SEDIMENTATION ANALYSIS

Similar documents
Standard Test Procedures Manual

Standard Test Method for Particle-Size Analysis of Soils 1

Institute of Technology of Cambodia

Laboratory 2 Hydrometer Analysis Atterberg Limits Sand Equivalent Test

Effect of hydrometer type on particle size distribution of fine grained soil

Particle Size Distribution Analysis for Ceramic Pot Water filter production

METHOD A6 THE DETERMINATION OF THE GRAIN SIZE DISTRIBUTION IN SOILS BY MEANS OF A HYDROMETER

Math Matters: Dissecting Hydrometer Calculations

Materials Testing and and and and and and and and 2-88

EXPERIMENT 1 SIEVE AND HYDROMETER ANALYSIS (GRAIN SIZE ANALYSIS) (PREPARED BY : AHMAD FAIZAL MANSOR)

CEEN Geotechnical Engineering - Laboratory Session 1 Mechanical Sieve Analysis, Specific Gravity of Solids, Volumetric/Gravimetric Relations

Development Team. Paper No: 5 Water Resources and Management Module 6 : Processing of Hydrometer Data. Environmental Sciences

PRESENTATION OF "GSA"

Laboratory Soil Classification

CE 344 Geotechnical Engineering Sessional-I (Lab Manual)

CEEN Geotechnical Engineering

CEEN Laboratory 1 Mechanical Sieve Analysis Specific Gravity of Soil Solids Gravimetric/Volumetric Relations

Mechanical Analysis of Soil. Mechanical Analysis of Soil. CIVL 1112 Sieve Analysis 1/7. As complex as it is, soil can be described simply.

CE 240 Soil Mechanics & Foundations Lecture 1.3. Soil Particles (Das, Ch. 2)

SOIL PHASE RELATIONSHIPS, INDEX PROPERTIES AND CLASSIFICATION

hydrometer set operating instructions All it takes for environmental research

Name Lab Section Date. Sediment Lab

B Soil Particle Analysis Procedure

LABORATORY 3 SOIL ANALYSIS

WEEK 5 ACTIVITY. Lecture (2 hours)

Standard Test Procedures Manual

CHAPTER 3 CHARACTERIZATION OF MANUFACTURED SAND

CHARACTERIZATION OF CERAMIC SHELLS FABRICATED USING YTTRIA AS REINFORCING FILLER

Sieve Opening, mm Opening, in Soil Type. Cobbles mm 3 in. Gravel mm (2.0 mm) #4 [# 10 for AASHTO) ~0.2 in (~0.

1. Fineness Standard EN describes two methods of determining the fineness of cement: sieving method air permeability method ( Blaine)

3- Highway Materials Aggregates

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

To determine relevant properties of aggregates used in the making of hot mix asphalt (HMA).

BACKGROUND: Porosity permeability. PART I Materials Procedure EMPTY the tube.

TESTS ON AGGREGATES 58

Tex-121-E, Soil-Lime Testing

Soil Mechanics Lab. (LCIV 3151) Experiment No.3: Grain size analysis Part I: Sieve Analysis. Part II: Hydrometer analysis.

Classification of Soils

Soil Mechanics Laboratory Manual

Detailed response to reviewers comments

J. Paul Guyer, P.E., R.A.

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation Revised May Pages LABORATORY TESTING SECTION

Presented by: Civil Engineering Academy

Table 2 : Tabular entry for Specific Gravity Test on Soil

Accredited Laboratory

SOIL CLASSIFICATION BASICS Commonly based on grain size and soil consistency. Several classification systems exist:

ATTERBERG LIMITS. The liquid and plastic limits have been widely used all over the world. Primarily for soil identification and classification.

