SS505 StoPoren Brick Veneer Construction 1

Similar documents
SS506 StoArmat Poren Brick Veneer System 1

A Sto QA Form is required to be filled out by the various parties involved for the Sto Warranty.

SS202 Sto Concrete Block Plaster System 1

SS806 StoStucco Roughcast System 1

SS909 StoProtect - Architectural Blocks 1

STOPOREN BLOCK VENEER CLADDING SYSTEM. Product. Scope. Appraisal No. 739 [2012] Appraisal No. 739 (2012) Amended 11 November 2015.

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

STOLITE STUCCO CLADDING SYSTEM. Product. Scope. Appraisal No. 468 [2018]

All work in this section shall be the responsibility of the Main Contractor, unless otherwise expressly agreed.

MLC MASONRY AND BRICK PLASTER SYSTEM. Product. Scope. Appraisal No. 839 [2013] Appraisal No. 839 (2013) BRANZ Appraisals

Limitations and Conditions

STOTHERM MASONRY INSULATION SYSTEM. Product. Scope. Appraisal No. 604 [2008] Appraisal No. 604 (2008) Amended 11 November 2015.

ROCKCOTE RESENE MONOTEK SYSTEMS

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

Product. BRANZ APPRAISAL No. 553 (2007) Scope. Nuplex Industries Ltd C/- Nuplex Construction Products PO Box Glenfield Auckland

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM. Product. Scope. Appraisal No. 501 [2017]

Product. BRANZ APPRAISAL No. 769 (2012) Scope. Celcrete International Ltd PO Box 2382 Tauranga

nu-therm system Product BRANZ APPRAISAL No. 456 (2005) Scope Nu-Age Plaster Limited P O Box 195 Matamata

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01.

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

nu-wall aluminium vertical cladding system

Product. BRANZ APPRAISAL No. 633 (2009) Scope. Rockcote Resene Limited PO Box Harewood Christchurch 8545

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3

Technical & Installation Manual

Product. BRANZ APPRAISAL No. 789 (2012) Scope. Hard as Rocks Ltd PO Box 1703 Taupo 1351

NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM. Product. Scope. Appraisal No. 556 [2007] Appraisal No. 556 (2007) Amended 20 November 2015.

All work in this section shall be the responsibility of the Main Contractor.

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM

STOTHERM INSULATED FACADE SYSTEM FOUNDATION SLAB-ON-GROUND

Product. BRANZ APPRAISAL No. 468 (2005) Scope. Stoanz Ltd 72 Abel Smith Street Wellington Tel: Fax: Internet:

nu-age nu-lite Product BRANZ APPRAISAL No. 459 (2004) Scope Nu-Age Plaster Limited PO Box 195 Matamata

FRAMEFLASH / WATERTIGHT FLASHING TAPE. Product. Scope. Appraisal No. 631 [2017]

STOTHERM MASONRY INSULATION SYSTEM DRAWING REGISTER

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

weathertex sheet Product BRANZ APPRAISAL No. 514 (2006) Scope Weathertex Pty Ltd P O Box 21 Raymond Terrace NSW 2324 Australia

enduron LWC Product BRANZ APPRAISAL No. 720 (2012) Scope Rockcote Resene Limited PO Box Harewood Christchurch 8545

Architectural Roofing

STOPOREN FACADE SYSTEM FOUNDATION SLAB-ON-GROUND

weathertex weatherboard direct fixed

MONOTEK SHEET - CAVITY CONSTRUCTION

0331 Brick and block construction

JENKIN A-LIGN BEVELBACK WEATHERBOARD DIRECT FIXED CLADDING SOLUTION

PUTZ TECHNIK SYSTEM 300

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

INTEGRA LIGHT WEIGHT CONCRETE FACADE SYSTEM. Product. Scope. Appraisal No. 681 [2010] Appraisal No. 681 (2010) Amended 06 March 2018.

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

Finish coat painted with a 100% acrylic. Multi purpose scratch coat

EZYCORNER CAVITY FLASHING. Product. Scope. Building Regulations. Appraisal No. 920 [2016] Appraisal No. 920 (2016) BRANZ Appraisals

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

BGC STRATUM AND STRATUM DUO CAVITY CLADDING SYSTEMS. Product. Scope. Appraisal No. 847 [2013] Appraisal No. 847 (2013) Amended 14 October 2015

TESCON EXTORA SEALING TAPE. Product. Scope. Appraisal No. 838 [2013] Appraisal No. 838 (2013) Amended 30 June 2017.

