SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

INSTALLATION GUIDELINES

EVOH PENETRATIONS INSTALLATION GUIDELINES PERMINATOR PLACEMENT

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES - With VaporSeal Tape

Installation. Guide. Installation. Foundation Preparation

WATERPROOFING. MiraPLY Installation Instructions SCIENCE. SERVICE. SOLUTIONS. Introduction. Description. Substrate Preparation. Features and Benefits

B-1 DIRECT WATERPROOFING APPLICATION TO LAGGING FOLD OVER ARMORCLAY 1000 FOR GRADE LINE TERMINATION VERTICAL GEO-MAT C DRAIN 110 OR 150 FASTENERS

Start the installation at one corner of the building. Unroll the first sheet of MiraPLY-H square/parallel to the building wall, starting at one corner

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

Student Services & Classroom Addition

STEGO WRAP 15-MIL. 15 mil. A true VAPOR BARRIER ASTM E 1745 Class A-B-C Compliant WRAP STEGO VAPOR BARRIER THE STEGO ADVANTAGES FEATURES & BENEFITS

PLATON FOUNDATION WRAP

STEGO WRAP CLASS C VAPOR RETARDER A STEGO INDUSTRIES, LLC INNOVATION VAPOR RETARDERS , VERSION: JAN 5, 2018

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Installation Manual. Foundations. Version 4.3ᵠ

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

CCW MiraPLY Installation Instructions

Vapor Retarders ,

Installation Manual. Foundations. Version 2

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

G October 2018

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Section Pre-Applied Sheet Membrane Waterproofing

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

STEGO WRAP 20-MIL VAPOUR BARRIER A STEGO INDUSTRIES, LLC INNOVATION VAPOUR RETARDERS , VERSION: 20 JUL 2018

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

UNDERSLAB OPTION

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Radon Control Methods for Existing and New Residential Structures

GABIONS AND REVET MATTRESSES

6.5 oz/yd g/m 2. 35/35 lb f min. 155/155 N min. 1.5% max. each direction Adhesion - Heat Sealed Seam ASTM D751, Dielectric Weld

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

G October 2018

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

WATERPROOFING. MiraPLY -V with SeamLOCK Technology SCIENCE. SERVICE. SOLUTIONS. Standards. Description. Typical Properties.

STEGO WRAP VAPOR BARRIER

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

STORMCAPTURE. Installation Manual

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

STEGO WRAP VAPOR BARRIER ASTM E1745 Class A-B-C Compliant

SECTION MECHANICALLY STABILIZED EARTHEN SLOPES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Pre-applied waterproofing

WATERPROOFING. MiraPLYTM. -H with SeamLOCKSM. Technology SCIENCE. SERVICE. SOLUTIONS. Description. Typical Properties.

SYSTEM 500 NEWTON. System 400 NEWTON 403 HYDROBOND Externally Applied Waterproofing Membrane DATA SHEET MSDS INSTALLATION MANUAL

379 Quick Installation Guide

SRP-AirOutshield UV Issued:

HUITEX GEOCELL INSTALLATION MANUAL

PRODUCT DATA SHEET. SikaProof A

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

Installation Information 2016

Gas Protection System Components

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

SECTION SELF-ADHERING SHEET FLASHING

INSTALLATION GUIDELINES PRECON

SECTION TERMITE AND PEST CONTROL AT ABOVE GRADE PLUMBING PENETRATIONS AND BATH TRAPS

STEGO WRAP VAPOUR BARRIER ASTM E1745 CLASS A-B-C COMPLIANT

TOTAL FLOW Soil Sheet Drain

FOUNDATIONS AND BASEMENTS

Chapter 2: Foundation

PROTECTOWALL DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 517 [2013]

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

PREPRUFE 300R LT & 160R LT

RETAINING WALL. How to Waterproof Block Walls MATERIALS:

BUILDING ENVELOPE PRODUCTS PROVIDING A FULL BUILDING ENVELOPE SYSTEM. Control Moisture Movement with Our Patented Technology

DuPont Tyvek Wall Underlay Install Guide

BENTONITE WATERPROOFING

AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications

Installation Guidelines for DENDRO-SCOTT Root Barrier

Pre-applied waterproofing membranes that bond integrally to poured concrete for use below slabs or behind basement walls on confined sites

