ECON OPPORTUNITIES, INC. 230 NORTH 5 TH STREET, Suite 300 READING, PA I hereby submit the results of my review of the new software program

Similar documents
NEW HOME ENERGY SAVINGS PROGRAM

NEW HOME ENERGY SAVINGS PROGRAM

The Numerous Benefits of Energy Efficient Practices

FOR ADDITIONS and REMODELS Before filling out this application, read Green Building & Green Points Guideline Booklet for more in-depth information.

About Active Energy Engineering

Equipment Sizing: Manuals J & S

Instant discount of 33% off improvement cost, up to $1,250 Plus, potential savings bonus of up to $250 (**)

Least Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates)

The Numerous Benefits of Energy Efficient Practices

Home Improvement Energy Tax Credits Explained

2012 CLEAResult All rights reserved. Residential Energy Efficiency

The Role of Energy Codes in Public Policy. A White Paper by the Northwest Energy Codes Group

Analysis of Energy Savings and Incremental Construction Costs for New Single Family Homes in Houston, TX under the 2012 IECC

Consumer Energy Tax Credit

Section 8 Energy and Energy Conservation

Energy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling

Nancy Kinner Donna Miller David Wetherbee Bath, ME June 24, 2018

Home Energy Score. Learn more at homeenergyscore.gov. Uses more energy. Uses less energy Milvia Street Berkeley, CA 94704

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC

escore Overview Page 1 of 5

Florida HERO Program Residential Eligible Product List All Products

Kansas City Residents Buying 2012 IECC Homes Will Save Thousands

Ductless Heat Pump Program Guidelines

Energy Merit Badge Workbook

HVAC Sizing: Flaws and Fudging

U.S. Department of Energy, in conjunction with the U.S. Environmental Protection Agency. Home Performance with ENERGY STAR

HOME ENERGY SURVEY 3/6/2014. PREPARED FOR: Martha Stewart 78 Maple St. Alden, IL PREPARED BY: Johnny Tester on behalf of CLEAResult

IECC Residential Significant Changes Summary. Tier I

R15: Potential Study. Introduction. Introduction. Study Components 3/7/2016

Measure 1 Seal Ducts Components Inspected

Orlando Utilities Commission

Getting to Net Zero Energy and Water Use and Beyond In Existing Multifamily Buildings

3/6/2017 Past president & currently on the board of directors for the Wisconsin Geothermal Association

SCPPA Efficiency Services and Products RFQ 2 June 7, 2018 & amended June 14, Areas of Interest

Trends in Green Remodeling

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Energy Rating Index Performance Path Fact Sheet Development

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Multifamily Net Zero Retrofit Market: Technical and Cost Benchmarks for San Francisco

Sustainability and Energy Use

Chapter Four: Green Remodeling Illustrations

Energy Savers: Air-Source Heat Pumps

Energy Assessment Report Clayville Elementary School DRAFT October George Washington Highway, Clayville, RI DRAFT

Truing-Up to Billing Data

Energy Savings Audit

Home Energy Assessment Rebate Guide

FLORIDA BUILDING CODE Energy Code (Residential) 6 TH Edition (2017) Chapter 1 [RE]: Scope and Administration

For more information about Ground Source Heat Pumps, call the Member Service Department at or visit our website at

building energy efficiency standards CALIFORNIA ENERGY COMMISSION

County of Perth. Energy Conservation and Demand Management Plan

ANALYSIS OF THE CONSERVATION AND ENERGY EFFICIENCY TAX PROVISIONS IN THE ENERGY POLICY ACT OF 2005

Home Energy Score Report

Let Geo LEED the Way. 1

REQUEST FOR PROPOSALS ENERGY AUDIT GASTONIA HOUSING AUTHORITY MARCH 23, 2009

Dayton Chapter February 9, Bob Thomson, P.E., LEED-AP, CDT

Houstonians Buying 2012 IECC Homes Will Save Thousands

Comprehensive Energy Audit For Kongiganak Health Clinic

Analysis and Implications of California s Long Term Energy Efficiency Strategic Plan for Existing Homes

Energy & Cost Savings Analysis of 2009 IECC Efficiency Improvements

Results and Recommendations from Energy Audit of Nikolai. For VEEP Grants. City of Nikolai, Alaska

California HERO Program Residential Eligible Product List All Products

Energy Performance Certificate (EPC)

Reducing Costs with Energy Efficiency

Energy Inventory Student Pages

Energy Savings Progress

Baker Neighborhood Energy Efficiency Workshop B A K E R H I S T O R I C N E I G H B O R H O O D A S S O C I A T I O N

Whole House HERS Ratings (and Raters)

The Ins and Out s of Financing Residential Energy Efficient Retrofits

currently referenced throughout the

A 92 plus B C D 55-68

Final 2016 UDRH Inputs: Addendum to Massachusetts Single- Family Code Compliance/Baseline Study DOCUMENT TITLE.

