NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

Similar documents
NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

138 H-STUD AREA SEPARATION WALL SYSTEM

Cavity ShAftwall System

Area Separation Walls

The GlasRoc Shaftliner Type X advantage...

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Area Separation Walls

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

SECTION GYPSUM BOARD SYSTEM

SECTION GYPSUM BOARD SYSTEM

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

I-STUD Shaftwall System

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Shaftwall and Area Separation Wall Systems.

GAF EnergyGuard Polyiso Wall Sheathing

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION NON-STRUCTURAL METAL FRAMING

Chapter 14 - Air Sealing

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

SECTION NON--STRUCTURAL METAL FRAMING

GYPSUM BOARD

LEGACY REPORT Reissued October 1, Legacy report on the BOCA National Building Code/1999

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

SECTION GYPSUM BOARD ASSEMBLIES

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

I-STUD Shaftwall System

Duct Wrap Flexible Wraps

SECTION GYPSUM BOARD

SoundBreak Gypsum Board

SHAFTWALL & AREA SEPARATION WALL SYSTEMS PRODUCT CATALOG

Building Reputations Together. DensGlass. Shaftliner for Area Separation Walls

SECTION GYPSUM BOARD PART 1 - GENERAL

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

SHAFTWALL AND AREA SEPARATION WALL SYSTEMS

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Ash Brook Golf Course Scotch Plains, New Jersey

Gold Bond BRAND Kal-Kore Plaster Base

SECTION GYPSUM BOARD ASSEMBLIES

Gold Bond BRAND Gypsum Sheathing

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

UL Design System HW-D-1012 continued

Student Services & Classroom Addition

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

The System U.S. Patent No. 5,913,788

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

GYPSUM BOARD AND PLASTER

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems

R-Matte Plus-3: Insulation for the Building Envelope

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

SECTION GYPSUM BOARD

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION GYPSUM BOARD

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

Foil Back Gypsum Board

SECTION THERMAL INSULATION

Stark Truss Company, Inc. Revised December 14, 2018

CODE COMPLIANCE, STRENGTH AND SAVINGS IN ONE PANEL

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

ThermaSteel Corporation ASSEMBLY MANUAL

2012 & 2015 International Building Code. Section Section Section 713.4

GypWall QUIET Acoustic separating wall system

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

High Flex Gypsum Board

SECTION GYPSUM BOARD ASSEMBLIES

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

PinkWood Ltd. Revised September 29, 2017

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

GA APPLICATION OF GYPSUM SHEATHING

NEWS LETTER MARCH 27, 2009

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets

Impression Graphic panels

Boise Cascade Company Revised June 25, 2018

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

Ice Rink Renovation & New Clubhouse

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

SAMPLE CONSTRUCTION SPECS 2011 Conspectus, Inc. SECTION GYPSUM BOARD ASSEMBLIES

InterHome SEPARATING WALL SYSTEM FOR MULTI-RESIDENTIAL CONSTRUCTION

Transcription:

0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit between studs and a minimum / in. (. mm) air space on each side. Typical Floor/ Ceiling Juncture. H-Stud. Two Layers " Shaftliner XP. Stud. Gypsum Board. Double C-Track (Back to Back). Bottom Plate. Rim Joist. Top Plate. Subfloor 0. Minimum /" Air Space. Fire Blocking " Fire-Shield Shaftliner or Mineral Wool. ASW Clip 0 Minimum /" Air Space National Gypsum Company Construction Guide Rev. 0/0

