AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

Similar documents
AS The External Waterproofing Membranes Standard

Balconies Information. How to waterproof and reduce efflorescence

FUNCTIONAL REQUIREMENTS

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

WPM WATERPROOFING MEMBRANE

National Construction Code Series (NCC 2016) Building Code Of Australia (BCA)

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS

4422WE SEALCO EPIROOF & EPISPAN EPDM MEMBRANES

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

DS411 Exterior. Product. BRANZ APPRAISAL No. 788 (2012) Scope. Wet-seal New Zealand Ltd P O Box Takapuna Auckland Tel:

4422WT SEALCO ECOROOF ECOTUFF TPO GREEN ROOF WATERPROOFING MEMBRANE

LIQUID APPLIED WATERPROOF ROOF COATINGS

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Waterproofing Handbook

FirstEnergy Program Overview

roofing ROOFING Design of the base ROOFING DETAILS

DRYPROOF UNDER TILE EXTERNAL WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 887 [2015] Appraisal No. 887 (2015) Amended 17 September 2015

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

A. Section includes fluid applied, vapor permeable membrane air barriers.

RUBBERGUARD LIQUID APPLIED WATERPROOFING

DAVCO K10 PLUS AND K10 RAPID EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 608 [2017]

LIQUID APPLIED WATERPROOF ROOF COATINGS

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to Felt (Waterproofing Only)

METHOD STATEMENT 003 SCYRON-CEMENT SHEETING BALCONY WATERPROOFING FOR DIRECT FIXED TILES

4422WT SEALCO ECOTUFF TPO SUPERROOF WATERPROOFING MEMBRANE

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

11/09/2018 LBP licence classes

METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES

Wet Areas Using Plasterboard

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

SECTION FLUID-APPLIED WATERPROOFING

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

MAPELASTIC, MAPELASTIC SMART AND MAPELASTIC TURBO EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 485 [2018]

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

ECOTUFF TPO ROOF AND DECK MEMBRANE. Product. Scope. Appraisal No. 792 [2012] Appraisal No. 792 (2012) Amended 05 October 2016.

FIRESTONE RUBBERCOVER EPDM MEMBRANE. Product. Scope. Appraisal No. 893 [2015] Appraisal No. 893 (2015) Amended 24 November 2017.

Installation Guidelines INOFIN FR

roof membranes Product BRANZ APPRAISAL No. 307 (2013) Scope

SPECIFICATION JAYDEX SHEET MEMBRANE SYSTEM WITH AN ASPHALTIC OVERLAY ON A CONCRETE VEHICLE DECK

VIKING ENVIROCLAD ROOFING AND DECK MEMBRANE. Product. Scope. Appraisal No. 656 [2015]

Product. BRANZ APPRAISAL No. 436 (2011) Scope. Ardex New Zealand Limited P O Box Woolston Christchurch

WARMUP TILED SHOWER SOLUTION

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. Showers & Bathrooms. Balconies & Patios SUITABLE SUBSTRATES. for application on: Concrete & Masonry

AQUABLOK EXTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 723 [2017]

SRP-AirOutshield UV Issued:

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Architectural Roofing

ONE PART POLYURETHANE. Flexible, UV Stable, Moisture cured polyurethane membrane suitable for use on light foot traffic roofs. Hard top Surfacing

SECTION SELF-ADHERING SHEET FLASHING

SOPREMA JARDIN Double Layer Torch-on membrane For water proofing roof gardens and planters

DELTA -GARDEN ROOF ASSEMBLY Master Guide Specification Page 1

ReflectiClean Acrylic/Urethane

ARDEX UNDERTILE SHEET MEMBRANE (WPM 750 AND WPM 1000) Product. Scope. Building Regulations. Appraisal No. 727 [2017]

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

NURAPLY 3PM ROOFING MEMBRANE INSTALLATION CHECKLISTS

BUTYNOL AND BUTYSEAL ROOFING MEMBRANE SYSTEMS. Product. Scope. Appraisal No. 436 [2017]

ELEVATION FOR DETAIL REFERENCE ONLY

SECTION 07530CP EPDM MEMBRANE ROOFING

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

DAVCO K10 PLUS AND K10 RAPID WET AREA MEMBRANES. Product. Scope. Building Regulations. Appraisal No. 609 [2017]

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

Regarding the code-compliance of a channel drain around the foundation of a house and garage at 533 Waitoki Road, Wainui, Auckland

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

WET AREA CONSTRUCTION AUSTRALIA SEPTEMBER 2006 DESIGN MANUAL

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

TECHNICAL ASSESSMENT 338

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

durotuf TPO WATERPROOFING MEMBRANE Product Scope Appraisal No. 950 [2017] Appraisal No. 950 (2017) Amended 24 May 2018 BRANZ Appraisals

