EHS SMART-Treat Onsite Moving Media Treatment System

Similar documents
SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

Energy Savings Through Denitrification

SBR PROCESS FOR WASTEWATER TREATMENT

ISAM INTEGRATED SURGE ANOXIC MIX

SBR FOR LOW FLOW APPLICATIONS

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

BIOLOGICAL WASTEWATER BASICS

Making Your Plant Denitrify

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

RE: Annual Report 2016 Wardsville Wastewater Treatment Plant and Collection System

Secondary Treatment Process Control

Presentation Outline

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

3 8 COLIFORM BACTERIA AS INDICATOR ORGANISMS Laboratory tests for disease-producing bacteria, viruses, and protozoa are difficult to perform

General Information on Nitrogen

Troubleshooting Activated Sludge Processes. PNCWA - Southeast Idaho Operators Section Pocatello, ID February 11, 2016 Jim Goodley, P.E.

MUNICIPALITY OF WEST ELGIN RODNEY WASTEWATER TREATMENT PLANT

The difference in unit processes for a traditional on-lot wastewater treatment system compared to the AdvanTex Treatment System

Duffin Creek Water Pollution Control Plant Technical Information

CORPORATION THE EXPERIENCED LEADER IN SEQUENCING BATCH REACTOR TECHNOLOGY

EnviroServer Extended Storage Owners Manual

Module 17: The Activated Sludge Process - Part III Answer Key

The EHS SMART-Treat On Site Wastewater Treatment System Site Location & Installation Manual

Aqua MSBR MODIFIED SEQUENCING BATCH REACTOR

Advanced Wastewater Treatment and Disposal Systems. Wastewater Utility Operation and Management for Small Communities

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

ISAM SBR with Blower Assisted Jet Aeration Design Calculations For Lyons, CO WWTP Upgrade

/ Marley MARPAK Modular Biomedia /

MUNICIPALITY OF WEST ELGIN WEST LORNE WASTEWATER TREATMENT PLANT

CTB3365x Introduction to Water Treatment

American Water College 2010

TREATMENT OF HIGH SULFITE REFINERY WASTEWATER BY CONVENTIONAL ACTIVATED SLUDGE

Wastewater Treatment. Where does wastewater go when it leaves your house?

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota

WASTEWATER 101 Fo r MOWA

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

Biological Nutrient Removal Operations. December 9 th, 2015 Presenter Georgine Grissop PE, BCEE

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia.

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY. Create Optimal Habitats

Feel free to contact me should you require any additional information regarding the report. I can be reached at

Compact Waste Water Treatment MBR /MBBR Technology

MARPAK modular biomedia WASTEWATER TREATMENT

Operation & Maintenance of Onsite Treatment Units Presented by Ronald R. Thomas, Licensed Alternative Onsite System Operator

RYKI WASTEWATER TREATMENT PLANT FIRST NEREDA IN POLAND Authors: Joana Doutor, Janusz Sławiński and Bart de Bruin

BIO-BATCH TM. Sequencing Batch Reactor (SBR) Water & Wastewater Treatment

CORPORATION THE EXPERIENCED LEADER IN SEQUENCING BATCH REACTOR TECHNOLOGY

February 16, Ministry of the Environment Southwestern Region 733 Exeter Road London, Ontario N6E 1L3. Attn.: Mr. Tom Clubb

REMOTELY MONITORED AND E-CONNECTED ADVANCED ON-SITE WASTEWATER TREATMENT NETWORK

Department of Environmental Quality

Packaged Wastewater Treatment Systems for Individual Homes and Small Communities. Mark Gross Orenco Systems, Inc. Sutherlin, OR USA.

WASTEWATER TREATMENT. Nelson Environmental Inc. Nelson Environmental Inc.

