Study on Waterproof and Air Permeability of Inorganic Insulated Decorative Panel

Similar documents
Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

MOISTURE VAPOR MOVEMENT AND VAPOR PERMEANCE

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

Thermal efficiency of a modified thermal storage wall containing phase change material in comparative test periods

Effect of insulation ground on anti-condensation in rural residence

Influence of Retro-reflective Material on Public Buildings Energy Consumption in Different Climate Regions

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

ENERGY SAVING INNOVATION IN CHINESE TRADITIONAL BUILDINGS. L. Zhu Nanjing University of Technology China

Buildings XI Conference Workshop 2: Thermal Mass IV Assessing Thermal and Moisture Control Benefits of PCM Components by Hygrothermal Simulation

Refurbishment measures of historic masonry construction Vilnius

Experimental Assessment of Hygrothermal Performance of Wood Frame Wall System in Suzhou's Lake Tai Climate Zone

Concept 4: T1b. ETICS applied to sandwich element internal layer with smooth element surface

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

How-to: Commissioning Design Reviews for the Building Envelope

4. Insulation of external walls

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

WATERPROOFING MATERIALS

DATA SHEET. Multi-adherent coating: adheres on all construction materials, including iron, galvanized and aluminum

Prefabricated Passive House construction: Case study in Jinan, China

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

THERMO SOLUTION. Ceramic Thermal Insulating Coating

The Building Envelope Defined

Index. STP779-EB/Jul. 1982

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

Product introduce: Thermal insulation, based on the value of U (1. Rate of thermal transmitting 2. Rate of thermal reflected)

additional cooling energy consumption. Because the thermal resistance of windows has always been a weak point, even with vacuum glass or low-e glass,

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Energy Consumption Measurement of Energy-saving Buildings and Analysis of Simulation Example

Available online at ScienceDirect. Procedia Engineering 146 (2016 ) 60 68

Effect of energy renovation on thermal sensation and comfort

Condensation - Prevention and Control

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Condensation Problems in Cool Roofs

Analysis of the Window Side Thermal Environment Formed by Air Barrier. Technique in Winter Conditions and Its Economy

Design of Sunshade Board with South External Window of Residential Building in Hangzhou Based on Software Simulation Analysis of Energy Saving

Quality NBR Insulation

6. Moisture Design. Objectives: 3. Prevent vapor condensation (surface, concealed) 4. Prevent rain penetration

New Opportunities For Spray Polyurethane Foam

The Study on Green Energy-saving Buildings Design. Li Weifang

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

DATA SHEET. Once applied, it remains a continuous and without crossover point support, highly resistant to atmospheric agents.

Energy Analysis of Using Thermal Mass in a Hot Humid climate

Insulation in Low Profile Cross Ventilated Freestall Facilities TAKE HOME MESSAGES

THERMAL PERFORMANCE OF WALL-ROOF INTERSECTION AREAS IN THE EXTERNAL ENVELOPE OF RESIDENTIAL BUILDINGS M.C. ALTUN

Thermal Characteristics of a Vernacular Building Envelope

Energy equivalent R-value

The Right Balance of Breathability.

EXTERNAL WALL PERFORMANCE IN RESIDENTIAL BUILDINGS IN HOT CLIMATE COUNTRIES

BUILDING SCIENCE CORPORATION DIGEST OF INSULATED METAL PANELS PERFORMANCE REDEFINED

The Importance of Slab Edge & Balcony Thermal Bridges

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

Influencing Factors on Ground Heat Balance of GSHP System Xiaohong Zhang1, a *, Zehua Liu2,b, Chao Zhang3,c and Long Ma4,d

Effects of external window form on residential building energy consumption

CEN/TC 89 - Thermal performance of buildings and building components

Products... Your Projects will Trust. Amazing PLASTERING & SCREEDING Product

The Role of Control Layers in Building Enclosure Design

Data Sheet 3611 Englisch


BUILDING SCIENCE CORPORATION DIGEST OF INSULATED METAL PANELS PERFORMANCE REDEFINED

Experimental Study on Thermal Performance Improvement of Envelop Integrated with Phase Change Material in Air-conditioned Room

STUDY ON WETTING AND DRYING OF CLAY BRICK HAVING SURFACE COATINGS

ENERGY SAVINGS FOR LIFE

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Exclusive US Representative for Kolmer Industries, a European manufacturer of patented coatings and pigmentation for over 75 years.

