CONTINUOUS VENTILATORS

Similar documents
TYPICAL ROOF CONDITION LAYOUT

Ridgepac. Small Ridge Mounted Natural Ventilator Ventilation's Natural Solution since 1961

MoffittVent. Large Natural Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL 32250

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

SHURLOC 150 STANDARD DETAILS

SECTION ROOF ACCESSORIES

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

a division of NCI Standing Seam Roof Systems

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

Covering Design Regions

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

ACCESSORIES TABLE OF CONTENTS

SECTION METAL ROOF AND SOFFIT PANELS

SECTION LOUVERS AND VENTS

Architectural Wall Products Guide Specifications

SECTION STAINLESS STEEL WALL PANELS

Built to Last a Lifetime

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

Pre-Fabricated Roof Curbs

Architectural Roof Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

TRIAD CORRUGATED METAL, INC.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SLOPED ROOF. Ajustable sloped flashing from : 2/12 to 7/12 Ventilation area : 50 to 250 ft. 2

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Metal Building Roof Curbs

S BI COM P ON E NT CA T ALOG

10200/ARR Buyline 4822 ARROW LOUVERS. The Preferred Line PUBLICATION

SECTION AWNINGS

SECTION ROOF SPECIALTIES

Architectural Roof Products Guide Specifications

PRE-ENGINEERED METAL BUILDING SYSTEM

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

ABSeam Panel Overview and Installation Instructions

Ameriplate. Rain Screen Wall System

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

INSTALLATION MANUAL Heritage Series

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

TRIAD CORRUGATED METAL, INC.

EVERSEAM 20 APPLICATION GUIDE

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

Ameriplate. Rain Screen Wall System

HEAVY STEEL CONSTRUCTION

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

Malarkey s well-designed, competitively-priced Endura products can assist with completing projects ON TIME AND ON BUDGET.

Sheet Metal Flashing and Trim

DETENTION / SECURITY WINDOWS SECTION 08660

SECTION NON-STRUCTURAL METAL FRAMING

Proposal for Garage Shell Kit. 25 wide by 35 long Pre-Engineered Building Components. April 19, 2017

SECTION AIR OUTLETS AND INLETS

Tuscaloosa Police Station

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

SECTION PRE-ENGINEERED METAL BUILDING

SECTION ALUMINUM STORM WINDOWS

PRODUCT DESCRIPTION ACCESSORIES. Canopies

Approaching towards innnovation. An ISO 9001:2015 Certified company

INSTALLATION MANUAL KOCH

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

ABS Pre-Fab Building S ystem

C. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.

Light-Metal Roof Edge, Raised

7000 Series Curtain Wall Information Specifications

4 EXTREME FOUNDATION PANELS

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

SECTION SECTIONAL OVERHEAD DOORS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

FABRAL The pursuit of excellence since 1967

BARREL VAULT Tile Counter Batten and Batten Installation Guide

Superior Structural Standing Seam Roof Systems

Storage Bins of Any Size For All Your Needs.

Operable / Fixed Skylight Milgard Aluminum Window

SECTION SECTIONAL OVERHEAD DOORS

SECTION EXTERIOR GRILLS AND SCREENS

SECTION HVAC GRAVITY VENTILATORS

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents

Residential Building Inspections

Fascia Systems. oofing 7.1

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION PRE - ENGINEERED METAL BUILDING MATERIALS

DL-200. Specifications

SECTION SECTIONAL OVERHEAD DOORS

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING

SECTION METAL BUILDING SYSTEMS. A. Section Placement of anchor bolt, leveling plates, and grout.

