APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

Similar documents
LAMINATED VENEER LUMBER

SECTION (SOLID/ENGINEERED BAMBOO-EXTERIOR GRADE PRODUCTS)

Specifier Note: Coordinate the following Article with Section Protecting Installed Construction.

SECTION METAL WALL PANELS

SAFETY AND SECURITY FILMS

SECTION PLUMBING PIPING AND PUMPS

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

SECTION METAL WALL PANELS

SECTION FOAMED-IN-PLACE INSULATION

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

VEHICLE BARRIERS

Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3. Tel Fax Web

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

ACOUSTICAL WALL TREATMENT 09840

Specifier Note: Retain material(s) below to conform to project requirements.

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

SECTION DEFIBRILLATOR CABINETS

MortarNet (updated to include Insect Barrier) Master Specification

Specifications for FL-100 Soffit Panel

NatureWood Construction Product Specification Guide

5GLOBAL. specification guide summary PART 1 GENERAL

SECTION METAL WALL PANELS

SECTION CEMENTITIOUS ROOF DECK (CEMENTITIOUS WOOD FIBER PLANK)

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

NewTechWood America, Inc.

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice.

SECTION METAL ROOF AND SOFFIT PANELS

FABRICOIL BASIC January 10, 2006

SECTION METAL ROOF & WALL PANELS

MASTER GUIDE SPECIFICATION

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SHORING & UNDERPINNING 02250

MASONRY MORTARING

SECTION METAL ROOF & WALL PANELS

NRM-7000 Guide Specifications

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

PRODUCT SPECIFICATIONS

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

CS-100 Guide Specifications

CONCRETE BALUSTRADE SYSTEM

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

FABRICATED FIREPROOFED STEEL COLUMNS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

SECTION STAINLESS STEEL WALL PANELS

Phenolic Exterior Wall Cladding

Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System

SECTION WEATHERSTRIPPING & SEALS (THRESHOLDS AND RAMP THRESHOLDS)

SPECIFICATION GUIDELINE

Sample Specification

MASTER GUIDE SPECIFICATION

Sample Specifications

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Dricon FRT Wood Specification

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Sample Specifications

SECTION ROOF ACCESSORIES

PIPING SPECIALTIES 15120

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

SPECIFICATION GUIDELINE

POLYCAST Trench Drain Systems

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

SL150 Guide Specification

SECTION EXTERIOR GRILLS AND SCREENS

Architectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS KALAELOA BLVD, KAPOLEI, HI 96707,

Accella Polyurethane Systems, LLC

SECTION VERTI-LOK - PREFORMED STANDING SEAM ROOF PANELS

1. ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension.

FLOORING TREATMENT

HYDRONIC PIPING

SECTION EXTERIOR SUN SHADES

ML150 Guide Specification

DIVISION 7 - COMMERCIAL FLUID APPLIED DAMPPROOFING 07110

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION SEM-LOK - PREFORMED STANDING SEAM ROOF PANELS

Product Guide Specification

2004 MASTER FORMAT SECTION Façade Panels

BENJAMIN OBDYKE INCORPORATED

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

SECTION ROOF EDGE SAFETY RAILING SYSTEM

HYDRONIC PIPING

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ROOFING AND SIDING PANELS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

AMBICO Limited Section and BLAST RESISTANT STEEL WINDOW FRAME ASSEMBLIES Page 1

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION PRE-ENGINEERED BUILDING INSULATION

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

Guideline Specifications

SECTION DOOR HARDWARE (DOOR BOTTOMS)

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

Transcription:

This specifications document follows the Construction Specifications Institute (CSI) Project Resource Manual (PRM). Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. This document specifies a SolarWall Two-Stage solar air heating system that uses solar energy as fuel to heat or ventilate indoor spaces. The SolarWall systems can be either wall or roof mounted. These solar products are manufactured by Conserval Systems Inc in the United States and Conserval Engineering Inc. in Canada. APPLICABLE UNDER SECTIONS: 23 56 00 SOLAR ENERGY HEATING EQUIPMENT 23 56 13 SOLAR HEATING COLLECTORS 07 42 13 METAL WALL PANELS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Solar air heating system that uses solar energy to heat and ventilate indoor spaces. System is comprised 2-Stage wall system; vent-slit-perforated metal wall system, for first stage and vent-slit-perforated metal wall system behind non-perforated corrugated polycarbonate glazing covering the upper-portion of the solar array for second stage of solar heating to provide higher temperature rise. Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI MasterFormat and specifier s practice. B. Related Sections: 1. Sealants: Division 07 sealant sections. 2. Connections to Ventilation Fans, bypass dampers, Operating Schedules: Division 23 HVAC sections. Specifier Note: Article below may be omitted when specifying manufacturer s proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Section 01 42 19 - Reference Standards may establish the edition date of standards. This article does not require compliance with the standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. 1.02 REFERENCES A. ASTM International (ASTM): 1. ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. 2. ASTM D638 Standard Test Method of Tensile Properties of Plastics after weathering in accordance to ASTM G155. 3. ASTM D1003 - Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics ASTM G155. 1.03 SYSTEM DESCRIPTION A. Performance Requirements: Specifier Note: Insert total fan air volume cfm to be heated by solar energy or insert air volume per unit area of solar heating system below. (Typical range for single stage solar heating system is 1-10 cfm/ft 2. See 10-Part Specifications document for application.) 1. Solar air heating system shall be certified and rated by SAHWIA and bear the Solar A Mark Certificate to demonstrate that the system has been tested and the performance is independently verified. 2. Solar air heating system shall be SRCC OG 100 certified as a 2-stage system. Specified flow rate must be within the range of the tested parameters. 1