Thermo Active Building Systems Using Building Mass To Heat and Cool

Procedia - Social and Behavioral Sciences 216 ( 2016 )

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

RESTORATION MEASURES THAT SAVE ENERGY. Insulating Without Losing Face

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

The Economic Benefits Analysis on Rural Energy-Saving Housing of Northern China-A Case Study of Woniuhe New Rural Construction, Zhalantun City, China

RETRACTED ARTICLE. Energy Saving Measures and Strengthening Thermal Insulation Construction Technology in Residential Building Design.

A lime based mortar for thermal insulation of medieval church vaults

RESULTS OF LONG-TERM ENERGY EFFICIENCY MONITORING OF TEST BUILDINGS UNDER REAL CLIMATIC CONDITIONS

RADON ABATEMENT FROM THE GROUND UP

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Application of Waterproof Technology in Construction Engineering

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times.

The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Building Enclosure Detailing for Walls and Low-Sloped Roofs

BUILDING EXTERIOR SHELL TRAINING

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

FOAM SEALANT STRIPS GLAZING TAPES JOINT BACKING RODS

LIGHTWEIGHT WOOD-BASED WALLS WITH VARIOUS THERMAL INSULATIONS: LONG-TIME MEASUREMENT AND SUBSEQUENT COMPARISON WITH HAM SIMULATION

ARMAFLEX SHEET AL / KY / AL-KY

Contact Adhesive, Adhesive Paste

EXPERIMENTAL ANALYSIS OF WATER AND WATER VAPOR TRANSPORT IN COATING- SUBSTRATE SYSTEMS

External Reinforcement System

Energy consumption and thermal comfort in a passive house built in Romania

EnVision. EnVision. Front cover. intelligent glazing system. intelligent glazing system. EnVision Fact Sheets

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Smart Vapor Retarders

PERFORMANCE COATINGS. PRODUCT CATALOG Vol. 18

Assessing the energy performance of modern glass facade systems

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

Transcription:

Study on Waterproof and Air Permeability of Inorganic Insulated Decorative Panel Hu Xiang-lei 1, a, Wang Hong-jun 1 and Gao Ying 2 1 College of Architecture and Urban Planning, Tongji University, China 2 School of Art and Design, Shanghai Institute of Technology, China Abstract. According to the climatic characteristics, the paper investigates relation between waterproof and air permeability of inorganic insulated decorative panel. The paper believes there are two main problems in the waterproof of inorganic insulated decorative panel, one is the gap is a weak link for waterproof as some weather proofing silicone sealants have poor elastic modulus, the other is the failure of construction details causes partial waterproofing failure. The composite panel system is best supplied in a complete set by the system supplier, which is a main comprehensive solution to the waterproofing problem of the composite panel. Through analyzing software simulation and experimental construction, the paper puts forward suggestion that hot summer and cold winter areas should take practical technical measures, including the use of the protective layer with high water vapor flux density or the installation of exhaust plugs in the outer wall base, or setting water vapor escaping channel such as PVC exhaust plug in the glue seam, in the actual project. 1 Introduction Prefabricated in the factory, inorganic insulated decorative panels are composite plate products made of insulation materials, decorative panels, adhesives and connectors with excellent fireproof performance. At present, rock wool board and expanded perlite board are the main thermal insulation materials of the above composite panels. The Yangtze River Delta Area is hot and rainy, and has rain and heat over the same period. Waterproof and air permeability has a greater impact on the function of the composite panel and are closely related to energy efficiency, durability and feeling of comfort. Water resistance requires that composite panel materials can resist the intrusion of external liquid water; air permeability requires that indoor and outdoor water vapor migration should go normally. 2 Waterproofing problem Inorganic insulated decorative panels avoid or reduce the liquid water from entering the inner system to achieve the purpose of waterproofing of materials by improving the own water-repellent properties of materials. At present, fiber rock wool board and inorganic mortar of the insulation materials of the inorganic composite panel are mixed with hydrophobic agent, and with the hydrophobic ratio controlled in a reasonable range it has enough cohesive force to ensure system security [1]. In addition, the decorative layer, such as fluorocarbon coating, real stone paint and elastic coating, has a waterproof function; completely foamed polyurethane caulking material forms a dense waterproof layer; the weather proofing silicone sealant also features sealing and waterproofing performance. There are two main problems in the waterproof of inorganic insulated decorative panel: 1) The gap is a weak link for waterproof as some weather proofing silicone sealants have poor elastic modulus, and the flexibility fails to meet the deformation of composite panel, causing cracking in case of large temperature difference between day and night, and large thermal expansion and cold contraction at the gap. 2) The failure of construction details causes partial waterproofing failure. For example, the horizontal thermal insulation decorative panel of cantilever should be paid attention to the lapping part to prevent water penetration into the insulation system; the insulation decorative panel at the outside windowsill should have a drip construction at a certain slope. Figure 1 shows the optimization of the waterproof construction of the node in the atlas of inorganic insulated decorative panels. Inorganic insulated decorative panels are made of different building materials whose performance is not the same. The composite panel system is best supplied in a complete set by the system supplier to ensure compatibility and matching of materials, which is a main comprehensive solution to the waterproofing problem of the composite panel. In mature markets such as Europe, external thermal insulation systems being supplied by suppliers in complete set has become the norm. a Corresponding author: huxianglei@163.com The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