SECTION CHAIN LINK FENCING

SHEET METAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Transcription:

CONTINUOUS VENTILATORS used on metal roofing systems roofs conform to high standards and specifications which have been developed, tested and proven over many years. They provide an excellent value for the user. Standard Size 9" throat and 12" throat 10 foot sections. Other sizes available upon request. Low profile design can be used for single unit or continuous run installation with no disassembly. Integral Dampers Easy-moving damper opens to any degree from fully open to completely closed. Design Aerodynamically proportioned to exclude weather protects air passages and full outlet area. Bird Screen Fully protected by 4 x 4 mesh galvanized hardware cloth. Construction Durable 26 gauge exterior combined with internal components of 24, 20 and 18 gauge die formed sheet metal and machined parts for long service life. Finish Pre-painted or galvalume is standard. Other materials and finishes available upon request. Drainage Area Continuous slot bottom of both sides of windbands. Ventilators are manufactured in accordance with the highest design requirements and specifications. 40 plus years of experience in furnishing stationary, gravity-flow, continuous ridge ventilators has proven their efficient performance and lasting quality. A properly engineered ventilation system using continuous ridge ventilators will control the movement of fresh air through the building removing hot, stale air and air contaminated by manufacturing or production processes. Summer heat is released naturally through gravity ridge ventilators. During winter proper ventilation can assist in the control of condensation and other CV-01 / Rev. 8/01 BUILDINGS MUST BREATHE! moisture problems, such as rust and deterioration of insulation or the damage to stored products. Our ridge ventilator is a low-profile design manufactured in 10-foot lengths which can be installed as individual units or in continuous runs. Vents may be furnished with or without dampers to control the flow of air. Operation of dampers is standard by pull chains (Please specify when ordering), multiple damper operation is available for up to 5 or more units. Ventilators are shipped with a 1:12 end cap and can be field modified to accommodate up to a 6:12 roof pitch. Innovation. New Technology. Better Products. 18933 Aldine Westfield Houston, TX 77073 Phone 281-443-9065 Fax 291-443-9064 888-GO-RIGID www.rigidbuilding.com

DIMENSIONS AND TECHNICAL DATA B BIRD SCREEN A DIE-FORMED BAFFLE RAIN SHIELD DAMPER LIFTER ARM SADDLE STRAP SIDE SKIRT THROAT D E C DIMENSIONS (In Inches) Throat* A B C D E 9 13 21 1 4 14 1 2 18 28 1 4 *12 17 28 1 2 18 22 33 SHIPPING WEIGHTS Size Boxed Standard Crated Pkg. Size 9" 124 lbs 209 lbs 124 1 2" X 19 1 2" X 30 1 2" 12" 148 lbs 218 lbs 124 1 2" X 23" X 35" * Other sizes available upon request. TURNBUCKLE PULL BAR END CAP OF VENT END CAP OF VENT END CAP OF VENT POP RIVET END CAP TO DRAIN ASSEMBLY STOVE BOLT PULL BAR CONNECTION: Install turnbuckles between adjacent pull bars. With the dampers in the closed position, adjust turnbuckles starting at one end of the run. NOTE: BREAK DRAIN ASSEMBLY TO FOLLOW EXACT ROOF SLOPE. DRAIN AT MULTI- UNIT SPLICE ROOF PANEL MAJOR RIB DRAIN AT CAP OF END VENT ROOF PANEL MAJOR RIB RAIN SHIELD DAMPER END CAP RAIN SHIELD DAMPER END CAP PIVOT BRACKET & SADDLE STRAP PULL BAR PULLEY AT FRAME OR WALL LIFTER ARM GUIDE ROD SPRING PIVOT BRACKET & SADDLE STRAP PULL BAR LIFTER ARM GUIDE ROD SPRING PULL BAR IN CLOSED POSITION TO CLOSE DAMPER, PULL CABLE STANDARD CABLE OPERATION 2" TRAVEL CHAIN CATCH (OPT.) CHAIN WITH HANDLE OPTIONAL PULL CHAIN OPERATION (SINGLE UNITS ONLY) PULL CHAIN MUST BE REMOVED FOR CONTINUOUS RUN OPERATION Chain-operated damper utilizes a rugged sash chain through chain locking device. Damper is spring-loaded to open and can be adjusted to any opening from fully open to fully closed. Optional operator packages for multiple units or wall operation are available. (See below.) PERFORMANCE DATA Throat Size Vent Above Ground CFM 10' 1323 20' 1890 9" 30' 2241 40' 2511 10' 1764 20' 2520 12" 30' 2988 40' 3348 Assumes 10 Temperature differential and 5 mph wind speed PIVOT ANGLE CLAMP EYEBOLT GIRT LEVER HANDLE FOR CONTINUOUS RUNS UP TO 5 UNITS s S HOOK COLUMN PLATE WELDED TO COLUMN BOAT WINCH FOR CONTINUOUS RUNS UP TO 10 UNITS Innovation. New Technology. Better Products. 18933 Aldine Westfield Houston, TX 77073 Phone 281-443-9065 Fax 291-443-9064 888-GO-RIGID www.rigidbuilding.com