QUICKFLASH READY- MADE FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 688 [2018]

BGC DURAGROOVE AND DURASCAPE FACADE SYSTEMS (CAVITY) Product. Scope. Appraisal No. 799 [2013] Appraisal No. 799 (2013) Amended 14 October 2015

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

NZ Brick Distributors Canterbury Clay Bricks Clay Bricks Ltd Brick and Stone Imports T/A Midland Brick NZ Full contact details are given on page 9.

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

11/09/2018 LBP licence classes

THERMAKRAFT ALUBAND WINDOW FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 878 [2014]

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

DuPont Tyvek Wall Underlay Install Guide

WATERTIGHT ROOF UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 938 [2017] Appraisal No. 938 (2017) BRANZ Appraisals

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

CELCRETE PANEL VENEER SYSTEM TECHNICAL MANUAL. Product Description and Building System Details SEPTEMBER 2012

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz.

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

Stutex Stone Veneer Cladding System

Bituminous Building Paper

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

Commercial Flashing Details

INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL

PROTECTO TAPE FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 450 [2017]

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System

AquaFlash System Installation Guide DS196

Guide Specification for the OSI QUAD Window and Door Flashing System

UNITEX BASE BOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 758 [2011] Appraisal No. 758 (2011) BRANZ Appraisals

SMARTCLAD BEVELBACK WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 684 [2017]

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

EZpanel Autoclaved Aerated Concrete Panel Specification

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

Triclad Board (and Batten) June 2013

FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 800 [2013] Appraisal No. 800 (2013) Amended 05 February 2016.

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

STO POREN BRICK VENEER DRAWING REGISTER

ARDEX UNDERTILE SHEET MEMBRANE (WPM 750 AND WPM 1000) Product. Scope. Building Regulations. Appraisal No. 727 [2017]

Triclad Lapped Weatherboard June 2013

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Caparol System PRO Data sheet

Finish coat painted with a 100% acrylic. Multi purpose scratch coat

MASTERWALL INSULATED EXTERNAL WALL SYSTEM

For system application details, refer to the corresponding Baumit Method Statement before submitting a tender.

For system application details, refer to the corresponding Baumit Method Statement before submitting a tender.

Transcription:

SS505 StoPoren Brick Veneer Construction 1 STOPOREN BRICK VENEER CONSTRUCTION STOPOREN PLASTER ON POREN BRICK VENEER SPECIFICATION BRANZ Appraisal No 739 (2011) - ACAD Details www.sto.co.nz building with Sto Stoanz Ltd Authorized partner of Sto Project: Prepared for: StoPoren Brick Veneer Construction This specification details the construction of the Poren Brick Veneer and StoPoren Plaster System incorporating; Poren Brick Veneer on 40mm min Cavity Construction sealed with S-Protect WS 205 stay dry sealer, StoPoren meshed basecoat plaster, primed with Stoplex W sealer, finished in selected Stolit K coloured finishing render coated with StoColor Maxicryl facade paint, supported by timber frame construction built to the requirements of NZBC Acceptable Solution E2/AS1. 1. CONSTRUCTION Responsibility All work in this section shall be the responsibility of the Main Contractor, unless otherwise expressly agreed. The Main Contractor is to ensure that he or she is fully conversant with all Sto ACAD installation and fixing details (see www.sto.co.nz Building with Sto) and the Main Contractor s responsibilities before works commence. The Main Contractor is to be responsible for all liaison with the various sub contractors to ensure that all items relating to weather tightness of joints or connections affecting the Sto Plaster System are strictly in accordance with Sto ACAD standard or project specific details, i.e. items such as dissimilar materials junctions, electrical wiring, flashings, plumbing etc or any items that are adjacent or penetrate the substrate. The main contractor shall be responsible for ensuring all joinery is installed in accordance with Sto details by others before the Sto System has commenced. A Sto QA Compliance Form is required to be filled out by the various parties involved for the Sto Warranty. Timber Frame Timber framing must comply with NZS 3604 for buildings or parts of a building within the scope limitations of NZS 3604. Buildings or parts of a building outside the scope of NZS 3604 must be to a specific design in accordance with NZS 3603 and the AS/NZS 1170series. Studs must be at maximum 600 mm centres in Low, Medium, High and Very High Building Wind Zones and maximum 400 mm centres for Extra High Wind Zones and specifically designed buildings. Dwangs must be fitted flush between the studs at maximum 800 mm centres. All framing shall be true in vertical and horizontal planes with particular attention to intersections of top plate/floor joists/bottom plate in multi-storey construction. Adequate timber framing & blocking shall be provided by the Main Contractor to facilitate membrane up stands and exterior fixtures. The timber grade and level of treatment shall be in accordance with the latest requirements contained in NZBC Acceptable Solution B2/AS1 and NZS 3602, generally a minimum treatment level of H1.2 and an overall maximum moisture content of 24% prior to the cladding being installed. A concrete foundation is required for brick construction with a minimum 50mm high rebate and a minimum height of 150mm to unpaved ground or 100mm to paved surfaces from the top of the rebate.

