UFB. Floor Products. Floor outlet boxes. Content. UFB-700 and UFB-900, rectangular and square fl oor outlet boxes for dry premises Page 2

Similar documents
OptiLine 70. Service Poles. Technical and Material data

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Installation Boxes. Multifix Air. Setting a new standard in energy efficiency

Perfect integration! >>> FLOOR BOXES. NEW floor boxes

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

ENERGY-DISTRIBUTION. TwinLine N 44 The new system of floor-standing cabinets in IP44

BOXES - CONSUMER UNITS

Fire Protection Valves

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

New consumer units. Design and functionality in plain sight.

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

TECHNICAL MANUAL. PC Beam Shoe. Hidden Beam Shoe for Corbel System

NETbox Wall Mounting CABINETs

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

392 Montecarlo with bracket

Installation materials Flexible and easy-to-install products

THE FLEXIBILE, ROBUST SOLUTION AND EFFECTIVE IP 66 WEATHERPROOF FLOOR BOXES 4 MODULES

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0238

NETbox Wall Mounting CABINETs

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

MHST 20 lifting/sliding door threshold

Phone: +49 (0) 231 / Fax: +49 (0) 231 / Spring hinges. Art.: 6164 Art.

NATIONAL GRID SEMI-BURIED GAS METER BOX Model KG60046

Series ESK / ESB. Cabinets in Modular Design. Manufacturing Program: ESK-20 ESK-40 ESK-80 ESB Sandwich construction 20 mm, 40 mm and 80 mm

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

Concrete Screw-Anchors

SECTION ALUMINUM HANDRAIL SYSTEMS

Cable Management System. Technical Data Sheet document

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Planning and installation instructions

Sliding Door Systems

Cable junction boxes with intrinsic fire resistance and insulation integrity

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

Aquareva. Main drains. Technical data: Table of contents. Masonry / Liner. Concrete. Polyester shell Positioning Aquareva Color.

Flush Service Floor Boxes

Galvanized Steel Bead Accessories for Stucco and Plaster Installations ALABAMA METAL INDUSTRIES CORPORATION. Contract Number:

LEADING IN WELDING SAFETY CATALOGUE 2014 CONSTRUCTION. Version 14/01

min. 50min. 65min. PIT / P3 / P4 Ø

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Termco Heatshrink.

18 Thorsman Installation Material

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

TI-LINE TILUX DURABASE. Borderless Shower Areas

LK Manifold Cabinet UNI, LK Prefab Cabinet UNI

Project drains. Project drains. Floor/Bathroom drains. Shower channels. Basement drains. Drains and channels in stainless steel. Exterior installation

Unitised Curtain Wall Beaded

ALUBOX Series Junction boxes in IP66 aluminium alloy

STANDARD SHELTER SPECIFICATIONS ATTACHMENT A

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

50 N E T b o x Wall Mounting C A B I N E T s

Panel elements. Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements

SECTION HANGERS AND SUPPORTS FOR PLUMBING

תעלות Channels. Special channels. Channels. Uses 1. Drainage channels. 2. Channels for electricity and control cables. 3. Channels for pipes.

PRODUCT GUIDE. Connectivity with flexibility.

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

TRITEC light Steel Panel Formwork

Student Services & Classroom Addition

UDHOME Floor socket and floor box British Standard

ACO Civil Engineering

Standard program overview fire doors

2500 Series Fire Smoke Dampers

Original Scandinavian rainwater system

Curtain Wall Stick System (Capped)

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

Underground Dry Utilities Civil Engineering 2014 Edition

PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Zinc Alloy Bead Accessories for Stucco and Plaster Installations ALABAMA METAL INDUSTRIES CORPORATION

Adjustable Suspension Hanger Technical Datasheet

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

Delta Part Liber Superthermic Insulated Bi-Folding Door. Product Data Sheet 7 / 4

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Protective devices according to EN ISO 12100

Section 5 Panels & Accessories

Underground Exhaust System

Smarter. Safer. Leaner.

IP68 Quick connection system. IP68 Quick connection system

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

Mounted Enclosures Steel Powder-Coated

LAYHER EVENT SYSTEMS CATALOGUE

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

TFX - Toggle Lock Installation Guide

Safety Ladders: Made of Aluminium

PRODUCT APPLICATION MANUFACTURER INTRODUCTION CERTIFICATION PROCEDURE. Date of update April 6, 2018 Valid until

Flush mounting boxes. For masonry - TECHNICAL CHARACTERISTICS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Transcription:

P1989 Content -700 and -900, rectangular and square fl oor outlet boxes for dry premises Page 2-140M, square fl oor outlet box intended for dry premises Page 5-700M and -900M, rectangular and square fl oor outlet boxes mainly intended for dry premises (if provided with a centre-positioned cable exit and completed by a special sealing, also to be used in wet-cleaned applications) Page 6-800, round fl oor outlet box for dry premises Page 10 -IG, screeded fl oor boxes Page 13 1 (16)