9" CONTINUOUS VENTILATOR SPECIFICATIONS Ventilators are of low profile design to provide gravity type ventilation. Birdscreen is provided to prevent nesting and each unit contains flashing for either single unit or continuous-run installation. Each unit is 9" x 10' with a base ventilating capacity of 2700 CFM at 20 temperature differential with a 25' stack height. Exterior parts are 26GA. G90 galvanized, painted galvanized or galvalume. ASTMA446. Interior parts are all of G90 galvanized steel. Substructure consists of 10GA. saddle straps with interior baffles of 24GA. Pull bars and pivot brackets are of 20GA. Lifter arms and damper slides are of 18GA. Manual operation is through activation of pull bar, which is attached to bell-cranked type lifter arms connected to damper with teflon coated pins through damper slides. Dampers are spring loaded to remain in open position until pull bar is operated and locked in the closed position. Dampers operate in vertical manor. Birdscreen is 4x4 mesh galvanized hardware cloth. Innovation. New Technology. Better Products. 18933 Aldine Westfield Houston, TX 77073 Phone 281-443-9065 Fax 291-443-9064 888-GO-RIGID www.rigidbuilding.com CV-01.1 / Rev. 8/01

B A C THROAT DIMENSIONS (In Inches) Throat A B C D E D E 4 6 1 4 12 1 2 9 10 18 9 13 21 1 4 14 1 2 18 28 1 4 12 17 28 1 2 18 22 33 18 26 3 4 45 5 8 30 5 8 30 49 24 33 1 2 57 38 3 8 36 1 8 58 1 8 36 47 1 2 81 1 4 53 5 8 55 83 1 2 SHIPPING WEIGHTS Size Boxed Standard Crated Pkg. Size 9" 124 lbs 209 lbs 124 1 2" X 19 1 2" X 30 1 2" 12" 148 lbs 218 lbs 124 1 2" X 23" X 35" 8/18/99 DIMENSIONS CV-01.2 / Rev. 6/02 CONTINUOUS VENT VS-1

