Powerdek Fleck. SECTION Resilient Athletic Flooring

Similar documents
SECTION Resilient Athletic Flooring

Control XT SECTION Resilient Athletic Flooring

The complete installation of a prefabricated rubber sports surface including adhesive and game line striping as manufactured by Connor Sports Flooring

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION Resilient Athletic Flooring

The complete installation of a prefabricated rubber sports surface including adhesive and game line striping as manufactured by Connor Sports Flooring

CONNOR PowerDek Page 1

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Page 1 of 5 PART 1 GENERAL

1.02 RELATED REQUIREMENTS NOTE:

1.02 RELATED REQUIREMENTS NOTE:

MondoArmor (18mm) Technical Specification Sheet

Division 9 Resilient Athletic Flooring

Advance NG (6mm) Technical Specification Sheet

CONNOR Control XT Page 1

Sport Impact (10mm) Technical Specification Sheet

SECTION Rubber Tile Flooring

1. CONCRETE SUBFLOORS.SECTION a. Slab Depression: Equal to thickness of selected flooring (6, 8,10,12,13 or 14mm).

Performance Rolls GUIDE SPECIFICATIONS Manufactured in the U.S.A. by:

NEW HARMONI (3mm) Technical Specification Sheet

Harmoni (3 mm) Technical Specification Sheet

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

SECTION (09620) - RESILIENT ATHLETIC FLOORING

RESILIENT FLOORING: Hot and Heavy - Secoya

UPOFLOOR Quartz Tile Architectural Guide Specification CSI/CSC Section Format [3-part] CSI Page Format

5 ATHLETIC SURFACING (RUBBER SHEET GOODS) (ADVANCE, RAMFLEX, SPORT IMPACT AND MONDOFLEX PRODUCTS)

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

Division 9: Section RESILIENT ATHLETIC SURFACING (Regupol AktivLok Recycled Rubber)

.2 Section Waste Management and Disposal. 1.2 REFERENCES.1 Codes and Standards referenced in this section refers to the latest edition thereof.

RESILIENT FLOORING: Select Step Wood

Rubber Flooring Installation Guidelines

ECOfit Rolls GUIDE SPECIFICATIONS ECORE Commercial Flooring

Section RESILIENT TILE FLOORING INCLUDING ECONATURALS RUBBER FLOOR TILE

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

INSTALLATION MANUAL FULLY ADHERED INSTALLATIONS

American Guild Vinyl Flooring - Steadcrest Collection Installation Instructions

Installation Instructions Vinyl Glue Down Flooring - Pro

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE

RESILIENT PHOTOLUMINESCENT STAIR TREADS

CSI Exceed PART 1.0 GENERAL. plae.us SUMMARY 1.2 REFERENCES

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

SECTION RESILIENT TILE FLOORING

Section STATIC DISSIPATIVE RESILIENT FLOORING

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP#

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

Section RESILIENT SAFE-T VINYL SHEET FLOORING

SECTION LITHIUM BASED MOISTURE VAPOR CONTROL CURE SYSTEM AND FINISHING

MONDO MP 1000 ACRYLIC ADHESIVE DISCLAIMER: Refer to page 5 of this document.

RESILIENT ECO NATURALS, DEFIANT, AND PHOTOLUMINESCENT STAIR TREADS

Wood Floor Bonding Systems

INSTALLATION INFORMATION

Action QuickCourt R Modular Athletic Flooring

Action Herculan MF 7+2 Synthetic Floor System

CONDUCTIVE RESILIENT FLOORING

1. Amarco Products Athletic Recycled Rubber Sports Flooring Rolls and Interlocking Tiles 2. Adhesives

Specification Note: For the name of the local Robbins Performing Arts representative or dealer, call

