Incinerators for hazardous materials Safety and reliability with newest technology

Similar documents
Transportable disease control units

Borregaard Case Study. Sarpsborg I & II

INDIVIDUAL CREMATOR. The most thermally efficient, robust and reliable cremation machines on the market. Simply Built Better!

Technology Specification

MP-300. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

GM2000. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better! GM2000. Touch Screen.

TB-AB AQUA. The most thermally efficient, robust and reliable marine incinerators on the market. Simply Built Better! TB-AB Aqua.

MultiZon incinerator for batch operation

MP-400. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

MP-500. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

H13 MULTI-MODE VORTEX PYROLYSIS REACTOR. Figure 1. Figure 1а LEGEND. I. RDF (refuse derived fuel),

1.01 Development of the Air cross flow gasification-process

Forester UFS Wood Chip Boiler

PORTFOLIO OF PRODUCTS AND SERVICES

International Experience: MSW Solutions for Urban Centres in India Waste-to-Energy Options

Green Incinerators Brand. Scan & Surf

R A S C H K A. Compact -Fluidized Bed Incinerator

The most thermally efficient, robust and reliable animal cremators on the market. Simply Built Better! Touch Screen. Refractory

SB-AB. The most thermally efficient, robust and reliable animal incinerators on the market. Simply Built Better! SB-AB. Touch Screen.

Log fired heating system

Gas Suspension Absorber

LB4000 Asphalt Concrete Mixing Plant

to a medium range machine. Our Mini Plus machine is capable of a burn rate of up to 50kg per hour cleanly We also manufacture high capacity burn rate

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Biomass Gasification

250Kg Animal Waste Low capacity Incinerator

BF-TYPE BOILERS FOR BIOMASS COMBUSTION

LFK Twin-Shaft Continuous Mixer. Intense mixing of dry and moist minerals

FILCON FILTRATION ApS THE FUTURE OF CLEAN AIR TECHNOLOGY

Incinerator Options. Surefire TS Fixed Hearth Incinerators. todaysurematthews.com +44 (0) Application. Throughput Capacities

High efficient multi-fuel CYMIC concept for biomass, rejects and coal for Hamburger Hungaria Katriina Jalkanen Valmet Technologies Oy

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

HDG Turbotec. HDG Log wood boilers. Comfortable and safe. 340-litre fuel chamber. Log wood sizes up to 1-metre long

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

Your partner for the right solution

Log fired heating system

Log fired heating system

FREQUENTLY ASKED QUESTIONS (FAQS)

Hamm MW Pyrolysis Plant. Integrated Pyrolysis into Power Plant Plant capacity 100,000 t/a Pre-processed Waste Materials

Experts in Furnaces. Engineering. Fast and flexible. THERMCONCEPT powerd by innovation

PRODUCT DESCRIPTION PARAMETERS

Date: March 10, Dear Sir/Madam,

HOW PYROLYSIS WASTE TO ENERGY WORKS

Group METERING SYSTEMS FOR SOLIDS

"Waste-to-Energy an essential part of the circular economy "

Compact Fluidized Bed Incinerator. slide 1

ADECOS II. Advanced Development of the Coal-Fired Oxyfuel Process with CO 2 Separation

Kazushige KUROSAWA*, Zhibao ZHANG**, and Zhengbing WANG** [Delivered Products & Systems] 1. Introduction. 2. Overview of Nanjing

plus pellet makes you independent

NTS N 113-MINSA / DGIEM-V.01, Technical Health Standard: Infrastructure and Equipment of Health Establishments of the First Level of Care.

Boilers & Fired Systems. Clean Coal Technology Dr. Tanveer Iqbal

Technical Description Package Micro Auto Gasification System (MAGS )

Waste Gasification and Melting Technology - Direct Melting System - Nobuhiro Tanigaki 22th November, AVG, Cologne

The types of industrial exhaust streams that present particular pollution-control challenges include:

PPC specializes in maximum efficiency air pollution control equipment using a variety of different

Soluzioni IT VERTICAL POWDER COATING LINES

COMBI BOILERS. The best choice for wood, pellets burning...