NATIONAL GYPSUM COMPANY -Hour Description Technical Data National Gypsum Company produces three shaftliner products for use in the : Gold Bond brand Fire-Shield Shaftliner consists of a fireresistant Type X gypsum core encased in a heavy, moisture-resistant and green paper that is made from 00-percent recycled content. Gold Bond brand XP Shaftliner consists of a mold-, mildew-, moisture- and fire-resistant Type X gypsum core with a specially designed PURPLE paper that offers superior resistance to mold and mildew. Gold Bond brand exp Shaftliner consists of a fire-resistant Type X gypsum core encased in a coated, specially designed PURPLE fiberglass mat facer for superior mold, mildew and moisture resistance. The steel H-Studs are attached on each side to adjacent framing with aluminum ASW break-away clips. The clips melt when exposed to heat and allow the collapse of the fire-exposed unit without failure of the area separation wall. The H-Studs are secured at the foundation by the flanges of the C-Track. The same track is used back-to-back at intermediate floors to provide a splicing means so that the system can be erected one floor at a time. C-Tracks are also used at the roof line or at the parapet and at the ends of walls. For a -hour, fire-rated assembly without the need for battens, maintain a minimum / in. (. mm) air space between the H-Stud assembly and any adjacent framing members. When you cannot maintain a minimum / in. (. mm) air space, cover the H-Studs and C-Tracks by gypsum board battens. In lieu of battens, fasten gypsum board to the H-Studs, and treat joints with tape and joint compound to provide a finished wall surface. Wood- or steel-stud flanking walls on each side of the area separation wall system can be load-bearing and can accommodate mechanical, electrical and plumbing systems. Install mineral wool or glass fiber insulation to provide higher STC ratings. The has a non-bearing wall rating of hours and is listed in the UL Fire Resistance Directory as Design No. U and in the GA-00 Fire Resistance Manual as file numbers ASW 000, ASW 0 and ASW 0. The has been evaluated for code compliance in UL Evaluation Report UL ER R0-0. The may be built up to a maximum of ft. (0. m) high. Do not use the where exposure to constant dampness and/or water may occur. Although steel framing and Gold Bond brand exp Gypsum Panels can withstand temporary exposure to moisture during construction, protect the finished wall as soon as possible. Protect insulation in the Wall from getting wet. Do not install until the building is enclosed. Properly store materials supplied to the jobsite, support off the ground, and protect from inclement weather. Installation. Attach in. (0. mm) C-Tracks to the top of the foundation / in. (. mm) from the adjacent framed wall with fasteners spaced in. (0 mm) o.c. Apply acoustical sealant along edges of track to minimize sound transmission.. Install C-Track on the ends of stepped foundation walls aligned with the Wall and, if applicable, with fasteners in. (0 mm) o.c. Caulk edges as with the floor track.. At the intersection of foundation and the exterior wall, begin erecting Wall by inserting first layer of in. (. mm) shaftliner into C-Track. Insert second layer back-to-back with first layer and seat into C-Track. Shaftliner and studs may be set into position from the basement floor or fed down through the space provided between the wood framing from the floor above. Cap the terminating edge of the shaftliner panels with a vertical C-Track at the end of the foundation and fasten to the floor track with / in. (. mm) Type S pan-head screws. Rev. 0/0 National Gypsum Company Construction Guide

Wall Limiting Heights. Roof. H-Stud. Two Layers " Shaftliner XP. Minimum /" Air Space. Double C-Track (Back-to-Back). Fire Blocking " Shaftliner XP or Mineral Wool. Top Plate. Stud. ASW Clip 0. Blocking. XP Gypsum Board. Bottom Plate. Rim Joist. Finish Floor. Subfloor. Concrete Slab 0 ' Walls For walls up to ', space clips a maximum of 0' o.c. ' Walls For walls up to ', space clips a maximum of ' o.c. for wall sections below the upper '. ASW Clip C-Track H-Stud ' Walls For walls up to ', space clips a maximum of " o.c. for wall sections below the upper '. National Gypsum Company Construction Guide Rev. 0/0