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

ADEKA ULTRA SEAL KBA-1510FP

1.02 RELATED WORK: Refer to the following sections for related work:

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

PREPRUFE Plus Low Temperature Membranes

INSTALLATION INSTRUCTIONS

3M Canada Air Barriers Section Master Guide Specification Page 1 April 2012

Construction Standards PAGE

3M Canada Weather Barriers Section Master Guide Specification Page 1 April 2012

WeatherSmart Air Barrier Installation Guide

S Y S T E M S FOAM IN WATERPROOFING. Whether used as a drainage board, underslab

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

Addendum to Specifications

SECTION SPECIFICATION FOR MECHANICALLY STABILIZED EARTH TWO STAGE WALL SYSTEM

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

STEGO WRAP VAPOUR BARRIER ASTM E1745 CLASS A-B-C COMPLIANT

PRODUCT DATA SHEET SikaProof A

Transcription:

Installation Guidelines VBC Products

Composite STEP 1A: Ground Surface Preparation Earth Base Select the suitable product (VBC-350, 31 mil) and ensure the installation surface is relatively smooth. Barrier-Bac should be unrolled to completely cover the pour area. When install, the geotextile has to be placed facing up. STEP 1B: Ground Surface Preparation Aggregate Base Although Barrier-Bac products are extremely tough, installation is easier and more effective when done over a smooth base. It is optional to have a layer of granular fill under the Barrier-Bac. When install, the geotextile has to be placed facing up. Select granular fill (optional) VB Installation Guidelines 33

Composite STEP 2: Unroll, Overlap And Tape The Seam Please place the geo-textile (black color) side facing up. Seams and/or joints can be joined using Barrier-Bac Double-Sided Termination Tape. Two VBC-350 sheets should be overlapped six inches side-to-side and end-to-end. Using Double-Sided Termination Tape to seal seams provides VBC-350 with 100% peel adhesion strength against concrete. Note: In case project design specifications require or it is needed to use additional adhesive to secure Barrier-Bac Seam Tape, we recommend using 3M Scotch-Weld HoldFast 70 Cylinder Spray Adhesive Clear to apply on the geo-textile surface overlap prior to tape application. 2 Barrier-Bac Double Sided Termination Tape 6 STEP 3: Pour The Concrete Inspect all seams, penetration and damaged areas and make sure they are well sealed or patched. (See Step 7 & 8: Seal Penetrations and Step 9: Patch Damage) After seal all penetrations and patch all damaged areas, pour the concrete on top of Barrier-Bac Concrete floor slab Construction / Isolation joint Steel (mesh, grid, or rod) reinforcement Barrier-Bac Double Sided Termination Tape VB Installation Guidelines 34

Composite STEP 4: Pipe Penetration Details See the details about making pipe boots at Step 7: Seal Penetrations. For square penetrations, see Step 8: Square Penetrations Concrete floor slab Construction / Isolation joint Barrier-Bac Double Sided Termination Tape Pipe Boot STEP 5: On Top of The Footing When vertical wall is involved, please place the membrane butt end on top of the footing and up against the vertical wall. This placement method will provide the needed protection from outside moisture following construction completion. * Place the membrane butt end on top of the footing and up against the vertical wall. Poured Concrete Wall Waterstops Aggregate Drainage system Footing Subgrade VB Installation Guidelines 35

Composite STEP 6: Seal Penetrations Round Penetrations With Pipe Boot All penetrations must be sealed with the and Seam Tape. For round pipe or posts, please seal penetrations with Pipe Boot. Measure a piece of 18 inches in width and twice (two times) the circumference of the pipe. 18 2 times pipe circumference Roll the measured piece of membrane in a roll form approximately the size of pipe. Flatten sized roll and make vertical cuts to approximately one-third of the width and two inches apart. one third of width 2 Open boot and wrap snugly around pipe, spreading cuts around base so strips lay horizontal to base. Tape around pipe circumference at top of boot, down side seam of boot and all two inch horizontal strips. Cover all seams of membrane with seaming tape. tape VB Installation Guidelines 36

Composite STEP 7: Seal Penetrations Square Penetrations With Block Out All penetrations must be sealed with the and Seam Tape. For square posts, please seal penetrations with Block Out Seaming Methods. Cut a piece of twice the height and one and one-half the length of the perimeter of the Block Out. Wrap membrane around Block Out and temporarily tape vertical seam. cut corners approximately half the height of block out tape vertical seam block out Make cuts in each of the four corners approximately half the height of the Block Out. Remove formed Block Out membrane form, flip over and replace on Block Out spreading flaps to horizontal position. Tape all flaps securely with Barrier-Bac Seam Tape. tape STEP 8: Patch Damages All damages to the film must be sealed prior to pouring. Patch all damaged areas with and Seam Tape. Membrane patch 8 Cut a piece of Vapor Retarder in a square large enough so sides of patch extend eight inches from side of puncture. 8 Puncture in membrane Membrane patch Cover damaged portion with membrane patch and secure all patch seams with Barrier-Bac Seam Tape. Seaming tape VB Installation Guidelines 37