Human CEACAM6 ELISA Pair Set

Similar documents
Mouse CD34 ELISA Pair Set

Human BMP-2 ELISA Pair Set

Human Junctional Adhesion Molecule A / JAM-A ELISA Pair Set

Human IGFBP7 ELISA Pair Set

Human CD21 ELISA Pair Set

Human TNF-alpha / TNFA / TNFSF2 ELISA Pair Set

Human SLAMF6 / Ly108 ELISA Pair Set

Human ECM1 ELISA Pair Set

Human C-Reactive Protein / CRP ELISA Pair Set

Human CALML5 ELISA Pair Set

Mouse IFNAR1 ELISA Pair Set

Human ADAM15 ELISA Pair Set

Mouse Axl ELISA Pair Set

Human IGFBP3 ELISA Pair Set

Human ICAM-2 / CD102 ELISA Pair Set

Human Transferrin / TF ELISA Pair Set

Rhesus CD16 / FCGR3 ELISA Pair Set

Cynomolgus p53 / TP53 ELISA Pair Set

Human IL10RB ELISA Pair Set ( CRFB4 )

Mouse ICAM-1 / CD54 ELISA Pair Set

Human SPARCL1 / SPARC-like 1 ELISA Pair Set

Human PRLR / Prolactin Receptor ELISA Pair Set

Human PTH / PTH1 / Parathyroid Hormone ELISA Pair Set

Human AFP / alpha-fetoprotein ELISA Pair Set

Rat ACE2 / Angiotensin- Converting Enzyme 2 ELISA Pair Set

Mouse SerpinF2 ELISA Pair Set

Human KNG1 / Kininogen 1 ELISA Pair Set

Human Granulin / GRN / Progranulin ELISA Pair Set

Human alpha-galactosidase A / GLA ELISA Pair Set

Human Angiotensinogen / SerpinA8 / AGT ELISA Pair Set

mouse IL-6 Catalog Number: DY406

Monkey apolipoprotein A1 (Apo-A1) ELISA Kit. For the quantitative determination of monkey apolipoprotein A1 (Apo-A1) concentrations in serum, plasma.

Human Cluster of Differentiation 68 (CD68) ELISA Kit

Human GTPase KRas (KRAS) ELISA Kit

Human vascular endothelial cell growth factor A (VEGF-A) ELISA Kit

Human Lipoprotein Lipase (LPL) ELISA Kit

Mouse Luteinizing Hormone (LH) ELISA

Mouse high density lipoprotein (HDL) ELISA Kit

HUMAN SOLUBLE NEUROPILIN 2 (snrp2) ELISA KIT

Pig vasoactive intestinal peptide (VIP) ELISA Kit

Mouse Myeloperoxidase (MPO) ELISA Kit

Human Mannma Binding Protein/Mannan Binding Lectin (MBP/MBL) ELISA Kit

Mouse Advanced Glycation End Products (AGEs) ELISA Kit

Mouse Osteoprotegerin (OPG) ELISA Kit

Mouse Cholecystokinin (CCK) ELISA Kit

Mouse Myelin Basic Protein (MBP) ELISA Kit

Mouse Cyclophilin A (CyPA) ELISA Kit

Rabbit immunoglobulin M(IgM) ELISA Kit

Human Phosphorylated Myosin Light Chain (PMLC) ELISA Kit

Human myeloperoxidase(mpo) ELISA Kit

Mouse dickkopf-related protein 3 (DKK3) ELISA Kit

CTRP15/MYONECTIN (HUMAN) ELISA KIT

Human Advanced Glycation End Products (AGEs) ELISA Kit

Mouse Tumor Necrosis Factor α (TNF-α) ELISA Kit

Mouse Fibroblast Growth Factor 8 (FGF8) ELISA Kit

Human myelin basic protein(mbp) antibody ELISA Kit

Human anti-granulocyte-macrophage colony stimulating factor (GM-CSF) antibody ELISA Kit

