Internal Partitions - Timber Studs Internal Partitions - Steel Stud

Similar documents
PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Cavity & Smoke Barriers, Parapet & Spandrel Walls

Electrical & Mechanical Services Enclosures - Designer Selector Table

CERTIFICATE OF APPROVAL No CF 429 PROMAT UK LTD

The Passive Fire Protection Handbook

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

Duct Wrap Flexible Wraps

CERTIFICATE OF APPROVAL No CF 422 PROMAT UK LTD

PROMAtect H 4 hour walls. progressivematerials.com.au

Metal Web Floor System

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

PROMATECT hour walls

PROMATECT 100 Solid Partitions

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

PROMAtect h concrete upgrade Concrete and brick walls

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

PROMATECT 100 Passive Fire Protection Building & Construction Solutions

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

PROMATECT -H External Wall With Mineral Wool

PROMATECT -H Access Panels & Hatches.

Adjustable Suspension Hanger Technical Datasheet

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

PARTITIONS & EXTERNAL WALLS 5

FEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.

TECHNICAL DATA SHEET. fire protective board, reinforced full-core plasterboard

UL Design System HW-D-1012 continued

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

June Non - Residential New Build Partition walls

PROMAtect 50 Structural steel. progressivematerials.com.au

Promaseal pillows. progressivematerials.com.au

Not to be distributed outside of FM Global except by Customer

I-STUD Shaftwall System

Knauf C-Form Suspended Ceilings

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

FireWall. High performance fire-resistant wall system. FireWall.

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Kemwell Impact Board. PASSIVE FIRE PROTECTION Specialists for the construction, infrastructure, transport, energy, industrial and commercial sectors.

SECTION SOUND ISOLATION

Ventura Office Partitions. Technical guide

SECTION GYPSUM BOARD

FIRE RESISTANT GLAZING SYSTEMS 8

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

FIRE RATING MATERIAL FIXING NOTES

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

Cavity ShAftwall System

Intertenancy Barrier Systems for Terrace Homes

The Passive Fire Protection Handbook

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.

PROMATECT -H Double Layer Steel Stud Partitions

PROMATECT -S Smoke & Fire Barrier

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

Product Guide Specification

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

A. AISI Specifications for Design of Cold-Formed Steel Structural Members

PROMATECT -H Single Sided Steel Stud Partition

I-STUD Shaftwall System

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

This page was. intentionally. left blank

PROMATECT fi 250 PROMAXON fi Technology Steelwork Fire Protection

Product Guide Specification

GypWall AUDIO The ultimate sound insulating wall system

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

The System U.S. Patent No. 5,913,788

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP

mcr Silboard self-supporting ventilation and smoke extraction ducts

System No. HW-D-0548

KINETICS NOISE CONTROL TEST REPORT #AT001073

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to URBAN SURFACES. Series/Model: Urban Surfaces Soundtec

SECTION GYPSUM BOARD

ROCKWOOL FLEXI insulation. One product, many applications THE PERFECT FIT FOR: ROOFS DORMERS WALLS FLOORS.

The extra strong, extra durable, sound resistant system that you can direct fix to

SECTION GYPSUM BOARD SYSTEM

SECTION NON-STRUCTURAL METAL FRAMING

PROMATECT 50 Fire Resistant Steel Ducts

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

rainspan installation guide horizontally laid panel

Part E robustdetails. robustdetails. January 2018 Update Pack

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Union County Vocational - Technical Schools Scotch Plains, New Jersey

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Union County Vocational - Technical Schools Scotch Plains, New Jersey

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

INTERTENANCY SYSTEMS 2018

THE RSIC SOUND ISOLATION CLIPS. RSIC-WFI (Wall Frame Isolator)

SECTION GYPSUM BOARD SYSTEM

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

rockspan installation guide horizontally laid panel

KINETICS NOISE CONTROL TEST REPORT # AT001084

Smarter. Safer. Leaner.

rondo accessories CONTENTS:

Transcription:

Timber Studs PH Internal Partitions - Steel Stud / hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres or 0mm x No. screws at nominal 00mm centres Installation Method M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab / hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density 00 kg/m, 0mm thick Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail 0mm long round head nails at nominal 00mm centres or 0mm x No. screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab Detail Elevation Detail Vertical section A-A Detail Horizontal section B-B hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, each side mm thick Mineral wool, raw density 00 kg/m, 0mm thick applied in layers of 0mm thickness with all joints staggered between layers Mineral wool seal Timber stud mm x 0mm at 0mm spacing Timber rail mm long round head nails at nominal 00mm centres or mm x No. screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab NOTE: The above construction details can be installed up to m high. Details for walls above m high are available on request.