UltraGas. Technical Data Output range 15 to 2000 kw. Condensing Gas Boiler /02-07/15 Subject to modifications

INDUSTRIAL ACCESSORIES COMPANY

Industrial Gas Analyzers in Applications Information

Laboratory Chamber & Tube Furnaces. Testing Analysing Ashing Drying Preheating Debinding Firing Sintering Annealing Melting

COMBI BOILERS. The best choice for wood, pellets burning...

Report on Delivery and Operational Condition of Largescale Grate-type (Stoker-type) Incinerator in Nanchang City, Jiangxi, China

Technical Session on Healthcare Waste Management - Treatment of infectious and sharp waste -

Conveyor System Technology. krones AirCo. Air Conveyor

Product catalogue. Compliant with EN norm

Forward-looking and energy efficient Biomass heating

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

CIFAMIX THE MODULAR MIXING PLANT CIFAMIX PLANTS

WASTE TYRE RECYCLING PLANT

Hazardous Waste Treatment Technology

Wood gasification and combined biomass boiler

Acerra WtE plant plant block diagram MSW receiving section Combustion and flue gas cleaning

FUEL FLEXIBILITY, EFFICIENCIES AND PAY-BACK OF ADVANCED ENERGY PLANTS!!

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

A new technology for high efficient Waste-to-Energy plants

Koji KOBAYASHI*, Zhengbing WANG**, Wengang ZHANG**, and Zhenpeng SUN** [Delivered Products & Systems] 1. Introduction

BIOMASS ENERGY INSTALLATIONS SUSTAINABLE AND EFFICIENT ENERGY FROM BIOMASS.

MIXING EQUIPMENTS AND SERVICES FOR PVC DRY-BLEND, POWDER COATINGS, MASTER BATCH AND WPC

S THERMAL OXIDIZER SOLUTIONS TO MEET TOMORROW S CHALLENGES

GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR

NATIONAL CERTIFICATION EXAMINATION 2004 FOR ENERGY MANAGERS

Environmentally Sound Technology Biomass Fuelled Energy Plants. Combined Heat and Power Supply. Biomass Fired Steam Generator

Services to Technology Providers

Recycling of sewage sludges: pyrolysis.

Application of CFB (Circulating Fluidized Bed) to Sewage Sludge Incinerator

Pre-treatment plant. Plant BIOROT 200 CC. General description

T U R B O B L O W E R S

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

Hoval CF Biomass Filter Outputs from 50 to 1200kW

CeraTHERM stack. Clean room-compatible thermal systems with stacking technology. Thermal systems

Development of EAF Dust Recycling and Melting Technology Using the Coal-based FASTMELT Process

WASTE TO ENERGY SOLUTIONS

CONTROLLED PYROLYSIS CLEANING OVENS

INDIRECT THERMAL DESORPTION PLANT

Blockages in Cement Storage Silos

Callidus Oxidizer Systems. Thermal and Catalytic Oxidizer Systems

AN INDIRECT-FIRED ROTARY SUGARCANE BAGASSE TORREFYER: DESIGN AND PERFORMANCE

Transcription:

TRANSPORTABLE / MOBILE INCINERATOR UNITS TIU-8G+ 2017 made in Germany Retrofittable modular system TIU-8G+: 0 250 kg/hr 850/1100 C Incinerators for hazardous materials Safety and reliability with newest technology PATENTED TECHNOLOGY