(a) Gap faced the water before modification. (b) It is suggested that the gap should be located in the bottom of the shelter, with width of composite panel not more than 600mm, and be fully adhered to the convex window bottom plate. (c) There was no setting for water dripping in the upper part of the window hole before modification. (d)it is suggested that the upper part of the window hole should be tilted by 3%. Figure 1. Waterproof construction improvement. 3 Air permeability problem The external factors affecting the wall condensation include indoor and outdoor temperature and humidity; the internal factors include wall permeability and thermal conductivity. The temperature and humidity of the air in the wall are calculated according to the temperature, humidity, permeability and thermal conductivity of material [2]. In hot summer and cold winter area, the temperature is high in summer: the average temperature of hottest month is 25 ~ 30, the highest temperature is above 40, and the air relative humidity is between 70% ~ 80% or even higher; while the outdoor temperature is low in winter and the average daily temperature of the coldest month is 0 ~ 10. When the outdoor temperature is low and the relative humidity is high during winter heating, and in the intermittent period after the cold storage of the long-term operation of air conditioning in the summer, the water vapor in the wall will migrate and condensate in the wall under the comprehensive action of the indoor and outdoor conditions, causing condensation and mildew. Because the simulation of the wet environment is more difficult than that of the thermal environment, some simulation software avoids the problem of the wet characteristics of the envelope structure, so the study on water vapor condensation in the wall is less plentiful. The existence of condensation of the inorganic insulated decorative panel is studied as below using the software of PKPM Ver1.3, Ptemp1.0 and BEED. 3.1 Calculation using PKPM software Version 1.3 The condensation of the envelope structure of the heating building is calculated by the software in accordance with Shanghai construction specification of Design Standard for the Energy Efficiency of Residential Building(DGJ08-205-2011). The software is designed to only check reinforced concrete walls. Indoor temperature calculated t i is 18, outdoor temperature t e calculated in winter: -2, indoor relative humidity in winter: 60.00%, dew point temperature T: 10.15. The parameters of the material are shown in Table 1. 2

Table 1. Condensation Checking Calculation. the most unfavorable heat bridge type material of each layer thickness (mm) thermal conductivity W/(m K) heat storage coefficient W/( m2 K) thermal thermal resistance value inertia index ( m2 K)/W D=R.S correction factor α inorganic insulated decorative panel 40.0 0.040 0.51 0.63 0.38 1.20 reinforced concrete 200.0 1.740 17.20 0.11 1.98 1.00 gypsum plaster mortar 20.0 0.760 9.44 0.03 0.25 1.00 sum of the layers 250.0 0.77 2.61 normal resistance Ro=Ri+ R+Re=0.92( m2 K/W) Ri= 0.110( m2 K/W);Re=0.040( m2 K/W) Condensation calculation formula:, wherein t i is the winter indoor designed temperature calculated; internal surface temperature; the heat transfer resistance ( m2 K/W) in heat bridge part; t e is the winter outdoor temperature calculated; Ri is the internal surface heat transfer resistance ( m2 K/W); it is calculated that θ i =15.60, so θ i T dew point. According to Section 4.0.18 in Design Standard for Energy Efficiency of Residential Building (DGJ08-205-2011), condensation will not occur on the inner surface of the wall of the inorganic insulated decorative panel [3]. 3.2 Calculation using Ptemp1.0 software heat transfer coefficient K =1/Ro=1.09 Ptemp1.0 software is prepared by the Research Institute of Building Physics, China Academy of Building Research. The two-dimensional temperature field calculation software it developed can be used as a thermal bridge calculation analysis tool. The minimum temperature of the inner surface of the wall in winter is calculated respectively with the aerated concrete block wall and the concrete wall with the same parameters and boundary conditions as the PKPM software Version 1.3. The results are shown in Figure 2 and Figure 3. The calculation shows that the temperature of the inner surface of the wall of inorganic insulated decorative panels in winter is close to the indoor temperature, and the water vapor in the aerated concrete block wall and the concrete wall is not likely to produce condensation when moving from indoor to outdoor. Figure 2. Rock wool composite panel (40mm). Figure 3. Inorganic mortar rock wool composite panel (40mm). 3.3 Calculation using BEED software The simulation software of BEED follows the building thermal calculation method in Thermal Design Code for Civil Building(GB50176-93), and the building energy consumption simulation part is mainly based on the building load calculation method in Code for Design of Heating Ventilation and Air Conditioning(GB50019-2003) and the HVAC Design Manual prepared by Lu Yaoqing. The software is installed with the databases of saturated vapor pressure, building materials 3