P71458 P71464-700 & -900 Description -700 and -900 are fl oor outlet boxes for dry premises with an incavity fl oor or a raised access fl oor. For casting in concrete, the fl oor outlet boxes should be used in conjunction with screeded fl oor box -IG or former -RF. The rectangular -700 is 220x310 mm and the square -900 is 310x310 mm. The dimension of the hole in the fl oor is 201x292 ±1 mm for -700 and 292x292 ±1 mm for -900. The required smallest installation depth for the fl oor outlet boxes is 110 mm and the greatest internal depth 54 mm. The boxes are based on a grid for the outlets and connections, completed by a trim frame with a lid. Grid The grid has three F80 openings for CAN and/or CYB outlets for power, telecom and data. Grid infi ll -L is to be used to cover space that is not taken up by an outlet. Trim frame and lid The lid that can be trimmed with any material of up to 8 mm thickness. Note, however, that hard, brittle materials like stone should be avoided, since there is a risk that they might crack. The trim frame is provided with a fl ange that bears upon the fl ooring to conceal the edge of the hole and to outbalance the loads exerted on the box. In the 80 opening position the lid is self-closing. When required, the lid can be kept open or completely removed by pressing down the red buttons at the hinges. The lid is reinforced by of 4 mm thick sheet steel inlay. The strength has been tested according to DIN VDE 0634 Part 1 and it fulfi ls requirements according to PSA Specifi cation MOB PF2 Jan. 1992. Description of the strength tests and test results are available on request. Degree of protection Complies with IP20 in accordance with IEC 529. Cable capacity 2x600 mm 2 max. cable Ø 14 mm. Standards DIN VDE 0634 Teil 1 PSA Specifi cation MOB PF2 PS, Jan 1990 Approvals VDE. Material data Extruded aluminium Specifi cation: AlMg 0.5 Si (AA 6063) Density: 2.6 g/cm 3 Linear expansion: 2.4x10 6 m/m C Sheet steel Specifi cation: S 235 JR Surface treatment: Galvanized Z275 Steel (lid plate) Specifi cation: S 350 GD Material thickness: 4 mm Surface treatment: Galvanized Z 275 Spring steel (lid lifting handle) Specifi cation: DIN 17223 Surface treatment: Electroplated Fe/Zn 5 c1 2 (16)

Exploded view -700 & -900 2 1 3 7 1. Grid 2. Trim frame 3. Lid 4. Cable holder Design and dimensions -900-700 5. Floor fi xing 6. Lid lifting eye 7. Earth wire 5 6 4 Material data, cont. PC/ABS Density 1.14 g/cm 3 Linear expansion 70x10 6 / C Volume resistivity >10 13 Ω cm Water absorption 0.6% Dielectric strength 19 kv/mm Fire rating UL 94 HB (halogen-free) Colour White RAL 9016 PA6 Density: 1.13 g/cm 3 Linear expansion: 100x10 6 m/m C Water absorption: 2.8% Volume resistivity: >10 15 Ω cm Dielectric strength: 60 kv/cm UL 94 V-2 (halogen-free) Colours: Grey RAL 7011 ( NCS 6905-B05G) Red PA6.6 with 30% glass-fi bre Density: 1.35 g/cm 3 Linear expansion: 40x10 6 m/m C Water absorption: 1.7% Volume resistivity: >10 12 Ω cm Dielectric strength: 70 kv/mm UL 94 HB (0.79 mm halogen-free) Colours: Grey RAL 7011 ( NCS 6905-B05G) EPS S15 (foamed polystyrene) Density: 0.015 g/cm 3 White Firefl ex (foam cushion) Specifi cation: S305+4610 B1 Grey Operative data Compatible with Not compatible with Floors approved for dry premises. Raised access fl oors (RAF), in-cavity fl oors, screeded fl oors in conjunction with -IG or -RF. Boxes CYB, CAN and MIB. Outlet systems CYB and CAN and standard outlets. Floors approved to withstand water. Floors with a smaller construction height than 110 mm. Standard outlets with larger covering plates than 84 mm. Mounting instruction Mounting instruction is enclosed with the product. It is also available on Pl@net. Art. No. 20060400-700 & -900 Product Environmental Facts Product Environmental Fact fi les are available on Pl@net. Package info Package information is included in the Prodat fi le, which is available in the SAP system. Package information can also be obtained from the responsible factory. -700/900 3 (16)

-700 & -900 P106171 Type Colour Dimensions A/B/C (mm) Floor outlet box Qty per package EAN code Internal ID-No. Ref. No. Complete fl oor outlet box including grid, trim frame and lid, with the grid mounted onto the trim frame. Suitable for raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 110 mm; in the latter case in combination with screeded fl oor box -IG or former -RF. Grid infills -L165 or -L252 to be used to fi ll empty openings in the grid. Material: PA6, sheet steel, extruded aluminium. -700 Grey 73/220/310 1 7332418020336 20059896 5197 005 RAL 7011 P106170-900 Grey RAL 7011 73/310/310 1 7332418020343 20059897 5197 055 P111239 P67885 Grid infill Grid infi ll intended to cover space that is not taken up by an outlet. Material: PC/ABS, white RAL 9016. -L165 White 13/80/165 10 7315885197411 10002124 5197 410 -L252 White 13/80/252 10 7315885197442 10002127 5197 440 Locking kit Locking kit for the lid, to be used as an extra protection against unauthorized access; opened by means of a screw-driver. Material: PA6.6 with 30% glass-fi bre.. -LL Grey 27/36/35 1 7315885197251 10002107 5197 250 P111055 P67886 Cable outlet Cable outlet kit, to be used if a cable outlet of -700 or -900 has to be exchanged. Material: PA6. -CO Grey 32/78/35 1 7315885150775 20033877 5150 770 RAL 7011 Former Former to be used when making cavities in in-cavity fl oors, or as an alternative to a screeded fl oor box in screeded fl oors. To be placed on the fl oor slab before the concrete is poured. As soon as the concrete has hardened, the former can be removed. Material: EPS (foamed). -RF White 115/250/340 5 7315885197916 10002149 5197 910 For -700 -RF White 115/340/340 5 7315885197923 10002151 5197 920 For -900 4 (16)