TRANSPORTABLE / MOBILE INCINERATOR UNITS TIU-8G+ 2017 In the field of combustion technology, we have an extensive know-how, experience and references. We guarantee our customers high availability of custom made equipment. Incineration of hazardous materials Incineration is an important procedure for waste treatment. The critical waste will be burnt in a sterile incineration process and the amount of waste will be reduced that must go to waste landfills. Especially in the field of clinical waste the transportable incinerators are an active instrument of and for disease control. Basically there are no alternatives to modern incineration, because since 1 June 2005, the landfilling of untreated waste will be banned in Germany (acc. to TA Municipality Waste), in the European Union (EU) and in many other countries worldwide. Waste may only go to a waste landfill as slag after its combustion. This reduces the need of landfill space, which is scarce and expensive, since the combustion residues need essentially less space. Furthermore, during biodegradation processes of the untreated waste in the landfilling site, pollutants will be produced that burden the groundwater, the soil and the surrounding air of the landfill site. Today, slag and combustion residues of a modern incinerator have a rest part of less than 3% carbon and usually they reduce the volume of garbage by 90 95%. Also, the allowable percentage of biodegradable components in landfills has been limited to 3% maximum by the EU Directive 1999/31/EC, to protect the environment. Therefore, incineration of waste is in the EU Member States and many other countries worldwide a necessity to protect the environment. Our transportable solution The TIU-8G solution can be put anywhere into operation and has an excellent combustion capacity. Capacity up to 250 kg/hr with a very big volume of the incineration chambers. PLANT CONCEPT The whole plant is mounted on two 40 feet flat racks and consists of four segments: - 2 stage incineration module with cooling module - Filter module with supply module The plant concept based on durability to reduce maintenance efforts under site conditions which can be difficult for the operators at site. Two modules combine a fully equiped and environmentally friendly stand-alone unit! It has all necessary auxiliaries on board, like diesel pump and a compressor system. The incinerator can be delivered ally with a lance spray system for liquids, a power generator and a continuous exhaust gas monitoring system (CEGM). It is equiped with a two-stage filling system consisting of a concrete gate valve with feeding hopper for top loading. The refractory lining is based among others on extremely heat-resistant fiber and a wear-resistant fire concrete. The easy installation and operability improve the transportable usage under field conditions. -2-

Modules of a plant Sample of a military incineration unit: 2 stage incineration module with front feeding system for batches and concrete gate valve on top with feeding hopper connection. Exhaust outlet incinerator Chimney and supply module THE FIRST MODULE INCLUDING INCINERATION UNIT Standard execution transportable 2 stage incineration unit: Model: Waste Capacity: Calorific value: Density: Burner s Thermal Capacity: Calorific value of waste: Main combustion chamber: Post combustion chamber: Kind of plant: Burners: Waste filling: De-ashing: Type of Waste / Suitable for: Forbidden materials: Requirements: Options: TIU-8G+ 2017 0 250 kg/hr 1 45 MJ/kg 50 1.250 kg/m3 2 x 700 kw 12500 kj/kg Temperature up to 850 C Temperature up to 1100 C Fix bed system with movable grate Diesel burner system with fuel pump Top filling system with conveyor connection 3 side doors for manual de-ashing Domestic waste and hazardous waste like industrial waste, medical waste, chemical residues that are solid and paste-like up to 30% moisture content. Ammunition and other explosives, lightning ammunition, Akkus and Batteries, mercury containing materials, PVC (only smaller amounts per feeding sequence allowed) Fuel (Diesel), Power (power generator as available). Lance spray system for liquids Conveyor Front feeding system with pneumatic actuator (one or two cylinder) INCLUDING ENVIRONMENTAL FRIENDLY COOLING UNIT A heat exchanger is a modular part of the whole incineration system. It will cool the flue gas down to a temperature of averagely 230 C. The advantage is that this facility do not require water consumption. In contrast to a spray cooling system this facility saves approx. 1-4 tons of water per hour. Key figures: - Air cooler. - Pipes made of carbon and stainless steel. - Cooling air fan and blow-off pipe for cooling air. - No water consumption. - External insulation. -3-