NATIONAL GYPSUM COMPANY -Hour. Insert an H-Stud into the C-Track and engage the H-Stud flanges over the long edges of the shaftliner panels, making sure that both pieces of shaftliner are seated all the way into the C-Tracks and that their edges are flush. Seat the H-Stud fully so the board edges contact the stud web.. Continue in this manner, alternating two layers of shaftliner and H-Studs with the flanges of the H-Studs engaging the shaftliner edges until the wall is completed. Again, make sure all studs and boards are tightly pushed together. H-Studs may be fastened to C-Track with / in. (. mm) Type S pan-head screws to assist with installation.. Where the Wall forms a corner, cap the ends of the shaftliner panels with a vertical C-Track and fasten to the floor track with / in. (. mm) pan-head screws. Fasten a C-Track to the foundation or floor at a right angle to the installed Wall with fasteners in. (0 mm). Fasten the web of another vertical C-Track to the flange of the installed vertical C-Track capping the edges of the shaftliner panels with / in. (. mm) pan-head screws in. o.c. to create the corner. Continue installing shaftliner panels and H-Studs in the same manner.. If the Wall terminates at a foundation wall, insert the last two shaftliner panels from the floor above. Boards are pushed down into the channel formed by the flanges of the previous H-Stud and the flanges of the wall track.. If the Wall terminates at or past a framed wall, insert the last shaftliner panels and cap the end of the Wall with in. (0. mm) C-Track. Fasten C-Track flanges at all corners on both sides with / in. (. mm) Type S pan-head screws.. Where one unit extends past the adjacent unit, there are two methods for constructing the Wall. The first option is to continue the Wall to the farthest point of the building. Fasten / in. (. mm) plywood or OSB to the H-Studs with Type S screws in. (0 mm) to apply vinyl siding or cement board siding. The second option is to terminate the Wall at the end of the common wall and construct a -hour wall to the farthest point of the building. 0. Where one unit extends vertically past the adjacent unit, extend the Wall to the uppermost point of the building. Fasten / in. (. mm) plywood or OSB to the H-Studs with Type S screws in. (0 mm) to apply vinyl siding or cement board siding.. Cap the top edge of the erected wall with in. (0. mm) C-Track over studs and Shaftliner. C-Track may be fastened to H-Studs with / in. (. mm) Type S pan-head screws to assist with installation.. Where another Wall intersects the installed area separation wall, fasten a C-Track to the foundation or floor at a right angle to the installed Wall with fasteners in. (0 mm). Attach the web of a vertical C-Track to the flange of an H-Stud with / in. (. mm) pan-head screws in. (0 mm) o.c. Continue installing shaftliner panels and H-Studs in the same manner.. Attach H-Studs to adjacent framing with ASW clips. Fasten the clips to the H-Studs with one / in. (. mm) Type S pan-head screw through the short leg of the clip. Attach the ASW clips directly to the H-Studs or through the gypsum board battens to the studs. Attach clips to adjacent framing with one -/ in. (. mm) Type W screw for wood and Type S screw for steel.. Maintain a minimum / in. (. mm) air space between the H-Stud assembly and any adjacent framing members. When you cannot maintain a / in. (. mm) air space, cut gypsum board batten strips from pieces of / in. (. mm) Fire-Shield or / in. (. mm) Fire-Shield C Gypsum Board and install over H-Studs and C-Tracks. in. (. mm) wide battens are installed over C-Track at foundation and roof. in. ( mm) wide battens are fastened to the H-Studs with in. (. mm) Type S screw in. (0 mm) o.c. screwed into alternate flanges of the H-Studs.. Attach in. (0. mm) C-Track to the installed track capping off the wall of the lower floor. This back-to-back track installation allows you to erect the Wall one floor at a time. Secure the two tracks together with two / in. (. mm) Type S pan-head screws in. (0 mm) o.c. Stagger back-to-back track joints a minimum of in. (0 mm). Rev. 0/0 National Gypsum Company Construction Guide