P100123 Floor outlet box -140M Description -140M is a floor outlet box made of stainless steel intended for incavity floors or raised access floors in dry premises. For casting in concrete, the boxes should be used in conjunction with screeded floor box -IG140. Trim frame and lid The trim frame has an integrated 110 mm opening for outlets and two knock-outs for LexCom RJ45 connections and is provided with a flange that bears upon the flooring to conceal the edge of the hole and to outbalance the loads exerted on the box. The lid has a thickness of 2 mm and has a slot for cable exit. The trim frame is supplied with a plate (item 4 in the exploded view) that covers the cable exit slot in the lid. When turned 180 it provides an open cable exit. P100121 P100120 Dimensions External Dim. of hole Smallest inst. dim., mm in floor, mm depth, mm Exploded view 3 4 1. Trim frame with integrated grid 2. Lid with cable exit slot 3. Floor fi xing 4. Covering plate for cable exit slot (turn 180 to open the cable exit) Design and dimensions 2 1-140M 160x160 136x136 ±1 90 The greatest internal depth is 43 mm. Degree of protection Complies with IP20 in accordance with IEC 529. Cable capacity -140M Cable exit in side position: one 20x40 mm (800 mm 2 ) Standards DIN VDE 0634 Teil 1 PSA Specifi cation MOB PF2 PS, Jan 1990 Material data Stainless steel Specifi cation: X5CrNi 18-10 Operative data Compatible with Not compatible with Raised access fl oors (RAF) and in-cavity fl oors Screeded fl oors in conjunction with -IG140 Floors approved for dry premises Boxes CYB and CAN. Outlet systems CYB and CAN and standard outlets. Floors with a smaller construction height than 90 mm Standard outlets with larger covering plates than 84 mm. Mounting instructions Mounting instructions are enclosed with the product. They are also available on Pl@net. Art.No. 0075237/MI 2330-140M Product Environmental Facts Product Environmental Fact fi les are available on Pl@net. Package info Package information is included in the Prodat fi le, which is available in the SAP system. Package information can also be obtained from the responsible factory. -140M P67884 Type Colour Dimensions A/B/C (mm) Floor outlet box Qty per package EAN code Internal ID-No. Ref. No. Floor outlet box including grid, trim frame and lid. The lid is provided with a slot for cable exit. With integrated front F80, length 110 mm, and two 17.5x18.5 mm cut-outs for RJ45 LexCom covered by a blind plug. Suitable for raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 90 mm, in the latter case in combination with screeded fl oor box -IG140. Material: Stainless steel X5 CrNi 18-10. -140M 63/160/160 1 7315885198043 20043874 5198 040 5 (16)

P64074 P64072 P64232 Design and dimensions -700M A = 89 mm or 99 mm depending on lid thickness P64078 P64079-900M -700M, & -900M Description -700M and 900M are fl oor outlet boxes made of stainless steel, intended for in-cavity fl oors or raised access fl oors. The boxes are mainly intended for dry premises, but if provided with a centre-positioned cable exit and completed by a special sealing, they can also be used in wetcleaned applications. For casting in concrete, the boxes should be used in conjunction with screeded fl oor box -IG. Trim frame and lid The trim frame is provided with a fl ange that bears upon the fl ooring to conceal the edge of the hole and to outbalance the loads exerted on the box. The lid is available in two thicknesses, 15 mm and 25 mm, and with a cable exit position either in the centre or on the side. The centre cable exit can be completed by a cable exit unit with or without spacer tube. Grid The grid has three F80 openings for CAN and/or CYB outlets for power, telecom and data. Grid infi ll -L is to be used to cover space that is not taken up by an outlet. Dimensions External Dim. of hole Smallest inst. dim., mm in floor, mm depth, mm -700M, lid 15 231x322 201x292 ±1 115-700M, lid 25 231x322 201x292 ±1 125-900M, lid 15 322x322 292x292 ±1 115-900M, lid 25 322x322 292x292 ±1 125 The greatest internal depth is 52 mm. Degree of protection Complies with IP20 in accordance with IEC 529. Cable capacity -700M/900M Cable exit in side position: one 14x97 mm (1358 mm 2 ) Cable exit in centre position with spacer tube: two 12x40 mm (2x480 mm 2 ) without spacer tube: one Ø67 mm Standards DIN VDE 0634 Teil 1 PSA Specifi cation MOB PF2 PS, Jan 1990 Material data Extruded aluminium Specifi cation: AlMg 0.5 Si (AA 6063) Density: 2.6 g/cm 3 Linear expansion: 2.4x10 6 m/m C Aluminium Specifi cation: AlMg 0.5 Si (AA 6063) Density: 2.6 g/cm3 Linear expansion: 2.4x10 6 m/m C Surface treatment: Anodizing Sheet steel Specifi cation: S 235 JR Surface treatment: Galvanized Z275 Stainless steel Specifi cation: X5CrNi 18-10 PC/ABS Density: 1.14 g/cm 3 Linear expansion: 70x10 6 / C Volume resistivity: >10 13 Ω cm Water absorption: 0.6% Dielectric strength: 19 kv/mm UL 94 HB (halogen-free) White RAL 9016 Foam rubber Black 6 (16)