Steel Stud Internal Partitions - Steel Studs PH/PMF / hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick or PROMINA 0 boards, each side mm thick PROMATECT -H strips 0mm wide, each side mm thick or PROMINA 0 strips 00mm wide, each side mm thick Mineral wool, raw density kg/m by 0mm thick or none if using PROMINA 0 mm thick boards Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Installation Method Concrete wall or floor slab hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick or PROMINA 0 boards, each side mm thick PROMATECT -H strips 0mm wide, each side mm thick or PROMINA 0 strips 00mm wide by mm thick Mineral wool, raw density kg/m by 0mm thick or 0 kg/m by 0mm thick Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab Detail Elevation (continued on next page)

Steel Stud Internal Partitions - Steel Studs PH/PMF (continued from previous page) hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side mm thick PROMATECT -H strips 00mm wide, each side mm thick Mineral wool, raw density 0 kg/m by 0mm thick or 0 kg/m by 0mm thick applied in layers with all joints staggered between layers Mineral wool seal (optional) Steel stud 0mm deep x 0.mm thick at 0mm spacing Ceiling and floor perimeter steel channel 0mm deep x 0.mm thick M self-tapping screws at nominal 00mm centres Detail Vertical section A-A M steel anchor bolt at nominal 00mm centres Concrete wall or floor slab NOTE: The above partitions are approved for heights up to m using framing members as detailed, these constructions are approved for heights up to m with slight construction amendments, please consult Promat technical department for details. Detail 0 0 minutes rating for integrity only in accordance with the relevant criteria of BS : Part can be met using a construction utilising similar steel studs as detailed above, with a single layer of mm PROMATECT fi -H fixed onto one face only. Please note that the board should be placed on the fire risk side as this construction is not symmetrical. Steel stud partitions constructed using minimum mm PROMATECT -H fulfill the relevant criteria of BS with regard to impact resistance, stiffness etc. Please consult your local Promat office for construction details. Detail Horizontal section B-B

Steel Stud Internal Partitions - Steel Studs PH/PMF hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMINA 0 board, each side mm thick a Fire rated gypsum board, each side mm thick Mineral wool seal a Steel stud mm x mm x 0.mm at 0mm centres Ceiling and floor perimeter steel channel mm x mm x 0.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side layers x mm thick with the horizontal and vertical joints between boards staggered by a minimum of 00mm Installation Method Mineral wool seal Steel stud 00mm x 0mm x.mm at 00mm centres Ceiling and floor perimeter steel channel 00mm x 0mm x.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall Mineral wool, raw density 0 kg/m, 00mm thick applied in layers of 0mm thickness with all joints staggered between layers a Detail Vertical section Detail a Detail Horizontal section hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm Sound transmission class: STC PROMATECT -H boards, each side layers x mm thick with the horizontal and vertical joints between boards staggered by a minimum of 00mm Mineral wool seal Steel stud 00mm x 0mm x.mm at 00mm centres Ceiling and floor perimeter steel channel 00mm x 0mm x.mm M self-tapping screws at nominal 00mm centres M steel anchor bolt at nominal 00mm centres Concrete floor slab or wall Mineral wool, raw density 0 kg/m, 00mm thick applied in layers of 0mm thickness with all joints staggered between layers NOTE: The vertical joints between boards will not necessarily coincide with the steel studs, and therefore the two layers of boards should be stitched together using mm dry wall type screws at nominal 00mm centres. NOTE: The above partitions are approved for heights up to m using framing members as detailed, these constructions are approved for heights up to m with slight construction amendments, please consult Promat technical department for details.

