Are My Rigid Containers. Maintaining Sterility?

Similar documents
A Sterile Processing User s Guide

DON T OPERATE WITH A FALSE SENSE OF SECURITY.

Competency Guide: Care and Handling of Rigid Endoscopes

Manufacturer s IFUs. What Are They and Why Are They So Important?

INSTRUMENT PROCESSING FROM PREP/PACKAGING TO STORAGE. January 2016

8/23/2012. Continuing Education Contact Hours. How much of your formal education focused on sterilization or sterile processing?

Facility: Sterile Processing Assessment Date: CRITERIA ANSI/AAMI COMPLIANT Number Y N N/A Point of Use Gross contaminant is removed with

3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17

Packaging Systems for Central Service Operations

Loaner Instrumentation

REUSABLE STERILIZATION CONTAINER SYSTEM.

Packaging & Sterilization

One such problem is blood residual inside the channels of a robotic arm.

26/01/2016. A Day in the Life Steam Sterilization Reprocessing. Welcome! House Keeping. From the GoToWebinar page:

Sterile Packaging & The End User

IT HAS BEEN A GOOD MORNING IN CENTRAL SERVICE (CS), AND THEN

01.48 Receiving and Processing Vendor Owned Surgical Instrumentation in the Sterile Processing Department

Sterilization Policy. Georgia Regents Medical Center Policy Library. Policy Owner: Epidemiology POLICY STATEMENT

Unloading, Storage, Distribution, Transportation and Aseptic Presentation of Sterile Items

Objectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016

Quality Assurance with Rigid Containers Katrina Simpson, M.A., CST, CSPDT

Welcome! Thank you for attending today s meeting, it will begin shortly.

Amalgatome SD Sterilization Tray User Guide

Part II Review of key information from ST79, Sections 3-9

PREVENTING WOUND INFECTION BEGINS BEFORE THE PATIENT

FAQFrequently. Asked Questions. Education & Training. 3M Sterilization Assurance Techline

IT HAS BEEN A GOOD MORNING IN CENTRAL SERVICE (CS), AND THEN

ISO How to translate into action Sterile container systems

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

Welcome! How do I get a CE Certificate?

Packaging for Sterilization

WITH THE ADVENT OF THE EVENT-RELATED STERILITY PROCESS,

ARABIC CANADIAN MEDICAL CENTER CSSD POLICIES AND PROCEDURES

Ideal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities

Loaner Program Guidance

ANSI/AAMI ST79 A2:2009 Key Changes in the 2009 Amendment

Loaner Programme Guidance

Loaner Programme Guidance

Aesculap SterilContainer System Instructions for Use Steam, Ethylene Oxide and Vapor Hydrogen Peroxide Sterilization Modalities

Guide for Cleaning, Sterilization and Storage of Reusable Introducers

HRO-50 Water Purifier

Specialty Testing of Steam Sterilizers

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Sterilization Packaging Systems, Preparation and Loading for Steam Sterilization

Medical Device Reprocessing Assessment - General (Cleaning, Disinfection, and/or Sterilization)

3.03 Understand support services

DEFENDO. Sterile Single-use Valves. Procedure

SUBJECT: Detection of residual organic soils inside various channels of lumened items.

SERVICE PARTS LIST G54A BULLETIN NO CHEST CATALOG NO. CABINET CATALOG NO SERIAL

3M s Sterilization Tech Line FAQs Sandra Velte, BA, CSPDT

2. Describe correct actions to take to address sterilization process failures. 3. List possible causes of sterilization process failures.

Lotus. Reprocessing instructions for reusable instrumentation

Lotus. Reprocessing instructions for reusable instrumentation. French/Swiss protocol

Modularity systems. made of high performance synthetic material, silicone and metal. Sterisafe Toolsafe

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Monitoring your decontamination and reprocessing cycle

Fundamentals of Package Engineering & Design

ST 19 Aluminium Manually Controlled Electric Model

AS AN INCREASING NUMBER OF HEALTHCARE FACILITIES

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

3.03 Understand support services

Entellus Medical Sinuscope INSTRUCTIONS FOR USE

Model # 600H-D. 4/2/2012 Page 1 of 6

Model # 612H. 7/11/2016 Page 1 of 6

BONDING, POTTING, WELDING

Operating Instructions

ST 19 T Aluminium Thermostatically Controlled Electric Model

SPECIFICATION OPTICAL TERMINATION BOX for FTTx

PURE WATER. Installation, Operation and Maintenance Manual. Under Counter Water Filtration System Model PWDWHCUC1. Table of Contents !

