MIRacle Single Reflection ATR: Design and Performance Features

Similar documents
MIRacle ATR Fast and Easy IR Sampling

Attenuated Total Reflectance (ATR)

Installation and User Guide. HATR Horizontal ATR Accessory

MIRacle TM Single Reflection Horizontal ATR Accessory

Reflectance. Theory and

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Installation and User Guide. HATR Flow Cell, Jacketed Flow Cell, Heated Flow Cell for Horizontal ATR Accessories

Analysis of Inorganic Materials with the Pike MIRacle AG Diamond Horizontal ATR

How to Choose the Right Smart Accessory

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

FTIR, NIR and UV-Vis

INNOVATING INFRARED SPECTROSCOPY PRODUCT BROCHURE ATR CRYSTALS

How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products. Presented by: Dr. Yanqia Wang

Analysis of strongly absorbing chromophores by UV-visible ATR spectroscopy

SUPER-SEALED LIQUID FLOW CELLS OPERATION AND USER MANUAL

Q. sample preparation for FTIR & How to sample introduce in the system?

Product Catalogue 2014

FTIR Series Accessories

Product Catalogue

MB3000-PH. FT-IR Spectrometer for the Pharmaceutical Industry Designed for QA/QC, Formulation, Research and Development Laboratory Applications.

In IR it is usual to express the wavelength in micrometers (microns), 1 micro = 10-6 m, or in wavenumbers, cm -1.

Global Journal of Engineering Science and Research Management

Fused Silica: Bakeout to 200 C Operating Temperature -65 C to 150 C Standard Transmission Range 0.25 to 2 microns

The DC-3 Diamond Compression Cell User Manual

Unrivaled. Sensitive. Flexible. Agilent Cary 600 Series FTIR

MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications

BLOCK COPOLYMERS ORGANIZATION AT INTERFACE

Composite heat damage measurement using the handheld Agilent 4100 ExoScan FTIR

The KBr window pane on our liquid cell has turned a cloudy white color. Is there any problem continuing to use it the way it is?

Dielectric II-VI and IV-VI Metal Chalcogenide Thin Films in Hollow Glass Waveguides (HGWs) for Infrared Spectroscopy and Laser Delivery

Flexible. Accurate. Intuitive. AGILENT CARY 100/300 SERIES UV-VIS SPECTRoPHOTOMETERS

Coatings. Ion Assisted Deposition (IAD) process Advance Plasma Source (APS) plasma-ion assisted Deposition. Coatings on Optical Fibers

Determination of Hydrocarbons in Environmental Samples with Spectrum Two

Thermo Electron Smart Golden Gate MKII Single Reflection ATR System Sampling Notes

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC.

Attenuated Total Reflection of DielectricMetal Interfaces* D. M. Haaland. Sandia National Laboratories, Albuquerque, New Mexico 87185, U.S.A.

25 Reflection Variable Angle ATR User Manual


NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Thermo Scientific ARL EQUINOX X-ray Diffractometers

VACUUM VIEWPORTS. Introduction... I 03 KF Viewports... I 09 I 01. VACUUM / Components & Consumables

The MIDAC Low Moisture in Corrosive Gases Process Analyzer for Continuous On-Line Applications

ise J. A. Woollam Ellipsometry Solutions

8. PYROMETRY FUNDAMENTALS

Standard Practice for Identification of Polymer Layers or Inclusions by Fourier Transform Infrared Microspectroscopy (FT-IR) 1

Fluorescence & UV- Visible Workshop

Hot Water Aging Performance of Silica Optical Fiber with Single Coating Characteristics

Cavity Filters. KIGRE, INC., 100 Marshland Road, Hilton Head, SC 29926, USA PH: FAX: Web:

OPTIMIZING XRD DATA. By: Matthew Rayner

S8 TIGER Series 2. Lab Report XRF 144. Innovation with Integrity. Accurate Quality Control of Tool Steels XRF

Thermo Scientific Nicolet is10 FT-IR Spectrometer. Complete infrared spectroscopy system. for routine analytical needs

Transmission. Theory and

Total Internal Reflection Fluorescence Microscopy

SUPPLEMENTARY MATERIAL FOR THE PAPER

Department of Biophysics, University of Mumbai, Vidyanagri, Santacruz (E), Mumbai Tel ,

ProCell - Process Flow Cells Enabling continuous online spectroscopic analysis in the UV/Vis and NIR

BASF Corporation. Abstract. Introduction. Basic Principles for LW of Thermoplastics. Non-Contact Laser Welding (NCLW)

INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR INFRA-RED PYROMETERS IPSS:

About us. Capabilities

Plastic Coated Silica/Silica (Low OH) FIBER CROSS SECTION Polyimide and Acrylate Coated. Nylon and Tefzel Coated

16.2 Scanning Infrared Spectrometers

Micro Laser Assisted Machining (µ-lam) of Semiconductors and Ceramics. Machining Direction

FTIR Series Accessories

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

The Benefits of a Vertically Integrated Optical Systems Supplier

FT-IR Protein Structure Analyzer. Speed Sensitivity Simplicity

Standard Optics Information

FOR ANY IR READY CHALLENGE.