THE INCINERATION PROCESS The basic modules are made for the THERMAL DESTRUCTION that combines high temperature, long residence time and high turbulence together with an adequate fuel management system to ensure that hazardous materials are efficiently destroyed. Hazardous materials, when heated to a very high temperature undergoes predictable physical and chemical changes. The high temperature, that is over 1000 C prevents the formation of complex organic molecules and breaks down organics into gas. These primary molecules are stable at that temperature. The oven of our system is capable of burning the waste at a temperature of 850-1100 C. The more toxic the material, the higher the burning temperature needs to be. An incineration unit will be extended with two additional modules: a) an air cooling system on the same flat rack and b) a filter system for dust filtering and chemical neutralization due to an adsorption system, that combine the following advantages: CHEMICAL NEUTRALIZATION has been done by use of a special additive that must be added to the waste. This is a very effective additive for SO2, HCl and HF, heavy metals, dioxins, etc. PHYSICAL FILTERING will be applied by means of a special filter system. The particle removal creates a filter cake, which supports the removal efficiency. Depending on the differential pressure measured across the filter, the parts of the filter elements are cleaned by means of pressurized air impulses. ADSORPTION is a part of the chemical neutralization, e.g. the binding of molecules or particles to a surface will be done by means of feeding the flue gas through an activated carbon mixture (additives NaHCO3). In this stage, the flue gas components with color or those that have taste or odor will be bound, so all these may-be-non-toxicbut disturbing gas components will be eliminated and a colorless, odorless flue gas will be emitted to the atmosphere. As a result above destruction/separation systems in combination care for a very environmental friendly Incineration. CHARGING TWO-STAGE TOP FILLING SYSTEM This system consist of a state of the art double gate semi-automatic door that do not allow leakage from inside of the fire room to the outside. This door system is consisting of two gates: upper gate is a flap system opened and closed pneumatically. The lower gate is a horizontally sliding gate that is also actuated pneumatically. This gate moves into a closed room. If the feeding is done, the waste falling on to the lower gate. If the upper flap closes the lower gate will be slided horizontally and the waste fall down to the fire room. The lower gate is cladded with fire resistant special concrete like inside the main combustion chamber. The feeding is controlled by the operator. Picture: Sample of a two-stage filling system. INCINERATION PROCESS AND BURNER CONTROL An automated burner serves for the heating of the combustion chamber subject to the temperature of the fire room. For heating the unit at start up the burner is in operation. The feed opening should remain closed, as long as the necessary flue gas temperature is not reached. In the post combustion chamber the gas is heated up to a minimum of 1100 C. The incineration process produces a sterile ash quality. If the incinerator is used as a stand alone unit, the stack module will be mounted to it and the flue gas will be released mixed with fresh air for cooling down the hot flue gas before discharging to the atmosphere from the stack. -4-

INSULATION / LINING The main combustion chamber is lined with a special ceramic fiber, which is surrounded by a concrete sheath. It is specially blended and very wear- and impact-resistant. The bottom of the post combustion chamber (gas combustion) is lined with a special ceramic fiber, which is surrounded by a concrete sheath. The walls are insulated with a special ceramic fibre, which is heat-resistant up to 1200 C. This fiber has a special coating as sealing surface that makes it insensitive to dust so that a wear protection is given. Maintenance and repair work are easy to perform. THE SECOND MODULE ADDITIVE DOSING SYSTEM On top of the cooling system near to the discharge side there is the special opening to feed an additive (see plant configuration table, next page). Via this opening an additive can be loaded manually, if needed. The additive dosing system can be supplied in two types: Standard version for manual filling or ally as an automated filling system. The additive (NaHCO3) is needed if chemical substances like PVC, plastics, etc. shall be incinerated because that can cause emissions of dioxins and furans or heavy metals. The activated carbon added to the additive ensures that the flue gas will not have any color and odour. TEMPERATURE RESISTANT FILTER UNIT This filter system is a modular part of the whole incineration system. It is connected to the outlet of the air-cooling unit and filter the flue gas of the incineration process. Key figures: - Filter with fabric or ceramic filter candles. - Maximum temperature resistance 350 C. - Dust discharge with a screw conveyor system. - Induced draft fan. - External insulation. The filter system ensures cleaning of the flue gas from fly ash and all emissions, color and odor by means of the additive that is added from top of the cooling module above. CONTROL SYSTEM The unit will be furnished with a simple control system that enables easy and safe controlling the system, acc. to the German Electrical Norms and VDI. Standards STACK AND ACCESSORIES - Design DIN/EN, - Control equipment VDE, - Documentation DIN EN 746 Standard execution: - Stack (Can be delivered as an arch construction that can be directly mounted to the chimney connection. That is a great help for installation and operating at different sites.) - Compressor - Fans Optionally: - Generator - Continuous exhaust gas monitoring system (CEGM) - Diesel and water tanks -5-