SS505 StoPoren Brick Veneer Construction 2 Poren Brick Timber Lintel Spans See StoPoren ACAD details for Pryda or Mitek Flitch Beam span tables to meet NZS 3604. Note; Timber or laminated timber beams can be used but must be specifically engineered for the load and span. Wall insulation NZBC Acceptable Solution H1/AS1 or NZBC Verification Method H1/VM1 can be used for housing, communal residential, communal non-residential and commercial buildings. For buildings with a glazing area of 30% or less of the total wall area, the minimum wall R-values required for non-solid construction are: Climate Zone 1 & 2 R 1.9 and Climate Zone 3 R 2.0. The Thermal resistance of building elements is verified by using NZS 4214. The BRANZ House Insulation Guide Fourth Edition provides thermal resistances of common building elements based on calculations from NZS 4214. Wall Underlay A flexible wall underlay is suitable for use in NZS 3604 Wind Zones up to, and including, Very High. A rigid underlay is required in Extra High Wind Zones and specific design wind pressures. A wall underlay meeting the requirements of E2/AS1 shall be installed in strict accordance with the manufactures instructions. The wall underlay shall always be returned into the recesses of all openings and double lapped and flashing taped as per E2/AS1, WANZ or a BRANZ appraised wrap specification. Rigid wall underlay - Plywood or fibre cement sheet complying with NZBC Acceptable Solution E2/AS1 Table 23 or rigid sheathing materials covered by a valid BRANZ Appraisal for use as a rigid air barrier system. Note: Ensure any items requiring fixing or penetrating the timber frame such as fixing brackets etc are installed and flashing taped onto the building underlay in accordance with E2/AS1. Aluminum Joinery & Head Flashings The Aluminium joinery shall be fixed before the installation of the bricks. All windows, doors etc shall be fitted prior to installation of the bricks by the appointed window installer positioned to sit between 10mm and 20mm into the brick reveal line (cavity + 10-20mm). Where a WANZ joinery support bracket is used ensure that it finishes 10mm short of the joinery jambs. The proprietary aluminium head flashing is required to have a minimum 35mm up stand,15 degree slope, sit 2 x 10mm past the jambs (20mm total to cover the StoPoren Jamb flashings), have minimum 10mm stop ends that end in the cavity and 10mm cover over the joinery head. All Joinery is fitted before the Poren Bricks are installed and the StoPoren Sill & Jamb flashings and proprietary aluminium head flashing must be fitted as the bricks are installed. Note ensure the joinery edges are clean before adhering flashings in place and the head flashing up stand is flashing taped to the wall underlay. The Sto Adjustable foot tray with the extension leg is fitted at the flashing line for the Poren Lintel. Timber Frame Shrinkage An allowance must be made for timber frame shrinkage to the solid brick veneer. Generally allow 6.0 to 8mm at soffits that are filled with a polyurethane adhesive foam. Penetrations Penetrations such as waste pipes and fixing brackets shall be flashed with flashing tape to the wall underlay or the underlay backed by min 75mm blocking and the exterior pipe finished with a flange sealed in accordance with E2/AS1 Fig 68. All penetrations through the bricks shall be adequately sealed using MS Sealant installed over a backer rod. All electrical wiring etc shall only penetrate the cladding system with the appropriate sized upvc conduit installed at minimum 5º downwards rake. Plumbing piping should be set at a downwards rake and sealed using MS Sealant before plastering. NOTE: MAIN CONTRACTOR & ALL SUB TRADES INVOLVED IN ANY EXTERIOR WORK All Details must be in strict accordance with E2/AS1 and Sto standard or project specific details

