Ontario Building Code Compliant Door Activation Switches

Similar documents
FORECAST JANUARY 2017

LOW-ENERGY AUTOMATIC DOOR OPENERS FOR ADA COMPLIANCE

Description Accessibility Standards. AODA OBC 2015 Ramps

Americans with Disabilities Act Accessibility Survey

SECTION HARDWARE

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

Priority 2 Access to Goods & Services

Design Aid for Barrier-Free Accessibility in Existing Buildings

Section 1 OBC FADS /13 Access to Parking Areas

CITY OF FORT COLLINS BUILDING STANDARDS SPECIFICATIONS/DIV 8

BUILDING CODE COMMISSION

Hardware. A. PRODUCT DATA: Submit manufacturer's technical information for each item of hardware.

The Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised)

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1

The Uniform Building and Accessibility Standards Regulations

ELEVATORS, LULAS AND PLATFORM LIFTS

Plan Check No. A. ELEVATORS

The Uniform Building and Accessibility Standards Regulations

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

1. Section Steel Doors and Frames. 2. Section Flush Wood Doors 3. Section Aluminum Storefront Doors.

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

INTERIOR SIGNAGE MANUAL

SECTION VERTICAL WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Colorado Mountain College Dillon Campus ADA Entry Vestibule

GENERAL SERVICES DEPARTMENT

DIVISION 10 SPECIALTIES

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION

Introduction. Disclaimer. Table of contents

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

APPENDIX B SIGNAGE STANDARDS

Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13

Construction Standards PAGE

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

PLAYGROUND FENCING AND GATES

Atlas Column Forms COLUMN FORM SYSTEMS MULTI-CHANNEL AL-SPEED

A. Work of this Section, as shown or specified, shall be in accordance with the Contract Documents.

Section A2 Table of Contents ALL GLASS ENTRANCES

Table of contents (click below or use bookmarks)

Date Oct 5, 2015 Page 1 of 13 Sample tag No -- Ambient: 29C Humidity Sample No. 1

Series - 1

ASDA Aluminium Stockists and Distributors Association

Revision Details TECH MANUAL

AMERICAN NATIONAL STANDARD FOR POWER ASSIST AND LOW ENERGY POWER OPERATED DOORS SPONSOR BHMA. bu iiders hardware man ufacturers association

New York City RS 6.1 Photoluminescent Exit Path Markings

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

COUNCIL ORDER No

Dispute regarding the compliance of outward opening doors to a pool area at 19 Wright Road, Point Chevalier

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION. ) refer to the section of the applicable code California Building Code

Michigan State University Construction Standards PAGE

Plan Check No. A. GROUP M OCCUPANCIES. NOTE: General sales, display and office areas together with toilet rooms shall be made accessible. (1110B.1.

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

The following chapters or articles of the New Jersey electrical subcode are amended as follows:

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

Telecab RESIDENTIAL ELEVATOR. Planning Guide

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Description Accessibility Standards. University of Toronto

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

SECTION DOOR HARDWARE

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

GRAB RAILS CATALOGUE 2013

BUILDING CODE COMMISSION

SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

ARCHITECTURAL DESIGN SPECIFICATIONS SG-4 - CRASH RATED SWING GATE

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

University of Texas. Austin, TX. TAS Variance Application Guidelines For Qualifying Historic Structures

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

BUILDING CODE COMMISSION

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

PHYSICAL BARRIERS MACHINE GUARDS ROBOTIC WORK CELLS PERIMETER OR AREAS GUARDS PHYSICAL BARRIERS

SUGGESTED SPECIFICATION for Low Voltage (600V) Generator Paralleling Switchboard

Site Accessibility Survey & Transition Plan

1. Include construction details, materials, individual components and profiles, and finishes.

BUILDING CODE COMMISSION

VII. Notes Pennsylvania Lottery Retailer Accessibility Guidebook

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

Virtually Invisible Access Panels

INTERNATIONAL EXISTING BUILDING CODE

2020 DISPLAY REGULATIONS

Carey Automatic Door, LLC PNEUMATIC OPERATOR FOR SINGLE SLIDING DOOR

PIP ARS08710 Standard Steel Door Hardware Supplier Specification

ENGINEERING EVALUATION

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

Transcription:

