Optimization of FCCU Expansion Joint Application, System Design and Reliability Considerations. Tej Chadda Director, Technology Technical Services

Similar documents
Expansion Joint Data Sheet and Technical Specification for FCC Units

FCCU EXPANSION JOINTS FOR FLUID CATALYTIC CRACKING

Fatigue Life & Reliability Consideration During Field Repair of Coke Drum & Piping

Pipe Stress Analysis Where Do I Start?

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

PETRO- CHEMISTRY APPLICATIONS

316 L RUBBER EXPANSION JOINTS CENTRAL HEATING SYSTEM PIPE EXPANSION JOINTS FABRIC EXPANSION JOINTS FAN-COIL FLEXIBLE CONNECTORS FLEXIBLE METAL HOSES

Metallic expansion joints Issue 1

2012 IPC Sections

Gas Turbine & Combined Cycle Plants

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

CHAPTER 4. Design of Innovative Creep Testing Facility under Flowing. Sodium

Technical information

Failures of High Alloy Expansion Bellows in Refinery Catalytic Cracking Units

Standard Specification for Circular Metallic Bellows Type Expansion Joint for HVAC Piping Applications 1

HIGH- TEMPERATURE APPLICATIONS

2015 IPC Sections 308 through 316

Non-Metallic Expansion Joint

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

8. Conclusions. 8.1 Final Conclusions:

applications and fabric types fabric expansion joints

Arms Group Drainage System. 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve

Competence in Metal Expansion Joints

COMPLETE REVISION April Process Industry Practices Piping. PIP PNC00004 Piping Stress Analysis Criteria for ASME B31.

DIN EN : (E)

GREEN THREAD Piping Systems

...because we are the GOLD STANDARD in the manufacture of expansion joints and hoses!

Part Number movement overall length (mm) + or - mm total mm

Part Number movement overall length (mm) + or - mm total mm

PArt NumbEr movement overall LENgth (mm) + or - mm total mm

East Central College

Examples Page 43 of 45


Flexider STEAM TURBINE INDUSTRIAL CROSSOVER EXPANSION JOINTS. An IMCI Company

ABS and DNV Type Approved Products

ENGINEERED PRODUCTS (PTY) LTD FABRIC & METAL EXPANSION JOINTS

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

U.S. Bellows, Inc. Worldwide Leader in Metallic and Fabric Expansion Joints. Fast Turnaround Repair Replace Refurbish Quick Delivery

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

3.2 Dimensional tolerance for the expansion bellows should be as per EJMA.

W A R R A N T Y. CSA standard B51 certified. Inspected and tested by the Technical Standards and Safety Authority of Canada.

JLAB-TN /15/2007. JLab Cryomodule Thermal Shield Circuit Piping Design per ASME B31.3 Edward F. Daly, Gary G. Cheng and John Hogan

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

Lifting Lug Standard on all units, for ease of installation. Multi-Ply Bellows Laminated bellows offer maximum flexibility and endurance ONS

For ASME Committee use only.

PIP PNC00001 Pipe Support Criteria for ASME B31.3 Metallic Piping

Internals for Radial Flow Reactors

Corrosion in GASCO Habshan CBA Units and its mitigation

Girth Weld Failure Analysis In Coker BlowdownHeaders

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Series 5500 Bellows Pump Connectors Catalog 474E

7. Allowable Fittings.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

GTT Pluto II Subsea Cryogenic Pipeline

ASME B31.3 Process Piping

Engineering Specifications

Engineering Specifications

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION HANGERS AND SUPPORTS FOR PLUMBING

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

A MEMBER OF EURO-QUALIFLEX EXPANSION JOINTS

DOUBLE WALLED PIPING SYSTEMS

Engineering Specifications

Table of Contents. Thermal Expansion Data...9 Sizes Available...3. Installation Instructions...10 Materials Available...3

Keywords: Heat exchanger, I-DEAS, Expansion joint, EJMA. Fig-1 Photograph of bellows

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

More about Fabric Expansion Joints (Functioning/Operating Principle) FUNCTION

EQT MIDSTREAM DESIGN AND CONSTRUCTION MANUAL DESIGN STANDARD WELDING AND JOINING 3.4 HOT TAP AND BRANCH CONNECTIONS Total Pages: 13

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Style 206 Product Specification

. SECTION HANGERS AND SUPPORTS

PIP VESST002 Supplemental Design and Fabrication Specification for Shell and Tube Heat Exchangers ASME Code Section VIII, Divisions 1 and 2

Storage & loading on site SOFREGAZ

Basic Pipe Stress Analysis Tutorial

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

PIP VESST002 Supplemental Design and Fabrication Specification for Shell and Tube Heat Exchangers ASME Code Section VIII, Divisions 1 and 2

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Expansion Joints Guide Module 6 - Low Pressure Expansion Joints General - Standard Program (EFB) - Installation Instructions - Technical Data

STRESS ANALYSIS USING ACTUAL COKE DRUM BULGE PROFILES A CASE STUDY. Daryl K. Rutt, Richard D. Clark. CIA Inspection Inc.