Human breast cancer susceptibility protein 2, BRCA-2 ELISA Kit

Human Glucose-6-Phosphate Dehydrogenase (G6PD) ELISA Kit

Mouse serine protease HTRA1 (HTRA1) ELISA Kit

Mouse D-Dimer (D2D) ELISA Kit

Mouse Neurotrophin 3 (NT-3) ELISA Kit

Mouse Cathepsin S (CTSS) ELISA Kit

Human Neurofilament Protein L (NF-L) ELISA Kit

Mouse Integrin Alpha-M (Itgam/CD11b) ELISA Kit

Mouse Matrix Metalloproteinase 1 (MMP-1) ELISA Kit

Mouse Glial Cell line-derived Neurotrophic Factor (GDNF) ELISA Kit

Mouse Ras-related Protein Rab-1A (RAB1A) ELISA Kit

PD-1 [Biotinylated] : PD-L1 Inhibitor Screening ELISA Assay Pair

Rat immunoglobulin D (IgD) ELISA Kit

Mouse Calcitonin Gene Related Peptide (CGRP) ELISA Kit

Duck Interleukin-4 (IL-4) ELISA Kit

Human procollagen type III (HPCⅢ) ELISA Kit

Mouse Proenkephalin A (PENK) ELISA Kit

Human Aldehyde Dehydrogenase (ALDH) ELISA Kit

Human hepatocyte growth factor receptor (c-met/ HGFR) ELISA Kit

Human Integrin Beta-1 (ITGB1) ELISA Kit

Human Vasoactive Intestinal Peptide (VIP) ELISA Kit

Rat Hypoxia-Inducible Factor 1α (HIF-1α) ELISA Kit

Human Prostaglandin D2 (PGD2) ELISA Kit

Human connective tissue growth factor (CTGF) ELISA Kit. MyBioSource.com. This package insert must be read in its entirety before using this product.

Goat immunoglobulin G (IgG) ELISA Kit

Human immunoglobulin M (IgM) ELISA Kit

Human CNTF ELISA Kit

Human Cyclin-Dependent Kinase Inhibitor 1 (CDKN1A) ELISA Kit

Human Motilin (MTL) ELISA Kit

Rabbit C-reactive protein(crp) ELISA Kit

Rat folic acid (FA) ELISA Kit

Mouse immunoglobulin M(IgM) ELISA Kit

Canine Relaxin (RLN) ELISA Kit

Rabbit matrix metalloproteinase 1 (MMP-1) ELISA Kit

Transcription:

Human CEACAM6 ELISA Pair Set ( CD66c ) Catalog Number : SEK10823 To achieve the best assay results, this manual must be read carefully before using this product and the assay is run as summarized in the General ELISA protocol. 1

BACKGROUND Carcinoembryonic antigen-related cell adhesion molecule 6 ( CEACAM6 ), also known as nonspecific crossreacting antigen (NCA) and CD66c, is one of seven human CEACAM family members within the immunoglobulin superfamily. CEACAM family members are a set of widely expressed proteins involved in several biological functions, including cell adhesion, migration, signal transduction, and the regulation of gene expression. Abnormal overexpression and downregulation of some CEACAMs have been described in tumor cells. Monoclonal antibodies grouped in the CD66 cluster recognize CEACAM members. Ectopic CD66 expression is commonly detected in B-cell lineage acute lymphoblastic leukemia (ALL). Human CEACAMs include type I transmembrane proteins (CEACAM-1, -3, and -4) and GPI-linked molecules (CEACAM- 5 through - 8). There is no human CEACAM-2. Human CEACAM6 is a GPI-linked membrane protein consisting of a signal sequence, an extracellular domain (ECD) containing one N-terminal V-type Ig-like domain and two C2-type Iglike domains, and a hydrophobic C-terminal propeptide. The GPI membrane anchor is attached at the C-terminus following cleavage of the propeptide. CEACAM-6 is expressed by granulocytes and their progenitors. It is also expressed by epithelia of various organs and is upregulated in pancreatic and colon adenocarcinomas, as well as hyperplastic polyps. Resistance to adhesion-related apoptosis in tumor cells is conferred in the condition of CEACAM6 overexpression. CEACAM6 is emerging as an important determinant of the malignant phenotype in a range of cancers. CEACAM6 plays a key role in pancreatic adenocarcinoma cellular invasiveness. Levels of CEACAM6 expression can modulate pancreatic adenocarcinoma cellular invasiveness in a c-src-dependent manner. This pathway warrants further investigation as a target for therapy. 2