Exploded view 2 1 3 1. Grid 2. Trim frame 3. Lid 4. Cable exit (side position, also available in centre position) 4 Operative data Compatible with Not compatible with Raised access fl oors (RAF) and in-cavity fl oors Screeded fl oors in conjunction with -IG Floors approved for dry premises (NOTE! Boxes provided with a sealing and with cable exit in centre position can be used in fl oors approved for wet cleaning) Boxes CYB, CAN and MIB. Outlet systems CYB and CAN and standard outlets. Floors with a smaller construction height than 115 mm for -700M/900M with 15 mm lid 125 mm for -700M/900M with 25 mm lid Standard outlets with larger covering plates than 84 mm. Mounting instructions Mounting instructions are enclosed with the product. They are also available on Pl@net. Art.No. 20060417-700M/900M with centre exit Art.No. 20060418-700M/900M with centre exit and screw-fi tted cover Art.No. 20060416-700M/900M with side exit Product Environmental Facts Product Environmental Fact fi les are available on Pl@net. Package info Package information is included in the Prodat fi le, which is available in the SAP system. Package information can also be obtained from the responsible factory. 7 (16)

-700M P67886 P111239 P67883 P67881 P67882 P106173 P106172 Type Colour Dimensions A/B/C (mm) Floor outlet box for dry applications Qty per package EAN code Internal ID-No. Ref. No. Complete fl oor outlet box including grid, trim frame and lid, supplied with earth cable, fl oor fi xings and fi xing screws. The lid is provided with a cable exit in side position and can be trimmed with optional fl oor material up to 15 or 25 mm thickness respectively. Suitable for dry applications in raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 115 or 125 mm respectively; in screeded fl oors in combination with screeded fl oor box -IG and installation cover -MP for -700. Material: Stainless steel X5 CrNi 18-10. -700M 89/231/322 1 7332418020206 20059892 5198 715 15 mm lid with side exit -700M 25 mm lid with side exit 99/231/322 1 7332418020220 20059894 5198 725 Floor outlet box for wet-cleaned floors Complete fl oor outlet box including grid, trim frame and lid, supplied with earth cable, fl oor fi xings and fi xing screws. The lid is provided with a cable exit in centre position, suitable for cable exit unit with or without spacer tube, and can be trimmed with optional fl oor material up to 15 or 25 mm thickness respectively. Suitable for wet-cleaned raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 115 or 125 mm respectively; in screeded fl oors in combination with screeded fl oor box -IG and and installation cover -MP for -700. Material: Stainless steel X5 CrNi 18-10. -700M 89/231/322 1 7332418020282 20060384 5198 716 15 mm lid with centre exit -700M 89/231/322 1 7332418020213 20059893 5198 717 15 mm screw-fi xed lid with centre exit -700M 99/231/322 1 7332418020299 20060385 5198 726 25 mm lid with centre exit -700M 99/231/322 1 7332418020237 20059895 5198 727 25 mm screw-fi xed lid with centre exit Cable exit unit without spacer tube Cable exit unit without spacer tube, for -700M and 900M with a centre-positioned cable exit. The cover of the unit is provided with two cavities, suitable for a special opening tool. The tool is supplied with the product. Material: Aluminium AlMg 0.5 Si (AA 6063). -CE Anodized 15/Ø96 1 7315885198104 20043867 5198 100 For 15 mm lid -CE Anodized 25/Ø96 1 7315880108580 20043868 5198 102 For 25 mm lid Cable exit unit with spacer tube Cable exit unit including spacer tube, for -700M and 900M with centre-positioned cable exit. The cover of the unit is provided with two cavities, suitable for a special opening tool. The tool is supplied with the product. Material: Aluminium AlMg 0.5 Si (AA 6063). -CEW Anodized 67/Ø96 1 7315880108597 20043869 5198 104 For 15 mm lid -CEW Anodized 67/Ø96 1 7315880108603 20043870 5198 106 For 25 mm lid Sealing Sealing to be inserted in the trim frame for wet-cleaned fl oor applications. NOTE! Can only be used in conjunction with centrepositioned cable exit. Suitable for -700M. Material: Foam rubber. -S700 Black 6/196/287 1 7315885198135 20043853 5198 130 Grid infill Grid infi ll intended to cover space that is not taken up by an outlet. Material: PC/ABS, white RAL 9016. -L165 White 13/80/165 10 7315885197411 10002124 5197 410 Former Former to be used when making cavities in in-cavity fl oors, or as an alternative to a screeded fl oor box in screeded fl oors. To be placed on the fl oor slab before the concrete is poured. As soon as the concrete has hardened, the former can be removed. Material: EPS (foamed). -RF White 115/250/340 5 7315885197916 10002149 5197 910 For -700 8 (16)