3. Supplier of solar air heating system must be ISO 9001:2008 certified by an accredited registrar. 4. Air Intake: Provide a SolarWall 2-Stage solar heating panel system that will provide heating for [ ] cubic feet per minute ( m3/h) of fresh air per square foot of solar panel, or, provide a solar air heating system designed to handle a total of [ ] cubic feet per minute ( m3/h) of fresh air. 5. Solar collector array to be connected to [ ] fans delivering heated outside air to the building in accordance with Section 23 HVAC Specifier Note: If loads are not indicated on the drawings, insert below. 6. Structural: Provide a panel system that will safely withstand dead and live loads [Indicated on the drawings] [ ]. Specifier Note: Article below includes submittal of relevant data to be furnished by the Contractor prior to construction. Coordinate this article with Architect s and Contractor s duties and responsibilities in Conditions of the Contract and Section [01 33 00 - Submittals Procedures] [ ]. 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Section [01 33 00 - Submittal Procedures] [ ]. B. Product Data: Submit product data, including manufacturer s Specifications sheet, for specified products. C. Shop Drawings: Submit installation drawings that show the arrangement and orientation of panels. Include details of stand-off components, panel joints, flashing and trim for closures. D. Samples: 1. Submit color chart of manufacturer s range of standard colors for specified finish. 2. Submit color chip of color to be selected. E. Performance Certificate: 1. Submit Solar A Mark certificate from Solar Air Heating World Industries Association (SAHWIA) 2. Submit SRCC Certificate for 2-Stage system F. Quality Assurance: G. Paint Warranty 1. Submit ISO 9001:2008 Certificate of Registration H. Polycarbonate Warranty Specifier Note: Article below should include prerequisites, standards, limitations and criteria that establish an overall level of quality for products and workmanship for this section. Coordinate article below with Division 01 Quality Assurance Section. 1.05 QUALITY ASSURANCE Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Section 01 41 00 - Regulatory Requirements. Repetitive statements should be avoided. A. Regulatory Requirements: In accordance with Section [01 41 00 - Regulatory Requirements] [ ]. B. Supplier Qualifications: Minimum of 10 years documented experience in both the design and manufacture of building integrated solar air heating systems; and past experience in designing comparable sized 2-Stage projects. C. Solar A Mark: Quality assurance mark governing building-integrated solar air heating systems. D. ISO 9001:2008 Certified: Quality management system for supplier of solar air heating system. E. Optional Site Inspection by Manufacturer: Ensure conformance to installation specifications. Specifier Note: Article below should include special and unique requirements. Coordinate article below with Division 01 Product Requirements Section. 1.06 DELIVERY, STORAGE & HANDLING A. General: Comply with Division 01 Product Requirements Section. B. Delivery: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. 2