Upgrading Lagoons to Remove Ammonia, Nitrogen, and Phosphorus *nutrient removal in cold-climate lagoon systems

Demonstration of IFAS Technology for Cold Temperature Nitrification in Lagoon WWTFs at Clare and Ludington, Michigan

ENHANCED TECHNICAL ASSISTANCE EVALUATION

NITROGEN REMOVAL GUIDE FOR WASTEWATER OPERATORS THE WATER PLANET COMPANY FORMS OF NITROGEN OF INTEREST TO WASTEWATER OPERATORS

2017 Annual Performance Report

DRIP EMITTER SYSTEM STUDY GUIDE

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

Dundalk Wastewater Treatment Plant

Improving Septic Tank Performance by Enhancing Anaerobic Digestion NOWRA Onsite Wastewater Mega-Conference

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Turbo4bio System For the Treatment of Sewage & Organic Effluents

Fixed-Film Processes

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements

BRACEBRIDGE WASTEWATER TREATMENT 2016 SUMMARY REPORT

TREATMENT OF HOSPITAL WASTEWATER USING ACTIVATED SLUDGE COMBINED WITH BIOLOGICAL CONTACTOR

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system

Sludge recycling (optional) Figure Aerobic lagoon

Waste water treatment

COMBI-TREAT IMPROVED SBR TECHNOLOGY. 2.1Process Diagram:

Global Leaders in Biological Wastewater Treatment

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Sanitary and Environmental Engineering I (4 th Year Civil)

THE DEMON ANAMMOX PROCESS: RESOURCE SAVINGS THROUGH SIDE STREAM TREATMENT, AND THE STEPS TOWARDS AN ENERGY NEUTRAL WWTP PRESENTED AT: NC AWWA-WEA 97

orld water works Clean Water and Energy from Wastewater IDEAL MBBR IDEAL IFAS

ONSITE TREATMENT. Amphidrome

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

SLUDGE SETTLEABILITY CONTROL AT ELANORA WWTP RAS CHLORINATION TRIAL. Martin Hindmarsh. Allconnex Water

Wastewater Nitrogen Characteristics, Treatment and Removal Options. Bob Smith, Orenco Systems, Inc. GEC 2013

WASTEWATER TREATMENT SYSTEM

Activated Sludge Base Notes: for student. Activated Sludge Intro. What is Activated Sludge? 3/12/2012

A Battle to Be the Best: A Comparison of Two Powerful Sidestream Treatment Technologies: Post Aerobic Digestion and Anammox

Performance Evaluation of the Moores Creek Advanced Water Resource Recovery Facility

The following biological nutrient removal processes were evaluated in detail in the 2016 Liquid Processing Facilities Plan:

Case Study. Biological Help for the Human Race. BiOWiSH Aqua Improves Nutrient Removal in a Wastewater Treatment Plant - Oberon, Australia

FEASIBILITY REPORT OF 250 KLD SEWAGE TREATMENT PLANT

BIOSPHERE MOVING BED BIOLOGICAL SYSTEMS

Dundalk Wastewater Treatment Plant

Anderson Water Pollution Control Plant

Lagoons Operation and Management in New Brunswick

Wastewater Terms for Permit Applications

Gulf Coast Testing, LLC

Transcription:

EHS SMART-Treat Onsite Moving Media Treatment System Sampling &Testing Protocol for SMART-Treat Wastewater Treatment System SAMPLING DURING OPERATION OF THE TREATMENT SYSTEM-IF DESIRED Sampling and analytical routines may be desired in certain situations. During this time, at minimum, daily system checks are recommended. Daily system check of blowers and pumps, Daily readings of dissolved oxygen, temperature, flow, ph are recommended, Collect necessary samples from the treatment process and perform analytical testing Log in computer manual readings and analytical data The overall goal of the treatment process is to provide aerobic removal of soluble organics and in some cases ammonia reduction (nitrification) or partial TN removal. Heterotrophic and autotrophic microorganisms will preferentially grow on the protected surfaces of the BWT-X biofilm carrier and provide desired pollutant removal. There are a number of factors that influence SMART-Treat Onsite design including but not limited to: Organic Load Dissolved oxygen concentration Nutrient Concentration Inhibitory or toxic compounds ph & Alkalinity Temperature Organic Load The organic load is the food source for the microorganisms. Without enough organic load the microorganisms will starve and scavenger type microorganisms will proliferate. The microorganisms will not be removing the wastewater pollutants and there will be a reduction in removal efficiencies. At the opposite end of the spectrum too much food will also create problems for the treatment process, as carryover of organic load to the nitrification reactors will promote growth of heterotrophs (oxidizers of organics) rather than autotrophs (nitrifiers). Dissolved Oxygen The dissolved oxygen (DO) concentration is very important for the microorganisms. Without the necessary DO, the amount of organic removal and nitrification will be diminished. The aeration system is designed to provide residual DO concentration of 3.0 mg/l in the BOD reduction reactor 2.0 mg/l in the nitrification reactor (if a multi-stage system) at maximum allowable summer water temperature (35C). Heterotrophic biomass requires positive DO concentrations of 2.0 mg/l to optimize substrate removal. Temperature of the wastewater affects the amount of air required to maintain a certain DO concentration, the cooler the wastewater temperature, the more oxygen can be dissolved per unit volume of air diffused into water and vice versa the warmer the wastewater the less oxygen can be dissolved in water per unit volume of air. The amount of air sent to the biofilm reactor

can be varied by 1) the number of blowers operating at a time or 2) by sequencing the blower ON time and OFF time (for example, 2 hrs ON, 2 hrs OFF) with maximum off time of 2 hours. With the exception of dissolved oxygen entering an anoxic zone and residual DO within the anoxic zone, a DO concentration above the design point is not a problem. Nutrient Concentration The microorganisms require certain nutrients for health cellular function. The ideal carbon to nitrogen to phosphorus ratio has been found to be 100:4:1 (C: N: P). With reduced nutrient concentrations in the wastewater there will be a reduction in removal efficiencies. Inhibitory or Toxic Compounds There are a number of natural and man-made compounds that can be toxic to the microorganisms such as high concentrations of sulfur, chlorine, or ammonia. Additionally cleaning chemicals such as quaternary ammonia has been shown to have negative impacts to municipal wastewater treatment plants. If during a normal plant operating day, there appears to be a major die off or sloughing of biofilm is found it is possible a toxic slug has been sent to the treatment plant and additional analytical testing should be conducted to determine the root cause. ph & Alkalinity The best performance will likely be observed when the operating ph within the biofilm reactor is between 6 and 8 s.u. However, numerous systems operate with influent ph between 4 and 6, while the biomass, assimilated to the wastewater, buffers the reactor s ph to neutral. Temperature Like all biological creatures, (bacteria to humans), as the temperature decreases the rate at which something is performed also decreases. Below is a graph of the growth rate of mesophilic bacteria with respect to temperature. As can be seen, the growth rate between the temperature of 10 and 20 nearly doubles (0.45 to 0.9). The optimum operating temperature lies between 30 and 35 o C. Growth 3,0 2,0 1,0 0 0 10 20 30 40 C Temp. FIGURE 1 - GROWTH RATE CHART OF MESOPHILIC BACTERIA