-900M P67886 P111239 P67883 P67881 P67882 P106175 P106174 Type Colour Dimensions A/B/C (mm) Floor outlet box for dry applications Qty per package EAN code Internal ID-No. Ref. No. Floor outlet box including grid, trim frame and lid, supplied with earth cable, fl oor fi xings and fi xing screws. The lid is provided with a cable exit in side position and can be trimmed with optional fl oor material up to 15 or 25 mm thickness respectively. Suitable for dry applications in raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 115 or 125 mm respectively; in screeded fl oors in combination with screeded fl oor box -IG and and installation cover -MP for -900. Material: Stainless steel X5 CrNi 18-10. -900M 89/322/322 1 7332418020244 20059898 5198 915 15 mm lid with side exit -900M 25 mm lid with side exit 99/322/322 1 7332418020268 20059900 5198 925 Floor outlet box for wet-cleaned floors Floor outlet box including grid, trim frame and lid, supplied with earth cable, fl oor fi xings and fi xing screws. The lid is provided with a cable exit in centre position, suitable for cable exit unit with or without spacer tube, and can be trimmed with optional fl oor material up to 15 or 25 mm thickness respectively. Suitable for wet-cleaned raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 115 or 125 mm respectively; in screeded fl oors in combination with screeded fl oor box -IG and installation cover -MP for -900. Material: Stainless steel X5 CrNi 18-10. -900M 89/322/322 1 7332418020305 20060386 5198 916 15 mm lid with centre exit -900M 89/322/322 1 7332418020251 20059899 5198 917 15 mm screw-fi xed lid with centre exit -900M 99/322/322 1 7332418020312 20060387 5198 926 25 mm lid with centre exit -900M 99/322/322 1 7332418020275 20059901 5198 927 25 mm screw-fi xed lid with centre exit Cable exit unit without spacer tube Cable exit unit without spacer tube, for -700M and 900M with a centre-positioned cable exit. The cover of the unit is provided with two cavities, suitable for a special opening tool. The tool is supplied with the product. Material: Aluminium AlMg 0.5 Si (AA 6063). -CE Anodized 15/Ø96 1 7315885198104 20043867 5198 100 For 15 mm lid -CE Anodized 25/Ø96 1 7315880108580 20043868 5198 102 For 25 mm lid Cable exit unit with spacer tube Cable exit unit including spacer tube, for -700M and 900M with centre-positioned cable exit. The cover of the unit is provided with two cavities, suitable for a special opening tool. The tool is supplied with the product. Material: Aluminium AlMg 0.5 Si (AA 6063). -CEW Anodized 67/Ø96 1 7315880108597 20043869 5198 104 For 15 mm lid -CEW Anodized 67/Ø96 1 7315880108603 20043870 5198 106 For 25 mm lid Sealing Sealing to be inserted in the trim frame for wet-cleaned fl oor applications. NOTE! Can only be used in conjunction with centrepositioned cable exit. Suitable for -900M. Material: Foam rubber. -S900 Black 6/287/287 1 7315880108481 20043854 5198 135 Grid infill Grid infi ll intended to cover space that is not taken up by an outlet. Material: PC/ABS, white RAL 9016. -L252 White 13/80/252 10 7315885197442 10002127 5197 440 Former Former to be used when making cavities in in-cavity fl oors, or as an alternative to a screeded fl oor box in screeded fl oors. To be placed on the fl oor slab before the concrete is poured. As soon as the concrete has hardened, the former can be removed. Material: EPS (foamed). -RF White 115/340/340 5 7315885197923 10002151 5197 920 For -900 9 (16)

P71461 Floor outlet box -800 Description -800 is a round fl oor outlet box for dry premises. For casting in concrete, -800 should be used with screeded fl oor box -IG or former -RF. -800 requires a minimum depth of 70 mm in a fi nished fl oor and a hole with a diameter of 305 ±1 mm. Grid The grid holds up to twelve outlets for 230 V (CYB-PS triple Schuko). In the three F80 openings in the grid, fi ve standard outlets o84 mm, can be installed. The grid also has four 17.5x18.2 mm knockouts for RJ 45 LexCom. The grid is attached to matrix positions in the trim frame with four combined lifting handles/fasteners. The matrices have a pitch of 5 mm and require a fl oor depth from 70 to 100 mm. The internal unobstructed depth of the fl oor outlet box is then 15 to 45 mm. A minimum fl oor depth of 75 mm is required for an angled standard plug in a schuko outlet, and a fl oor depth of at least 85 mm is required for an angled data cover (CYB-BK1). The grid can be detached from the trim frame and lid, which means that it can be supplied separately and installed in conjunction with other installation work. Trim frame and lid The trim frame is available in two different colours, with a lid that can be trimmed with any material of up to 5 mm thickness. The patented fl oor fi xing devices function ir-respective of the depth of the fl oor or the type of wall in the hole. The floor fi xing expands as the screw is inserted, giving a large contact surface and permitting attachment in both hard and porous fl oor materials. The trim frame is provided with a fl ange that bears upon the fl ooring to conceal the edge of the hole and to outbalance the loads exerted on the box. The lid can be opened in two positions; either through 80, in which case it is self-closing, or through 180 during service. The lid can be installed facing in four directions (at 90 intervals) without having to rotate the installation. The lid is reinforced with a 4 mm sheet steel plate. The strength has been tested according to DIN VDE 0634 Part 1 and it fulfi ls requirements according to PSA Specifi cation MOB PF2 Jan. 1992. Description of the strength tests and test results are available on request. Degree of protection Complies with IP20 in accordance with IEC 529. Cable capacity 1200 mm 2 max. Ø 13 mm in the cable exit. Standards DIN VDE 0634 Teil 1 PSA Specifi cation MOB PF2 PS, Jan 1990 Approvals VDE. Material data PA6.6 with 35% glass-fi bre Density: 1.45 g/cm 3 Linear expansion: 20x10 6 m/m C Water absorption: 1.1% Volume resistivity: >10 13 Ω cm Dielectric strength: 70 kv/cm UL 94 V-0 (halogen-free) Black PA6.6 with 30% glass-fi bre Density: 1.35 g/cm 3 Linear expansion: 40x10 6 m/m C Water absorption: 1.7% Volume resistivity: >10 12 Ω cm Dielectric strength: 70 kv/mm UL 94 HB (0.79 mm halogen-free) Black 10 (16)