GAMA Headquarters 355 Lexington Avenue, 15th Floor New York, NY USA INTRODUCTION

Model # 338SM-OP. 9/30/2011 Page 1 of 12

In the Know about.appropriate Use of 3M Attest Rapid Readout Biological Indicators

What Dentistry Can Learn from AAMI ST79. Best Practices for device and instrument reprocessing

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

Obtaining Manufacturer s IFU: Challenges and Barriers

We ve built a STRONG CASE. for changing the way you sterilize. Reusable Sterilization Container System

King Portable Brinell Hardness Tester

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

M R I C. MAERSK Reefer Inspection Criteria. (All Lines) (For use with all Refrigerated Containers (Reefers) in-service) Version 4: 2016

SUPPLIER PACKAGING CODE REQUIREMENTS EFFECTIVE DATE 2/20/2018

Developed and Presented by: Wisconsin Healthcare Engineering Association

Model # 238-U6. 5/24/2013 Page 1 of 11

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Model # 5803SM. 6/15/2018 Page 1 of 5

Testing of routinely sterilized products should

Model # 338S-PR. 5/1/2014 Page 1 of 12

Model # 238HS-P8. 4/27/2011 Page 1 of 11

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

Model # 338S-OP. 9/30/2011 Page 1 of 13

Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900)

Your Sterile Processing Partner. Duraholder IPS

Model # 338S-P. 7/31/2012 Page 1 of 13

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Model # 338S-RDP. 7/31/2012 Page 1 of 13

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Transcription:

Are My Rigid Containers Maintaining Sterility? 1

Are My Rigid Containers Maintaining Sterility? Objectives 1. List the observations to be taken each time a rigid container is prepared for use 2. Describe do-it-yourself tests your SPD can perform to do a quick check on the container s integrity 3. Explain how a minute hole in a container is different from the same size hole in cotton, paper and polypropylene wrap 2

.And the Inspection Begins! Inspect container for defects; should be free from cracks corrosion pitting Tiny crack magnified Rivets and screws should be secure Inspect edges of container lid and bottom to confirm no sharp burrs or dents that could affect the gasket seal or proper closure 3

Tiny crack in dent Tiny hole 80µm Even with Diligent Visual Inspection, No Guarantees Object Millimeters (mm) Micrometers (µm) aka: microns Smallest size human can see 0.100 100 Magnified hole above, too small to see 0.080 80 Staphylococcus aureus bacterium 0.001 1 80 Staphylococcus bacteria standing in a row to reach across the hole that no one can see without magnification!!

All holes Are Not Created Equal Bacteria go right through holes/cracks in containers because it is an open space = nothing to stop them But not through polypropylene non-woven wrap. Why? Two reasons: 1. Thousands of microscopic fibers make up multiple layers of particle traps: let air through, but trap bacteria: tortuous pathway like a complex maze 2. And in some, each fiber is electret treated, making it charged in order to attract & trap any bacteria trying to penetrate the fabric. 5

Contain hole or Crack Screen type; hole size capture Woven cotton reusable B Polypropylene SMS (Spunbond-Meltblown-Spunbond) Tortuous pathway & electret, charged fibers To bacteria You can enter, but never leave 6

Filters and Retention Plates Inspect retention plates for distorted shape bent levers that do not secure plates properly Inadequate spring or compression Verify filter retention posts are secure (don t wobble; not bent) Inspect filter holder to ensure there are no dents, cracks, chips or sharp places Inspect filters to make certain: no holes good fit in holder: fills the space without creases, folds, or crimped edges 7

Assembled Filter Unit Upon securing filter in holder, inspect retention plates to ensure proper locking of the mechanism; does not loosen or pop-out Reusable Valves: Valve itself must not have dents breaks cuts chips foreign debris 8

Gasket Gasket seal must be completely inserted and undamaged with no: cracks cuts tears separation (from seated track position) visible degradation or color change (indicates aging oxidation or chemical damage) is not hardened 9