New Residential Building and Major Alterations / Additions

DAMPFIX GOLD EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 744 [2017]

J41 Reinforced bitumen membrane roof coverings

PERMAPHALT MASTIC ASPHALT ROOF WATERPROOFING SYSTEM. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

J41 Reinforced bitumen membrane roof coverings

Commercial Flashing Details

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

tra-load Damp Proof Courses Product and Systems Overview

GUARANTEED ASPHALT LIMITED

Technical Data Sheet

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

Student Services & Classroom Addition

ROOFING APPLICATION STANDARD (RAS) No. 109

J41 Reinforced bitumen membrane roof coverings

Fix Leaking Balconies Balcony Assessment

ARDEX UNDERTILE WET AREA MEMBRANES. Product. Scope. Building Regulations. Appraisal No. 702 [2017]

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals

BLACKSEAL SB DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 585 [2016]

WeatherSmart Air Barrier Installation Guide

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

Waterproofing Systems

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

Transcription:

AS4654.2 Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings Climate Zone: 6 Wind Class: N1 Membrane Types: Liquid Applied Class II and Class III as defined and tested in accordance with AS4858 and suitable for use relating to AS4654.1 All membranes we recommend for use are capable of servicing the conditions, namely: UV Stable Heat aging tested Operating Temperatures Bio-resistant Water immersion tested Chemical resistant SUBSTRATE Both builder and waterproofer need to check the substrate material in contact with the waterproofing ensuring that it shall be suitable for, and compatible with, the waterproofing membrane system. Additionally, the substrate is to be resistant to moisture damage caused by condensation forming on the underside. NB: particleboard sheeting shall not be used, plus tile and slate underlay is un-acceptable. Suitable substrate materials refer: AS3600 AS3700 AS1684 AS2269 AS2908 Concrete Masonry Timber Plywood Cellulose-cement 1

Falls: The fall can be formed in the structural substrate or formed by a screed over the structural substrate, which must not be less than 1 in 100 (10mm per 1m). Falls in finishes must ensure water drains to the drainage outlet, with no water retention on the finished surface. 2

LAYING MEMBRANES Junctions, lap joints, seams and cold joints: Liquid applied membranes usually don t have a manufacturer s description covering these issues relating to the weak points in sheet systems. However, should the liquid applied system incorporate reinforcing fabric a lap joint, usually a min of 40mm is applicable. Curing: All components of the membrane system must be cured before considered fit for purpose. Considerations for liquid applied membrane systems are: Low temperatures, wet film thickness, relative humidity, solids content and air movement can delay curing. No further work should be commenced until the membrane is cured Premature covering of the membrane may prevent curing and lead to degradation. Intervals between applied membrane coatings should take into account the necessary curing times. FILLETS When a membrane changes from horizontal to vertical plane it requires a bond breaker application. Membrane Class Elongation at break Min bond breaker/tape width to bridge joints opening up by 5mm II 60% to 300% 35 mm III >300% 12 mm TERMINATION OF MEMBRANES Upward terminations: Height: The membrane termination is created to prevent water entry, the finished height of the membrane should cater for the surface coverage height to prevent water, including wind driven, from flowing over the top of the membrane. In wind class N1 the termination height must be not less than 40mm Membrane termination finishing: The Standard is mostly concerned with sheet membranes relating to over-flashing or coverflashing, However some points relate to liquid applied:- Termination of a pressure seal flashing: Pressure seal flashing to be attached using mechanical fixings at a maximum of 150mm centres. The lap from the bottom edge of the mechanical fixing, to the bottom edge of the pressure seal flashing shall be a minimum of 15mm. 3

Sealant to encapsulate the pressure seal flashing to the weatherproof wall There is to be a minimum of 10mm gap between the bottom of the flashing and the finished level. Termination of overflashing: The overflashing is to be attached into the waterproof wall via a rigulet of minimum 15mm and fixed in place, inclusive of sealant The lap from the top edge of the sealed rigulet to the bottom of the membrane is a minimum of 75mm The gap between the bottom of the flashing and the finished level must be a minimum of 10mm VERTICAL UPWARD TERMINATION DETAIL OF PRESSURE SEAL 4

VERTICAL UPWARD TERMINATION DETAIL OF OVERFLASHING Vertical downward terminations: Roofs: Vertical downward terminations for roofs or similar structures using a reinforced (or sheet) membrane need to extend a minimum of 100mm from the junction. VERTICAL DOWNWARD TERMINATION PRESSURE SEAL 5

Parapets: The top edges of the membrane is to be protected by the downturn of the cavity flashing. 6