WELDED FRAME RIDGE VENTILATORS B E F BIRD SCREEN EXTERIOR FRAME RAIN SHIELD SIDE D J M INTERIOR FRAME G L SADDLE STRAP C SKIRT H K A (THROAT) P NOTE: EXTERIOR AND INTERIOR FRAME MADE OF 1 8" X 1 1 2" X 1 1 2" ANGLE HOT-DIPPED GALVANIZED AFTER WELDING. ALL OTHER PARTS MADE OF 22 GA. SHEET METAL, STANDARD WHITE OR GALVALUME. WELDED FRAME VENTILATOR DIMENSIONS A A/2 B C D E F G H J K L M N P WT. 15 7 1 2 39 26 1 2 8 22 3 4 11 3 8 11 3 8 9 7 8 5 6 1 2 7 1 2 16 7 8 8 25 18 9 45 5 8 30 5 8 10 5 8 26 3 4 13 3 8 13 3 8 11 5 7 8 8 1 4 9 18 5 8 9 1 2 30 275# 20 10 49 32 5 8 10 1 4 28 3 4 14 3 8 14 3 8 11 3 8 8 9 1 8 10 17 3 4 9 33 24 12 57 38 3 8 11 7 8 33 1 2 16 3 4 16 3 4 13 5 8 8 1 8 9 1 4 12 21 1 2 11 36 1 8 324# N 30 15 70 1 8 45 9 16 14 3 8 41 20 1 2 20 1 2 14 9 1 2 11 5 8 16 26 5 8 11 3 8 49 1 4 36 18 81 1 4 53 5 8 16 7 8 47 1 2 23 3 4 23 3 4 19 1 2 12 3 8 12 1 2 18 26 1 2 14 1 4 55 428# 42 21 94 61 18 7 8 56 26 13 16 26 5 16 22 1 2 14 1 2 13 9 16 21 31 1 4 16 5 8 62 48 24 106 65 7 8 19 1 4 67 1 4 27 1 4 27 1 4 26 7 8 16 7 8 13 5 16 24 34 1 8 20 1 8 67 1 2 550# Purlin Spacing = P Plus 3" Each Side 9/20/99 DIMENSIONS WELDED FRAME CONTINUOUS VENT CV-01.3 / Rev. 9/99

Table of Capacities for Continuous Ventilators MP CAPACITY: To determine capacity per unit, multiply Base Rating by Temperature-Height Factor : CFM = Base x Temperature-Height Factor Based on fresh air intake area 1 1 /2 times ventilator throat area. Assumes 5 mph wind speed. Temperature-Height Factors Temperature Difference Base Ratings Height 5 10 15 20 25 30 35 40 45 Size C.F.M. 10'.37.49.58.64.70.76.81.86.95 4" 1200 15'.42.60.71.80.86.92.99 1.05 1.09 9" 2700 20'.53.70.81.92.99 1.07 1.14 1.22 1.26 12" 3600 25'.58.77.89 1.00 1.08 1.18 1.25 1.33 1.39 15" 4500 30'.63.83.97 1.08 1.17 1.28 1.36 1.45 1.50 18" 5400 35'.66.87 1.02 1.14 1.24 1.35 1.44 1.51 1.58 24" 7200 40'.70.93 1.08 1.22 1.30 1.41 1.50 1.61 1.68 30" 9000 45'.74.96 1.12 1.28 1.38 1.48 1.59 1.68 1.75 36" 10800 50'.77 1.01 1.18 1.33 1.44 1.56 1.67 1.75 1.83 42" 12600 55'.80 1.06 1.23 1.39 1.50 1.64 1.72 1.83 1.92 48" 14400 60'.83 1.09 1.28 1.44 1.55 1.69 1.79 1.90 2.00 65'.85 1.12 1.32 1.48 1.61 1.74 1.85 1.97 2.06 70'.88 1.17 1.36 1.53 1.67 1.79 1.89 2.02 2.11 75'.90 1.19 1.39 1.57 1.69 1.83 1.96 2.06 2.17 80'.93 1.22 1.42 1.61 1.72 1.86 2.00 2.11 2.20 Height = vertical rise from inlets near floor to ventilator. Temperature = estimated temperature difference between middle of air intake near the floor and ventilator with dampers open. CV-01.4 / Rev. 8/99