PRINCIPLE OF THE TEST The Sino Biological ELISA Pair Set is a solid phase sandwich ELISA (Enzyme-Linked Immunosorbent Assay). It utilizes a monoclonal antibody specific for CEACAM6 / CD66c coated on a 96-well plate. Standards and samples are added to the wells, and any CEACAM6 / CD66c present binds to the immobilized antibody. The wells are washed and a biotinylated rabbit anti- CEACAM6 / CD66c polyclonal antibody is then added, producing an antibody-antigen-antibody sandwich. To produces color in proportion to the amount of CEACAM6 / CD66c present in the sample strepavidin- HRP and TMB substrate solution are loaded. The absorbances of the microwell are read at 450 nm. INTENDED USE The human CEACAM6 / CD66c ELISA Pair Set is for the quantitative determination of human CEACAM6 / CD66c. This ELISA Pair Set contains the basic components required for the development of sandwich ELISAs. ASSAY PROCEDURE SUMMARY Capture Antibody Analyte Biotinylated Detection Antibody HRP-conjugated Streptavidin This Pair Set has been configured for research use only and is not to be used in diagnostic procedures. 3

MATERIALS PROVIDED Bring all reagents to room temperature before use. Capture Antibody - 1 mg/ml of mouse anti-ceacam6 monoclonal antibody. Dilute to a working concentration of 2 μg/ml in PBS before coating. Detection Antibody - 0.4 mg/ml of biotinylated rabbit anti-ceacam6 polyclonal antibody. Dilute to working concentration of 0.5 μg/ml in detection antibody diluteion buffer before use. Standard - Each vial contains 88 ng of recombinant CEACAM6. Reconstitute standard powder with 1 ml detection antibody dilution buffer. A seven-point standard curve using 2-fold serial dilutions in sample dilution buffer, and a high standard of 1000 pg/ml is recommended. Streptavidin-HRP - 50 μl of streptavidin conjugated to horseradish-peroxidase. 1:2000 Dilution in detection antibody dilution buffer before use. SOLUTIONS REQUIRED PBS - 136.9 mm NaCl, 10.1 mm Na 2 HPO 4, 2.7 mm KCl, 1.8 mm KH 2 PO 4, ph 7.4, 0.2 μm filtered TBS - 25mM Tris, adjust ph to 7.4 by HCl Wash Buffer - 0.05% Tween20 in TBS, ph 7.2-7.4 Blocking Buffer - 2% BSA in Wash Buffer Sample dilution buffer - 0.1% BSA in wash buffer, ph 7.2-7.4, 0.2 μm filtered Detection antibody dilution buffer - 0.5% BSA in wash buffer, ph 7.2-7.4, 0.2 μm filtered. Substrate Solution : To achieve best assay results, fresh substrate solution is recommended Substrate stock solution - 10 mg/ml TMB ( Tetramethylbenzidine ) in DMSO Substrate dilution buffer - 0.05M Na 2 HPO 4 and 0.025M citric acid ; adjust ph to 5.5 Substrate working solution - For each plate dilute 250 μl substrate stock solution in 25ml substrate dilution buffer and then add 80 μl 0.75% H 2 O 2, mix it well Stop Solution - 2 N H 2 SO 4 PRECAUTION The Stop Solution suggested for use with this Pair Set is an acid solution. Wear eye, hand, face, and clothing protection when using this material. 4

STORAGE Capture Antibody: Aliquot and store at -20 to -80 for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles. Detection Antibody: Aliquot and store at -20 to -80 for up to 6 months from date of receipt. Avoid repeated freeze-thaw cycles. Standard: Store lyophilized standard at -20 to -80 for up to 6 months from date of receipt. Aliquot and store the reconstituted standard at -20 to -80 for up to 1 month. Avoid repeated freeze-thaw cycles. Streptavidin-HRP: Store at 4 and protect it from prolonged exposure to light. DO NOT FREEZE! It is stable for up to 6 months from date of receipt. 5

