V RM = 1500 V, I F(AV) = 0.5 A, t rr = 1.5 ns Fast Recovery Diode. Description. Package. Features. Applications

Similar documents
V RM = 7.5 kv, I F(AV) = 350 ma High-Frequency and High-Voltage Rectifier Diode. Package. Description. Features. Applications

V RM = 400 V, I F(AV) = 3.0 A, t rr = 50 ns Fast Recovery Diode. Description. Package. Features. Applications

V RM = 200 V, I F(AV) = 1.0 A, t rr = 50 ns Fast Recovery Diode. Description. Package. Features. Applications (1) (2) (1) Cathode (2) Anode

V RM = 400 V, I F(AV) = 1.5 A, t rr = 50 ns Fast Recovery Diode. Description. Package. Features. Applications (1) (2) (1) Cathode (2) Anode

V RM = 1 kv to 4 kv High Voltage Rectifier Diode. Description. Package. Features. Typical Application. Selection Guide.

1SS427 1SS Applications. 2. Packaging and Internal Circuit Rev.3.0. Start of commercial production

Schottky Barrier Diode RB168LAM150

Rectifying Diode RR1LAM6S

Rectifier Diode RR1VWM6S

Schottky Barrier Diode RBQ20BM65AFH

Rectifier Diode RR268MM-600

Schottky Barrier Diode BAT54SHMFH

BAV70HM Switching Diode (High speed switching)

UMR12N Switching Diode

New Designs. Not Recommended for. DAN222M Switching Diode (High speed switching) Data sheet. Outline V RM 80 V. I FM 300 ma. I o 100 ma.

1SS380VM Switching Diode (Low leakage)

New Designs. Not Recommended for. DA221M Switching Diode. Data sheet. Outline V RM 20 V. I FM 200 ma. I o 100 ma. I FSM 300 ma

RB521VM-40 Schottky Barrier Diode

Schottky Barrier Diode RBR10BM40A

Switching Diode BAS21VM

Schottky Barrier Diode BAT54CHMFH

Schottky Barrier Diode RBQ30TB45BHZ

Schottky Barrier Diode RBQ10BM65A

New Designs. Not Recommended for. Rectifier Diode 1SR Datasheet. Series Dimensions (Unit : mm) Land Size Figure (Unit : mm) Standard Rectifier

RB088NS100 Schottky Barrier Diode

Super Fast Recovery Diode RF601BM2D

Rectifier Diode 1SR TF

RB751VM-40 Schottky Barrier Diode

Schottky Barrier Diode RB161VAM-20

Super Fast Recovery Diode RF081M2S 1.6± ± ± ±0.1. ROHM : PMDU JEITA : SOD : Manufacture Date. Taping Dimensions (Unit : mm)

Schottky Barrier Diode RB160VAM-40

2.6± ±0.1. Taping specifications (Unit : mm) 4.0± ±0.05 φ1.55± ± ±0.1 φ1.0± Duty 0.5

RB088LAM150TF Schottky Barrier Diode

Schottky Barrier Diode RBR3LAM30A

Schottky Barrier Diode RBR3LAM60B

1SS355VMFH Switching Diode (High speed switching)

Schottky Barrier Diode RBR1LAM60A

Super Fast Recovery Diode RF05VAM2S

Rectifier Diode RR1VWM6STF

Rectifier Diode RRE02VSM6S

Schottky Barrier Diode RB550VM-40

Schottky Barrier Diode RB098BM150FH

Schottky Barrier Diode RB160VA-40

Super Fast Recovery Diode RF505BM6S

Super Fast Recovery Diode RFU02VSM6S

BAW56HM Switching Diode (High speed switching)

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM

RB060LAM-40 Schottky Barrier Diode

Average forward rectified current I O

Schottky Barrier Diode RBR5L30B

Schottky Barrier Diode BAS40-04HMFH

Super Fast Recovery Diode RF201LAM2S

Schottky Barrier Diode BAS40-05HMFH

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM

Super Fast Recovery Diode RFN2LAM6S

BAS16HM Switching Diode (High speed switching)

DA204U Switching Diode

DA204K Switching Diode

Rectifying Diode RR264M-400

SEP181404TA. LED Data Sheet - SEP181404TA

DAP202K Switching Diode (High speed switching)

New Designs. Not Recommended for. DAN202UFH Switching Diode (High speed switching) (AEC-Q101 qualified) Data sheet. Outline V RM 80 V.