Accredited Laboratory

EMBANKMENT AND BASE WAQTC FOP AASHTO T 99 / T 180 (18) IN-PLACE DENSITY

DETERMINATION OF PLASTIC LIMIT USING CONE PENETROMETER

Standard Test Procedures Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Soil Stabilization using Plastics and Gypsum

Chapter 2: Geotechnical Properties of Soil

LABORATORY COMPACTION CHARACTERISTICS AND MOISTURE-DENSITY RELATIONSHIP OF SUBGRADE, EMBANKMENT SOILS, AND BACKFILL MATERIAL

Introduction to Geotechnical Engineering, 2e Das/Sivakugan Chapter 2 Grain-Size Analysis Cengage Learning Engineering. All Rights Reserved.

GENERAL EQUIPMENT. 3 Electronic analytical balance (320gr capacity - 0,001gr readability)

[ [GEOTECHNICAL ENGG-1] SOLVED QUESTION PAPER]

Chapter 7. Sand Castle Tests 3

SEDIMENT TRAP PILOT PROJECT: Design and Bench-Testing

4.1 DETERMINATION OF SPECIFIC GRAVITY

Moisture in soils: Types of water in soil sample: University of Baghdad College of Engineering Soil Mechanics Laboratory ( ) 3 rd year

7. The diagram below represents cross sections of equal-size beakers A, B, and C filled with beads.

Introduction to Geotechnical Engineering 2nd Edition Das SOLUTIONS MANUAL

3. Brush adhering grains from the outside of the measure and determine the mass of the cylinder and contents to the nearest 0.1g.

SOIL MECHANICS Assignment #2: Soil Classification Solution.

BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11)

Middle East Technical University Department of Civil Engineering CE Soil Mechanics PROBLEMS

Review For Final Exam. Review For Final Exam

Sieve Analysis. Introduction

INDIAN INSTITUTE OF TECHNOLOGY GANDHINAGAR Department of Civil Engineering Soil Mechanics Laboratory

Most coastal benthic monitoring programs include

Beyond Engineering & Testing, LLC.

PAVETEX Engineering, LLC

TBS/CDC-7 (2903) P2 DRAFT TANZANIA STANDARD. TBS/CDC-7(2903) P2- Sodium silicate for industrial use - Specification (Revision of TZS 219:1984)

GEL Hydrogeology (Groundwater) LAB 2: POROSITY & HYDRAULIC CONDUCTIVITY - Porosity Segment - Grade: /25

Marshal Mix Design. Compacted Specimen Asphalt Content Loose Specimen

JAZAN UNIVERSITY. CIVIL ENGINEERING DEPARTMENT Equipments and Devices of the Concrete Laboratory

Variation of Physical Properties of Cement over Time

METHOD OF TEST FOR FREEZING-AND-THAWING OF COARSE AGGREGATE

CBR of Soaked Clay Drained by Sandy Layer

GeoTesting Express, Inc.

MARSHALL MIX DESIGN PROJECT. [2 nd semester 1433H] CE432-Highway Engineering LABORATORY

DISPERSIVE SOILS. Dispersive soils are those in which the clay content has a high percentage of sodium.

Effects of Curing Conditions on Strength of Lime Stabilized Flyash

HCMTCB SOILS CERTIFICATION KEY ELEMENTS LIST

London Examinations IGCSE

Dan Kwian Clays for Slip Casting

Fines fraction of paper stock by wet screening

A H M 531 The Civil Engineering Center

CHAPTER 6 POLYPROPYLENE FIBRE REINFORCED GEOPOLYMER CONCRETE COMPOSITES

Aggregates for Use In Concrete

DREDGED OFFSHORE SAND AS A REPLACEMENT FOR FINE AGGREGATE IN CONCRETE

Permeability Tests. Geotechnical Engineering, Laboratory 7

Analysis of Sediment Samples for USEPA Region IV: Science and Ecosystem Support Division Fenholloway River

Test specimens from asphalt mixture pavement will be sampled according to AASHTO R 67.