Heat Pump. Using Propane Heating Systems

MOISTURE CONTENT ACKNOWLEDGEMENT FORM Sec R I, am the general contractor or the ownerbuilder at the following address: Street Address.

SCHAEDLER YESCO ENERGY EFFICIENT TECHNOLOGIES

Upgrading To An A-Rated Home

FEBRUARY 22, GREEN BUILDING: Past, Present and Future

A 92 plus B C D E F 21-38

Your Zero Energy Ready Home Story

Energy Savers: Tax Credits for Energy Efficiency

Heat Pumps Community Workshop Manchester Library, Manchester

Meeting AB 32 Cost-Effective Green House Gas Reductions in the Residential Sector

Energy Performance Certificate (EPC)

01 March Mr. Tripp Coston Florida Public Service Commission 2540 Shumard Oak Blvd Tallahassee, Florida

JOIN US IN THE FIGHT AGAINST CLIMATE CHANGE

The Sustainable Development Fund in 2011

Leveraging Funds for Green Affordable Housing

Energy Performance Certificate

Using Solar Energy: A Hot Technology That s Cool

California Multi-Family New Homes

A 92 plus B C D E F G 1-20

Duke Energy Corporation

2018 Smart Energy New Homes Program Manual

Tools for sustainable development: a comparison of building performance simulation packages

MSc in Energy BUILDING ENERGY MANAGEMENT

Connecticut Housing Finance Authority. Construction Guidelines: Energy Conservation 2019

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Energy Performance Certificate

Results and Recommendations from Energy Audit of Kipnuk. For VEEP Grants. City of Kipnuk, Alaska

Transcription:

ECON OPPORTUNITIES, INC. 230 NORTH 5 TH STREET, Suite 300 READING, PA 19606 To: Whom It May concern August 31, 2010 RE: Findings Review of New HVAC Software Program Dear Mr. Vice President: I hereby submit the results of my review of the new software program Summary of Findings. I have investigated the partially completed computer program being prepared by Idea Tree of York, Pennsylvania for your possible use. I was given complete access to the program under development, called for the sake of this report, the Utility Model. Based on my observations and prior experience, I find the Utility Model to be an excellent analytical tool for home energy use and a potentially powerful marketing product for your use superior to any other currently on the commercial market. I have found that the Utility Model can calculate the reasonable use of energy in most homes quickly, economically and technically based. It is flexible enough to account for the normal variations of energy use that cannot be calculated without expensive and time consuming optimization. As intended, the Utility Model can be used by lightly trained marketing personnel to calculate existing and proposed energy uses (and costs) for a wide variety of improvement projects or proposals. It will be necessary for you to finalize the variety of improvement projects calculated, the constriction costing involved and the formats of the final outputs of the Utility Program before it can be deployed. I have included some thoughts as to how this may be accomplished, In conjunction with the discussions below and without any knowledge of the economics involved, I recommend that you seriously consider the purchase/licensing of the Utility Model and the completion of all programming to achieve a complete, useable, and working product. 1