SS505 StoPoren Brick Veneer Construction 3 2. POREN BRICK CONSTRUCTION Responsibility All the work in this section relating to the StoPoren Plaster System shall be the responsibility of the Sto Contractor including StoPoren flashings as required. The laying of the StoPoren Bricks is to be undertaken by a licensed building practitioner (LBP) brick layer who shall sign off the finished brick work on completion. The contractors must ensure adequate masking / protection of all adjacent dissimilar materials is undertaken before commencing. General The StoPoren Brick & StoPoren Plaster System installation incorporates the following; Poren Brick Veneer installation, S-Protect WS 205 stay dry sealer StoPoren meshed basecoat plaster, primed with Stoplex W sealer finished in selected Stolit K or MP coloured finishing render coated in StoColor Maxicryl facade paint. Materials Poren Bricks & Lintels 310mm Poren Shelf brackets Poren Mortar StoPoren PVC Lintel Heads or Drip Edges S-Protect WS 205 stay dry StoPoren meshed basecoat plaster Stoplex W sealer Stolit K or MP coloured finishing render StoColor Maxicryl facade paint StoFlexyl waterproofing Sto upvc joinery flashings, drip edges, S/S angles, pre meshed corners and control joints Poren Brick Installation (600 x 200 x 75) Install the Poren Bricks with a 5 to maximum 20mm overhang over the concrete foundation rebate (recommended rebate width minimum 125mm) to achieve a minimum 40mm cavity (maximum 75mm) from the supporting timber frame constructed to the requirements of NZS 3604. Reinforcement, Brick ties (minimum Grade EM), foundation weep holes (1000mm² per lineal metre min 8 x 75mm @ 600mm centre s) and mortar joints shall be made in strict accordance with the project specifications, drawings and Sto ACAD design and installation details. In particular the bricks shall be laid true, in both vertical and horizontal planes bedded in running bond StoPoren mortar with all joinery and services cut outs correctly made using Poren Brick Lintels or cladding infill s over any openings. Mortar joints should be 10mm+/-2mm tooled flush finish with the bricks squared off the foundation on a mortar course of up to 20mm. Suitable corrosion proof brick ties are required to be fully embedded in the mortar joints and installed minimum half way through the brick (max 15mm from exterior face) extending across the cavity to be screw fixed into the framing by minimum 35mm at approximately 5 per square metre - maximum 600mm centre s longitudinally (every stud) & minimum 400mm vertically (every second course) including 2 @ maximum150mm from control joint centres or as per the project specific details. As required install snake wire reinforcing at 800 centre s on corners, above large joinery openings, across narrow widths and at stress points. Care must be taken to avoid dropping mortar into the cavity by the employment of protection boards and cleaning of wash out openings at least daily to remove any mortar droppings. All bricks should be cut neatly with sills laid at a minimum 15 degrees incorporating a 30-50mm overhang if required. A curing time (normally 5/7days weather dependant) shall be allowed after placement, for curing and stabilization to take place, before application of the StoPoren Plaster System. All Maximum Tolerances shall be in strict accordance with NZS 4210: 2001 2.7.1.4 Table 2.2, i.e. No more than 3mm surface alignment deviation over a 1200mm radius. The Poren bricks shall be free of all surface contaminants and be dry enough to accept a sealer before plastering commences. The Main Contractor is to ensure that any areas or details adjacent to the bricks have been adequately waterproofed or flashed to avoid any water migration behind the system. Coastal Locations Coastal locations as defined in NZS 3604 as salt spray zone D and some Microclimatic conditions such as geothermal areas require corrosion proof lintels, Brick ties and screws as per E2/AS1 table 18C & D

