HX Performance Testing

Similar documents
Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

The Paradigm Case Method of Flowmeter Selection

Feedwater Flow Measurement with Venturi and Comparison to the other Parameters in NPP Krško

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

Solar Flat Plate Thermal Collector

EPA Method 1 Field Procedures Example:

DEVELOPMENT OF THERMAL TRANSIT FLOW MEASUREMENT FOR SMALL MODULAR REACTORS

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Gary Fiselier Measurement Lead, EnCana Corporation

OTCO 12/11/13 Water Audits Meter Testing & Leaks

APlus-QMC LLC. Catalog 2017

HIGH PERFORMANCE FLOW CONDITIONERS Michael P. Saunders Savant Measurement Corporation USA

ASME PTC Flow Measurement

Pipe Flow Hydraulics

Measuring Up. Tools for High Performance Building Performance. RESNET 2008 San Diego, CA February 20, 2008 Bill Spohn. Bill Spohn, testo, inc.

Not Just a Lot of Hot Air!

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

Designing wet duct/stack systems for coal-fired plants

Flow Measurement in Large Ducts & Pipes

Effect of Twisted Tape Inserts On Heat Transfer in A Concentric Tube Heat Exchanger

Problems with Pitots. Issues with flow measurement in stacks.

Development of Measurement Method for Verification of Multi-Stage Axial Compressor with Improved Performance

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology

Downsizing a Claus Sulfur Recovery Unit

Review of Directed Inspection and Maintenance: Techniques and Technologies for Leak Detection and Quantification.

How to Calibrate an RTD or Platinum Resistance Thermometer (PRT) 2010 Fluke Corporation Presentation Title 1

REAL-TIME PUMP CONDITION MONITORING

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

Practical challenges during high temperature ultrasonic scanning

The planning and design of effective wet duct/stack systems For coal fired utility power plants

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

MATHEMATICAL MODELING OF DRYING KINETICS OF CORN IN ELECTRON FIRED FLUIDIZED BED DRYER

Multi-function VAC measuring instrument

Like piezoresistive, piezoelectric,

ABB Measurement & Analytics Flowmeter technologies

COOLING TECHNOLOGY INSTITUTE

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside.

Portable Ultrasonic Flow Meters Ultrasonic Flow Meters Handheld Ultrasonic Flowmeter Wallmounted Ultrasonic Flow Meter Explosion Proof Ultrasonic

Methane To Markets Partnership Expo October 30 to November 1, 2007 Beijing, China

Flow Meter Calibration

Experimental Analysis of Flow through Rotating Swirler with Effect of Guide Vane

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

EXPERIMENTS WITH THE THERMODYNAMIC METHOD

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

3 Steps to Better Steam Temperature Control Proven Strategies to Minimize Thermal Stress and Tube Leaks

SECTION Inline ULTRASONIC FLOW METERS

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

Effect of Vibration on Heat Transfer Enhancement in a Rectangular Channel Heat Exchanger

Capstone C O N S U L T A N T S

Universities of Leeds, Sheffield and York

ASTM Volume 03.03, October 2017 Nondestructive Testing (E94 E2373)

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

Gas Turbine Inlet Air-Conditioning Equipment

THE LEADER IN PERFORMANCE VENTILATION MEASUREMENTS

Experimental Investigation of Mixed Convection Heat Transfer from Rectangular Fin in a Horizontal Rectangular Channel

SAMPLE SPECIFICATION for CROSSHOLE SONIC LOGGING (CSL) September 2015

F Series Flow Meter F300. User Manual

EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER ENHANCEMENT BY USING POROUS TWISTED PLATE AS AN INSERT IN A FITTED TUBE

A SAGE METERING White Paper SAGE METERING 8 Harris Court, Building D1, Monterey, CA Telephone: (831)

XeteX, Inc. Residential Energy Recovery Unit

Performance Study of Solar Air Heater with Baffled Duct

MEASUREMENT OF AIRFLOW

VAC measuring instrument

Portable Infrared Flue Gas Analyzer Gasboard 3800P

Fluid Flow Conditioning. August 2015

Study of Performance Improvement of Air Conditioning using Various Heat Recovery Techniques

Experimental Facilities and Plan for a Prototype SFR

RESTORE 1030TM Testing Protocol

FLUXUS F/G601 and F/G608

RTD CHARACTERISTICS TRAINER

5. How to Select and Use the Right Temperature Sensor

Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference Large Meter Testing: Analysis and Calibration

ASME Cavitation and Multiphase Flow Forum, FED-Vol. 153, Washington, D.C., June 1993.