Exploded view -800 S10010 3 2 6 1 1. Grid 2. Trim frame 3. Lid 4. Cable holder Design and dimensions 5. Lifting eye/fastener 6. Floor fi xing 7. Lid lifting eye 7 4 5 Material data, cont. PA6 med 15% glass-fi bre Density: 1.25 g/cm 3 (insulation) Linear expansion: 70x10 6 m/m C Water absorption: 2.3% Volume resistivity: >10 13 Ω cm Dielectric strength: 65 kv/mm UL 94 HB Black PA6 (cable holder) Density: 1.13 g/cm 3 Linear expansion: 100x10 6 m/m C Water absorption: 2.8% Volume resistivity: >10 15 Ω cm Dielectric strength: 60 kv/mm UL 94 V-2 (halogen-free) Black PA/ABS Density: 1.12 g/cm 3 Linear expansion: 70x10 6 m/m C Water absorption: 0.9% Volume resistivity: 10 14 Ω cm Dielectric strength: 19 kv/mm UL 94 HB (halogen-free) Colours: Grey RAL 7011 ( NCS 6905-B05G) Anthracite RAL 7016 ( NCS 7905- B02G) PC/ABS Density: 1.14 g/cm 3 Linear expansion: 70x10 6 m/m C Water absorption: 0.6% Volume resistivity: >10 13 Ω cm Dielectric strength: 19 kv/mm UL 94 V-0 (1.6 mm halogen-free) Colours: White RAL 9016 Steel (lid plate) Specifi cation: S 350 GD Material thickness: 4 mm Surface treatment: Galvanized Z 275 Steel (hinge) Specifi cation: S 235 JR Surface treatment: Galvanized Spring steel (lid lifting handle) Specifi cation: DIN 17223 Surface treatment: Fe/Zn 5 c1 Aluminium (cutting template) Specifi cation: AlSi 1.5 Mn Density: 2.6 g/cm 3 Natural Firefl ex (foam cushion) Specifi cation: S305+4610 B1 Grey EPS S15 (polystyrene) Density: 0.015 g/cm 3 White Operative data Compatible with Not compatible with Floors approved for dry cleaning. Raised access fl oors (RAF), in-cavity fl oors, screeded fl oors in conjunction with -IG or former -RF. Boxes CYB and MIB. Outlet system CYB and standard outlets. Floors approved to withstand water. Floors with a smaller construction height than 70 mm. Standard outlets with larger covering plates than 84 mm. Mounting instruction Mounting instruction is enclosed with the product. It is also available on Pl@net. Art. No. 0075144/MI 2030-800 Product Environmental Facts Product Environmental Fact fi les are available on Pl@net. Package info Package information is included in the Prodat fi le, which is available in the SAP system. Package information can also be obtained from the responsible factory. 11 (16)

-800 with accessories Type Colour Dimensions A/B/C (mm) Floor outlet box, complete P67889 P111239 Qty per package EAN code Internal ID-No. Ref. No. Complete fl oor outlet box including grid, trim frame and lid. The lid can be installed in four positions. The grid has three F80 openings (1x284 and 2x142) for installation of power, telecommunications and data outlets, and four 17.5x18.2 mm knockouts for LexCom modular outlet. The knockouts can also be used for conduits when an uninterrupted cable is to pass through the box. The grid is snapped into the trim frame and is adjustable in seven steps from 70 mm to 100 mm. Grid infi ll -L142 to be used to fi ll empty openings in the grid. Suitable for raised access fl oors, in-cavity fl oors and screeded fl oors with a minimum height of 70 mm; in the latter case in combination with screeded fl oor box -IG. Material: PA/ABS, PA6.6 with 35% glass-fi bre, sheet steel S 350 GD. -800 Grey Anthracite 64/Ø329 1 7315885197107 7315880044512 10002097 10002101 5197 100 5197 104 Grid infill Grid infi ll intended to cover space that is not taken up by an outlet. Material: PC/ABS, white RAL 9016. -L142 White 13/80/142 10 7332418017886 20057254 5197 395 P77805 Locking kit Locking kit to be mounted in the lid as an extra protection against unauthorized access; opened by means of a screw-driver. Material: PA6.6 with 30% glass-fi bre. M24220 -LL Black 10/41/153 1 7315885197268 10002111 5197 260 P67893 P67894 Cutting template Cutting template to be used when cutting fl ooring material to size for trimming the lid, or as a spacer when a carpet of 4 mm thickness or thinner is used. Material: Aluminium AlSi 1.5 Mn, natural anodized. -TP800 Anodized 1.5/294/271 1 7315885197909 10002148 5197 900 Former Former to be used instead of core-drilling in in-cavity fl oors, or as an alternative to a screeded fl oor box in screeded fl oors. Material: EPS (foamed). -RF White 120/Ø305 5 7315880053309 10002150 5197 915 12 (16)