Gasket Seal Check container lid for bounce upon opening. Absence of noticeable bounce may indicate gasket is degraded no longer pliable ruptured requires gasket replacement Inspect gasket for visible compression indentation formed by the upper lip of the container bottom; should be: uniform and continuous around entire gasket length 10

Latches and Handle Observe latches are not separating from base not loose not bent open up and down easily latch spring is not protruding latch bracket is not separated from lid A solid click must occur when closing latches to confirm securely clasped with enough pressure on gasket to create seal 11

Demonstration Video Dollar Bill Seal Check 12

Demonstration Video Water Leak Check 13

Demonstration Video Water Leak Check 14

Preparation and Assembly Rigid container locks: Confirm handle is not loose handle sleeve is not cracked or torn Must have tamper-evident locks or seals Never use a container with a lock that is not adequately sealed 15

Per Manufacturer Only components of the rigid container system specified by the manufacturer should be used Manufacturer s written instructions for inspection, repair, cleaning and preventive maintenance should be followed observe manufacturers identified indicators for maintenance prescribed frequency per DFU Record date required for scheduled maintenance and document compliance and date 16

Washing When loading washer, all parts must be separated so detergent and water contact all surfaces of all containers Place: container base such that water doesn t collect typically upside down lids at an angle retention plates in instrument basket and/or away from direct, high pressure spray Process per manufacturer s Instruction for Use (IFUs) Use ph neutral detergent to avoid damage Ensure the container bottoms, lids and all components (filters, plates, etc.) are dry prior to assembly 17

Washed After washing and inspection All components completely dry Assemble Load following manufacturer s instructions Follow manufacturer's instructions for sterilization of container and its specific contents 18

Sterilization Verify that the container system and the items to be sterilized have been tested and validated for sterilization cycles used within your facility 19

Sterilization When instructions conflict or are not sufficient, contact the instrument manufacturer for guidance If conflicting directions are not solvable and the device is needed urgently, the instrument manufacturers instructions must be followed. 20

Sterilization For steam sterilization cycles, pre-vacuum sterilizers are the preferred choice Rigid containers: SHOULD BE placed on shelves in a steam sterilizer below absorbent items SHOULD NOT BE stacked in the sterilizer* * EXCEPTION: the manufacturer has provided written recommendations and documentation that stacking of their containers in the sterilizer has been validated. 21

Cool, Then Store Allow rigid containers to cool before removing from sterilizer cart Do Not Place on shelves before cooled as will increase condensation (wet packs) Do Not Touch filters at all but especially while hot as can create contamination channel Protect from puncture and from contamination when transporting to storage area Maintain container in a position parallel with floor while shelving 22

Storage The integrity of a sterile packaged item is event-related The chance of contamination increases over time and with increased handling Sterile storage areas should be maintained with: Temperature ranging from 68º 75º F (20º-24º C) Humidity level ranging from 30 70% At least four positive pressure air exchanges per hour 23

How Many Times Are Your Containers Reused? Junghannss estimated that containers are: disassembled washed reassembled sterilized transported within or outside the facility handled with dirty sharps and disinfected re-used 1,400 to 2,300 times (a low estimate) That s a lot of opportunity for damaging each container Time to renew our insurance policies! Renewed focus on inspection, maintenance, quality assurance 24

Quality Assurance 25

Quality Assurance Quality assurance testing of containers should be performed before initial use and periodically thereafter major change in packaging systems, materials, tray configuration, or content density 26

Quality Assurance Biological testing Place the biological indicator inside the tray, set, or pack being tested, usually in each corner and in the center of the set Verification of the ability to dry the set under user conditions Observe the set for any: condensate on the instruments or package contents wet or moist towels or silicone mats visible water inside the container Evidence of retained moisture will require additional steps to determine the necessary cycle parameters and sterilizer load configuration 27

Continued Sterility Confidence Fast periodic checks on several containers similar to video demonstrations shown are suggested: leak check dollar bill test gasket seal check 28

Quality Assurance For instructions for periodic product quality assurance testing of rigid sterilization containers systems, refer to AAMI s current ST 79 Comprehensive guide to steam sterilization and sterility assurance in health care facilities http://www.aami.org/ 29