This specification describes the minimum requirements for industrial thermal insulation.

Lecture 1: Introduction to Mechanical design consideration for process equipment

CHAPTER 1 INTRODUCTION TO PIPING SYSTEM

QUALITY ASSURANCE SPECIFICATION WELDING HEAT TREATMENT PAGE 1 OF 6

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Stainless Steel Aeration Equipment Specification

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Style 204 EPS Product Specification

NDE Based Finite Element Modeling & Analysis of Wall Thinning in CANDU Feeders

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

DESIGN AND THERMAL ANALYSIS OF HIGH PRESSURE CASING OF A STEAM TURBINE

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SPECIFICATIONS FOR PRESSURE VESSELS - THEIR TRENDS AND CHALLENGES FOCUS: HYDRO-PROCESSING REACTORS MADE FROM 2 ¼ Cr 1Mo V (Enhanced Steel)

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

SECTION VIBRATION ISOLATION FOR PLUMBING PIPING AND EQUIPMENT

Vibration-Induced Fatigue Failure of Discharge Bottle Fitting Connections A Case Study

Daytona Beach Pier Building Renovation Jun 2010

Collectors. Water Treatment & Chemical Processing

Transcription:

Optimization of FCCU Expansion Joint Application, System Design and Reliability Considerations Tej Chadda Director, Technology Technical Services

Optimization of FCCU Expansion Joint Expansion Joints in FCCU Application Basic Considerations Expansion Joints are the Weakest Link in the system ELIMINATE OPTIMIZE EJ by composite system design approach Consider effect of refractory on the stiffness of the system Implement Design & Fabrication UPGRADES of EJ s MONITOR movement during Dry-out and Operation Routine INSPECTION and PREVENTIVE MAINTENANCE VENDOR SELECTION is Key Hot Wall versus Cold Wall Orientation Vertical versus Horizontal 2

Outline of Routine Inspection and Monitoring program

4

5

Systematic approach to Optimize FCCU Expansion Joints Composite System Design Approach Eliminate EJ Minimize EJ Design Upgrades Fabrication Upgrades Proper Installation Monitor EJ during dry-out and Operation Inspect EJ during shutdown Preventive Maintenance of EJ 6

DESIGN Composite System Design Approach All disciplines working together, NO SILO APPROACH Series Versus Parallel Design Vessels / Structures / Piping working together Mechanical Design Diagram Construction and Lift diagram Refractory Dry-out Diagram 7

DESIGN (cont d) Primary Mechanical Design Consideration in an FCCU Layout, Thermal Growth, Structure, Equipment Large Diameter (Refractory Lined) Transfer Lines High Operating Temperature Cold Wall vs Hot Wall Effect of refractory lining on stiffness and loading Thermal Movement and Banana Movement in transfer lines Erosion Upsets and Abnormal Operations including SLUMP Case Refractory and Thermal Conditions during Dry-Out Expansion Joint Application and Optimization 8

DESIGN (cont d) Expansion Joints in FCCU Application: Design Basis Preferred Orientation Vertical with Downward Flow Normal, Upsets, including SLUMP Condition Thermal Movement and Banana Movement Equipment Fabrication and Construction Tolerances Avoid Torsion Consideration of Out-Of-Plane Movement Stability of Bellow Support of Center Spool Use of Pantographic Linkage, Gimbal ring, slotted Hinge Bar 9

DESIGN (cont d) Expansion joint application and Design Optimization Consider the effect of refractory lining on stiffness of duct. Perform FEA to determine vessel nozzle flexibility Perform structural analysis to determine restraint flexibility Determine effective modulus of elasticity of duct, Eeff. Calculate equivalent duct thickness, teq Use teq to calculate reduced flexibility factor, Keff, of bends Perform analysis based on nominal t, CA, Eeff and Keff Perform FEA of nozzle based on load, stress and distortion 10

Effect of Refractory Lining on the Stiffness of Steel Pipe; (Ref PVP- Vol. 53) 11