END CAP OF VENT DRAIN AT MULTI-UNIT SPLICE (WEEP) CAULK HERE END CAP OF VENT DRAIN AT END OF VENT CAULK HERE POP RIVET END CAP TO DRAIN ASSEMBLY ROOF PANEL MAJOR RIB ROOF PANEL MAJOR RIB NOTE: BREAK DRAIN ASSEMBLY TO FOLLOW EXACT SLOPE OF ROOF SIDE SKIRT NOTES: BE SURE WEEPS ARE LEFT OPEN FOR 5:12 AND UP ROOF PITCHES, THE TWO BOTTOM RIVETS MUST BE REMOVED BEFORE END SKIRT MAY BE PLACED ON VENT. REPLACE RIVET WITH SCREW. RIDGE VENT FLASHING WITHOUT DIE-FORMED SKIRTS FASTENER CV-01.6/ Rev. 03/00 END VIEW CLOSURE WITH SEALANT T&B 1/4/99 FLASHING WITHOUT DIE-FORMED SKIRTS CONTINUOUS VENT DRAWING #2

CONTINUOUS VENTILATOR DIE-FORMED SKIRT END SKIRT DETAIL AND CONTINUOUS VENT SPLICE CHANNEL SUPPORT END CAP OF VENT END CAP OF VENT CHANNEL GUTTER TAPE SEAL ROOF PANEL GUTTER SUPPORT END OF VENT DETAIL CV-01.7 / Rev. 03/00 4/22/97 DIE-FORMED SKIRT APPLICATION CONTINUOUS VENT VFSS-1

CONTINUOUS VENTILATOR FLAT SKIRT CLOSURE (Not by MP) END OF VENT DETAIL END CAP OF VENT DRAIN AT END OF VENT POP RIVET END CAP TO DRAIN ASSEMBLY CAULK HERE END CAP OF VENT ROOF PANEL MAJOR RIB END SKIRT DETAIL AND CONTINUOUS VENT SPLICE CLOSURE (Not by MP) DRAIN AT MULTI-UNIT SPLICE CAULK HERE ROOF PANEL MAJOR RIB 4/22/97 FLAT SKIRT APPLICATION CONTINUOUS VENT CV-01.8 / Rev. 03/00

BIRD SCREEN DAMPER GUIDE ROD BAFFLE RAIN SHIELD DAMPER DAMPER SLIDE LIFTER ARM SADDLE STRAP PIVOT BRACKET 6:12 5:12 4:12 3:12 2:12 END CAP PUNCH MARKS FIELD CUT BLIND RIVETS (2) REQ D FOAM CLOSURE END SKIRT PEAK PANEL THROAT SKIRT OPERATOR BAR RAIN SHIELD DAMPER END CAP END CAP DETAIL NOTE: DOTTED LINE INDICATES FIELD CUT FOR 6:12 ROOF SLOPE. OTHER SLOPES AS NOTED. ROOF PITCH LESS THAN 1:12 INSTALLATION: INSTALL END SKIRT FOR 1:12 ROOF SLOPE AND FOAM CLOSURE WITH TAPE SEALER TOP AND BOTTOM. ROOF PITCH GREATER THAN 5:12 INSTALLATION: REMOVE TWO BOTTOM RIVETS BEFORE INSTALLING END SKIRT. REPLACE THE RIVETS WITH SHEETING SCREWS ONCE END SKIRT IS IN PLACE. PIVOT BRACKET & SADDLE STRAP PULL BAR PULLEY AT FRAME OR END WALL LIFTER ARM GUIDE ROD SPRING PULL BAR IN CLOSED POSITION TO CLOSE DAMPER, PULL CABLE STANDARD CABLE OPERATION 2" TRAVEL PULL BAR CONNECTION DETAIL RAIN SHIELD DAMPER END CAP PIVOT BRACKET & SADDLE STRAP PULL BAR LIFTER ARM GUIDE ROD SPRING CHAIN CATCH (OPT.) CHAIN WITH HANDLE OPTIONAL PULL CHAIN OPERATION (SINGLE UNITS ONLY) PULL CHAIN MUST BE REMOVED FOR CONTINUOUS RUN OPERATION 1/04/99 INSTALLATION DETAILS FLAT SKIRT CONTINUOUS VENT CV-01.9 / Rev. 03/00

OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER OPERATOR C: HAND LEVER TYPE OPERATOR D: BOAT WINCH TYPE CV-01.11 / Rev. 10/83 3 UNITS MAX. 3 UNITS MAX. 6 UNITS MAX. 12 UNITS MAX. OCT. 1, 1983 END WALL INSTALLATION CONTINUOUS VENT VEW-1

OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER OPERATOR C: HAND LEVER TYPE OPERATOR D: BOAT WINCH TYPE CV-01.12 / Rev. 10/83 2 UNITS MAX. 2 UNITS MAX. 5 UNITS MAX. 10 UNITS MAX. OCT. 1, 1983 SIDE WALL INSTALLATION CONTINUOUS VENT VSW-1

WORM GEAR ASSEMBLY CONTINUOUS VENT CV-01.13 / Rev. 10/83

LOW PROFILE FLOATING RIDGE VENT RIDGE LINE...featuring Cor-A-Vent ventilation core is designed specifically for architectural standing-seam retrofit applications and some residential applications where maximum ventilation is required in an attractive, very low-profile unit. Standard Size Each ten-foot unit features 180 square inches of free area with a base rating of 450 CFM s of air movement. Units in lengths of other than ten feet can be manufactured upon request. Throat size is determined by roof pitch. Design Aerodynamic, low-profile design enhances the looks and performance of architectural roof systems. The unit moves toward the ridge on floating roofs. Vents are made to match roof slope to maintain low-profile appearance. Construction Unit is factory assembled and ready for installation. Vent features the Cor-A-Vent ventilation core a time-tested, economical, self-cleaning and durable core which has been in service since 1970. All steel parts are 24 gauge. Finish Steel parts match roof type and color finish. All paint types and colors are available including Kynar. Please specify roof system, paint system and color when ordering. One of the most overlooked components of design and installation of architectural roofing systems, both in new construction and retrofit applications, is ventilation. A properly engineered ventilation system using a continuous ridge vent in conjunction with an under soffit intake will provide proper fresh air movement through the roofing system removing hot, stale air. Summer heat is released naturally, extending both the life and performance of the roof. During winter proper ventilation can assist in the control of condensation and other moisture problems such as rust and insulation deterioration. Our idge ventilators are manufactured in accordance with the highest design requirements and specifications. 40 plus years SV-01 / Rev. 2/01 BUILDINGS MUST BREATHE! of experience in furnishing stationary, gravity-flow, continuous ridge ventilators has proven their efficient performance and lasting quality. Lo-profile floating ridge vents are a low-profile, aesthetically pleasing and extremely efficient means of ventilating standing seam roofs. Each unit is manufactured in 10' lengths and can be installed as a single unit or can be butted together to form a continuous run. By lapping the furnished joint covers over the top of the butted joints in a continuous run, the vent has the appearance of a single unit. When ordering please specify roof slope, roof system, paint system, and color. Innovation. New Technology. Better Products. 18933 Aldine Westfield Houston, TX 77073 Phone 281-443-9065 Fax 291-443-9064 888-GO-RIGID www.rigidbuilding.com