Instrument Configuration for Powder Diffraction

Introduction to Polymer-Dispersed Liquid Crystals

Illuminating Innovations

Optical Coatings. Phone: Fax: Domostroitelnaya str St. Petersburg, Russia

FT-IR. varian, inc. 660/670/680-IR.

Fiber and Electro-Optics Research Center Virginia Polytechnic Institute and State University Blacksburg, Virginia 24061

Characterization of Li 3+ /Mg SO 4.7H 2 O Crystal

Pharmaceutical Packaging Materials Quality Control and USP Compliance: Agilent Cary 630 FTIR

Heraeus Quarzglas GmbH Co.KG Fluosil Preform

ANALYSIS OF MINING SAMPLES USING INFRARED SPECTROSCOPY AND MACHINE LEARNING MATLAB CONFERENCE PERTH, MAY 2017

Bioreactor Monitoring: A New Application for the ChemDetect Liquid Analyzer

Physics 6180: Graduate Physics Laboratory. Experiment CM5: X-ray diffraction and crystal structures

Chapter 7 Evaluation of Injection-Molding Phenomena Part 1: Measurement of temperature distribution in the molded materials

Study of a-sige:h Films and n-i-p Devices used in High Efficiency Triple Junction Solar Cells.

Multilayer Silver / Dielectric Thin-Film Coated Hollow Waveguides for Sensor and Laser Power Delivery Applications

Ytterbium-doped Aluminum-codoped Sol-Sel Silica Glass Fiber Laser

Thermo Scientific Antaris II Near-IR Analyzers. with superior engineering comes instrument matching and method transferability

Introducing Jie Huang. Presentation to the Academy of Electrical and Computer Engineering, April 21, 2016

APPLICATIONS OF CHALCOGENIDE GLASS BULKS AND FIBRES

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Superstructure Fiber Bragg Grating based Sensors

Fundamentals of X-ray diffraction and scattering

UV/Vis Spectrophotometry. Time for New Demands SPECORD PLUS

FTIR Infrared Polarizers GS12000 Series User Manual

Click here to continue >

Thermo Scientific ARL EQUINOX 100. X-ray Diffractometers

APPLYING ULTRASOUND FOR IN-LINE INSPECTION: FACTS AND ISSUES. By Dr. Michael Beller, NDT Systems & Services AG, Stutensee, Germany

REVIEW OF LASER PLASTIC WELDING PROCESS

Laser Raman Spectrometer

INDUSTRIAL INFRARED PYROMETERS. Williamson - Where Wavelength Matters

Applications. Application Note. Kingbright

Transcription:

MIRacle Single Reflection ATR: Design and Performance Features The single reflection attenuated total reflectance (ATR) accessory has become one of the most popular means of sampling for Fourier transform infrared (FTIR) spectroscopy. In general this sampling technique provides fast analysis by eliminating sample preparation, especially if the ATR accessory is well designed and provides high throughput relative to the available energy in the FTIR sample compartment. This document provides comparative information and data to assist in the selection of the best crystal material for specific ATR sampling applications. Furthermore, the design of the crystal is important because it contributes to each of these factors in a way that either increases or diminishes the performance of the ATR accessory. Some of the crystal design factors to consider are the size of the ATR crystal and how well it accommodates liquids, solids and other sample forms. Experimental Spectral data were measured using a MIRacle single reflection ATR accessory on an FTIR spectrometer. The MIRacle ATR was equipped with a high pressure clamp and a crystal plate appropriate for the application. All spectral data were collected at 4 cm -1 resolution using 1 minute sample and background data collection time. ATR Crystal Optical Design The size of the ATR crystal is important. A larger size increases IR throughput by minimizing vignette of the IR beam, whereas a smaller sampling size enables increased force per unit area for improved contact with rigid samples. Therefore, we would like an ATR crystal as small as possible with highest IR throughput. Such a design was created in 1999 with the introduction of the MIRacle ATR accessory for FTIR 1 and continues to be the most widely used ATR. In this unique optical design the ATR crystal is combined with the focusing optic into an optimized sampling interface characterized in Figure 2. Figure 1. MIRacle Single Reflection ATR accessory Evanescent Wave Diamond ATR Crystal Base ATR Focus Optics There are several factors to consider when choosing the ideal crystal material for the single reflection ATR accessory: Throughput Spectral range Crystal material hardness and ph tolerance Refractive index Each of these factors may be an important part of the decision relative to your analysis and application. IR Beam OUT IR Beam IN Figure 2. Crystal design for MIRacle ATR accessory. The refractive index of the base ATR focus optic and its lens shape combine to focus the IR beam to a smaller dimension. The IR beam is focused at the face of the circular 1.8 mm diameter ATR sampling surface after internal reflections