Actions Taken. As part of the evaluation process of the Utility Model, I have taken the following steps: 1. Purchased and reviewed the Air Conditioning Contractors of America (ACCA) Manual J Residential Load Calculation by Hank Rutkowski, P.E., eight edition, version two. This manual is the basis for most of the calculations used in the Utility Model. 2. Travelled to the offices of Idea Tree in York, Pennsylvania on two occasions. I met with the COO and senior programmer for the Utility Model. We discussed the history of the model and its current widespread use by contractors across the county. He set up a separate computer for my use and testing of the current version of the program. I put the model through a series of program changes to see if the results were in keeping with my expectations they were. 3. Accompanied an HVAC serviceman to two homes in the area. Observed the steps taken to prepare an energy audit for a Community Assistance Program including boiler testing, blower door testing, assessment of windows, insulation, air leakage, lighting, etc. The audit was very professional and thorough for the guidelines of the program. 4. Received a computer link to and tested the latest version of the Utility Model from Idea Tree (on my office computer). I tested it using my own home s specifications and energy costs. I found the output of the Utility Model to be a reasonable match to my home s natural gas heating bills. I was able to input most U values. The accessing by the model to Google maps, Zillow, NOAA weather and other default values was fast and clever. This link model was only set up to evaluate geothermal heat pump options (not others). Existing Computer Model. The existing Utility Model is under development and is not complete. Idea Tree is currently working to complete sections of the model to meet your requirements. The model is an adaptation of the commercial model currently used by hundreds of contractor members of ACCA. The ACCA model uses the Manual J Residential Load Calculation methods described therein. The existing Utility Model consists of some 10,000 lines of PHP language programming instructions. These instructions or code perform the calculations of maximum energy use (design heat loss and heat gain) according to Manual J. In addition the model calculates annual energy use from retrieved weather data based 2

on NOAA locations nearest the home being investigated. The code uses BIN data and not heating or cooling degree day methods. The resulting calculation findings are not displayed for observation or checking unless specifically requested for output. Thus it was not possible for me to see the heat loss calculation results for windows, walls, roof, floors, air changes, etc. It is not possible for me to read PHP language and thus I was only able to verify final output cost values currently displayed by the existing program. It is possible to program these output values each time they are needed but I feel this will not be necessary for the final product. The existing model is capable of calculating energy use for space heating and air conditioning of a home including all of its components windows, walls, floors, roof, air changes, building orientation (to the sun), doors, furnace efficiency, fuel type, duct losses and a number of smaller items. These calculations can be for both the existing home and revised energy uses if specific parameters are changed for proposed projects. For example if a new heating system (or a part of the home changed) is proposed, the program can calculate old energy use, proposed energy use and annual energy savings just for the heating system. The existing model contains a feature called a slider or a button that can moved by a mouse on the input page of the program. The purpose of the slider is to easily adjust the calculated energy consumption of the existing home to more closely match actual energy use and corresponding savings. The slider actually changes the inside occupied temperature of the home from the default setting either up or down as the slider is moved on the input page. The actual temperature finally selected by the slider and used in the calculations is not shown but is a reasonable method to compensate for the many unknowns that occur. The Utility Model that I used was set up for geothermal heat pumps. I did not see outputs for conventional furnaces or high efficiency boilers or water heaters. I also did not see the output for sizing of conditioning equipment. I believe both exist in other similar Idea Tree models, but did not review these steps. Uncompleted Model Features. At the time of my evaluation, the program was being developed to evaluate other options besides heating and cooling systems. I have seen some of your specifications but would like to outline 3

what I feel are important areas of other potential program improvements for houses. 1. New windows. 2. Attic insulation. 3. Wall insulation 4. Boiler tune-up 5. Fuel change oil to gas, electric to gas, etc (if available). 6. Digital setback thermostats. 7. Domestic hot water heaters electric to gas 8. Weatherization reducing air changes. 9. Efficient lighting compact fluorescents or LEDs. 10. Appliances Energy Star. The savings for each of the above would have to be built into the model calculations. The construction costs of each of the above would have to be built into the output of the models. It is assumed that your company would want to determine these costs. The possible energy grants available (federal, state, utility) and tax deduction values for each of the potential improvements would have be determined by your company. The total economic impacts of performing the recommended projects in simple payback period format and/or life-cycle impact could be shown. It may not be possible to identify other benefits in calculations but mentioning benefits such as reduced cash flow, reduced maintenance costs, reduced deferred replacement cost, improved home value, etc. The amount of energy quantity reductions and reduction in pollution (greenhouse gases by type) may be possible. The existing model does not have a final report output (format) from the calculations at this time. It is understood that your company is considering such report content and presentation possibilities. Once the calculations are programmed it is a straightforward step to complete the output format. Possible Additional Features. If actual prior energy usage and costs for both fuel and electricity are available prior to visiting a customer and presenting a report, this information could be contained in the 4