classification, building materials thermo physical properties parameters and solar radiation absorption coefficient. The Yangtze River Delta Area is hotsummer and cold-winter zone. The climatic conditions are similar there. The meteorological parameters of Hangzhou in the Yangtze River Delta Area are calculated and the condensation is reviewed by BEED. The results show that there is possibility of internal condensation near the outer surface of aerated concrete block wall (Figure 4). Figure 4. Wall condensation checking calculation. Different software has different design concepts, and the results are deviated. In the earlier product experiment of the inorganic mortar composite panel, the filler wall on the northern side had local condensation &bubbling problem, matching the BEED calculated results. The water absorption capacity and water vapor flux density of the composite wall should be satisfied at the same time, reaching a comprehensive balance. As the experimental building is not equipped with exhaust pipe structure, there is a problem of poor coating ventilation. In the latter period, the composite panel adopts the coating with larger vapor flux density, and the bubble disappears in the same absence of exhaust pipe. In order to make less water enter the wall, External Thermal Insulation Composite Systems Based on Expanded Polystyrene(JG/T149-2003) provides that the external insulation system s 5mm thick protective layer should have a water absorption of less than 500g/m 2. The water vapor penetration amount of the protective layer should be greater than that of the insulation layer and the water vapor flux density of the protective layer should be greater than 0.85g/(m 2 h) [4]. The provision also has a reference value for the inorganic insulated decorative panel. If the water vapor flux density of the coating is slightly lower, the surface color distortion is likely to happen, and if it is severely lower, mold and thermal performance deterioration are likely, or even thermal performance damage is likely. 4 Conclusion When the water resistance and air permeability meet the suitable ratios, the composite panel will provide good protection [5]. At present, the composite panel waterproof technology is mature. For example, the actual project is supplied by the system supplier in complete sets; the responsibility subject is clear; the construction follows the provisions of Technical Specification for Waterproofing of Exterior Wall of Building (JGJ/T235-2011); waterproof quality problems can be avoided. Air permeability is the focus of attention for composite panel. Air permeability requires that the material should not have water vapor diffusion resistance, and should gradually increase from the inside to the outside. The national standard which is based on the fact that the actual situations of all kinds of thermal insulation decorative composite panels are complicated, has canceled the requirement on water vapor transmission performance. The Materials of External Thermal Insulation Systems Based on Insulated Decorative Panel(JG/T287-2013) provides that the water vapor transmission performance will not be checked if inorganic insulated materials are adopted or the system has a breathable construction. However, according to the above simulation calculation and practical experience, hot summer and cold winter areas should take practical technical measures, including the use of the protective layer with high water vapor flux density or the installation of exhaust plugs in the outer wall base, or setting water vapor escaping channel such as PVC exhaust plug in the glue seam, in the actual project. Only in this way can the composite panel be resistant to the intrusion of liquid water from outside and allow the normal migration of internal water vapor. Acknowledgements This paper is supported by the Foundation of Green Building and Construction Industrialization (Grant No. 2017YFC0702402). References 1. D.B. Crawley, L.K. Lawrie, ASHRAE J (2000) 2. M. Bomberg, J. Lsiburek,F. Nabhan, J Build Phys, 1, 227-248 (1997) 3. M.S. Mohsen, Energ Convers Manage, 42, 1307-1315 (2001) 4. Z. Huang, F. Tu, J. Liang, China Archit Build Press (2011) 4

5. E. Kosseeka, J. Kosny, Energ Buildings, 34, 321-331 (2002) 5