench. This fastening material is not provided from Agilent because of the unpredictable situation of bench material and dimension. Tools required Description Wrench (size depending on chosen fastening material) Parts required p/n Description G4292-60000 Attenuation unit Preparations NOTE Prepare the appropriate fastening material (4 proper screws or bolts) and corresponding tools for attaching the attenuation unit onto the desired surface. Four 8.5 mm (0.33 in) holes are prepared on the lower plate of the attenuation unit and four equivalent 20 mm (0.79 in) holes in the top plate above allowing the use of a 14mm nut. The screws or bolts must withstand a maximum drag force of 2000 N and their head should not stand out more than 15 mm out of the lower plate. See figure in step 2 on page 29 for the layout location of these holes that must be provided in the bench top. The fastening material is not part of this kit. 28 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Installing the Attenuation Unit to the Bench 1 Identify the final position of the instrument on the bench according to the specifications given below. 2 Drill the 4 holes in the bench. Either use the attenuation unit as a model or prepare the holes according to the figure below. Agilent 1220 Infinity Mobile Upgrade Kit 29

3 Installation Installing the Attenuation Unit to the Bench 3 Position the attenuation unit on the bench. The snap fasteners must be oriented to the front and the prepared holes in the attenuation unit must stand above the drill-holes in the bench. 4 Use the chosen screws or bolts to fix the attenuation unit to the bench. 30 Agilent 1220 Infinity Mobile Upgrade Kit

Installation 3 Securing the LC to the attenuation unit Securing the LC to the attenuation unit When Preparations WARNING Whenever the instrument is installed onto the attenuation unit in the mobile lab. Install the handle plate to the 1220 Infinity LC Instrument (see Installing the Handle Plate to the 1220 Infinity LC Instrument on page 20). Install the attenuation unit to the bench (see Installing the Attenuation Unit to the Bench on page 28). Personal injury or damage to the system The system is bulky and heavy. Lift the instrument with at least two persons. 1 Open the fixing angles (1) and slide the instrument on the handling plate onto the attenuation unit (2). Verify that it is completely fixed by the two rear retaining brackets (3). (2) (3) (1) (1) Agilent 1220 Infinity Mobile Upgrade Kit 31

3 Installation Securing the LC to the attenuation unit 2 Close the two front retaining brackets. 3 Secure the front retaining brackets by pressing the arrester button. NOTE The two front retaining brackets must always get closed and secured by pressing the arrestor button. They will not secure the instrument if not properly closed. 32 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 4 General Operation Instructions General Operation Instructions 34 This chapter provides general operation information. Agilent Technologies 33

4 General Operation Instructions General Operation Instructions General Operation Instructions General Operation Instructions NOTE Please note that the design of the 1220 Infinity mobile solution is intended for protecting the instrument from influences during transit. Analytical measurement however has to be conducted under stationary conditions. NOTE Operating the 1220 Infinity LC in a mobile lab environment can require special equipment or facilities to comply with local safety regulations (e.g. special solvent waste and storage containers). Please verify that these regulations are met before you operate the 1220 Infinity LC in your mobile lab. Preparing transit and relocation transit: relocation: 1220 Infinity Instrument installed on the attenuation unit while the mobile lab is moving. Moving the 1220 Infinity Instrument to or from the mobile lab. Park the arm of the autosampler before relocation or transit. Remove the solvent bottles from the solvent cabinet and store them in a proper safety storage. Verify that the retaining brackets on the attenuation unit are properly locked when the instrument is on the attenuation unit (see Securing the LC to the attenuation unit on page 31). Store the sample vials in a safe place during relocation and transit. The sample tray is not a proper storage place. General Operation Use sealed solvent bottle caps and waste containers to prevent dangerous vaporization. More information can be found in the chapter Consumables on page 36 in this manual and also on the internet: www.agilent.com/chem/safetycaps 34 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 5 Consumables Consumables 36 This chapter gives an overview of the recommended consumables. Agilent Technologies 35

5 Consumables Consumables Consumables Safety Cap I with 1 shutoff-valve (GL45) (5043-0225) (Comes with Venting valve (5043-0232)) Venting valve (5043-0232) with 1 µm PTFE membrane PEHD waste can (5043-0243) Comes with a S60 safety cap (5043-0227) including 4 ports and 1 leak port. The Charcoal filter ( (5043-0230) must be ordered seperately. Charcoal filter ( (5043-0230) 36 Agilent 1220 Infinity Mobile Upgrade Kit

Agilent 1220 Infinity Mobile Upgrade Kit 6 Appendix General Safety Information 38 Agilent Technologies on Internet 39 This chapter provides addition information on safety and web. Agilent Technologies 37

6 Appendix General Safety Information General Safety Information WARNING A WARNING alerts you to situations that could cause physical injury or death. Do not proceed beyond a warning until you have fully understood and met the indicated conditions. CAUTION A CAUTION alerts you to situations that could cause loss of data, or damage of equipment. Do not proceed beyond a caution until you have fully understood and met the indicated conditions. 38 Agilent 1220 Infinity Mobile Upgrade Kit

Appendix 6 Agilent Technologies on Internet Agilent Technologies on Internet For the latest information on products and services visit our worldwide web site on the Internet at: http://www.agilent.com Select Products/Chemical Analysis It will provide also the latest firmware of the modules for download. Agilent 1220 Infinity Mobile Upgrade Kit 39

www.agilent.com In This Book This manual contains information about the Agilent 1220 Infinity LC Mobile Upgrade Kit G4292. The manual describes the following: introduction, site requirements and specifications, installation, general operating intstructions. Agilent Technologies 2012 Printed in Germany 07/2012 *G4292-90000* *G4292-90000* G4292-90000 Agilent Technologies