4 COMMERCIAL RUBBER TILES (GRANITO, HARMONI, KAYAR, UNI, TERRANOVA AND ZEUS)

1/16 Single Broadcast Polymer Flooring System

ProXL INSTALLATION GUIDE

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

SECTION RESILIENT FLOORING ACCESSORIES

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6

Moisture barrier for protection of flooring assemblies up to 99.5% relative humidity

SECTION COATED RUBBER ATHLETIC FLOORING

9 RUBBER TRACK SURFACING (INDOOR APPLICATIONS) (FOR ALL SPORTFLEX, SUPER X AND MONDOTRACK PRODUCTS)

Fastrack Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Centaur

ARCHITECTURAL GUIDE SPECIFICATIONS

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6

Student Services & Classroom Addition

1. Division 09 Section "Rough Carpentry."

SECTION COATED RUBBER ATHLETIC FLOORING

SECTION TERRAZZO FLOOR TILE

1.1 DESCRIPTION OF WORK A. Provide new resilient flooring and base where noted on drawings.

CONDUCTIVE RESILIENT FLOORING

GUIDE SPECIFICATION

GUIDE SPECIFICATION

INDOOR RUBBER FLOORING INTERLOCKING INSTALLATION / MAINTENANCE GUIDELINES MARATHON SERIES. Four-Side Interlock Loose Lay Installation

WARNING: SHOULD THE INSTALLATION SEQUENCE NOT FOLLOWED. THE INSTALLATION WILL FAIL IMPORTANT: SEE PAGE 6 0F THIS DOCUMENT

ALETTE GLUE DOWN INSTALLATION INSTRUCTIONS

LINOLEUM SHEET FLOORING

Division Resilient Athletic Flooring

Training Ground with Nike Grind RubberX GUIDE SPECIFICATIONS Ecore

Ecore Athletic Stacked Performance Collection Rolls and Interlocking Tiles GUIDE SPECIFICATIONS Ecore

Section RESILIENT TILE FLOORING INCLUDING SOLID VINYL FLOOR TILE

Product Size Thickness Installation direction Seams treatment

Installation Guide LVP Glue Down

EXPANKO RESILIENT FLOORING PRE-INSTALLATION GUIDELINES

Action ReFlex Spin Resilient Floor System

Architectural Guide Specification CSI/CSC SectionFormat [3-part] CSI PageFormat. Tel Fax

Action Herculan RH Synthetic Floor System

Transcription:

SECTION 09622 Resilient Athletic Flooring PART 1: GENERAL 1.0 SUMMARY 1.0.1 Work Included A. Prefabricated Rubber Sports Flooring B. Adhesive and accessories required for installation and maintenance 1.0.2 Related Sections A. Section 03300: Concrete Substrate a. The concrete contractor shall furnish and install a slab that is smooth troweled, level to within 1/8 in any 10 radius, and depressed (if so specified) to the full depth of the flooring system. High spots shall be ground and low spots filled with an approved leveling compound by the concrete contractor to meet the approval of the floor contractor. b. No curing compounds, agents or sealers shall be used. B. Section 07100: Waterproofing Membrane a. The project engineer should specify an under slab waterproofing membrane according to need. C. Section 08700: Thresholds a. Thresholds or transition strips should be installed by the flooring contractor and should be chosen to accommodate the need presented by the specified system and adjacent areas. 1.1 REFERENCES 1.1.1 American Society for Testing & Materials (ASTM) A. ASTM D 2240: Standard Test Method for Rubber Property Durometer Hardness B. ASTM E 648: Standard Test Method for Critical Radial Flux of Floor-Covering Systems Using a Radiant Heat Energy Source C. ASTM E 662: Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials 1.2 SYSTEM DESCRIPTION A. Furnish and install the Powerdek fleck rubber athletic flooring by Traction. B. Powerdek fleck is a prefabricated rubber sport surface consisting of a base of natural rubber, synthetic rubber and stabilizing agents, which are vulcanized together. C. Powerdek fleck materials shall be in tiles that are 1m (39.2 in) x 1 m (39.2 in) or in rolls with a thickness of 6, 8 or 10mm. 1