OPTIONAL CONTINUOUS EXHAUST GAS MONITORING (CEGM) SYSTEM The CEGM system will be installed in second module. A continuous exhaust gas monitoring system is usable for automated hover bed combustion plants and fix bed plants with movable grate. Envisaged analyses could be: HCL, CL2, NOX, SOX, CO and TOC. The operation frequency can be either continuous operation or activation at a predefined frequency or upon demand. OPTIONAL DIESEL TANK As diesel tank we can offer a wide range of sizes. Most frequently asked size is united in the PE combined 1000 VS The volume of this system is 1000 l that could be bigger on demand. We prefer a supply including: - 10m fuel hose with fuel lance and foot valve - Optical level indicator - Content indicator and - Vent hood. Tanks will be normally installed in second module. FEATURES OF OUR TRANSPORTABLE SYSTEM - Patented transportable solution. - Excellent combustion capacity. - Very big volume of the incineration chambers. - Capacity up to 12 t per day. - Easy commissioning. - Easy maintenance. - Low energy consumption. - Low operation cost. - High performance. -State of the Art. - Highest technology s. -Made in Germany. Please note: Transportable / Mobile Incinerator Units are special designs. Technical alterations reserved! -6-

PLANT CONFIGURATION TIU 8G+ 2017 INCINERATION UNIT Capacity 0 250 kg/hr Burning temperature () 850 / 1100 C Max. Burning temperature () 950 / 1300 C Diesel burner system NG burner system Manual feeding Conveyor for waste feeding Manual slag extraction Incinerator with environmentally friendly movable grate. Sufficient ventilation and physical breaking of the waste for a clean and effective combustion. Liquid waste lance spray system Type of Waste / Suitable for Domestic waste and hazardous waste like industrial waste, medical waste, chemical residues that are solid and paste-like up to 30% moisture content. Ammunition and other explosives, lightning ammunition, Akkus and Batteries, mercury containing materials, PVC (only smaller amounts per feeding sequence allowed) forbidden FLUE GAS COOLING UNIT Environmental friendly Air Cooling System - Air cooler. - Pipes made of carbon and stainless steel. - Cooling air fan and blow-off pipe for cooling air. - No water consumption. - External insulation. FLUE GAS CLEANING UNIT Temperature resistant flue gas cleaning system - Filter with fabric filters or ceramic filter candles. - Dust discharge system. - Induced draft fan. - Insulation. Additive dosing system, manual Additive dosing system, automatic CHIMNEY AND ACCESSORIES Compressor Fan (3-Ph/400V) Chimney with a height from ground +6 m Generator (3-Ph/400V) Control box Continuous Exhaust Gas Monitoring System CEGM (Continuous Exhaust Gas Monitoring) SystemEnvisaged analyses could be Chlorides (Hcl, Cl2), NOx, SO2 as Sox, Carbons as TOC, CO and TSP (total suspended particles) etc. Diesel tank PE combined 1000 VS Volume 1000 l Whatever else -7-

CONTACT ZANNI + PARTNER Ltd. Rheinpromenade 9 40789 Monheim Germany Phone: +49 2173 2608272 Fax: +49 2173 2608275 email: mail@zanni.de web: http://www.zanni.de LOCAL AGENT (C) Zanni + Partner Ltd. - Transportable Incinerator Units TIU-8G+ 2017 20170927