Basic Components of Wall. " C-Track. " Shaftliner XP. " H-Stud. /" Fire-Shield C Gypsum Batten. For applications where a floor overhangs the floor below, the C-Track can be cantilevered in. (0 mm) from the C-Track, capping the wall of the lower floor. A in. ( mm) cantilever can be achieved in the same manner when diagonal steel strapping is applied to each side of the wall.. For additional vertical sections, erect shaftliner and H-Studs in the same manner as the basement wall, steps -0, except that starting and ending procedures vary depending on the exterior wall intersection detail.. At the roof intersection, cap the walls with C-Tracks abutting the underside of the roof sheathing. C-Tracks can be fastened to H-Studs with / in. (. mm) Type S pan-head screws to assist with installation. Fasten H-Studs to framing with ASW clips at the roof line.. Provide fire blocking at intermediate floors, roof locations, and horizontally every 0 ft. (,0 mm). Use mineral wool, gypsum board or non-combustible, spray-firestop sealants. 0. The in. (0. mm) Wall system can be finished in a variety of ways, depending on wall installation. Wood stud or steel stud walls flanking the Wall may be finished in any method specified. Where appearance is not critical and flanking walls are not installed, the Area Separation Wall and battens may be left unfinished. Recommendations Order H-Studs and in. (. mm) Fire-Shield Shaftliner according to the following:. Basement wall section length equal to distance from foundation to approximately in. (. mm) above the first floor line.. Intermediate floors length equal to the distance between floor lines.. Top floor or attic length to extend to top of parapet wall or to roof intersection, depending on detail. National Gypsum Company Construction Guide Rev. 0/0

NATIONAL GYPSUM COMPANY -Hour ft. Cantilever ft. Cantilever. " C-Track. " H-Stud. " Fire-Shield Shaftliner. Double C-Track (Back-to-Back). " C-Track. " H-Stud. " Fire-Shield Shaftliner. Diagonal Steel Strap. Double C-Track (Back-to-Back) 0 Max. s '0" 0'0" '0" Max. 0'0" Corner Detail. Gypsum Board. x Wood Stud. Insulation. Minimum /" Air Space. "Fire-Shield Shaftliner. " C-Track. " H-Stud. ASW Clip -Way Intersection Detail. Gypsum Board. x Wood Stud. Insulation. Minimum /" Air Space. " H-Stud. " C-Track. "Fire-Shield Shaftliner Rev. 0/0 National Gypsum Company Construction Guide

Roof Junction Detail Roof Parapet Detail. Roof Deck. x Wood Ledger. " C-Track. Gypsum Board or. ASW Clip. Minimum /" Air Space. "Fire-Shield Shaftliner. /" Fire-Shield Gypsum Board, ' Each Side When Roof Deck is Not Constructed With Fire-Retardant Treated Wood.. Roof Deck. " C-Track. Gypsum Board or. Minimum /" Air Space. ASW Clip. " Fire-Shield Shaftliner Dimension as Required by Code Exterior Wall Junction Detail. Siding. /" Fire-Shield Gypsum Sheathing, ' Each Side. Insulation. x Wood Stud. " C-Track. Gypsum Board or. Minimum /" Air Space. "Fire-Shield Shaftliner. ASW Clip 0. " H-Stud. Gypsum Board 0 Exterior Wall Intersection Detail. Siding. /" Fire-Shield Gypsum Sheathing. Insulation. x Wood Stud. " C-Track. Gypsum Board or. Minimum /" Air Space. " Fire-Shield Shaftliner. ASW Clip 0. " H-Stud. Gypsum Board Dimension as Required by Code 0 s Foundation Detail Floor Intersection Detail. Gypsum Board. x Wood Plate. Insulation. Minimum /" Air Space. "Fire-Shield Shaftliner. Sealant. " C-Track. Fasteners " o.c. Max.. Subfloor. Sealant. " Wood Plate. Gypsum Board. Insulation. Minimum /" Air Space. Rim Joist. Gypsum Board or. "Fire-Shield Shaftliner 0. ASW Clip. x Wood Stud. Ceiling 0 National Gypsum Company Construction Guide Rev. 0/0

NATIONAL GYPSUM COMPANY -Hour Notes: s 0 Rev. 0/0 National Gypsum Company Construction Guide