Screeded fl oor boxes P1557 A10010 -IG -IG Fig. 1 -IG Floor slab Fig. 2 -IG140 Shuttering Screeded floor boxes -IG Description Screeded fl oor boxes -IG and -IG140 are to be placed on the fl oor slab, which is then covered by concrete screed (fi g.1), or on the shuttering before the concrete is poured (fi g.2). If the shuttering formwork is to be removed after the casting, the box must be placed according to fi g. 2, i.e. with a concrete layer under the box. -IG For -IG the minimum depth of the concrete layer should be 70 mm and 110 mm respectively. -IG can be continuously adjusted to a height of 70 110 mm and 110 150 mm respectively. By using one or several spacer frames -MG, the depth can be increased in steps of 40 mm per frame. All four sides of -IG can be opened for connections by using adaptors -AP for various applications. -AP adaptors are available in three different designs for the connection of pipes or trunkings. The pipe adaptor can be adjusted to four different pipe dimensions by using reduction sleeves. The box is supplied with one side open and the other three sides covered by blank plates, and is provided with a top plate intended to prevent concrete from leaking into the box. After the casting the top plate is to be replaced by installation cover -MP. -IG140 -IG140 is intended for fl oors with a minimum thickness of 140 mm and is adapted to suit fl oor outlet box -140M. Height adjustment of IFB-IG140 is made by using universal supports (not in the delivery programme). Each side of the box is provided with two knock-out openings, adapted to pipe adaptor -AP and Ø25 mm pipes. The top of the box is covered by foamed plastic to prevent concrete and water from leaking into the box. This plastic cover is to be removed before the fl oor outlet box is installed. Fixings for the floor outlet box are included in -IG140. Standards Tested to DIN VDE 0634 Teil 1 and PSA.MOB PF2 PS, Jan 1990. Adaptor -AP and reduction sleeve -RM for pipes with dimensions acc. to EN 60423. Material data Steel Specifi cation: S 235 JR Surface treatment: Galvanized Sheet steel Specifi cation: S 235 JR Surface treatment: Zinc (Z275) Aluminum Specifi cation: AC - AlSi 9 Cu 3 (Fe) Density: 2.7 g/cm 3 PP (polypropylene) Density: 0.905 g/cm 3 Linear expansion: 110x10 6 / C UL 94 HB halogen-free Colours: Yellow NCS 0080-Y20R Blue Grey Natural PP colour 13 (16)

Screeded fl oor boxes Exploded views -IG & -IG140 -IG S11820 3 2 1 6 7 1 Screeded fl oor box -IG 2 Spacer frame -MG 3 Mounting plate -MP -IG140 3 1 4 Stiffening rails 5 Trunking adaptor -AP 6 Pipe adaptor -AP 7 Reduction sleeve -RM 4 2 4 5 Cable capacity Cable dia. Cross section Cable capacity, mm 2 Max Ø area, mm 2 40% 50% 60% Pipe adaptor -AP 37 1040 416 520 624 Pipe adaptor -AP + -RM 40 35 984 394 492 590 Pipe adaptor -AP + -RM 32 27 606 242 303 364 Pipe adaptor -AP + -RM 20 16 224 90 112 134 Pipe adaptor -AP + -RM 16 13 132 53 66 79 Pipe adaptor -AP (-IG140) 20 314 126 157 188 Operative data Temperature range From 20 to +60 C Suitable outdoors Not suitable Degree of protection IP 20 Estimated min. length of service More than 15 years Restrictions Only for the mounting of fl oor boxes and post POS-200 Mounting instruction Mounting instruction is enclosed with the product and is also available on Pl@net. Art.No. MI 2024 -IG Product Environmental Facts Product Environmental Fact fi les are available on Pl@net. Package info Package information is included in the Prodat fi le, which is available in the SAP system. Package information can also be obtained from the responsible factory. 1 Screeded fl oor box -IG140 2 Hole for pipe adaptor 3 Fixing screw for -140M 4 Cover (cellular plastic) Design and dimensions -IG & -IG140 M20100 -IG The measure H must not be smaller than the stated minimum screed depth for fl oor outlet boxes. Type H, mm Remarks -800 75/85 75 mm for 250 V, 85 mm for angled CYB data -700/900 110 CYB, CAN -700/900 115 MIB-A1, -A2 -IG140 14 (16)

