SYSTEM S4-RHOMBOS INSTALLATION MANUAL

Similar documents
SYSTEM S7-RHOMBOS INSTALLATION MANUAL

SYSTEM ATHMOS INSTALLATION MANUAL

S7 Taifun Installation Manual

S4 Taifun Installation Manual

S7 rhombos. expanded metal ceiling. Product data sheet. durlum.us. Your contact for North America

metal ceiling S7 rail channel system Product data sheet durlum.us Your contact for North America

SYSTEM W-H 1100 Wall cladding. Metal product

ROCKFON SYSTEM T24 X

" RISKS ASSOCIATED WITH THE INSTALLATION OF THE SYSTEM

Sustainable ceiling and lighting solutions

HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE

ifix INSTALLATION MANUAL PV flat roof installation system Version

Installation Guideline

PERI UP Easy * The lightweight and fast frame scaffold for safe working on facades

OWAplan. Seamless ceiling tile Installation guidelines OWAplan. OWAconsult collection

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

Conergy SolarFamulus II

Installation Guideline

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

SMART FIXING SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Installation guideline Lindner LMD-L 607

SMART FIXING SYSTEMS profiles pro ofilees

METALWORKS RH215 Faceted Custom Hook-on Panels

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E

Technical Information Dampa TILES Decorative Marine Ceiling System

WALL CLADDING. Gema System W-H 1100 CEILING&WALL SYSTEMS. Between us, ideas become reality

FLAMRO FKS Ready Cable Duct System

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN

ThermaSteel Corporation ASSEMBLY MANUAL

National technical approval

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

Installation Instructions

Rockfon System T24 Stepped Z D

Technical data sheet StoSilent Board 100

Z5054 Ci60/Ci90 Flying adapter Mounting instructions

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels

ROCKFON SYSTEM T24 XL A, E

Installation Instructions

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION

Construction Standards PAGE

Installation guide. ROCKFON System Z mm. 600 mm

unity 6 system / Demountable T-grid Ceiling

Student Services & Classroom Addition

CI/SfB. June RockLink 24 Monolith. Installation system

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Mounting systems for solar technology

Endure 900 Suspended Ceiling Installation Guide

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

DID YOU KNOW THAT. Knauf Danoline acoustical ceilings and walls can meet your national requirements in terms of acoustics?

TRITEC light Steel Panel Formwork

ifix Installation Manual PV flat roof mounting system english Version May 1st, 2018

lindab we simplify construction LindabSmoke control system single compartment Rectangular Mounting instruction

CI/SfB. October RockLink 15. Installation system

RULON LINEAR OPEN SUSPENDED WOOD CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

Exterior System installation instructions

K-H 400 SYSTEM. Tartan Grid

Z5043 MAX Horizontal bracket Mounting instructions

General Design Approval

SECTION COLD-FORMED METAL TRUSSES

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

ROCKFON SYSTEM ULTRALINE E

Rolling Towers. Layher Rolling Towers Uni Wide. Safety Structure Instructions for Assembly and Use. Mobile working platforms to DIN EN 1004:

METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger

Unitised Curtain Wall Beaded

Ventura Office Partitions. Technical guide

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION ACOUSTICAL PANEL CEILINGS

SECTION GYPSUM BOARD PART 1 - GENERAL

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Technical datasheet Number 05 / updated November 2009

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Clip-in and hook-on ceilings

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Curtain Wall Stick System (Capped)

Thermatile Ten-Twelve Radiant Panels. Installation instructions

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

SECTION 31 ACCESS FLOORS

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Rockfon System Maxispan T24 A, E

EDGE D2 CONNECT GRID. Design and technique. Installation manual. Load. Product description. Stability. Plenum height. Weight.

INSTALLATION GUIDE. Guidelines for the planning and installation of OWAtecta Metal Ceiling Systems

Ecophon Focus Ds. System range. Size, mm 600x x x x x x x600 T24 Thickness (THK)

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Modular Scaffolding MEKA 48

Union County Vocational - Technical Schools Scotch Plains, New Jersey

LindabSmoke control system

LINEAR METAL CEILINGS Section

Mounting instructions. novotegra for trapezoidal metal - roof parallel

System F - Free Span Systems

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Strengthened Soil Wall Construction Manual

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

mounting systems applications overview

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

Transcription:

SYSTEM S4-RHOMBOS INSTALLATION MANUAL

GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant products. durlum is a leading German manufacturer of metal ceilings and cladding elements, mainly made of galvanised sheet steel, aluminium and expanded metal. CERTIFICATE The Certification Body of TÜV SÜD Management Service GmbH certifies that durlum GmbH An der Wiese 5 79650 Schopfheim Germany has established and applies a Quality and Environmental Management System for the following scope of application: Planning, development, manufacturing and sales of metal ceilings, functional ceilings, luminaires, lighting and daylight systems. Performance of audits (Report-No. 70014435) has furnished proof that the requirements under: ISO 9001:2008 ISO 14001:2004 ISO 50001:2011 are fulfilled. The certificate is valid from 2014-07-27 until 2017-05-29. Certificate Registration No. 12 100/104/340 25601 TMS Product Compliance Management Munich, 2014-06-17 The relevant products are described in the marketing and sales documents. They are both acoustically effective, and can also be used as design elements only. Specifically, these products are: Acoustic ceilings Chilled ceilings CHARACTER products durlum differentiates between a wide range of ceiling systems, for example S1. S1 stands for system 1 clamping. In this system, there are different nomenclatures that allow a further subdivision of the systems. All durlum systems are systems of modular design. This applies not only to the substructure but also the ceiling parts that are suspended, locked into place or placed on the substructure. durlum metal ceilings comply with the standard EN 13964:2007 and are CE-certified. Appropriate static certificates are available for special systems marketed by us and for which no general approvals are available, and appropriate designs compliant with EN 13964 have been constructed. durlum lamps comply with standard EN 60598-1 and are CE-certified. GUIDELINES These installation instructions have been structured in accordance with the requirement of EN 13964:2007 and describe a proper assembly. The description does not exempt the user from examining the structural conditions, implementing the building code regulations and observing the information given in the building permit prior to starting assembly. They have priority, but could not be included here. It is advisable always to draw up assembly diagrams/drawings, to establish the location where assembly is to begin and to establish the required suspension points for the relevant ceiling system prior to starting assembly. STRUCTURAL PRECONDITIONS Metal ceilings may usually be installed as soon as the building is swept clean, but at least when all wet work in the interior has been completed and the building has been closed. Prior to starting assembly, the suspension points must be checked for their usability, and load introduction into the building must be guaranteed. When using wall mounting points, such as brackets or wall anchors, the load-carrying capacity of the wall in question must be checked. If ceiling elements rest on brackets, possible wall movements must be taken into account. Only anchors for which a general building supervisory approval is available may be used, and their minimum extraction force must be greater than 100 kg. The anchors must be mounted as specified by the relevant anchors manufacturer. We recommend performing regular tensile stress tests, to verify that anchors have been set correctly. durlum metal ceilings are dimensioned such that they carry their own weight of the system construction plus a surface load amounting to 40 N/m². Higher loads must be taken into account or suspended separately in the construction, and the measures must be adapted to the situation at hand. Usually, built-in components and loads must be suspended separately. For ceiling systems that do not allow any tolerance compensation within a module, suitable material expansions must be taken into account. Building expansion joints and tolerances customary in building construction must be taken into account accordingly. durlum metal ceilings must always be assembled by expert dry building companies who are capable of assessing the overall situation in the building, the metal ceiling, the cladding surface, as well as the structural conditions and are able to take suitable precautions for ensuring proper assembly. If parts from different manufacturers are used to assemble the ceiling, the relevant mounting company must provide the certificates required by EN 13964:2007 and must obtain suitable certificates of conformity itself. Liability for proper selection of the products and system conformity can only be assumed for the systems delivered by durlum. To prevent the parts from becoming dirty, gloves must be worn during assembly. If the ceiling products are delivered laminated with a protective film, they must be protected from exposure to UV radiation [sunlight], the film must likewise be removed from the goods no later than 4 weeks after delivery, and the storage temperature must not exceed 30, since otherwise the adhesive on the panel may become hardened, and the protective film can no longer be removed. STORAGE durlum metal ceilings are usually delivered on pallets. It is advisable to leave the metal panels on the pallets as long as possible. If the pallets need to be opened, the durlum POLYLAM should always be placed on its underside. Storage must be carried out such that damage is excluded. The assembly of the ceiling panels must not start until all dust-producing work has been completed [swept clean]. durlum products are certified according to ISO 9001 for development, production, sales and also for service. Nevertheless, it is recommended to always subject the metal ceilings immediately to an inspection and to report any complaints right away [usually immediately following delivery or within 3 days]. Visible damage must be noted on the delivery note. 2 durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014