Ontario Building Code Compliant Door Activation Switches A Practical Guide for Equipment Specifiers and Installers 2017 Camden Door Controls

2

Introduction As an industry leading manufacturer of control, activation, annunciation and locking products that serve the accessibility needs of persons with disabilities, Camden Door Control is committed to providing new product and application guides that address the most current building code requirements. This guide has been created to specifically address the latest requirements of the Ontario Building Code (OBC), effective January 1, 2015 - in regards to the changing requirements for door activation switches. Please note that this guide does not include detailed information regarding new OBC requirements beyond the scope of door activation switches, particularly new requirements for emergency call systems in universal and barrier free restrooms. (See document number: #4082A006R1) Amendment to 2012 Ontario Building Code Ontario Regulation 368/13 was filed to amend the 2012 Building Code, and is effective January 1, 2015. The amended requirements are designed to substantially enhance accessibility in newly constructed buildings as well as existing buildings that are to be extensively renovated. Renovation projects provide opportunities for enhanced accessibility in existing buildings. Currently, accessibility requirements in Ontario s Building Code only apply to extensive renovations undertaken in suites over 300 square metres in building area, and located on an accessible floor level i.e., on the main floor of a building or on a floor with elevator access. New amendments set out basic accessibility features that must be included in extensive renovations undertaken in smaller suites, or suites located on a floor level that is not fully accessible. Ontario Building Code Compliant Door Activation Switches 1 OBC Regulation 368/13 Extract and Design Guide 3.8.3.3 Doorways and Doors Sentences 3.8.3.3. (3), (4), (5) and (6) of Division B of the Regulation are revoked and the following substituted: (3) Door opening devices that are the only means of operation shall: (a) be designed to be operable using a closed fist, and This new code requirement now excludes many types of door activation switches from use on barrier-free applications. The intent of this provision, together with other provisions (below) clearly mandates the use of push plate and touchless switches exclusively for compliance to the code. 1 (24mm)

(b) be mounted not less than 35 1/2 (900 mm) and not more than 43 1/2 (1100 mm) above the finished floor. A switch is required to be installed between a minimum height of 35 1/2 (900 mm) and a maximum height of 43 1/2 (1100 mm) above the floor. (In Group A, Group B, Division 2 or 3, Group C, Group D or Group E occupancies.) Ontario Building Code Compliant Door Activation Switches 2 (5) Sentences 3.8.3.3.(16) and (17) of Division B of the Regulation are revoked and the following substituted: (17) Except where a proximity scanning device is installed in conformance with Sentence (18), the control for a power door operator required by Sentence (4), (5) or (6) shall: (a) have a face dimension of not less than, (i) 6 (150 mm) in diameter where the control is circular, or This code amendment now requires round switches to be a minimum of 6 (150 mm) in diameter. Other push plate switches commonly used in the past, such as 4 1/2 (114 mm) round, are no longer acceptable. Camden CM-60 Series push plate switches meet this requirement and are available with a wide range of graphics and architectural finishes. (ii) 2 (50 mm) by 4 (100 mm) where the control is rectangular, This code amendment now requires rectangular switches to be a minimum of 2 (50 mm) wide x 4 (100 mm) tall. Other switches used in the past, such as 1 3/4 (45 mm) wide jamb switches, are no longer acceptable. Select: CM-35N 4-1/2 x 2 face plate, for mounting on jamb width box or frames CM-35 4-1/2 x 2 face plate, for mounting on single gang box CM-45 4-1/2 x 4-1/2 face plate, (concealed screws) for mounting on single or double gang box CM-46 4-1/2 x 4-1/2 face plate, (exposed screws) for mounting on single or double gang box All Camden push plate switches are available with a wide range of graphics and architectural finishes