Screeded fl oor boxes -IG with accessories Type Colour Dimensions A/B/C (mm) Screeded floor box for floors 70 110 mm P67895 Qty per package EAN code Internal ID-No. Ref. No. Screeded fl oor box for floor embedment in screeded fl oors from 70 to 110 mm thickness. For floors thicker than 110 mm, add spacer frame -MG as an enhancement. The box height is adjustable, the adjustment being made in all four corners to make it possible to always level the box to the fi nished fl oor. The box is supplied including spacer frame and three blank plates -AP. Suitable for fl oor outlet boxes type and service posts type POS mounted in mounting plate -MP. Material: Sheet steel S 235 JR, aluminium AC - AlSi 9 Cu 3 (Fe). -IG Galvanized 110/455/455 1 7315885197565 10002129 5197 560 Screeded floor box for floors 110 150 mm Screeded fl oor box for floor embedment in screeded fl oors from 110 to 150 mm thickness. For floors thicker than 150 mm, add spacer frame -MG as an enhancement. The box height is adjustable, the adjustment being made in all four corners to make it possible to always level the box to the fi nished fl oor. The box is supplied including spacer frame and three blank plates -AP. Suitable for fl oor outlet boxes type and service posts type POS mounted in mounting plate -MP. Material: Sheet steel S 235 JR, aluminium AC - AlSi 9 Cu 3 (Fe). -IG Galvanized 140/455/455 1 7315880047681 10002130 5197 565 P67896 Spacer frame Spacer frame to be screw-fastened to screeded fl oor box -IG, increasing the height by 40 mm. Several spacer frames can be mounted on top of one another to further increase the height. Material: Aluminium AC - AlSi 9 Cu 3 (Fe). -MG 47/370/370 1 7315885197558 10002128 5197 550 P67901 P67900 P67898 P67897 P67899 Blank plate Blank plate to be fi tted to the side entrance of screeded fl oor box -IG. Material: Sheet steel S 235 JR. -AP 1.5/55/257 10 7315880046813 10002135 5197 750 Blank plate Floor trunking adaptor for 28 mm high trunking Adaptor to be fitted to the side entrance of screeded fl oor box -IG for the connection of 28 mm high fl oor trunking to the box. Material: Sheet steel S 235 JR. -AP 55/40/257 10 7332418017633 20057045 5197 761 For 150x28 mm fl oor trunking -AP 55/40/257 10 7332418017640 20057046 5197 762 For 200x28 mm fl oor trunking -AP 55/40/282 10 7332418017657 20057048 5197 763 For 250x28 mm fl oor trunking Floor trunking adaptor for 38 mm high trunking Adaptor to be fitted to the side entrance of screeded fl oor box -IG for the connection of 38 mm high fl oor trunking to the box. Material: Sheet steel S 235 JR. -AP 55/40/257 10 7332418017664 20057049 5197 771 For 150x38 mm fl oor trunking -AP 55/40/257 10 7332418017671 20057050 5197 772 For 200x38 mm fl oor trunking -AP 55/40/282 10 7332418017688 20057051 5197 773 For 250x38 mm fl oor trunking Pipe adaptor Adaptor for the connection of 1 4 pipes Ø 50 mm (dimensions acc. to EN 60423) to screeded fl oor box -IG. When required, the pipe dimension can be reduced by reduction sleeve -RM. All pipe entrances are provided with knock-out opening. Material: PP. -AP Yellow 55/40/257 10 7315885197756 10002136 5197 755 Reduction sleeve Reduction sleeve for the connection of pipes in adaptor -AP. The reduction sleeve is available for four different pipe dimensions: Ø 16, Ø 20, Ø 32 and Ø 40 mm (dimensions acc. to EN 60423). The hole for the pipe connection is positioned at the bottom edge of the reduction sleeve, for a steady position of the pipe. Material: PP. -RM Yellow Ø50/39 10 7315885197824 10002144 5197 820 For pipes Ø 16 mm -RM Yellow Ø50/39 10 7315880046820 10002145 5197 825 For pipes Ø 20 mm -RM Yellow Ø50/39 10 7315885197831 10002146 5197 830 For pipes Ø 32 mm -RM Yellow Ø50/39 10 7315880046837 10002147 5197 835 For pipes Ø 40 mm 15 (16)

Screeded fl oor boxes -IG with accessories Type Colour Dimensions A/B/C (mm) Installation cover Qty per package EAN code Internal ID-No. Ref. No. Installation cover for fl oor boxes and service post POS-200, to be mounted in screeded fl oor box -IG. Material: Sheet steel S 235 JR, zinc coated. -MP Galvanized 3/361/361 1 7315880046851 10002139 5197 780 Blank plate -MP Galvanized 3/361/361 1 7315885197787 10002140 5197 785 For -700 -MP Galvanized 3/361/361 1 7315880046844 10002141 5197 790 For -800 -MP Galvanized 3/361/361 1 7315885197794 10002142 5197 795 For -900 -MP Galvanized 3/361/361 1 7315885197800 10002143 5197 800 For POS-200 -IG140 with accessories Screeded floor box Screeded fl oor box for floor embedment of fl oor outlet box -140M. The box is provided with eight knock-out openings adjusted for pipe adaptor -AP and includes a cover of cellular plastic to prevent concrete and water from leaking into the box. Material: Sheet steel S 235 JR, zinc coated. -IG140 110/180/180 1 7315880109952 20045123 5197 567 P67902 P67903 P67906 Pipe adaptor Pipe adaptor for Ø25 mm pipes. Material: PP. -AP Blue Ø35/50 25 7315880110088 20045553 5197 839 16 (16)