New Designs. Not Recommended for. DAN222 Switching Diode (High speed switching) Data sheet. Outline V RM 80 V. I FM 300 ma. I o 100 ma.

TOSHIBA Transistor Silicon PNP Epitaxial Type (PCT Process) (Bias Resistor built-in Transistor) RN2110, RN2111

Super Fast Recovery Diode RFUS20NS6S. ROHM : LPDS JEITA : TO263S 1 Manufacture Year, Week and. Taping Dimensions (Unit : mm)

DAN217UMFH Switching Diode (High speed switching)

EMP11 Switching Diode (High speed switching)

TC4W53F/FU

Super Fast Recovery Diode RFV15TG6S

1SS400G Switching Diode (High speed switching)

Package Mounting Guide BGA

DAN217FH Switching Diode (High speed switching)

Schottky Barrier Diode RB160MM-60

UDZVFH18B Zener Diode (AEC-Q101 qualified) Outline

Reliability Tests Report

PDZV24A Zener Diode. Data sheet. Inner Circuit. P D 1000 mw. Features High reliability Small power mold type. Inner Circuit

Schottky Barrier Diode RB168MM-60

Ultra Low Capacitance ESD Protection Diode RSAC6.8CS 0.9± ±0.1. ROHM : VMN2 dot (year week factory)+ day

DTC143XCA. Datasheet. NPN 100mA 50V Digital Transistor (Bias Resistor Built-in Transistor)

BZX84C15VLFH Zener Diode

Ultra high-speed switching Voltage clamping Protection circuits Mobile communication, digital (still) cameras, PDAs and PCMCIA cards.

STZU6.2N Transient Voltage Suppressor

New Designs. Not Recommended for. RN142ZS PIN Diodes. Data sheet. Outline V R 30 V. I F 50 ma. C t 0.45 pf. rf 2.5 Ω

Transcription:

V RM = 1500 V, I F(AV) = 0.5 A, t rr = 1.5 ns Fast Recovery Diode Data Sheet Description The is a high voltage fast recovery diode of 1500 V / 0.5 A. Features V RM ----------------------------------------------------- 1500 V I F(AV) ------------------------------------------------------ 0.5 A V F --------------------------------------------------------- 2.0 V t rr1 -------------------------------------------------------- 1.5 µs Bare Leads: Pb-free (RoHS Compliant) Package Axial (φ2.7 5.0L / φ0.78) Cathode Mark (1) (2) Applications High Voltage Rectification Circuit (Bridge Circuit, etc.) (1) (2) (1) Cathode (2) Anode Not to scale -DSE Rev.1.0 SANKEN ELCTRIC CO., LTD. 1

Absolute Maximum Ratings Unless otherwise specified, T A = 25 C Parameter Symbol Rating Unit Conditions Peak Repetitive Reverse Voltage V RSM 1500 V Repetitive Reverse Voltage V RM 1500 V Average Forward Current I F(AV) 0.5 A See Figure 2 and Figure 3 Surge Forward Current I FSM 20 A Half cycle sine wave, positive side, 10 ms, 1 shot I 2 t Limiting Value I 2 t 2.0 A 2 s 1 ms t 10 ms Junction Temperature T J 40 to 150 C Storage Temperature T STG 40 to 150 C Electrical Characteristics Unless otherwise specified, T A = 25 C Forward Voltage Drop Parameter Symbol Conditions Min. Typ. Max. Unit V F, I F = 0.5 A 2.0 V T J = 100 C, I F = 0.5 A 1.5 V Reverse Leakage Current I R V R = V RM, 10 µa Reverse Leakage Current Under High Temperature Reverse Recovery Time H I R V R = V RM, T J = 100 C 200 µa t rr1 t rr2 I F = I RP = 10 ma 90% recovery point, I F = 10 ma, I RP = 20 ma, 75% recovery point, 1.5 µs 0.6 µs Thermal Resistance (1) R th(j-l) See Figure 1 17 C/W T L 10 mm Device 1.6 mm Diameter of soldering area: φ3 mm Cupper thickness: 50 µm Figure 1 Lead Temperature Measurement Conditions (1) R th (J-L) is thermal resistance between junction and lead. -DSE Rev.1.0 SANKEN ELCTRIC CO., LTD. 2