1.3 SUBMITTALS Powerdek Fleck A. Product data, including manufacturer s information for specified products B. Samples for colors and textures C. Shop drawing showing seam layout, profiles and product components D. Installation and maintenance instructions. 1.4 QUALITY ASSURANCE A. The manufacturer must have a minimum of five (5) years experience in the manufacturing of prefabricated rubber surface. B. Installer must have performed installations of the same scale in the last three years. C. Installer to be recognized and approved by the athletic rubber flooring manufacturer. 1.5 MAS Certified Green A. MAS Certified Green Indoor Air Quality Certified B. MAS Certified Green Children and Schools Certified 1.6 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) A. ISO 9001: Requirements for Quality Management Systems. B. ISO 14001: Requirements with Guidance for Use for Environmental Management Systems. 1.7 DELIVERY, STORAGE, AND HANDLING A. Materials must be delivered in manufacturer s original, unopened and undamaged containers with identification labels intact. B. Store material up-right, protected from exposure to harmful weather conditions, on a clean, dry, flat surface protected from all possible damage. C. Area where materials are to be stored to be maintained at a minimum of 55 o F and under 50% relative humidity. D. Material need not suffer excessive damage during handling (i.e. edge chipping, excessive warping, etc). 1.8 SITE CONDITIONS A. Maintain a stable room and sub floor temperature for a period of 48 hours prior, during and 48 hours after installation. Recommended range: 65 o F to 80 o F (18 o C to 27 o C). B. Installation to be carried-out no sooner than the specified curing time of concrete sub floor (normal density concrete during time is approximately 28 days for development of design strength). C. Substrate Flatness (concrete or asphalt) must not vary more than 1/8 in 10 radius. D. Moisture vapor emission content of the concrete slab must not exceed 5lbs/1000ft2 per 24 hrs when using the Calcium Chloride test as per ASTM F 1869. 2

E. Installation of athletic flooring will not commence unless all other finishes in the building have been completed. 1.9 WARRANTY A. Provide manufacturer s standard warranty. B. The athletic rubber flooring is warranted to be free from manufacturing defects for a period of three (3) years from the date of shipment from the manufacturer. 1.10 MAINTENANCE AND REPAIR A. Provide attic stock of each type and color. B. Repair material must be from the same dye lot as material supplied for initial installation. C. Maintain surface as per manufacturer s instructions. PART 2: PRODUCT 2.1 MANUFACTURER Basis for design PowerDek Fleck by TRACTION, North American Specialty Flooring, Woodstock, IL 866-757-5569 2.2 PowerDek Fleck 2.2.1 Description A. PowerDek Fleck is a multi-use rubber athletic flooring. a. Prefabricated rubber sport surface to be manufactured in two layers, which are vulcanized together. Shore hardness of the respective layers to be as recommended by the manufacturer and within the limits hereinafter specified. b. Smooth finish with flecks c. Thickness: 6, 8, or 10mm d. Color: Provided in standard and custom colors. e. Material available in: Roll Goods, Tiles (1m x 1m) and Interlocking Tiles 2.2.2 Physical Properties A. Physical properties of the prefabricated athletic rubber floor, to conform to the following requirements: Physical Properties Standard Powerdek fleck Thickness 6, 8, 10 Hardness Shore A ASTM D 2240 75/68( ±5) Water Absorption ASTM D 570 (%) 0.13 Tensile Strength (kgf/cm²) ASTM D 412 (psi) 37 Ultimate Elongation ASTM D 412 (%) 275 3

