SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 MUNICIPAL TESTING LABORATORY, INC. 375 Rabro Drive Hauppauge, NY 11788 Michael Jaycox 631-761-5555 INSPECTION BODY Valid To: July 31, 2019 Certificate Number: 3492.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this Type A (Third Party) inspection body for the following Special s and has been assessed against the applicable New York City Special requirements for the specific inspections identified below: Description of Special s Rules of the City of New York, 1RCNY 101-06, Appendix A; New York City Building Codes; The International Building Codes (IBC) 2014 Activities The inspection of quality, workmanship and requirements for construction. Materials, inspection and testing shall conform to applicable standards listed in the family of codes based on the International Building Codes (IBC) and each state s modifications to these codes and to the rules of the Local Code Officials. Specifically, New York City Chapter 1 of Title 28 of the Administrative Code for additional provisions relating to materials, testing and inspections. Wall Panels, Curtain Walls and Veneers BC 1704.10 procedure for Wall Panels, Curtain Walls and Veneers and Filed Plans Exterior Insulation Finish (EIFS) BC 1704.13 Chimneys BC 1704.26 procedure for Chimneys and Filed Plans (A2LA Cert No. 3492.01) 12/06/2017 Page 1 of 6
Description of Flood Zone Compliance BC G105, BC1704.29 Activities Luminous Egress Path Markings BC 1704.30, BC 1024.8 procedure for Photoluminescent Exit Path Markings and Filed Plans Sprayed Fire- Materials and Mastic and Intumescent Fire- Coatings BC 1704.11, BC 1704.12 procedure for Sprayed Fire-resistive materials (SFRM) & TM 12-A. Field Applied thin-film Intumescent Fire-resistive materials (TFIFRM) & TM-12B and filed plans Smoke Control BC 1704.15 procedure for Smoke Control and Filed Plans Sprinkler and Standpipe BC 1704.23, BS 1704.24 procedure for Sprinkler/Standpipe and Filed Plans Fire- Penetrations and Joints BC 1704.27 procedure for Firestop, Draftstop and Fireblock Emergency and Standby Power (Generators) BC 1704.31, 1707.7; NYCBC 2702 procedure for Emergency Power (Generators) and Filed Plans BC 1704.16 procedure for and Filed Plans Fuel-Oil Storage & Fuel-Oil Piping BC 1704.17 procedure for Fuel-Oil Storage and Piping and Filed Plans (A2LA Cert No. 3492.01) 12/06/2017 Page 2 of 6
Description of Private On-Site Storm Water Disposal and Detention Facilities, and Individual On-Site Private Sewage Disposal Installation BC 1704.21, BC 1704.22 Activities procedure for Site Storm Drainage and Detention Facilities and Filed Plans Heating BC 1704.25 procedure for Heating and Filed Plans Steel Welding, High Pressure Steam Piping, High Temperature Hot Water Piping, High Pressure Fuel- Gas Piping, Aluminum (2 RCNY 25 BAS Rule) BC 1704.3.1, BC 1704.18, BC 1704.3.31, BC 1704.19, BC 1704.28 procedure Welding and Filed Plans Steel Details BC 1704.3.2 Procedure for Steel Erection Steel High Strength Bolting BC 1704.3.3 procedure for High- Strength Bolting and Filed Plans Cold-Formed Steel BC 1704.3.4 Concrete-Cast-in-Place & Precast, Prestressed (Note: Licensed concrete testing lab to perform sampling and testing of cylinders) BC 1704.4 procedure for Concrete Cast-in-Place, and Concrete Precast and Filed Plans Masonry BC 1704.5 procedure for Masonry and Filed Plans (A2LA Cert No. 3492.01) 12/06/2017 Page 3 of 6
Description of Wood Prefabricated Wood I-Joists, Metal-Plate Connected Wood Trusses, and High-Load Diaphragms BC 10704.6 Activities Subsurface Conditions Subgrade BC 1704.7.1 procedure for Site Preparation and Filed Plans Subsurface Conditions Fill Placement, In place Density BC 1704.7.2, BC 1704.7.3 Subsurface Investigations Borings & Test Pits BC 1704.7.4, BC 1704.21.1.1, BC1802 Deep Foundation Elements BC 1704.8, BC 1808, BC 1809, BC 1810 Vertical Masonry Foundation Elements BC 1704.9 Underpinning BC 1704.20.3, BC 1814 procedure for Underpinning and Filed Plans Stability Existing Buildings BC 1704.20.1 procedure for Safety Stability, and Demolition and Filed Plans (A2LA Cert No. 3492.01) 12/06/2017 Page 4 of 6
Description of Stability Demolition BC 1704.20.4 Activities procedure for Safety Stability, and Demolition and Filed Plans Stability Raising and Moving of a Building BC 1704.20.5 procedure for Safety Stability, and Demolition and Filed Plans Excavation-Sheeting, Shoring and Bracing BC 1704.20.2 procedure for Excavation Sheeting, Shoring and Bracing and Filed Plans Seismic Isolation BC 1707.8 procedure for Seismic Isolation and Filed Plans Post-Installed Anchors, Concrete & Masonry BC 1704.32 (A2LA Cert No. 3492.01) 12/06/2017 Page 5 of 6
s Preliminary AC 28-116.2.1 Not applicable Compliance AC 28-116.2.2 Event specific Final AC 28-116.2.4.2 Compliance with filed plans Place of Assembly Emergency Lighting AC 28-116.2.2; BC 1006 Footing and Foundations BC 109.3.1 Lowest Floor-Elevation BC 109.3.2, BC G105.3-1 Frame BC 109.3.3 Fire-Resistance BC 109.3.4, BC 109.3.5, BC 109.3.6 Energy Code Compliance BC 109.3.5 Other Compliance BC 109.3.6 Event Specific of Fabricators BC 1704.2 Special Cases BC 1704.14 Event specific Special Cases Standard for Agencies Engaged in, Testing or Special ASTM E329 This specification defines the minimum requirements for agencies engaged in: a) of construction activities and materials used in construction, b) Testing of construction activities and materials used in construction, and c) Special (A2LA Cert No. 3492.01) 12/06/2017 Page 6 of 6
Accredited Body A2LA has accredited MUNICIPAL TESTING LABORATORY, INC. Hauppauge, NY for technical competence in and compliance with the Body Accreditation Program This inspection body is accredited in accordance with the recognized International Standard ISO/IEC 17020:2012 Conformity Assessment Requirements for the operation of various types of bodies performing inspection. This accreditation demonstrates technical competence for a defined scope and the operation of a quality management system. Presented this 6 th day of December 2017. President and CEO For the Accreditation Council Certificate Number 3492.01 Valid to July 31, 2019 For the inspections to which this accreditation applies, please refer to the organization s Body Scope of Accreditation.