Aggregates for Use In

Tex-113-E, Laboratory Compaction Characteristics and Moisture- Density Relationship of Base Materials

EXPERIMENT 15 FREEZING POINT: A COLLIGATIVE PROPERTY OF SOLUTIONS

APPENDIX I: EROSION TEST RESULTS ON NEW ORLEANS LEVEE SAMPLES

Transcription:

SEDIMENTATION ANALYSIS Lab. Report NO. 5 DEFINITION Sedimentation (hydrometer and pipette) analysis defines the grain size distribution curve of soils that are too fine to be tested with sieves. Sedimentation analysis sorts soil particles by size using the physical process that is described by (Stokes, 1891) when the particles are allowed to settle under gravity. INTRODUCTION The theory of sedimentation is based on the fact that large particles in suspension in a liquid settle more quickly than small particles, assuming that all particles have similar densities and shapes. Although clay particles are far from spherical, the application of Stokes Low based on diameters of equivalent spheres. Sedimentation test can be described by hydrometer analysis or pipette analysis. A dispersing (also deflocculating) agent is used with a soil suspension in water in order to ensure separation of discrete particles of soil. Two materials are often used as dispersal agent to neutralize the soil- particle charges: 1- Sodium hexa-metaphosphate (NaPO 3) known commercially as (Calgon) and for most purposes it has found that Calgon is one of the most suitable and convenient dispersants. 2- Sodium silicate or water glass (Na 2SiO 3). HYDROMETER ANALYSIS DEFINITION Hydrometer test is used to determine the grain size distribution of finegrained soils having particle size smaller than 0.075mm and if more than 10% of the soil passes the No.200 sieve. For soil samples have particle sizes ranging from sand to silt or clay, sieving and sedimentation analysis are combined. 1

Lab. Report NO. 5 INTRODUCTION In many instances, the results of sieve analysis and hydrometer analysis for a given soil are combined on one graph. The hydrometer is usually a type 152H (refer to Fig.1) and is calibrated to read grams of soil that still in suspension of a value of G s=2.65 in1000 cm 3. For soils of other specific gravity a correction must be made. It gives the weight of particles located around the bulb centroid but not of those located above or below. Fig (1) Note that L is the depth measured from the surface of the water to the center of gravity of the hydrometer bulb at which the density of the suspension is measured. It is intended that the specific gravity test be made on that portion of soil which passes the No.10 (2.00mm) sieve, when it is to be used in calculation in hydrometer analysis. CORRECTION OF HYDROMETER READING The hydrometer readings are corrected as: i. Meniscus correction Since the suspension is opaque, the observations are taken at the top of meniscus. The meniscus correction is equal to the reading between the top of the meniscus and the level of the liquid. As the 2

Lab. Report NO. 5 marking on the stem increases downward, the correction is positive and is a constant for a given hydrometer. The meniscus correction is about 0.5 to 1.0 g/l for most 152 H hydrometer. The correction hydrometer reading for meniscus is: R = R a+ meniscus correction Where: R a = the actual reading above meniscus. ii. iii. PURPOSES Temperature correction The hydrometer is calibrated at 20 C. If the temperature of the suspension is different from 20 C, a temperature correction (C T) is required for hydrometer reading. The temperature correction is obtained from the table (6-3). Dispersion agent correction Addition of the dispersing agent to the soil specimen causes increasing in the specific gravity of the suspension. The effect of water impurities and the dispersing agent on hydrometer readings can be obtained by using a control jar from the same source and with the same quantity of dispersing agent (125 cm 3 ) as used in the soil-water suspension to obtain "zero correction". To find the grain size distribution of that fraction of soil, which has diameter smaller than 0.075 mm (Silt and Clay). APPARATUS AND MATERIALS 1. Hydrometer (152 H model preferably). 2. Two sedimentation cylinders of glass or hydrometer jar which is marked for a volume of (1000 ml). 3. Dispersion agent with concentration of 4% of (sodium hexa metaphosphate), as described in table (1). Table (1) Chemical Quantity Unit Sodium hexametaphosphate (commercial name Calgon) 40 g Water 1 L 4. Malt mixer (dispersion apparatus). 5. Thermometer, ranging from 0 to 50 C, accurate to 0.5 C. 6. Stopwatch. 7. 50 g of oven-dry soil passing No. 200 sieve. 8. Balance accurate to 0.01g. 3