DIMENSIONS AND TECHNICAL DATA Ventilation Core Floating Ridge Cap Ventilation Core Skirt Floating Ridge Cap Ventilation Core Skirt 31 2" A 1 2" 3" 12 Existing Roof System * ROOF SLOPE 8 1 2" 5 1 2" SECTION A 1 1 8" 1" Existing Roof System 2" Closure Strip THROAT * NOTE: Throat Varies with Roof Slope TABLE A Air Movement per Lineal Foot Factors HEIGHT Temperature Difference IN FEET 5 10 15 20 25 30 10 16.65A 22.05A 26.10A 28.80A 31.50A 34.20A 15 18.90A 27.00A 31.95A 36.00A 38.70A 41.40B 20 23.85A 31.50A 36.45A 41.40A 44.50B 48.15B 25 26.10A 34.65A 40.05A 45.00B 48.60B 53.10C 30 28.35A 37.35A 43.65B 48.60B 52.65C 57.60C 35 29.70A 39.15B 45.90B 51.30B 55.80C 60.75C 40 31.50B 41.85B 48.60B 54.90C 58.50C 63.45C 45 33.30B 43.20B 50.40B 57.60C 62.10C 66.60C 50 34.65B 45.45B 53.10C 59.85C 64.80C 70.20D Note: If material is furnished by customer, the following must be supplied for each 10' section: Painted Screws 1 Sheet for Metal Roof, 2 for Shingle 15 Self-Tapping Screws 1 4" x 1 1 2" Type A W/Washers TABLE B Wind Velocity Factors WIND Factors M.P.H. A B C D 3 1.14 1.09 1.05 1.02 5 1.25 1.18 1.13 1.09 7 1.41 1.29 1.22 1.16 9 1.62 1.43 1.33 1.25 11 1.82 1.57 1.43 1.32 TOTAL CFM = (Table A) X (Table B) X Length TABLE C Throat Size (Determined by Roof Pitch) Pitch Throat Size Pitch Throat Size 1:12 6 1 2" 7:12 4 1 8" 2:12 6 1 8" 8:12 3 1 2" 3:12 5 5 8" 9:12 3" 4:12 5 1 4" 10:12 2 1 2" 5:12 4 7 8" 11:12 2 1 8" 6:12 4 5 8" 12:12 1 3 4" Innovation. New Technology. Better Products. 18933 Aldine Westfield Houston, TX 77073 Phone 281-443-9065 Fax 291-443-9064 888-GO-RIGID www.rigidbuilding.com

NOTE: DO NOT CUT ANY SLOTS IN THE EXISTING DECK ONE TRUSS BAY EITHER SIDE OF A DRAFT BARRIER WALL. THROAT VARIES WITH ROOF PITCH 8 1/2" NOTE: RIDGE VENT OPENINGS WILL REQUIRE SPECIAL ATTENTION TO AVOID INTERRUPTION OF ANY FIRE WALL INTEGRITY FLOATING RIDGE CAP VENTILATION CORE 2" 8 1/2" 1 1/8" 5 1/2" 6" 2" SHINGLES CUT SLOTS STAGGERED EACH SIDE OF RIDGE BEAM 7 1/2" MIN. 10/12/98 1:12 TO 5:12 PITCH SHINGLE TYPE CORAVENT SV-01.1 / Rev. 03/00

NOTE: DO NOT CUT ANY SLOTS IN THE EXISTING DECK ONE TRUSS BAY EITHER SIDE OF A DRAFT BARRIER WALL. THROAT VARIES WITH ROOF PITCH 10 1/2" NOTE: RIDGE VENT OPENING WILL REQUIRE SPECIAL ATTENTION TO AVOID INTERRUPTION OF ANY FIRE WALL INTEGRITY FLOATING RIDGE CAP VENTILATION CORE 2" 8 1/2" 1 1/8" 5 1/2" 6" 2" CUT SLOTS STAGGERED EACH SIDE OF RIDGE BEAM SHINGLES 7 1/2" MIN. 10/12/98 6:12 TO 12 :12 PITCH SHINGLE TYPE CORAVENT SV-01.2 / Rev. 3/00

NOTE: DO NOT CUT ANY SLOTS IN THE EXISTING DECK ONE TRUSS BAY EITHER SIDE OF A DRAFT BARRIER WALL. 10" 10" NOTE: RIDGE VENT OPENINGS WILL REQUIRE SPECIAL ATTENTION TO AVOID INTERRUPTION OF ANY FIRE WALL INTEGRITY FLOATING RIDGE CAP VENTILATION CORE 2" 8 1/2" 1 1/8" 5 1/2" 2" SHINGLES 3 3/4" MIN. 10/12/98 ROOF TO WALL SHINGLE TYPE CORAVENT SV-01.3 / Rev. 03/00