Air Transfer Silencer

Similar documents
ORTO. Sound-attenuating transfer unit QUICK FACTS

SDW. Supply air diffuser for wall mounting in small premises QUICK FACTS

CGV/RGV. Sound attenuating transfer units

CDH/CLH. CleanZone Ceiling diffuser with micro-filter for supply air in clean rooms QUICK FACTS

ALS 25 db(a) 30 db(a) 35 db(a) Size

EIV. Circular single deflection grille for walls. Quick facts. Quick guide EIV A I R F L O W - S O U N D L E V E L

AQLV - Acoustic Louvres. Complete Ventilation Solutions. Telephone:

Transfer Air Device Type LDO-T

Rectangular sound attenuator

KOMBI PVA KOMBI PVA 1 CC

OS-ALD ACOUSTIC LOUVERS

FACILE. Hygienic sound attenuator for rectangular ducts QUICK FACTS

Test Report No. 100/12

DPG. Low velocity terminal for small airflows QUICK FACTS

Acoustic Louvres. Product and Technical Data

LARGO. Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS

NEW. FR90 fire dampers. Maintenance-free

White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound

LENTO. Angle sound attenuator for rectangular ducts QUICK FACTS

ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES

5045 Orbitor Dr., Building 8, Suite 200, Mississauga, ON L4W 4Y4 Phone: (905)

Melhart Music Center Modular Music Practice Rooms - E3 Ready Specifications Section 13034

MORENDO. Rectangular sound attenuator with low installation height and tapered acoustic baffle surfaces

SIDERISE SC cavity barriers & fire stops for suspended ceilings

CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 June 2017 U-VALUE IMPROVED BY 22 % AIRCOOL VENTILATORS ...

Sound insulating doors

Fire protection, soundproofing and thermal insulation

Acoustic Louvers A Complete Range of Certified, High-Performance Acoustic Louvers to Solve Diverse Environmental Noise Pollution Problems

TLRD. Thin Line Return Dissipater

Plastic Access Panels

AIRCOOL VENTILATORS FURTHER INFORMATION

Acoustic Louvers A Complete Range of Certified, High-Performance Acoustic Louvers to Solve Diverse Environmental Noise Pollution Problems

Measurement of Sound Absorption Coefficient for Perfopan slotted Wall Panels Code No. SLT 7x7-PR 12%, DS 270, on 45 mm mineral wool

CLA. Compact sound attenuator for circular ducts QUICK FACTS

Acoustic Louvers ABSORPTIVE ACOUSTIC LOUVERS

LindabPlexus. Supply air beam. lindab we simplify construction

CLA. Compact sound attenuator for circular ducts

SILENT SCREEN ACOUSTIC LOUVRE SYSTEM

FLEXIBLE DUCT FLEXIBLE DUCT FLEXIBLE DUCT

SORDO. General. Sound attenuator for circular ducts

Fire damper BSK-RB Contents Description...3 Models and dimensions...4 Installation...8 Technical data... 12

Accutone2 Architectural Enclosures

Hudson Series 200 Acoustic Louvre

Edition October May (always refer to the latest manual as set out on

Hudson Series 300 Acoustic Louvre

SORDO. Sound attenuator for circular ducts QUICK FACTS

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

IAC Acoustics Moduline Noise Control Enclosures. Mark Simnick

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

Computer Room Floor Grille

SIGARTH AB OUR SOLUTIONS MAKE THE WORLD MORE SECURE YOU CAN RELY ON US A MARKET LEADER IN THE HVAC

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

Cooling and heating systems. Contact cooling ceiling system KKS-4/GK for gypsum board ceilings

NV series. Induction VAV air volume control terminals

lindab we simplify construction Product overview Acoustic solutions

CHILLED BEAM IQ STAR STELLA TECHNICAL CATALOGUE

ACOUSTIC LOUVERS...a perfect partner in performance ...a perfect partner in performance

lindab we simplify construction Product overview Acoustic solutions

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

S T R E T C H M E T A L

Sales and Marketing :

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif

Declaration of Performance (DOP)

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 A METHODOLOGY TO MEASURE THE ACOUSTIC PERFORMANCE OF ACCESS FLOORS

lindab we simplify construction LindabAbsolute Filtration Product overview Absolute Filtration

KS EXTENSIONS FOR CLEAN ROOMS

LTG Air Diffusers. Product Overview. Outstanding technique for highest demands. Unique in comfort, acoustics and design.