Modulus 20% ASTM D 412 (%) 175 Tear Abrasion ASTM D 501 PASS Tear Resistance ASTM D 624 (lbs/in) PASS (161) Dimensional Stability ASTM D 1204 +0,02 Density of Smoke ASTM D 662 PASS (< 411) ASTM E 648 (w/cm2) / (class NFPA 101) 0.45 W/cm², Class 1 Critical Radiant Flux Compression Set (70 C, 22h)(%) ASTM D 395 (%) 84 Friction Test ASTM D1894-01 0.99 (Dry) & 1.11 (Wet) Fire Resistance Static Load Limit (250 psi, 24h) (mm) ASTM F970-07 Class 1, Inflammable 0.46 2.3 MATERIAL A. Provide VOC compliant adhesive certified by the manufacturer or distributor. B. Patching compound and line marking paint, to be supplied or approved/recommended by rubber sport flooring manufacturer or distributor. PART 3: EXECUTION 3.1 EXAMINATION AND PREPARATION The following must be ensured prior to installation of the primary product: A. Concrete of Asphalt sub floors to be placed a minimum of thirty (30) days prior to the installation of athletic rubber floor. B. No concrete or asphalt sealers or curing compounds are applied or mixed with the sub floors (refer to Section 03050 of Division 3 and/or Section 02065 of Division 2). C. The underlayment is adequate (if installing over wood sub floors). APA Exterior Underlayment Grade Plywood is recommended. D. Water vapor membrane complies with specification in ASTM E 1745. E. Alkalinity test and moisture test must be performed. PH level should be in the range of 7 to 8.5. Moisture content must not exceed 5lbs/1000ft2 per 24 hrs (verify using the calcium chloride test as per ASTM F 1869). F. Smooth, dense finish, highly compacted with a tolerance of 1/8 in the 10ft radius (3mm in 3.05 m radius). Floor flatness and floor levelness (FF and FL) numbers are not recognized. G. Concrete or asphalt sub floors on/or below-grade are installed over a suitable moisture retardant membrane as per ASTM E 1643 and E 1745. H. Sub floors must be clean, free of paint, dust, sealer, hardeners, grease, oil, solvents, or adhesive and any other foreign substances that may act as a bond barrier. I. Sealing of cracks, holes and, smoothing and leveling of rough, uneven surfaces, must be carried out using a good quality Portland cement based leveling compound (feathering compound), approved by the manufacturer. 4

J. Installation will not be carried out unless above conditions are satisfied. K. Report any discrepancies to the General Contractor or Owner for correction. 3.2 INSTALLATION A. The surrounding area of the mixing of the adhesive should be covered with plastic, Kraft paper, or other material to protect the area. B. Verification must be made on the type of product, the size, depth, color, quality, and any defects the material may have. If any of these problems are observed, NASF must be contacted prior to installation. If contacted after this time no claims will be accepted. The surface must also be inspected and all standards must be met. C. Next, square the room using chalk lines parallel to the room length. The PowerDek Fleck (tiles) material should be then laid out in an ashlar or brick pattern. D. Mix and apply adhesive according to manufacturer s recommendations. E. When beginning the first row the adhesive should be applied evenly up to 2 (5cm) from both edges of the seams and up to 12 (30cm) from the end seam. F. Complete an entire row before attempting to start the next row. G. To start the second row, apply the adhesive underneath the seam the same as above for the previous row as well as for the next row. (2 (5cm)) H. Make sure that there is a good transfer of the adhesive when installing the material in the wet adhesive. I. Remove all excess adhesive that may ooze through the seams or any drops that may have dripped onto the surface. This can be done by rubbing with denatured rubbing alcohol. Do this before it dries. J. For perfect seams use masking tape to hold the tiles together tight. Use 2 (5cm) masking tape to help to close gaps in the seams and keep them in place while the adhesive sets. Do not use duct tape EVER, it will chemically react with the flooring surface. K. To eliminate any trapped air, use a lightweight roller 120 lb (55kg) and always roll this at a 45 angle. L. Be cautious when adjusting the end seams to not apply too much pressure while ensuring them to be perfectly sealed. If a seam becomes pressured, this too will cause peaking. 5