Bonded Neo Magnetization Guide

Laboratory Testing of Safety Relief Valves

FY01 CCACTI Annual Report

Ultra Thin Flat Heat Pipes

EEN-E1040 Measurement and Control of Energy Systems / v. 08 / TP / Flow measurement. Instructions

VERIS Accelabar. Superior Flow Measurement Accuracy

The testo 440 probe system

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

Journal of Mechanical Science and Technology 25 (8) (2011) 1961~ DOI /s

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

KEY APPLICATIONS OF FLOW COMPUTERS USED WITH MULTIPLE FLOW METER TECHNOLOGIES. Richard Gruskos Flow Products Manager Kessler Ellis Products

testo 445 Additional information at Service instrument for ventilation/air conditioning systems

EMIOTEST 3114 Gravimetric dust meter set

SANTA BARBARA COUNTY APCD GUIDANCE DOCUMENT FOR EMISSION VERIFICATION OF CONTAMINATED SOIL/GROUNDWATER CLEANUP (CSC) PROCESSES

Evaluation of Copper Stave Remnant Thickness in Blast Furnace Using Ultrasonic Method

Condenser Performance Solutions

PIOX S FLEXIM. No more corrosion and mechanical failures. Non-intrusive concentration, density and flow measurement of aggressive media

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX

VAC measuring instrument

VAC measuring instrument

Transcription:

Nuclear Division HX Performance Testing FSRUG January 26, 2016 1 February 3, 2016 2014 Curtiss-Wright

Agenda Why Heat Exchanger Performance Testing (HXPT) is required GL 89-13 Overview Typical HXPT Methodology Typical Setup Tube & Shell Plate & Frame Tube & Frame Measured vs Calculated Parameters Measurement devices HXPT OE 2 February 3, 2016 Curtiss-Wright

Why Test Generic Letter (GL) 89-13 3 February 3, 2016 Curtiss-Wright

Action 1 Reduce incidence of flow blockage problems resulting in biofouling 4 February 3, 2016 Curtiss-Wright

Action 2 Verify heat transfer capability of all S/R HXs cooled by service water 5 February 3, 2016 Curtiss-Wright

Action 3 Ensure that corrosion, erosion, protective coating failure, silting, and biofouling does not degrade the performance of the S/R systems supplied by service water 6 February 3, 2016 Curtiss-Wright

Action 4 Confirm that the service water system will perform its intended function in accordance with the licensing basis for the plant 7 February 3, 2016 Curtiss-Wright

Action 5 Confirm that maintenance practices, operating and emergency procedures and training that involve the service water system, are adequate to ensure that safety-related equipment cooled by the service water system will function as intended and that operators of this equipment will perform effectively 8 February 3, 2016 Curtiss-Wright

HXPT Methodology Development of the test plan Development of the test procedure(s) Implementation Data analysis / performance evaluation 9 February 3, 2016 Curtiss-Wright

Typical Tube & Shell HXPT Setup FM & Temp. FM & Temp. Temp. Temp. AMBIENT TEMP. & PRESSURE 10 February 3, 2016 Curtiss-Wright

Typical Plate & Frame HXPT Setup FM & Temp. AMBIENT TEMP. & PRESSURE 11 February 3, 2016 Curtiss-Wright

Measured vs Calculated Parameters (T&S and P&F) MEASURED CALCULATED Temperature both legs, Inlet and Outlet Flow both legs, Inlet or Outlet* Ambient Temperature Ambient Pressure Scaling Factor Overall Heat Transfer Coefficient Heat Transfer Rates Post LOCA Heat Transfer Rates (extrapolation) Future conditions (extrapolation) Amount of cross leakage or blockage Total fouling factor and film thickness 12 February 3, 2016 Curtiss-Wright

Typical Tube & Plate HXPT Setup Temperature, Relative Humidity, & Air Velocity FM* & Temp. Temperature & Relative Humidity AMBIENT TEMP. & PRESSURE 13 February 3, 2016 Curtiss-Wright

Air Cooled HX Measured vs Calculated Parameters MEASURED CALCULATED SW Temperature both legs, Inlet and Outlet SW Flow both legs, Inlet or Outlet* Air Temperature fixed on one end and traversed on the other Air Flow traversed (one side only) Air Relative Humidity fixed on one end and traversed on the other Ambient Pressure Ambient Temperature Scaling Factor Overall Heat Transfer Coefficient Heat Transfer Rates Post LOCA Heat Transfer Rates (extrapolation) Future conditions (extrapolation) Amount of cross leakage or blockage Total fouling factor and film thickness 14 February 3, 2016 Curtiss-Wright