LDI Industrial diffuser

Creating a World of Possibilities

lindab we simplify construction LindabIndoorClimateSolutions Product overview Acoustics

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

L I N E A R M U L T I - P A N E L S Y S T E M

Comparison of measured and predicted sound insulation for a thermal retrofitted building

Acoustic Performance

ARH-1. Hung ceilings, because of the TRANSMITTED NOISE & VIBRATION BARRIER FOR SUSPENDED CEILINGS, DUCTWORK, CONDUIT, PIPING, ETC.

Communal 51 Ceiling Systems by Vogl

XLnt Panels. Super-size your ceiling

Effect of implementation quadruple glazing panel into the walls on the airborne sound insulation of building facades

lindab we simplify construction Lindab Ventilation More than ducting

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

Look ~ do you see the noise leaking through that ceiling?

REPORT SUNDBYBERG KOMMUNHUS, EVALUATION OF OPEN PLAN OFFICES ACC. TO ISO

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 March 2018 U-VALUE IMPROVED BY 22 % AIRCOOL VENTILATORS HYBRID PLUS2 AIRCOOL NEW ...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

Stretch Metal. Striking visual effects

Determination of the sound reduction and sound absorption of a railroad noise barrier

Product Overview. LTG Air Diffusers. Outstanding technique for highest demands. Unique in comfort, acoustics and design. LTG Aktiengesellschaft 1

MANUFACTURING WITH INNOVATION In the UK since. Continuous Line Acoustic Louvres. caice.co.uk

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

the constant partition A partition made-to-measure, adjustable with an accurary to within one millimetre to any building grid.

DICTATOR Lift Shaft System

Product Information Sheet

Temporary Noise Control Barrier... Page 2. Noise Reduction Damping Pad Page 4. Permanent Noise Control Barrier. Page 5

Report. Robert-Bosch-Str Münster Germany. Report number: A E. Date: 14 February TS/YW/LvI/A E-RA

Transcription:

Air Transfer Silencer Experts on indoor climate in low-energy houses

Unique Air Transfer Silencer Area of use REC s air transfer silencer has a complete solution which meets all acoustic requirements - when there is a demand for high sound attenuation. comprises a silencer and - for this purpose specifically developed an air transfer grill for acoustic inner ceilings. meets crosstalk requirements in the air in all buildings that have up to sound class A. The duct transfer unit has been developed to provide very good sound attenuation with low pressure drop combined with high mounting flexibility, the air transfer unit offers a very good air flow because of the high free area on the grill unit. REC s ensures that you keep the wall requirements for high sound attenuation. does not affect the total wall R w and a reduction calculation is therefore not needed. Can be used in schools, offices, hospitals, medical reception rooms, interrogation rooms, public toilets, laundry rooms and other areas where the wall has sound requirements. Design consists of REC s flexible AKU-COMP A silencer and our acoustic suspended ceiling transfer grill. Thanks to the silencer s flexible construction, there are several installation possibilities. The unique design of our makes it very suitable for installation in suspended ceilings. is available in two different versions: TT - Ceiling / Ceiling = 1 AKU-COMP A 1,2 m 1 AKU-COMP A 0,6 m 2 mounting frames with lock washers 2 grilles for suspended ceilings TV - Ceiling / Wall = 1 AKU-COMP A 1,2 m 1 mounting frame with lock washer 1 grilles for suspended ceilings with lock washer 1 wall diffuser 2 REC Indovent Material: Aluminum /steel sheet Finish: White powder coated steel sheet (RAL 9016) meets the requirements for non-combustible material, Euro Class A1 according to standard EN 13501-1. It also meets the requirements for air tightness class D. Corrosivity = C2 Air flow Up to 50 l/s Dimension Ø125 mm. Standard length The AKU-COMP silencer is flexible and comes compressed but should be extended to its full length for best sound attenuation. 0.25 m extendable to 0.6 m. 0.55 m extendable to 1.2 m. Maximum operating temperature +80 C. Care Clean the transfer grilles when necessary, using lukewarm water and a detergent. When ordering, please state Air Transfer Silencer - TV - 125 Product TT / TV Dimension