within this optical element. If the ATR crystal is a composite as with the MIRacle diamond, the base ATR focus optic is formed into intimate contact with the diamond ATR sampling crystal, providing direct transmission of the IR beam to the sampling surface. When a sample is placed into contact with the ATR sampling crystal and subjected to IR radiation, an evanescent wave projects into the sample and some of this wave is absorbed by the sample and is measured as an infrared spectrum. 2 ATR Accessory Throughput Accessory energy throughput is a very important consideration relative to achievable spectral quality. As more energy is delivered to the FTIR detector, the signal-to-noise ratio (SNR) in our spectral data increases. Accessory throughput is measured by collecting a sample spectrum of the accessory ratioed to the open beam FTIR background spectrum. Figure 3 shows the accessory throughput spectrum for the MIRacle diamond/znse crystal plate. At 1000 cm -1 this spectrum shows greater than 45% throughput, which is an excellent result. Figure 4. Monofilament fiber by single reflection ATR accessories. A single 200 micron diameter monofilament fiber was run on single reflection ATR accessories with a diamond crystal. The red spectrum was obtained from the MIRacle ATR accessory. The blue spectrum was obtained from another diamond ATR accessory with lower IR throughput. These 2 spectra are displayed in equivalent y-scaling. The spectrum obtained using the MIRacle exhibits higher signal and lower noise significantly higher SNR. Size of ATR Crystal The size of the ATR crystal is an important factor relative to ensuring adequate pressure upon the sample to create intimate contact with solid samples. Solid samples must be pressed firmly against the ATR crystal to provide a significant absorbance of the evanescent wave. Figure 3. Throughput spectrum for diamond/znse crystal plate on MIRacle ATR. For routine sample analysis such as material identification when the sample is sufficient size to cover the ATR crystal and pliable enough to conform to the flat crystal surface, most modern ATR accessories will suffice. However for more challenging samples, the differences in spectral quality produced from a high throughput ATR accessory and one of lower performance will become apparent. A machinable polymer is very hard; however, using the full force of the high pressure clamp with the 1.8 mm diameter MIRacle ATR crystal pressed upon the sample an excellent spectral result is obtained. As seen in Figure 5 on the following page, the spectrum obtained at low pressure (upper red) produces absorbance bands at significantly lower intensity and demonstrates the need for high pressure for this type of sample.

Design for Sample Form The ATR crystal plate design needs to accommodate solid, liquid, gel, paste or polymer sample forms. The MIRacle crystal plate is designed as a sealed flat plate for solids and liquid samples. For highly volatile liquids, a liquids retainer/ volatiles cover and a flow cell are available. Figure 5. Spectra of machinable polymer using MIRacle ATR with diamond crystal plate using low and high pressure. The small diameter of the MIRacle ATR crystal is ideal for small amounts of liquid or solid samples. In theory, a liquid volume as small as 5 nanoliters would be sufficient to generate a strong IR spectrum with 2 micron coverage over the 1.8 mm diameter MIRacle ATR crystal. The sensitivity of the MIRacle ATR for a small volume is demonstrated in Figure 7. At a given force applied to a sample, the area of the ATR crystal face will determine the final pressure applied to the sample. Figure 6 shows pressure in pounds per square inch (psi) vs. crystal diameter using a force of 40 pounds applied by the MIRacle High Pressure Clamp. In this graphic we can see the exponential rise in pressure upon the sample as the crystal diameter decreases. The MIRacle ATR accessory with its 1.8 mm diameter crystal and high pressure clamp provides 10,141 psi of pressure upon a sample ensuring high quality spectra of solid samples. We do not recommend application of high pressure onto hard samples with all of our available ATR crystal materials as will be discussed later in this article. Figure 7. Liquid skin care product on MIRacle ATR. The sample in Figure 7 is a medicated liquid skin care product. About 1 microliter of the liquid is applied to the MIRacle ZnSe crystal plate and the sample spectrum is recorded. It is seen in this spectrum that the MIRacle ATR is a very sensitive analytical tool. Refractive Index of ATR Crystal Figure 6. Pressure vs. crystal diameter with force of 40 lbs. Selection of the crystal material provides a valuable means of controlling the sampling depth and ensuring we meet critical angle requirements for ATR analysis. At 45 degrees angle of incidence and a sample refractive index of 1.5, the depth of penetration of the IR beam into the sample varies from 0.6 microns for the germanium (Ge) ATR crystal to 2.0 microns for the diamond and ZnSe crystals as measured at 1000 cm -1. These differences are useful to optimize the results for thin