Alkalinity Dosing Influent alkalinity is unknown for most applications. In high strength waste reduction applications alkalinity is usually not an issue. Alkalinity may become an issue in ammonia reduction or Total Nitrogen reduction cases. The amount of alkalinity recovered by denitrification is 2.57 kg/d per kg NOx reduced. A target minimum of 35 mg/l residual alkalinity is the goal. Therefore, in some situations, supplemental alkalinity dosing may be required. If supplemental alkalinity is needed to achieve effluent goals, chemical dosing requirements will be reviewed/determined in final engineering. Sludge Removal The biological process will generate solids through cellular growth and solids found in the wastewater. The smart-treat treatment system contains an integral clarifier that will allow the solids to settle to the bottom of the clarifier tank and be removed automatically on a timed dose or continuous basis--to storage for ultimate disposal. Sampling and Analytical Routines Laboratory analytical methods shall be in accordance with the latest published version of Standard Methods for Water & Wastewater analysis. EHS has the right to substitute onsite field methods for process control purposes. Inlet, outlet, and unit process sampling routines should reflect the minimum schedule required by permit, when permit requires sampling and analysis. At any time plants assembled by EHS are tested for performance, it is imperative that samples are collected properly and analyzed correctly by appropriate methods so that the results provide accurate representation of the performance of our plants. Anything short of that can result in misleading results and unnecessary or ineffective process changes. All representatives of SMART-Treat Onsite Moving Media process will use the following protocol when sampling SMART-Treat Wastewater Treatment Systems. I. Sampling Equipment A. It is required that equipment designed for proper sampling be used. All samples should be collected in sample bottles provided by a certified laboratory. A means to collect samples where the sampling point is difficult to reach shall be provided, i.e. a pole with a sampling container attached, a clean tube with bottom valve or plug, etc. B. Each sample will require at least 3 labeled sample bottles. 1. Samples collected for TKN and ammonia concentrations require a preservative and should have the preservative put in the bottles by the laboratory. 2. Samples collected for NO3 and NO2 will have one bottle. 3. Samples collected for BOD and TSS will have one bottle. 4. Samples collected for ph may require another bottle. C. Dissolved oxygen and ph meters that are calibrated at the site by a trained individual and a thermometer will be provided. D. A sludge measurement device, such as a "Sludge Judge". E. A logbook to record ph, DO and temperature will be provided. Sample time, flow conditions, sampler s name and a verbal description of the effluent indicating the relative amount of solids, the clarity, and any color or odor, detected will also be

recorded. F. A cooler stocked with wet ice will be provided every day that samples are to be collected. G. A chain of custody sheet to be completed by the sampler. H. A brush will be provided to facilitate cleaning of the effluent discharge pipe in preparation for the collection of effluent samples. I. A garden hose with a back-flow preventer attached to the end hooked to the home. This will be used for inducing hydraulic flow for sampling in situations where there is not a free flowing effluent at the time of collection. The hose should be inserted into the wastewater system far enough upstream of the treatment system to induce the flow through the system, but not affect the sample collected in any way. The preventer is necessary to protect the water supply of the home from possible contamination. An apparatus should be supplied that would help hold the hose up out of the sewage when possible. J. Antibacterial soap and distilled water will also be provided for cleaning of collection equipment. K. Latex gloves and eye protection will be provided. II. Sampling techniques Sampling locations The purpose of sampling is to determine the influent quality of the aerobic treatment unit, and to determine the quality of treated water going to surface or subsurface discharge. Raw and final samples are important also, however, the protocol below is for unit process sampling. Sample Location 1: Influent to aerobic treatment unit For Onsite wastewater treatment systems, primary solids removal is typically a septic or trash tank. For other systems, primary treatment may be a primary clarifier or screening device. A. A grab sample must be taken from a free flowing effluent pipe coming from the septic tank or primary solids removal device. The pipe will most likely be located at the outlet end of the septic tank or other solids removal device upstream from the treatment unit. It is very important that the pipe be cleaned (see D). B. If flow is not present, connect the garden hose to an outdoor faucet. The hose should be inserted into the wastewater system far enough upstream of the treatment system to induce the flow through the system, but not affect the sample collected in any way. For most commercial or residential units this would be in the inlet to the septic tank. For this location, the hose should be placed in the inlet tee to best simulate influent into the septic tank. The hose should not be allowed to run at this location longer than 10 minutes. C. Put on protective eye wear and latex gloves. D. To the extent possible, use the brush to clean the discharge pipe of attached growth that may dislodge during the process of collecting Rinse the pipe with the garden hose. (Note: If the pipe is not accessible for cleaning in this manner the sampler must be mindful not to touch the pipe when sampling to avoid knocking loose large solids that could contaminate the sample.)