Forward Current, I F (A) Reverse Current, I R (A) Average Forward Current, I F(AV) (A) Average Forward Current, I F(AV) (A) Rating and Characteristic Curves 0.5 0.5 DC DC 0.4 t/t = 1/2 0.4 0.3 0.2 t/t = 1/3, sine wave t/t = 1/6 0.3 0.2 t/t = 1/2 t/t = 1/3 t/t = 1/6 Sine wave t T 0.0 125 130 135 140 145 150 Lead Temperature, T L ( C) Figure 2. I F(AV) vs. T L Typical Characteristics (2) (V R = 0 V) t T 0.0 120 130 140 150 Lead Temperature, T L ( C) Figure 3. I F(AV) vs. T L Typical Characteristics (2) (V R = 1500 V) 10 1.E-03 1 1.E-04 1.E-05 T J = 100 C 1.E-06 0.01 T J = 100 C 1.E-07 0.001 0.0 0.5 1.0 1.5 2.0 Forward Voltage, V F (V) 1.E-08 0 500 1000 1500 Reverse Voltage, V R (V) Figure 4. V F vs. I F Typical Characteristics Figure 5. V R vs. I R Typical Characteristics (2) See Figure 1 for the lead temperature measurement conditions. -DSE Rev.1.0 SANKEN ELCTRIC CO., LTD. 3

Physical Dimensions Axial (φ4 7.2L / φ0.78) 62.3±0.7 Φ2.7±0.2 φ0.78±0.05 5.0±0.2 NOTES: - Dimensions in millimeters - Bare leads: Pb-free (RoHS compliant) - When soldering the products, it is required to minimize the working time, within the following limits: Flow: 260 ± 5 C / 10 ± 1 s, 2 times Soldering Iron: 380 ± 10 C / 3.5 ± 0.5 s, 1 time (Soldering should be at a distance of at least 1.5 mm from the body of the product.) Marking Diagram Cathode Mark S 1 F Y M D Specific Device Code (see Table 1) Lot Number: Y is the last digit of the year of manufacture (0 to 9) M is the month of the year (1 to 9, O, N or D) D is the period of days represented by: : the first 10 days of the month (1st to 10th) : the second 10 days of the month (11th to 20th) : the last 10 11 days of the month (21st to 31st) Table 1. Specific Device Code Specific Device Code S1F Part Number -DSE Rev.1.0 SANKEN ELCTRIC CO., LTD. 4

Important Notes All data, illustrations, graphs, tables and any other information included in this document (the Information ) as to Sanken s products listed herein (the Sanken Products ) are current as of the date this document is issued. The Information is subject to any change without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative that the contents set forth in this document reflect the latest revisions before use. The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as: aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan (collectively, the Specific Applications ). Sanken assumes no liability or responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific Applications or in manner not in compliance with the instructions set forth herein. In the event of using the Sanken Products by either (i) combining other products or materials or both therewith or (ii) physically, chemically or otherwise processing or treating or both the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect or both in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate and derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken s official website in relation to derating. No anti-radioactive ray design has been adopted for the Sanken Products. The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products. Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the Information. No information in this document can be transcribed or copied or both without Sanken s prior written consent. Regarding the Information, no license, express, implied or otherwise, is granted hereby under any intellectual property rights and any other rights of Sanken. Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course of dealing or usage of trade, and (iv) as to the Information (including its accuracy, usefulness, or reliability). In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use or both of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. You must not use the Sanken Products or the Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken s distribution network. Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the Information. Please refer to our official website in relation to general instructions and directions for using the Sanken Products, and refer to the relevant specification documents in relation to particular precautions when using the Sanken Products. All rights and title in and to any specific trademark or tradename belong to Sanken and such original right holder(s). DSGN-AEZ-16003 -DSE Rev.1.0 SANKEN ELCTRIC CO., LTD. 5