GENERAL ELISA PROTOCOL Plate Preparation 1. Dilute the capture antibody to the working concentration in PBS. Immediately coat a 96-well microplate with 100μL per well of the diluted capture antibody. Seal the plate and incubate overnight at 4. 2. Aspirate each well and wash with at least 300μl wash buffer, repeating the process two times for a total of three washes. Complete removal of liquid at each step is essential for good performance. After the last wash, remove any remaining wash buffer by inverting the plate and blotting it against clean paper towels. 3. Block plates by adding 300 μl of blocking buffer to each well. Incubate at room temperature for a minimum of 1 hour. 4. Repeat the aspiration/wash as in step 2. The plates are now ready for sample addition. Assay Procedure 1. Add 100 μl of sample or standards in sample dilution buffer per well. Seal the plate and incubate 2 hours at room temperature. 2. Repeat the aspiration/wash as in step 2 of plate preparation. 3. Add 100 μl of the detection antibody, diluted in antibody dilution buffer, to each well. Seal the plate and incubate 1 hour at room temperature. 4. Repeat the aspiration/wash as in step 2 of plate preparation. 5. Add 100 μl of Streptavidin-HRP to each well. Incubate for 1 hour at room temperature. 6. Repeat the aspiration/wash as in step 2 of plate preparation. 7. Add 200 μl of substrate solution to each well. Incubate for 20 minutes at room temperature ( if substrate solution is not as requested, the incubation time should be optimized ). Avoid placing the plate in direct light. 8. Add 50 μl of stop solution to each well. Gently tap the plate to ensure thorough mixing. 9. Determine the optical density of each well immediately, using a microplate reader set to 450 nm. CALCULATION OF RESULTS Calculate the mean absorbance for each set of duplicate standards, controls and samples. Subtract the mean zero standard absorbance from each. Construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. To determine the concentration of the unknowns, find the unknowns mean absorbance value on the y-axis and draw a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the x-axis and read the concentration. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor. Alternatively, computer-based curve-fitting statistical software may also be employed to calculate the concentration of the sample. 6

TYPICAL DATA This standard curve is only for demonstration purposes. A standard curve should be generated for each assay. PERFORMANCE CHARACTERISTIC SENSITIVITY The minimum detectable dose of human CEACAM6 / CD66c was determined to be approximately 15.6 pg/ml. This is defined as at least three times standard deviations above the mean optical density of 10 replicates of the zero standard. 7

TROUBLE SHOOTING Problems Possible Sources Solutions Incorrect or no Detection Antibody was added Add appropriate Detection Antibody and continue No signal Substrate solution was not added Add substrate solution and continue Incorrect storage condition Check if the kit is stored at recommended condition and used before expiration date Standard was incompletely reconstituted or was inappropriately stored Aliquot reconstituted standard and store at -70 Poor Standard Curve Poor detection value High Background Imprecise / inaccurate pipetting Incubations done at inappropriate temperature, timing or agitation Background wells were contaminated The concentration of antigen in samples was too low Samples were ineffective Insufficient washes TMB Substrate Solution was contaminated Check / calibrate pipettes Follow the general ELISA protocol Avoid cross contamination by using the sealer appropriately Enriching samples to increase the concentration of antigen Check if the samples are stored at cold environment. Detect samples in timely manner Use multichannel pipettes without touching the reagents on the plate Increase cycles of washes and soaking time between washes TMB Substrate Solution should be clear and colorless prior to addition to wells Materials were contaminated. Use clean plates, tubes and pipettes tips Non-specificity Samples were contaminated The concentration of samples was too high Avoid cross contamination of samples Try higher dilution rate of samples 8

Human CEACAM6 / CD66c ELISA Pair Set Fax :+86-10-58628220 Tel:+86-400-890-9989

Human CEACAM6 / CD66c ELISA Pair Set Notes