GENERAL INFORMATION STANDARDS AND REGULATIONS The relevant regulations applicable at the installation site must be determined by the assembly company in question. The ceilings marketed by durlum conform to EN 13964. This standard also governs fire behaviour in accordance with EN 13501. APPLICATION The application of durlum metal ceilings is restricted, unless agreed upon otherwise, to interiors, so that, pursuant to EN 13964, class of use 1, corrosion protection class A, has been defined here as standard. The use of durlum lighting is restricted to interiors. The lighting complies with protection class IP 20, protection class 1 according to EN 60598-1. Should it become necessary to adjust the metal ceiling panels to the building by cutting, we recommend protecting the cutting edges from corrosion by means of a paint, to maintain the corrosion protection class A. QUALITY STANDARD For material properties, dimensions, tolerances, colour deviations, the TAIM Directives [Technical Association of Industrial Metal Ceiling Manufacturers] applies. MOUNTING SEQUENCE 1. Prepare ceiling- and lighting installation plan or adopt architect's plan. 2. Check ceiling lighting installation plan versus structural conditions. 3. Prepare a bill of materials, including a suitable work plan and retrieval/order of the materials required. 4. Determine the required suspension points in accordance with the classes of use of EN 13964. The corresponding suspension distances for the different systems can be taken from the detailed descriptions of the individual ceiling systems. 5. Establish which generally approved anchor is suitable. Check the raw ceiling and the walls. Mark the anchor mounting holes and drill them. Mount the anchors as specified by the anchor manufacturer and carry out extraction tests using the device recommended by the anchor manufacturer, if necessary. 6. Use the same procedure when mounting the wall brackets, mounting distance about 400 625 mm, check the introduction of force into the wall. 7. Shorten intended fastening elements, such as the M6/M8 threaded rod to the intended length or order the correct length and mount it on the raw ceiling. 8. Usually, the panel layout should be started from the centre of the room, in order to be able to compensate the tolerance of the room and cut the panels in half, if necessary. The precise arrangement must always be done on the basis of the ceiling layout plan. 9. durlum metal ceilings are usually provided with a cross support [primary profile]. 10. Use the layout plan to determine in which direction the cross reinforcement profiles are laid, either in parallel to the façade [usually] or vertically to the façade. The cross reinforcement profiles should be mounted via a wall anchor or via a diagonal anchoring to prevent an axial movement. The corresponding primary profiles are mounted at right angles to the secondary profiles. To this end, the system-specific connecting elements are used, see system descriptions. The position of the primary profiles is established in the reflected ceiling plan. 11. The metal ceiling panels are often provided with a joint tape [9x3mm], to make for easier tolerance compensation. Should a joint tape be used, the joints must also be re-aligned from time to time, since the joint tape also has tolerances. However, owing to the high production precision, it is also possible to connect the panels without a joint tape by using butt joints or provide them with rubber spacer naps. Always ensure that the joints are aligned. 12. If the panels are placed on a perimeter trim, we recommend our F-bracket as bracket or as stepped F-bracket. The bracket secures the panel and protects it against lifting. The ceiling panel is cut with electric sheet shears [i.e. Treco shears] and adapted to the prevailing room dimensions. When calculating the minimum support area [10mm], the dimensions of possible wall movement should be taken into account. 13. Attachments or other loads are to be mounted separately. For logical reasons these parts are integrated during the mounting process. 14. After completion and pre-acceptance of the ceiling, the sequence of joints should be re-aligned. Soiled ceiling panels should be cleaned to give a perfect result for assembly. durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014 3

SYSTEM S4-RHOMBOS INSTALLATION MANUAL 1 100 7 100 3 3 4 5 4 5 2 40 ~92 50 2 50 40 ~92 6 6 1 2 3 Threaded rod M6 Hook-on carrier U 1005 A Holding and fixing clamp U 1044 FK 4 5 6 Connector U 1044 L-shaped primary carrier U 1040 Expanded metal panel 7 Vernier scale 4 durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014