E. Place the end of the garden hose in position to add water to the first compartment of the septic tank or other solids removal device (See step B) DO not add water to the moving media aerated reactor chamber. Take care to not touch the sewage with the end of the hose. Turn the faucet on. F. After the effluent has been flowing out of the pipe for a minimum of 10 minutes, place the collection container into the stream of effluent at the outlet of the solids removal device (septic tank effluent baffle or tee) and rinse any collection containers (including sample bottles) that will contain effluent. DO NOT rinse TKN and ammonia sample bottles that contain a preservative.

Sample Location 2: Highly Pretreated Effluent sample: The sample location will most likely be located in a distribution box or pump chamber down stream from the biosolids clarifier and treatment unit. It is very important that the pipe be cleaned (see D) if taking a sample in a free-flowing pipe. If there is a pump chamber and water is in the pump chamber, this is a good place to take a sample---if it reflects aeration chamber quality. G. If a sample cannot be taken from a pump chamber, then the operator must determine if the contents of the settling chamber directly downstream of the aeration reactor are representative of the effluent. The first evaluation of whether this sample will be representative will be to determine if there are substantial settable solids in the biosolids clarifier or the pump chamber. A sludge measurement device should be used to determine if there are substantial settled solids in the bottom of the settling chamber more commonly referred to as the biosolids clarifier. If there are a substantial amount of solids (more than 10-12 ), the sample may not be representative of the effluent produced by the aeration device. In that event, the biosolids clarifier or pump chamber should be cleaned out and pump be checked for proper operation. A test for evaluation of the biosolids clarifier or pump chamber will be to measure the dissolved oxygen in the biosolids clarifier and/or pump chamber. The dissolved oxygen in this chamber must be above 1.0 mg/l for the sample to be representative of an aerobic effluent. If the dissolved oxygen is below 1.0 mg/l, then the biosolids clarifier or pump chamber should not be used for sampling. Another test for evaluation of the biosolids clarifier or pump chamber will be to collect a sample from the biosolids clarifier or pump chamber and compare it to a sample from the reaction chamber. Samples collected from a biosolids clarifier or pump chamber should be taken from six inches to a foot below the surface. This will help to eliminate any floatable solids from affecting the sample. This sample should be compared to a sample collected at the effluent side of the aeration chamber. This sample should be allowed to settle for 5 minutes and then compared to the sample from the biosolids clarifier or pump chamber. If the clarity of the two samples is similar, then it can be assumed that the samples are similar. If the biosolids clarifier or pump chamber sample is cloudy or obviously darker than the settled aeration sample, then the biosolids clarifier or pump chamber sample should not be used as a representative sample. If the sample can not be collected from the pump chamber --1 st choice, or biosolids clarifier---2 nd choice, then a sample should be collected from the outlet end of the aeration chamber. This sample should be allowed to settle for 5 minutes, the clear liquid portion decanted to a clean sample bottle and this information should be noted in the log as well as the other observations used to collect this sample.

H. Take the sample for ph and temperature and test for those parameters immediately. When finished with this sample discard it back into the system and rinse it several times with water. I. Take the DO reading inside the reaction chamber and outside the unit in the anoxic zone of the tank. J. Record the ph, DO and temperature in the logbook along with the date address and time. K. Take the sample bottles and place them into the cooler with the wet ice. The bottles should be well covered by the ice in order to facilitate faster cooling. L. Clean the sampling containers with antibacterial soap and water and rinse them with distilled water before collecting another sample. M. Fill out the chain of custody sheet with correct sample ID numbers and all other required information and/or pertinent comments. Be sure and sign this sheet and observe the laboratory personnel signing it when you deliver a sample. The samples should be delivered the same day it is collected. If necessary arrangements should be made to deliver the samples after normal business hours.