coatings or for analysis of samples with high refractive index such as a carbon filled rubber sample. The spectra in Figure 8 are similar relative to the major absorbance bands. Close inspection of the data reveals derivative shaped absorbance bands in the spectrum collected using the ZnSe crystal due to critical angle requirements. This problem is not found in the spectrum produced using the higher refractive index Ge ATR crystal. The easily changeable, pin-mounted crystal plates of the MIRacle help to make optimization of the ATR result an easy task. NOTE: In Figure 8 the baseline shift at long wavelength in both of these spectra is expected due to wavelength dependent absorbance by high carbon content. Hardness of the ATR Crystal Since the ATR crystal is in intimate contact with the sample either without the need for pressure as in the case of liquid samples or with pressure in the case of solid samples, its hardness is an important factor in the design of your ATR accessory. Typical ATR crystal materials for single reflection ATR accessories range in hardness from ZnSe to diamond and their relative hardness specifications are summarized in Table 1. Generally speaking, the relatively softer ZnSe is an excellent crystal choice for liquid samples, soft powders, gels, and polymer films. ZnSe is less expensive compared to diamond and the crystal plate can be refurbished if scratched. Conversely, diamond is extremely hard and compatible with almost all sample types. Its wide ph tolerance range and crystal hardness will offer years of service. The spectrum of a hard polymer pellet run using the MIRacle ATR with diamond/znse crystal is shown in Figure 9. Due to the hardness of diamond, it is safe running this sample directly. With the ZnSe crystal, we would need to flatten the surface before application of high pressure to prevent damage. Figure 8. ATR spectra of carbon filled rubber sample using Ge (upper red) and ZnSe (lower blue) crystal plates. Table 1. MIRacle ATR Plate Properties. MIRacle Crystal Plate Application Diamond/ZnSe Ideal for hard samples, acids or alkaline ZnSe General purpose ATR sampling Ge General purpose and carbon-filled samples Si Excellent for far-ir spectral measurement Hardness kg/mm 2 LW Cutoff cm -1 Refractive Index d p (µ) @ 45, 1000 cm -1, n 2 1.5 Safe ph Range 5700 525 2.4 2.00 1 14 120 525 2.4 2.00 5 9 780 570 4.0 0.66 1 14 1150 475-40 3.4 0.82 1 12

Summary A high throughput, single reflection ATR accessory configured with an appropriate ATR crystal and high pressure clamping device is capable of providing excellent FTIR spectra of solids, liquids, polymers and many other sample types. References 1. United States Patents 5,965,889 & 6,128,075, Philip R. Brierley, PIKE Technologies, 1999, 2000. Figure 9. Hard polymer pellet on MIRacle ATR with diamond/znse crystal. 2. Mirabella, Francis M.: Internal Reflection Spectroscopy, Marcel Dekker, Inc. (1993). Spectral Range of the ATR Crystal The ATR crystal material and the pathlength of the IR beam through it will define the spectral range available. In some cases the long wavelength spectral range is critical for seeing absorbance bands near the spectral cut-off of the crystal material. Table 1 shows long wavelength spectral range for the MIRacle ATR for each of its crystal configurations. ATR depth of penetration is directly proportional to the wavelength of the probing beam. Furthermore, absorbance of near-ir energy being overtones and combination bands from the mid-ir spectral region is relatively weak compared to absorbance in the mid-ir spectral region. Therefore ATR spectral range toward the short wavelength side of the spectrum is of less importance. Safe ph Range For most samples analyzed by ATR this is not an issue; however, for strongly acidic or caustic samples good choices are available. Both diamond and Ge tolerate a full range of sample ph (Table 1). The MIRacle crystal plate is available in Hastelloy metal, as an option. Hastelloy is fully resistant to acidic and basic samples and is recommended for corrosive samples.