Sound-transmission class is a complete air transfer solution with high total sound reduction measured according to ISO 1:717, 1:140. is suited for mounting in suspended ceilings. Ensures the premises sound class A, B, C or D in accordance with SS-EN 025267. Below you find the reduction values R, L w and R w the value for refers to 1 m 2 transmission area. TT (Ceiling / Ceiling) Ø125 mm Attenuation mid frequency (Octave band) Hz Sound power L w R w /1 m 2 Hz 63 125 250 500 1000 2000 4000 8000 65 Lw 2,6 32,4 26,5 47 49,7 49,8 48,9 33,1 R mid frequency (Octave band) Hz R 21,8 51,5 45,7 66,1 68,8 68,9 68 52,2 TV (Ceiling / Wall) Ø125 mm Attenuation mid frequency (Octave band) Hz Sound power L w R w /1 m 2 Hz 63 125 250 500 1000 2000 4000 8000 56 Lw 10 19 32 27 43 39 51 33 R mid frequency (Octave band) Hz R 29 38 51 46 62 58 70 52 If the units are installed in a concrete wall or a wall penetration pipe of steel/plastic is used, R and R w attenuation drop by 8-12. REC Indovent 3

Dimensioning Ø125 mm L/s 60 50 40 30 20 10 0 Recommended dimensioning area 0 1 3 5 10 12,5 15 Pa At higher flow rates, we recommend several RW60 units Ø125 mm (minimum distance 2 m). R W reduction chart The reduction chart below tells you how much the wall s total R w value decreases after installation of for example an. However, if the given R w for your building element ( ) is higher than the wall R w, there will be no reduction. Generally speaking, the aim is to have as high R w value for all building parts as possible. REC s affects the total wall R w marginally and a reduction calculation is not needed. Y = Difference 50 45 40 35 30 25 20-21 -18-15 -12-9 -6-3 15-1 10 5 0 0 20 40 60 80 100 120 X = m 2 X. Wall surface area in relation to / Area Ø (Reference area 1 m 2 ) Y. Difference R w (Wall) - R w air transfer duct ( ) Generally, the R w sound class of the wall is determined by reducing every wall part element s R w -value like doors, windows, air transfer grilles or other sub-elements from the total R w wall surface. The R w value is obtained by weighting the reduction values received from measuring the noise reduction by one third octave band and the frequencies from 100-3150 Hz to a reference curve according to ISO 1: 717, referring to 1 m 2 transmission area. As you can see from the sound attenuation table on page 3, the sound attenuation is R w 65/1 m 2 for -CC, and R w 56/1 m 2 for -CW. Note the minimum requirement of at least 1 db reduction (EN 12354). When installing more than one air transfer unit, each additional air transfer unit will reduce the R w value as shown in the above table. 4 REC Indovent

Weight and Measures ØD C Ød Size ØD (mm) Ød (mm) C (mm) 125 175 124 36 Aluminium cover Mineral wool Min. height mm Size Min. height (mm) 125 250 Perforated Compact duct Standard lenght: 0,25 m Flexible length to 0,6 m. 0,55 m Flexible length to 1,2 m. AMA text is described as follows in Swedish AMA (AB Svensk Byggtjänst s Guidance for the preparation of particular conditions for Building and Civil Engineering Works and Building Services Contracts ). QMD.1 AIR TRANSFER UNIT, WALL MOUNTED ODXX- X number Manufacturer: REC Indovent AB Type: TV (Ceiling / Wall) TT (Ceiling / Ceiling) Flexible silencer for air transfer between rooms. Negligible impact on the wall s total R w. Meets crosstalk requirements for air transfer in all buildings up to sound class A. TV (Ceiling / Wall) - Sound class R w 65/1 m 2 TT (Ceiling/Ceiling) - Sound class R w 56/1 m 2 Air flow: Up to 50 l/s Pressure drop: Up to 12 Pa Size: Ø125 mm REC Indovent 5

Installing 1 2 3 4 5 6 6 REC Indovent

7 8 9 10 11 12 TV - Ceiling / Wall = 1-12 TT - Ceiling / Ceiling = 1-11 (x2) min. height mm min. height mm Min. height: Ø125 = 250 mm Min. height: Ø125 = 250 mm REC Indovent 7

REC 05/04/2017 16-0013_ENG mediacad.se A member of Svensk Ventilation (REC is a member of this Trade organization) REC Indovent AB reserves the right to make alterations to specification and construction without prior notification. REC Indovent AB P.O. Box 37, SE-431 21 Mölndal, Sweden Visiting address: Kärragatan 2 Tel: +46 31 67 55 00 Fax: +46 31 87 58 45 Certified acc. to ISO 9001/14001 www.rec-indovent.se Experts on indoor climate in low-energy houses