C. Storage and Protection: Store materials horizontally on a flat pallet in a dry, clean and shaded location protected from exposure to harmful environmental conditions. D. Handle metal and polycarbonate panels with care to avoid scratches, edge damage and puncturing. Specifier Note: Coordinate article below with Conditions of the Contract and with Section 01 78 36 - Warranties. 1.07 WARRANTY A. Project Warranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer s Warranty: Submit in accordance with Section [01 78 36 - Warranties] [ ] for Owner s acceptance manufacturer s standard warranty document executed by authorized company official. Manufacturer s warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents. 1. Warranty Period: a) System: 12 months from the date of installation or 15 months from the date of shipment, whichever comes first. b) Exterior Panels: 12 months from the date of installation or 15 months from the date of shipment, whichever comes first. c) Paint: 40 years for silicon modified polyester. d) Polycarbonate Panels: 10 years against loss of light transmission due to yellowing. 10 years against hail damage. PART 2 PRODUCTS Specifier Note: Conserval manufactures high performance metal materials that resist the effects of solar UV radiation. Thermal insulation capabilities of SolarWall offer energy savings in service temperatures from -40 to 250 degrees F (-40 to 121 degrees C). Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal or or approved equal or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal, and regulatory) and assignment of responsibility for determining or equal products. 2.01 SOLAR ENERGY HEATING EQUIPMENT; SOLAR HEATING COLLECTORS; METAL ROOF & WALL PANELS Specifier Note: Paragraph below is an addition to CSI SectionFormat. Retain or delete paragraph below per project requirements and specifier s practice. A. Manufacturer: (Choose one) [Conserval Systems Inc. in USA] [Conserval Engineering Inc. in Canada] Contact: Conserval Systems Inc. 4242 Ridge Lea Road, Buffalo, NY 14226 Telephone: (716) 835-903 Fax: (716) 835-4904; E-mail: info@solarwall.com; website: www.solarwall.com. Conserval Engineering Inc. 200 Wildcat Road, Toronto, Ontario M3J 2N5 Canada; Telephone: (416) 661-7057; Fax: (416) 661-7146; E-mail: info@solarwall.com; website: www.solarwall.com. B. System: 1. SolarWall Two-Stage: Comprised of a 2-Stage system where air is heated twice. First stage; air is heated as it passes through the unglazed vent-slit-perforated transpired solar collector. This heated air then passes into the Second Stage, where it is heated again to further increase the temperature rise. The Second-Stage is comprised of another vent-slit-perforated metal transpired solar collector that is covered by corrugated polycarbonate glazing that is NOT perforated. Flat polycarbonate glazing with external support framing is not acceptable. Specifier Note: Select profile, location, type, metal and color below. Color must be a hot color, not cool color formulation to maximize solar absorption. Minimum order quantities may apply for non-standard or non-stock colors or gauges. 3

C. Metal Panel Profile Type: 1. Mounting Location: [wall] [roof] 2. Heating Stages: [two-stage] 3. Metal: [Galvanized steel, 26 gauge, ASTM A653 and ASTM A755]. Please contact Conserval for 24 gauge. 4. Configuration: [Standard roll-formed corrugated metal panels with high & low flats]. 5. Standard Finish: [Silicon modified polyester (SMP) with inorganic and ceramic pigmentation]. Please refer to SolarWall Color Chart or contact Conserval for optional custom colors and solar absortivity of each color. a. Standard 26 Gauge Hot Colors : [Black] [LSR Dark Brown] 6. Solar Reflectance (SR) value: [Black to have SR of 0.06 or less or Solar Absortivity of 0.94 or greater] [LSR Dark Brown to have SR of 0.06 or less or Solar Absortivity of 0.94 or greater]. Cool color formulations that reflect the sun are not acceptable. All other colors to have SR value of 0.25 or less or Solar Absortivity of 0.75 or greater. D. Polycarbonate Glazing: 1. Configuration: [Corrugated polycarbonate panels with high & low flats] 2. Standard UV Protection: [Permanent, co-extruded ultra violet protective layer to block out 99.9% of harmful UV rays and prevent yellowing]. Post-applied coating or films of dissimilar materials are unacceptable. 3. Light Transmission: [ 89%, ASTM D1003] 4. Building Code Evaluation Approvals: [ICC (International Code Council)], [CCMC (Canadian Construction Material Center)]. 2.02 ACCESSORIES A. Stand-Off Components: Provide galvanized steel components to support the panels in a manner as recommended by the manufacturer. B. Flashing: Provide flashing materials to match the metal and finish of the panels. C. Fasteners: Provide corrosion resistant self-drilling screws and rivets as recommended by the manufacturer. Exposed fasteners must be finished to match the panels. 2.03 FABRICATION A. Factory Finishing: 1. Silicon modified polyester (SMP) with inorganic and ceramic pigmentation. Please contact Conserval for Kynar availability. 2.04 PRODUCT SUBSTITUTIONS A. Substitutions: No substitutions permitted. PART 3 EXECUTION Specifier Note: Paragraph below is an addition to CSI Section Format. Retain or delete paragraph below per project requirements and specifier s practice. 3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Comply with manufacturer s product data, including product technical bulletins, product catalog installation drawings and instructions. B. Coordinate with mechanical to ensure SolarWall system is connected to fan inlet and ventilation system. C. Coordinate with controls or building automation system to ensure sequence of operation of solar heater, fans and associated dampers 3.02 EXAMINATION A. Site Verification of Conditions: Verify that substrate conditions [For substrates that have been previously installed under other sections] are acceptable for product installation in accordance with manufacturer s instructions. 4

3.03 PREPARATION A. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. END OF SECTION 5