Gutter Termination: A metal angle with a vertical leg of a minimum of 35mm is to be fixed to the substrate. Doors and windows onto external waterproofed areas: The following applies for doors and windows onto external waterproofed areas: Subsill flashing to be included as part of the membrane system. Where the internal and external finished floor levels do not allow an upturn :- o The deck surface must fall away from the grate; and o The grate is to be to the width or greater than the opening If the fixing of the sill/subsill is required, it is to be done horizontally to an angle behind the door sill/subsill. 7

Penetrations: Any fixings that penetrate the membrane must be sealed. The sealant is to be compatible with the surface material. Where a backing rod is used in support of the sealant, they shall be a minimum of 12mm TERMINATIONS AT WALL OPENINGS WHERE INTERNAL AND EXTERNAL FLOOR LEVELS DO NOT ALLOW AN UPTURN PENETRATION USING A COLLAR 8

METAL POST SUPPORT PENETRATION TYPICAL PENETRATION 9

Skylights: The membrane is to be upturned at the skylight to prevent water entry to a minimum of 40mm MOVEMENT AND CONTROL JOINTS Where a building or structure has construction joints, movement joints or control joints, the membrane is to be either discontinuous over the joint or continuous, to allow for the designed anticipated movement. Where continuous joint is installed, the membrane is to be unbonded for the first 100mm. DISCONTINUOUS CONTINUOUS 10

DRAINS The membrane is to be connected to the stormwater drainage system through a down turn of membrane into the inlet. Other connections could have a flange for the membrane to be attached. The installation of the drain should include a sump, inlet pit, grate or cage, to minimize blockage from debris 11

12

OVERFLOWS The membrane must be turned into the overflow to prevent moisture from tracking behind the membrane. 13

CHANGES IN DIRECTION OR UPSTANDS Any changes of direction for the membrane from horizontal to vertical is to follow the same criteria as expressed in MOVEMENT AND CONTROL JOINTS Bond breakers are to be used where movement between substrates is expected. Upstands & Hobs (piers, posts, etc.) are to be treated as with the detail outlined in TERMINATION OF MEMBRANES PLANTER BOXES The membrane is to be sealed to the drainage outlet and extend vertically to a height of 100mm above the soil or fill level. Falls in the planter box should be a minimum of 1 to 100 (10mm per 1 m) A suitable overflow should be provided Protection board should be installed to minimize root damage to the membrane Externally exposed walls of the planter boxes should be waterproofed to prevent failure of the internal membrane. 14

PROTECTION DURING CONSTRUCTION When a membrane system is not designed to be trafficable, the membrane must be protected from damage after installation until covered or finishes are installed. Typically, protection boards, physical barriers, restricted access and elevated walkways are used. OVERLAYING SURFACE FINISHES Where a membrane is to be overlayed with another system (tiles, pavers, ballast, insulation, soil etc), the overlaying system shall be compatible with, and not cause damage to the membrane. Where the topping or bedding mortar is to be bonded to the membrane, sufficient movement joints to be provided in the topping or bedding mortar to accommodate the movement over the membrane. NOTE: for bonded finished, the movement joints are to be located above the movement and control joints in substrate. INSPECTION AND ACCEPTANCE TEST On the completion of the installation of a membrane system, inspection and acceptance testing must be conducted. In addition to the visual inspection, either the dry film thickness test (DFT) by non-destructive means or a controlled water test for a minimum of 24 hours duration is required. 15

BALCONY CONSIDERATIONS DOOR STOP DETAIL 16

TIMBER DECKING OVER WATERPROOFED STRUCTURE 17

BALUSTRADE 18

NOTES BOND BREAKER PRINCIPLE 19

SUMMARY CHECK LIST The following is a summery check list for external waterproofing to meet and exceed the Standard AS4654.2. It is both the builder and the waterproofing contractor s responsibility to understand and comply with the NCC and Australian Standard. This summary is a guide only. 1. Inspect and check the condition of the substrate before waterproofing: Correct substrate materials installed Movement Joints have been installed correctly Flashings are correctly installed Door sills are correctly installed Plumbing and other penetrations have been correctly installed Falls meet or exceed the Standard 2. Choose a Membrane system suitable for site purpose, incorporating final finishes requirements 3. Apply Bond Breaker principle to all fillets, penetrations, vertical and horizontal joints 4. Ensure membrane system extends into drains, overflows, gutters etc. as required. 5. Install falls as required 6. Ensure all upturns and downturns extend to or exceed the Standard 7. Ensure the membrane system is working with the movement and control joints 8. Ensure the membrane system is protected and fully cured 9. Complete a final inspection, plus conduct membrane test 10. Issue a certificate of compliance that the waterproofing has met and exceeded the AS4654.2 References: AS4654.2 Waterproofing membranes for external above-ground use. Part 2: Design and installation MBA NSW: Guide to External Waterproofing: Balcony Decks Australian Institute of Waterproofing (AIW): External technical drawings 20