SS505 StoPoren Brick Veneer Construction 4 Poren Steel Reinforced Lintels Poren Lintels are available in 200 x 75 x 2400mm size to span openings up 2000mm unsupported allowing for the minimum 200mm lintel / brick support on either side of the opening with two brick ties 150mm apart at the joins. Where openings are larger than 2000mm the Poren Shelf Bracket (galvanized 75h x 100d x 310mm brackets) are to be fixed to timber lintels using M10 x 75mm galvanized coach screws or M10 coach bolts for Fitch beams positioned as per the StoPoren Details. Poren Lintels are rebated for the shelf bracket and joined on the Poren Shelf Bracket with 10mm of Poren Mortar. Brick ties are required on top embedded in the mortar bed at minimum 600mm centre s with 2 x Brick ties at joins including ends placed 150mm apart. The Poren Shelf Bracket must extend across cavity to under seat the Poren Lintel by a minimum 55mm pack off frame as required and adjust coach fixings accordingly. Note; The StoPoren PVC Adjustable Foot is used to finish the underside of the lintel. To install fit vented cavity base with extension leg glued in to align with underside of lintel after shelf brackets have been fitted, position lintel and push adjustable front of foot in place and glue adhere before plastering Narrow Widths & Stress Points As required on narrow widths or stress points such as adjacent to garages, large openings, apexes etc extend the Poren Lintel 600mm past the stress point see Sto Poren ACAD Details. Sealant All junctions between the brick and adjacent dissimilar material surfaces shall be flashed by the main contractor and detailed and sealed using MS Sealant over PEF rod. The sealant must be applied in accordance with the manufactures TDS sheet instructions. S-Protect WS 205 stay dry All dry Poren Brick surfaces must be treated with a sealer coat of S-Protect WS 205 stay dry at 4-5 square metres per litre applied with low-pressure garden sprayer or block brush on dry clean bricks and lintel surfaces and left to dry for 24 hours before plastering. Control Joints Based on Australian Building Code for Brick Veneers. Control joints as designated by the project drawings, engineer or Sto details must be incorporated in the brick cladding and capped using Sto PVC Control Joints. Vertical control joints are normally required every 6 metre s on walls preferably above and below joinery openings, where the height of the wall changes by more than 20%, at foundation expansion joints and dissimilar material junctions see the Sto Poren ACAD details for specific design. Either side of the control joint is reinforced with brick ties placed a maximum 150mm from the joint at maximum 400mm horizontal centres. Aluminium Joinery Ensure all joinery is flashed accordingly as previously detailed before commencing. 3. STOPOREN PLASTER SYSTEM StoPoren meshed basecoat plaster To clean, dry brick surfaces apply a basecoat of StoPoren plaster by hawk and trowel at approximate thickness of 2.5mm. While the StoPoren plaster is still wet, lightly embed Sto Mesh, ensuring adjacent drops of mesh are overlapped by a minimum of 75mm, lightly float the surface to ensure that the mesh has been embedded onto the basecoat and use Sto pre meshed corner angles on all external corners. Allow to dry and apply one further coat of StoPoren at approximately 1.5mm by hawk and trowel to leave an even straight plane surface free of hollows and deviations. Note: Any narrow widths or stress points require additional mesh butterflies on top of the mesh coat. Once dry remove any ridging etc of finished surface with a Sto rasp ready for subsequent topcoat.