report. For example, if your company has access to a customer s utility bills for the preceding year this can be presented. If not available it may still be beneficial to present calculated or estimated annual energy usage and costs for the entire home (and not just the heating and cooling costs). Such information in the report will create strong credibility and enhance the marketing process. If available, it may be advantageous to show numerically or graphically the performance of the home in question against national averages. For instance it may be possible to show the actual EUI (Energy Utilization Index) of the home in btus/sf versus low medium-high averages for the area. Or it may show on a scale of 1 to 10 the energy performance of the home versus the range of home usage (or cost). Of course low performance would be a good motivator to make proposed improvements. It may also be beneficial if the report can generate a reasonable breakdown of a home s existing performance (costs) by major categories by fuel as shown below. This would reveal the room for improvement. Natural Gas: Space heating Domestic Hot Water Cooking Clothes Drying Other Summary of All users Electricity: Heating Air Conditioning Lighting- Indoor and Outdoor Domestic Water Heating Cooking Clothes Drying Refrigerator(s) TVs & Small Appliances Computers Other Summary of All Users The program will have no trouble calculating costs and savings of single improvement projects one by one. There may be complications if two projects compete for the same or part of the same savings called interactive savings. For instance, if there is a recommendation to replace oil with natural gas and also installing a new gas furnace. The program could have problems giving a priority to which project gets all of the 5

savings and which one does not. The easy way out is to say at the outset that the report findings do not include interactive savings at this time. It is good policy to have a statement of accuracy in the report to cover variations that cannot be known in advance or in the future. Such variations may be the result of conditions not addressed in the calculations such as: Number of occupants full time or temporary Length of time of occupancy full or partial Comfort level Desired some like it hot, some prefer lots of fresh air, etc. Maintenance levels for equipment and structures Location factors such as top of hill, shade from trees Home arrangement such as split level, semi-detached, two floor, additions, etc. The model does not account for these now. Specialized energy users such as pools, wood stoves, fireplaces, welding equipment, extra freezers, space heaters, multiple computers, large screen TVs, etc. Unknown construction factors such as wall and ceiling insulation. While the purpose of the report is to present opportunities for energy and cost savings, it is likely that there will be projects that are not recommended. The report may want to state that certain improvements were investigated but are not recommended by your comapny at this time. The report can either list the titles of those not recommended or show the costs involved to be more convincing. The report should also clearly state that solar panels for either hot water or photovoltaic reasons were not investigated and are not normally recommended by your company. The same would be true for wind electricity generation. Report Output Discussion. I would like to see on the report output the design loads of the home in btu s per hour and not just the annual costs. This would provide a reasonable check of the recommendation as it pertains to heating and cooling. 6

This report is not intended to propose specific formats of program outputs. There are a few comments that may help the final results of the program. It may help to have an overall summary of results tabulated at the beginning of the report including recommended and not recommended projects. For each specific project it may be helpful to have more description, perhaps a paragraph, of what is being proposed. If there is a picture or a diagram showing what equipment is involved it will help the customer. I suggest that all pages of the report have page numbers and dates shown. I suggest that all numbers and costs shown have commas (thousands). The present program does not. I suggest that all calculated costs be rounded to either two or three significant figures. This will reflect the level of accuracy of the program. Computers calculate to too many decimals and give the impression of higher confidence that the input data warrants. Wherever possible it is recommended to use color images to make the report more interesting. Recommendations. I am comfortable with the power of the Utility Model to reasonably and easily calculate existing and proposed energy usage and costs for the home energy improvements listed above. I realize that the Utility Model is not a finalized and proven product. As such it will take some time to work out bugs even after the program is initially completed and put into use. The best way to improve the final product is to put it into early use. I suggest that your company use the output of the early versions of the Utility Report as preliminary for initial contacts. For contracts with customers, a careful consideration of construction costs and savings must be made even if different from the Utility Report s initial findings. Other Discussions. 7

The Utility Model does not need the count of the number or size of the windows. It uses a factor of 14.5 percent of the floor space to estimate the window area and is based on experience. This is reasonable for heat loss/gain purposes but may not be adequate for estimating the cost of replacing windows if single pane windows are involved. Your company may want to come up with a reasonable way of pricing window replacements. The Utility Model does not know the size of the actual ceiling of the house but has assumed it is the same as the area of the house. For a two story house the ceiling will be half the area of the house, etc. Thus the Utility Model may not reasonably calculate the correct area of the attic for calculating energy savings and construction costs. Idea Tree is aware of this problem and has agreed to fix the problem. Thank you for the opportunity to be of service to your company. If there are any questions or concerns regarding this report or related matters, please call at (610) 898-0252, or email at william.mcmahon.econ@earthlink.net. Respectfully submitted, William M. McMahon Jr. P.E. CEM President 8