Sterile Hospital-associated infections (HAI) kill more people in the US than motor vehicle, breast cancer and HIV combined Surgical Site Infections represent 17% of all HAIs Over 27 million surgical procedures performed annually Essential that every instrument, device and implant we certify as sterile, is indeed sterile Our initials represent our personal professional assurance Seals Worn Abraded Cuts. Creases Slipped from position Lose Hardened Degrading (oxidized) Stretched Dents, cuts, cracks Handle Filter Housing Latches Bolts, rivets, nuts for movement Test bacterial barrier effectiveness Each Use Yearly 30

Dunkelberg Study 216 rigid sterilization containers obtained in-use inventory of 4 hospitals inspected per facilities policy All judged appropriate for maintaining content sterility However, majority (80%) failed to prevent contamination after sterilization when tested with aerosolized bacteria We need to do a better job of inspection, verification, quality assurance 31

We Must Do A Better Job 32

Are My Rigid Containers Maintaining Sterility? For Your Patient s Safety Take the Steps Necessary To Ensure You Are Confident They Are! Thank You!! 33

References Are My Rigid Containers Maintaining Sterility? 1. International Association of Healthcare Central Service Materiel Management (IAHCSMM). In: Lind N, Ninemeier JD, eds. Central Service Technical Manual. 7 th ed. Chicago, IL: International Association of Healthcare Central Service Materiel Management;2007:237-264. 2. Association for the Advancement of Medical Instrumentation (AAMI), American National Standards Institute (ANSI). Containment devices for reusable medical device sterilization. ANSI/AAMI ST77:2006. Arlington, VA : Association for the Advancement of Medical Instrumentation; 2006. 3. Association for perioperative Registered Nurses (AORN). Recommended Practices for Selection and Use of Packaging Systems for Sterilization. In: Conner R, ed. 2010 Perioperative Standards and Recommended Practices. Denver, CO: AORN, Inc.; 2010:447-456. 4. Association for the Advancement of Medical Instrumentation (AAMI), American National Standards Institute (ANSI). Comprehensive guide to steam sterilization and sterility assurance in health care facilities. ANSI/AAMI ST79:2010, ANSI/AAMI ST79/A1:2009 and ANSI/AAMI ST79/A1:2008. Arlington, VA: Association for the Advancement of Medical Instrumentation; 2009. 5. Association for perioperative Registered Nurses (AORN). Recommended Practices for Sterilization in the Perioperative Practice Setting. In: Conner R, ed. 2013 Perioperative Standards and Recommended Practices. Denver, CO: AORN, Inc.; 2013. 6. Update: The Joint Commission s Position on Steam Sterilization in: The Joint Commission Perspective, July 2009, Vol. 29, Number 7; p.8,11. 34

Selection and Use of Rigid Containers for Sterilization Additional Resources Association of perioperative Registered Nurses (AORN) 2170 South Parker Road, Suite 300 Denver, CO 80231-5711 Phone: 800-755-2676; Fax: 303-750-2927; www.aorn.org Association for the Advancement of Medical Instrumentation (AAMI) 1110 North Glebe Road, Suite 220 Arlington, VA 22201-4795 Phone: 703-525-4890; Fax: 703-276-0793; www.aami.org The Joint Commission One Renaissance BLVD Oakbrook Terrace, IL 60181 Phone: 630-792-5000; Fax: 630-792-5599; www.jointcommission.org Centers for Medicare and Medicaid Services (CMS) 7500 Security Boulevard Baltimore, MD 21244 Phone: 877-267-2323; www.cms.gov 35

Selection and Use of Rigid Containers for Sterilization Additional Resources American Hospital Association Division of Quality Control and Management One North Franklin Chicago, Illinois 60606 Phone: 312-422-3000; Fax: 312-422-4796; http://www.hospitalconnect.com/ah; a/about/index.html Association for Professionals in Infection Control and Epidemiology, Inc. (APIC) 1275 K Street, NW, Suite 1000 Washington, DC 20005-4006 Phone: 202-789-1890; Fax: 202-789-1899; www.apic.org Centers for Disease Control and Prevention (CDC) Hospital Infections Program 1600 Clifton Road Atlanta, GA 30333 Phone: 800-311-3435; www.cdc.gov 36