Lab. Report NO. 5 PROCEDURE 1. Take exactly 50 g of oven dry (well pulverized soil), and mix with 125 ml quantity of 4% solution of sodium metaphosphate. 2. Allow the mixture to stand about 1 hr. (ASTM suggest 16 hr for clayey soils). Transfer the mixture to the malt mixer cup and add distilled water until the cup is two thirds full, mix for 5 min. 3. Transfers all the contents of the cup to the sedimentation cylinder (being careful not to lose any material). The volume of dispersed soil suspension is increased to 1000 ml by adding distilled water. 4. Use the palm of your hand over the open end of the sedimentation cylinder and carefully agitate for about 1 min. (be sure no soil is stuck to the base of the cylinder). Set the cylinder down, immediately insert the hydrometer, and take hydrometer reading at elapsed time 0.5, 1, 2, 4 min also take temperature reading of sedimentation cylinder and control jar, then take meniscus correction and zero correction from the control jar. 5. Repeat step 4 take another series of hydrometer readings at 0.5, 1, 2, 4min. of elapsed times. Repeat as necessary until two sets of the four reading agree within 1 unit of each other at all four reading time (take average between a pair of readings). 6. Collect additional hydrometer and temperature readings at elapsed time of 8, 15, 30, min followed by 1, 2, 4, 8, 16, 24, 48, 96 hr. CALCULATION 1. Determine temperature correction (C T) from Table (6-3). 2. Calculate corrected hydrometer reading (Rc) from following equation: R c = Ra Zero correction + C T 3. Determine (a) from Table (6-2) or from following equation: a = ( G G x1.65 s s 1) x2.65 4. Calculate %Finer of soil particles from following equation: R x a % Finer = ( C ( ) ) x 100 Ws 5. Calculate hydrometer reading (R )corrected for meniscus only by: 4

R = Ra + meniscus correction Ra = actual hydrometer reading from sedimentation cylinder. 6. Determine effective depth (L) from Table (6-5) by using R. 7. Determine K from Table (6-4) by using G s and T. Lab. Report NO. 5 8. Calculate diameter (D in mm) of particles suspended in the cylinder at time t in minute by: D = K L t Where: L in (cm), t in (min) 9. Repeat all above steps for each hydrometer readings. 10. Use the data from steps 4 & 8 above and plot the % Finer versus D in (mm). 11. Find percent of silt and clay according to BS. 12. Find coarse, medium and fine silt according to BS. DISCUSSION 1. Stokes law does not applied for colloids that are particles smaller than 0.0002 mm? 2. Use the value of hydrometer reading (R) correction for meniscus only to find the value of (L)? 3. What is the effect of the specific gravity (or density) decreases on the hydrometer reading? 2016 5

Lab. Report NO. 5 HYDROMETER ANALYSIS DATA SHEET Name:... Class:... Group No. :... G s of solids = 2.60 Wt. of dry soil, W s =... a =... Meniscus correction = 1 Zero correction = 5.65 1 2 3 4 5 6 7 8 9 10 11 12 Actual Corr. Hydr. L K Time Elapsed Temp. Hdro. Hydr. Corr. % Date Of time Reading Reading Only for from L from D, mm Finer reading min C Meniscus Table Table t Ra Rc (6-5) (6-4) R 0.25 27 31 0.5 27 30 1 27 29 2 27 28 4 27 26 8 27 25 15 27 24 30 27 23 60 27 21 120 27 20 240 27 19 1260 27 15 1440 27 14 2880 27 13.5 R c = R actual Zero correction + C T % Finer = (R c (a) / W s ) x 100 D = K L t Test date: 07/ 12/2016 Signature:... 6

7 Lab. Report NO. 5

8 Lab. Report NO. 5