Regenerator Flue Gas Nozzle FEA Flue Gas Outlet Nozzle & Plenum 12

Vendor selection is key. EJ Fabrication Upgrades and Consideration Use of 2- Ply testable bellows Centerline of bellow and Line Seal to coincide Gimbaled pantographic linkage to provide center spool support & accommodate movements without binding 2- Thermocouples per bellow to measure bellows skin temperature in service. Hot Blankets to provide heating in those unique circumstances where the bellows will operate below the acid dew point in service. 13

Fabrication (cont d) BELLOWS 2-Ply Testable Bellows and Hot Boxing Materials Selection and Corrosion consideration Condensation Protection Forming Attachment to Body Purging versus Packing Use of telescopic liner to coincide with center of bellow 14

Fabrication (cont d) Provisions for a future clamshell. Put in bands and have room under the hinge for this. Not all current designs have the room for a clamshell. Sealable covers. This is a backup to the clamshell in case everything goes wrong you can box the leaking bellows in online. Cr-Mo weld inlay. 15

16

(Fabrication & Vendor Data) Design / Calculations EJMA & ASME B31.3 Design Basis FEA s Bellow Temperature FEA Liner to Spool Intersection FEA Pressure Retention and Local Stress FEA Floating Ring Design Clearance Internal Sleeve to Spool Clearance Slotted Hinge Bar Bellow Movement Calculation using field data 17

Monitoring during Construction and Refractory Dry-Out Minimize Fabrication and Construction Tolerances Monitor Proper Installation and Field Fit-Up of EJ Add thermocouples at critical locations to monitor system temperature during refractory dry-out. Monitor Thermal Operation during field dry-out and verify to be same as system design basis Monitor and verify Expansion Joint, spring hanger and system movement as designed 18

(On-line Monitoring) Routine Monitoring of Expansion Joint during OPERATION Monitor Bellows movement on routine basis to verify any sign of excessive actual movement over Design limit. Monitor 2-ply testable bellows for any leaks Monitor bellow temperatures using installed thermocouples. Keep between (400 800) deg F range or as per Spec. 19

(Bellows Movement Monitoring) 20

(Bellow Temperature Monitoring) 21

(On-line Monitoring) Routine Monitoring of Expansion Joint during OPERATION Watch for bellow temperature rise over time. This will indicate if the internal pillows or braid seal may be damaged or external insulation over bellows require any changes Look for limit rods that have bottomed out. This is a sign of attempted over-movement. Look for any binding hardware such as a non-gimbaled pantograph that is trying to move in out-of-plane lateral. 22

(Bellows Movement Monitoring) Calculate Axial Movement Calculate Lateral Movement (in-plane and out-of-plane) If exceed design basis, calculate / verify liner clearances & seal clearance Calculate, Slotted Hinge Clearances and verify design basis. 23

Optimization of FCCU Expansion Joint (2-ply testable bellows monitoring) 24

Common Failure Areas of expansion joint to inspect The common failure areas are the bellows inner ply leaking. Routinely monitor testable 2-ply bellows using the test port. Bellow Attachment welds Internal liner to duct weld joint failure due to stress / vibration Loss of refractory due to mechanical & thermal reasons. 25

Common Failure Areas of expansion joint to inspect (cont d) Braid seal hose and inner pillow failure. Routinely monitor bellow temperature to watch for excessive temperature rise of bellow over time as indication of damage to pillows or braid seal. Mechanical failures due to movement surprises Hot spots and metal distortion due to excessive heating. 26

Routine Inspection of Expansion Joints during Shutdown Perform leak test for 2-ply bellows and verify sign of leak. Look for evidence of cracks on hardware and distortion of hardware such as pantographs. Perform interior inspection of refractory and liner gaps. Determine that insulation pillows are still in place. Look for evidence of bottoming out, denting of overlapping surfaces. Look for evidence of vibration. Look for evidence of hot spots, discoloration, loss of refractory. 27

Inspection of Expansion Joints during Shutdown (cont d) Inspect the refractory at the hot wall liner to cold wall refractory transition to determine if the liner weld at that point is cracked. That is a very high stress area. If needed, contact EJ Vendors such as SFI, EJS and others to perform hot & cold inspections, issue of inspection report and followup to track changes in the future. 28

Optimization, Monitoring and Life Improvement DESIGN - Avoid or Optimize Application - Design & Fabrication Upgrade - Consider Normal & SLUMP - Refractory Dry-out & Operation FABRICATION -Select Vendor Carefully - Design, Fabrication & Testing -Bellow Attachment - Refractory Installation EXPANSION JOINT OPTIMIZATION, SAFETY & OPERATIONS RELIABILITY FIELD MONITORING AND PREVENTIVE INSPECTION - Bellow Movement - Bellow Metal Temperature - Inner Ply Testing 29

www.fwc.com 30