Solid Partition PH Solid Partitions hour fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + mm Stagger joints by at least 00mm, fix 0mm layer first Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer 0mm, fixed to perimeter angle using 0mm x No. screws, at 00mm centres. Second layer mm, fixed to first layer using 0mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab / hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + 0mm Stagger joints by at least 00mm Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer fixed to first layer using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab hours fire rating, integrity and insulation in accordance with the criteria of BS : Part and AS 0: Part. Nominal thickness of partition: mm PROMATECT -H boards, 0mm + mm + mm or x mm Stagger joints by at least 00mm, fix 0mm layer first Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer 0mm, fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer mm, fixed to first layer using 0mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Third layer mm, fixed to first two layers using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to over tighten screws Concrete wall or floor slab hours fire rating, integrity in accordance with the criteria of BS : Part, and AS 0: Part with Insulation Criteria of 0 and 0 minutes. Nominal thickness of partition: mm or mm For 0 minutes insulation: PROMATECT -H 0mm + 0mm, stagger joints by at least 00mm For 0 minutes insulation: PROMATECT -H mm + mm, Stagger joints by at least 00mm Steel angle frame 0mm x 0mm x mm M steel anchor bolt at nominal 00mm centres Self tapping screws or similar First layer fixed to perimeter angle using 0mm x No. screws at 00mm centres. Second layer fixed to first layer using mm x No. screws at 00mm centres around the perimeter and down the centre of each panel. Take care not to overturn screws Concrete wall or floor slab Installation Method Detail Vertical section Detail Detail Horizontal section NOTE: The above construction details are applicable for up to.m high. Details for walls above.m high are available on request.

Solid Partition PH Solid Partitions hours fire rating, integrity and insulation in accordance with the criteria of ASTM E. First layer: PROMATECT -H board, mm thick Second layer: PROMATECT -H board, mm thick Third layer: PROMATECT -H board, mm thick Fourth layer: PROMATECT -H board, mm thick Self-drilling bugle head screw fastener No. x 0mm mm x mm staples at 0mm centres Galvanised steel angle mm x mm x.mm NOTE: The above construction details are applicable for up to.m high. Details for walls above.m high are available on request. Installation Method Detail Vertical section Detail Detail Horizontal section

Shaft Wall Partition PMF Solid Partitions The following system is applicable for use in those areas where the full integrity and insulation performance is required, but where access for construction is possible from one side only (e.g. Lift shafts etc). This construction is designed to fulfil the criteria of the relevant standards relating to the compartmentation of lift shafts, and to provide resistance to positive and negative pressures resulting from the movements of the elevators etc. The below details are suitable for wall heights of up to 000mm between substrates. For construction to greater heights, please consult Promat Technical Department. hour and hours fire rating, integrity and insulation in accordance with the criteria of BS : Part : PROMINA 0 board, mm thick I-studs 0mm x mm x 0.mm at 0mm intervals 0 Stud 0mm x 0mm x 0.mm at edge of shaft wall partition Stud 0mm x 0mm x 0.mm as top and bottom track Installation Method PROMINA 0 filler strips, mm thick x mm wide PROMINA 0 cover strips, mm thick x 00mm wide at joints hour fire rating: Mineral wool 0mm thick x kg/m hours fire rating: Mineral wool mm thick x 00 kg/m hour fire rating: PROMINA 0 cover strips, x mm thick x 00mm wide hours fire rating: PROMINA 0 cover strips, x mm thick x 00mm wide PROMINA 0 board, mm thick Detail Vertical section Detail 0 Self-tapping or self-drilling screws at 00mm centres Threaded rod with nuts and washers at 00mm centres NOTE: Steel stud partitions constructed using minimum mm PROMATECT -H fulfill the relevant criteria of BS with regard to impact resistance, stiffness etc. Please consult your local Promat office for construction details. 0 Detail Horizontal section

Single Side Partition PH Suspe nded Ceilings hours fire rating, integrity only in accordance with the criteria of BS : Part with fire from board side. PROMATECT -H boards, mm thick Steel stud 0mm x mm x 0.mm thick at 0mm centres Ceiling and floor perimeter steel channel 0mm x mm x 0.mm thick fastened to concrete with M steel anchors at 00mm centres M self-tapping screws at nominal 00mm centres Installation Method hours fire rating, integrity only in accordance with the criteria of BS : Part with fire from board side. PROMATECT -H boards, layers x mm thick Steel stud mm x mm x 0.mm thick at 0mm centres Ceiling and floor perimeter steel channel 0mm x mm x 0.mm thick fastened to concrete with M steel anchors at 00mm centres M self-tapping screws at nominal 00mm centres NOTE: The construction detailed herein is suitable for heights up to.m. These systems can be installed for heights up to m. Please consult Promat Technical Department for details of the framing members required to achieve greater heights. Installation Method