INSTALLATION MANUAL SYSTEM S4-RHOMBOS ABBREVIATIONS AP: Distance of primary profiles U 1040 AS: Distance of secondary profiles U 1005 A AH: Distance of the suspension hangers in axial direction of the primary profile DISTANCE OF THE SUSPENSIONS ETC. The following recommendation for the distances of the primary profiles and the suspension points refers only to standard ceilings in indoor applications without additional loads. Distance of the primary profiles AP according to EN 13964: Class 1: <1 000 mm Class 2: <1 200 mm Distance of the secondary profiles AS according to EN 13964: Depending on the panel length Distance of the suspension points AH: The distance of the suspension points AH is determined by the corresponding panel length. The L-shaped primary carrier serves mainly for cross bracing. The maximum force applied to the suspension point may be 200 N. The corresponding suspension parts and dowels must be taken into account. If it is not possible to specify in advance where the secondary profiles will run, select the following distances of the suspension points AH: Class 1: <1 000 mm Class 2: <1 200 mm Load-carrying capacity of the suspension points [tensile loads]: Maximum load per vernier suspension: 200 N Maximum load per threaded rod M6: 500 N Other loads must be verified statically. Stress class according to EN 13964: Stress class A according to Table 7 PLEASE NOTE Use only officially approved dowels. The fastening base must be suitable in terms of statics. It must be able to reliably absorb the forces introduced into the construction. ASSEMBLY OF THE SUSPENSION Assembly of the wall bracket: The regular distance for mounting the perimeter trim is max. 500 mm. This regular distance is less, depending on additional loads, the type of wall and special requirements. 1. Level and outline the given ceiling height. 2. Outline the upper edge of the perimeter trim. 3. Mark the drill hole. 4. Drill a hole for the dowel. 5. Secure the perimeter trim with a dowels. 6. Cleanly mitre cut the edges of the perimeter trim profiles. Assembly of the primary profile [U 1040]: 7. Outline the axis grid for the primary and secondary profiles. 8. Define the suspension points. 8.1. The suspension hanger of the primary profile should be mounted as closely as possible to the crossing point of the primary and secondary profiles. The maximum distance between the suspension hanger and the secondary profile is 100 mm [see also "Distance of the suspension points AH"]. 8.2. Module adapters [cross connectors] may not be mounted at the joint of the primary profiles. 8.3. Keep at least 400 mm distance to the joint of the primary profiles. 8.4. The maximum distance of a suspension point from the wall is 500 mm. 9. Drill a hole for the dowel. 10. Mount vernier scale upper part U 1300 or threaded rod M6 with dowels according to the manufacturer's instructions. 11. Cut the L-shaped primary carrier U 1040 to the required length. 12. Fasten the vernier scale lower part U 1370 to the suspension points with a self-securing screw connection M6. 13. Place the L-shaped primary carrier U 1040 horizontally, vertically and aligned for the given ceiling height. 14. Secure vernier scale lower part U 1370 to vernier scale upper parts with two vernier scale safety pins U 1372. When using the threaded rod suspension, the threaded rod is guided through the horizontal shank of the L-shaped primary carrier and rigidly fastened with the self-securing screw connection M6. 15. The L-shaped primary carrier connector U 1041 is connected to the joint of the L-shaped primary carrier using a selfsecuring screw connection M6. Arrange the longitudinal connections of the profiles offset to one another. 16. When adjusting the height, observe the permissible height tolerances according to EN 13964, readjusting it, if necessary. 17. The primary profiles must be connected to the wall at least on one side with the wall bracket U 1042 to exclude any shift in axial direction. Assembly of secondary profile [U 1005 H]: 18. Outline the predefined axis grid for the secondary profiles at the L-shaped primary carriers. 19. Cut the hook-on carriers U 1005 A to the required length. 20. Mount the hook-on carriers with the module adapter U 1044 and the fixing clip U 1044 at the L-shaped primary carriers U 1040. 21. Align the hook-on carriers and snap the fixing clip U 1044 FK into place completely. 22. Centre the connector U 401 above the joint of the hook-on carriers U 1005 A and secure it with drilling screws. Required longitudinal connections should be arranged offset to one another. ASSEMBLY OF THE CEILING PANELS 1. Wear clean cotton gloves. 2. Remove the protective film from the ceiling panels, if available. 3. Place the ceiling panel with the Z-edge [AS3] on the hook-on carrier U 1005 A or adjacent ceiling panel. 4. Insert the ceiling panel with the hookon edge [AS6] using the vertical suspension bracket of the hook-on carrier. 5. Lower the ceiling panel and place it on the hook-on carrier or on the adjacent ceiling panel. 6. Check the joint for perpendicularity and uniform width; if necessary, readjust the hook-on carrier to the required axial dimension. 7. Determine the length of the precut shim in the border area. In doing so, take into account the two different types [panels with suspension bracket AS6 or with Z-edge AS3]. 8. Cut the precut shim to size using an angle cutter and deburr the cutting edges. 9. Insert precut shim and place the cutting edge on the perimeter trim [F-lip mounted pointing upwards]. durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014 5

DISASSEMBLY OF THE CEILING PANELS 1. Wear clean cotton gloves. 2. Lift the adjacent panel of the ceiling panel to be dismounted. 3. Lift the ceiling panel to be dismounted, remove it using the hook-on edge [AS6] and lower it. 4. Carefully lower the adjacent ceiling panel. 5. Put the ceiling panel down and store it protected against damage. 6 durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014

CEILING LIGHTING AMBIENCE PLAFOND LUMIERE AMBIANCE durlum GmbH An der Wiese 5 D-79650 Schopfheim T +49 [0] 76 22 39 05-0 F +49 [0] 76 22 39 05-42 E info@durlum.com I www.durlum.com durlum GmbH www.durlum.com Subject to changes of dimensions and design. Errors reserved. All rights reserved. Issued: 28.07.2014 7