SS505 StoPoren Brick Veneer Construction 5 Plastered Wall Caps All plastered horizontal surfaces must have a minimum 10º fall (sills 15º fall). On plastered parapets or balustrades caps Sto Flexyl must be correctly mixed (drill mix 1/1- with fresh cement) and applied with a layer of Sto mesh embedded into the StoFlexyl which is then floated to a level surface attaining a total minimum film thickness of 1-1.5mm. Extend membrane 75 mm up or down adjacent vertical surfaces and allow to dry overnight. Apply StoFlexyl waterproofing over the StoPoren meshed basecoat before the second coat to avoid a shadow line. Note: StoFlexyl waterproofing has been evaluated by BRANZ to meet the AS/NZS 4858 waterproof membrane requirement as required by E2/AS1. Stoplex W sealer To clean and dry StoPoren plastered surfaces; apply a sealer coat of Stoplex W sealer by brush and roller at the approximate spreading rate of 8m²/litre to seal the plastered surface. Sealant Installation After the sealer has dried, all junctions between joinery and adjacent dissimilar surfaces and the Sto Plaster and around penetrations details shall be sealed with MS Sealant. Architectural Profiles Any Architectural shapes used to create detailing shall be correctly cut to size and fitted using Gluecoat Mortar applied to the back of the shape with a notch trowel prior to placing. Fixings may be used to position shapes correctly or for mechanically securing large profiles. Profiles are placed after the reinforcement mesh coat and are edge meshed on to the surface at the perimeter junction. Finishing Section - select finish Stolit K coloured finishing render as selected Stolit K texture is available in a flat 1.0mm, 1.5mm or 2.0mm aggregate plaster To all exterior plastered surfaces apply selected finishing render Stolit K tinted to the selected colour, applied with a stainless steel trowel gauging to the thickness of the aggregate size and finished with a plastic trowel to the requisite pattern and allow to dry normally overnight. The spreading rate shall be approximately 12sqm/1.0mm, 9sqm/1.5mm, 7sqm/2.0mm-/per pail. StoColor Maxicryl façade paint All Stolit K surfaces shall receive one (1) full coat of StoColor Maxicryl façade paint tinted to the selected colour and applied by brush and roller at approximately 6/7 m² per litre. Note: Always maintain wet edges between cutting in and rolling in tight to ensure an even film build is maintained. ALTERNATIVE SELECTION Stolit MP or MP Natural coloured finishing render Stolit MP or MP Natural are fine pre coloured sponge finishes applied in two (2) tight coats. A basecoat of Stolit MP or MP Natural or alternatively depending on finish Stolit K 1.0 or 1.5mm tinted to the selected colour is applied and allowed to dry before the finishing coat of Stolit MP or MP Natural is applied and float finished or randomly lightly sponged to the selected pattern. The spreading rate of the Stolit MP is approximately 12 16sqm -per pail. S-Protect SC stay clean sealer To Stolit MP Apply an even coat of S-Protect SC stay clean Silane sealer ( clear invisible sealer) in a flood coat using a low pressure garden sprayer and Sto brick brush to work the product into the Stolit plaster wiping off any lingering drips etc. Surfaces must be well coated and work in a pattern preferably out of the sun to ensure that there are no misses as the sealer is invisible once dry.

SS505 StoPoren Brick Veneer Construction 6 Note: S-Protect SC stay clean all joinery and glazing must be completely masked off to prevent the glazing being damage and any excess product must be removed or polished into the surface during application to avoid a surface film forming. 4. GENERAL NOTES Colour As selected by the client or specifier Stoanz Limited recommends that the selected colour should have an Light Reflectance Value of 20% or greater to avoid thermal stress. If a colour is selected outside of this recommendation, the warranty offered may be affected. 5. MAINTENANCE Refer; Sto Maintenance Schedule for comprehensive guide The Sto Plaster System must be cleaned annually by washing to remove all existing surface contaminants with special attention to non-rain washed areas. When recoating is required at the 7/8- year period to maintain long-term integrity and a pristine condition this can be carried out using the appropriate Sto coating over a cleaned surface. Physical damage must be repaired using the appropriate Sto Plaster materials as required. Where a colour change is required, Stoanz Limited should be consulted for a specific specification. Annual inspections are to be implemented after completion to clearly identify any faults in the cladding, sealant beads, flashings and any other connections. A repair process must be implemented immediately to address any faults so the long-term warranty is not compromised. 6. WARRANTY The StoPoren Brick Veneer System described in this specification is warranted for a period of fifteen (15) years from the date of practical completion. This is to comply with the relevant clauses in the New Zealand Building Code; B1 Structure, B2 Durability, E2 External Moisture and F2 Hazardous Building Material for this type of building element provided normal maintenance requirements as set out in the Sto Maintenance Schedule are followed. The warranty is supplied by the Sto Contractor on completion and includes a five (5) year workmanship warranty signed by the Sto Contractor carrying out the work. The warranty is issued and backed by the Stoanz Limited as to the suitability of the material supplied provided that; (a) All specified work is carried out by the approved Sto Contractor who must complete and sign the Sto QA Compliance Procedure Forms and a PS3 Workmanship Warranty (b) All work is carried out in accordance with this Specification or any written amendments issued by the Manufacturers. (c) The warranty does not cover situations where the plaster system is subjected to physical disturbance, chemical spillage or interference.