(b) be operable using a closed fist, As stated above, the new code requirement clearly demands the use of push plate and touchless switches exclusively for compliant installations. (c) be located so that, (i) its centre is located not less than 35 1/2 (900 mm) and not more than 43 1/2 (1100 mm) from the finished floor or ground, or A switch is required to be installed between a minimum height of 35 1/2 (900 mm) and a maximum height of 43 1/2 (1100 mm) above the floor. We recommend that switch height be measured to the center of the switch. This amendment now defines that switch height will be the same for all building occupancies. (ii) (Column Switch) it extends from not more than 8 (200 mm) to not less than 35 1/2 (900 mm) above the finished floor or ground, Ontario Building Code Compliant Door Activation Switches 3 A single switch cannot be higher than 8 (200 mm) and not lower than 35 1/2 (900 mm) above the floor. This sentence recognizes the installation of 36 (915 mm) tall push plate switches, which also have a width of not less than 2 (50 mm) Camden CM-75 Series Column push plate switches meet this requirement and are available with a wide range of graphics and architectural finishes. (d) be located not less than 23 1/2 (600 mm) and not more than 59 (1500 mm) beyond the door swing where the door opens towards the control, A switch cannot be closer than 23 1/2 (600 mm) and not more than 59 (1500 mm) from the side of the door and must be mounted to the side of the door latch (not on the side of the door hinge). This sentence clearly eliminates the common practice of mounting narrow, push plate switches directly on door frames. If a suitably spaced hollow metal window or structural frame is the best location to mount a larger push plate switch, we recommend the use of a CM-45 (Concealed Screws) or CM-46 (Exposed Screws) Series push plate switch and CM-44 stainless steel off-set mounting box. This box can be easily mounted on a jamb width frame, while allowing the switch to project beyond the frame, and also provide an attractive back to the switch, if visible.

(e) be located in a clearly visible position, and This sentence is intended to catch the rare projects where there is an architectural obstruction that prevents a clear line of sight to the switch, when approaching the door from any direction. If an alternative location (that also meets other code requirements) is not immediately apparent, it is always best to seek the direction of your local AHJ before installing the switch. Ontario Building Code Compliant Door Activation Switches 4 (f) contain a sign incorporating the International Symbol of Access. This sentence clearly eliminates the common practice of installing activation switches with text only graphics. It is permissible under the code to install a switch with a wheelchair symbol and text, or with a wheelchair symbol only. Camden offers a wide range of stock switch graphics, with wheelchair symbol, and also offers switches with custom graphics upon request. 3.8.3.12. Universal Washrooms (2) A universal washroom shall have, (a) an emergency call system that consists of audible and visual signal devices inside and outside of the washroom that are activated by a control device inside the washroom, and (b) an emergency sign that contains the words IN THE EVENT OF AN EMERGENCY PUSH EMERGENCY BUTTON AND AUDIBLE AND VISUAL SIGNAL WILL ACTIVATE in letters at least 1 (25 mm) high with a 0.2 (5 mm) stroke and that is posted above the emergency button. To the best of our knowledge, Ontario is the first jurisdiction in North America to require the installation of an emergency call system in universal washrooms. Camden has developed a number of new products specifically for this application and has packaged the products in economical and easy to order CX-WEC Series kits. For a complete summary of code requirements, equipment specifications, system designs and point-to-point wiring diagrams, please reference Camden s Code Compliant Emergency Call Systems for Universal & Barrier Free Restroom Guide (#4082A006R1) For a free copy of this guide, please download from our web site www.camdencontrols.com, or contact our customer service department.

About Camden Controls Camden Door Controls offers the most extensive range of high quality door activating, locking, and control products to support any automatic door operator or access control application. We are ISO 9001:2008 registered, with a 20,000 ft. manufacturing facility, and an extensive network of stocking distributors across North America. Our Quick- Ship warehouses in San Diego CA. and Charlotte NC, and main manufacturing facility in Toronto enable Camden to provide customers 5 day ground shipping to any location within Canada or the continental U.S.! Liability Statement Camden Door Controls has created this guide to serve as a general orientation to the topic and assumes no liability whatsoever for errors or omissions in the information contained herein, nor in how this information is understood or interpreted. In all cases, the reader is directed to consult the applicable codes, standards and laws that are in force within the country, state and municipality of their installation, and are further advised to submit their interpretation of the installation requirements to their local authority having jurisdiction (AHJ) prior to purchasing or installing equipment. Ontario Building Code Compliant Door Activation Switches 5 Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control DISCOVER THE BEST IN DOOR ACTIVATING AND LOCKING PRODUCTS! www.camdencontrols.com Toll Free: 1.877.226.3369 40-82A007 Rev.2