Measurement Device Overview Temperature Thermocouple, RTD, Thermistors Relative Humidity Pressure Liquid Flow Ultra Sonic, Orifice Plate, BFM, SONARtrac Air Velocity Vane, Hot Wire, and 3D Ultra Sonic Anemometers, and Pitot Tube 15 February 3, 2016 Curtiss-Wright

Temperature Sensors Criteria Thermocouple RTD Thermistor Temp Range Very Wide Wide Narrow Accuracy Good Better Best Linearity Better Best Good Sensitivity Good Better Best Cost Best Good Better 16 February 3, 2016 Curtiss-Wright

Placement of Temperature Sensors (T&S and P&F) 17 February 3, 2016 Curtiss-Wright

Unacceptable Temperature Variation (T&S and P&F) 18 February 3, 2016 Curtiss-Wright

Acceptable Temperature Variation (T&S and P&F) 19 February 3, 2016 Curtiss-Wright

Temperature Variation (Air Cooled) 73 F Scenario 1 72 F 71 F 73 F Scenario 2 72 F 71 F 20 February 3, 2016 Curtiss-Wright

Thermal Stability Thermal Stability is achieved when temperature variation is less than 0.2 degf per 5 minutes (EPRI TR-107397) Often difficult to achieve stable conditions Must be planned with operations prior to testing Have Software Check all Sensors Prior to Starting the Test Visual representation of the data for ease of operation/troubleshooting Designate stable readings in Green and unstable in Red Start test when the green light is obtained 21 February 3, 2016 Curtiss-Wright

Relative Humidity & Pressure Generic RH Sensor Generic Barometers Generic Pressure Transducers 22 February 3, 2016 Curtiss-Wright

Ultrasonic Flow Meters 23 February 3, 2016 Curtiss-Wright

Ultrasonic Flow Meters Require proper entrance and exit lengths Pipe must be round and diameter and wall thickness known to obtain optimal accuracy Require good acoustic conduction through pipe wall and liners. Will not work well for pipes with cemented lining. Will have problems with fiberglass pipes Scaling, corrosion, and position have an affect on the accuracy of the flow meter Actual measurement uncertainties often exceed 5% 24 February 3, 2016 Curtiss-Wright

Ultrasonic Flow Meters Ultrasonic Transducer Ultrasonic Transducer Clear Fluids: Normal Operation Refraction of Ultrasonic Waves Reflection Scale Buildup: Loss of accuracy and eventual loss of signal Ultrasonic Transducer Scale Attenuation through Scale Signal is Attenuated or May be Lost to Transducer Entirely Scattering Losses Ultrasonic Transducer Pipe Wall Refraction Angle Change Bubbles and Solids: Ultrasonic Transducer Loss of Signal from Attenuation Results in Loss of Measurement Ultrasonic Transducer Loss of signal Liquid with Air Bubbles or Solid Particles Large Amount of Attenuation Pipe Wall 25 February 3, 2016 Curtiss-Wright

Ultrasonic Flow Meters Rotational Check 26 February 3, 2016 Curtiss-Wright

Ultra Sonic Flow Meters OE Whenever possible use redundant meters, (Inlet and Outlet) Rotational checks should always be performed Verification versus installed plant flow meters should be done when possible Always have a spare meter on hand Transducers easily damaged by impact or surface scratching 27 February 3, 2016 Curtiss-Wright

In-Line Orifice Plates Orifices require the measurement of DP across the plate Subject to scaling and erosion, resulting in loss of accuracy Often not removable for periodic calibration Proper entrance and exit lengths required for accuracy Actual measurement uncertainty may approach 5% 28 February 3, 2016 Curtiss-Wright

In-Line Orifice Plates OE Often found to be more accurate and reliable than Ultra Sonic flow meters Sometimes found to be very inaccurate Need to somehow cross-check accuracy prior to use Use portable ΔP instruments recently calibrated and properly ranged 29 February 3, 2016 Curtiss-Wright

Balanced Flow Meters Balanced flow meter technology conceived, created and tested through the Marshall Center s Technology Investment Program Licensed in August 2003, the technology was developed by NASA Originally designed for potential use in space shuttle main engines Further development made this invention suitable for commercial applications Awarded 2007 NASA/MSFC invention of the year Graftel LLC. has exclusive rights to distribute BFMs to the nuclear power industry 30 February 3, 2016 Curtiss-Wright

Balanced Flow Meters Accuracies of 0.25% of reading Accuracy unaffected by entrance and exit lengths Reduced system pressure drop and vibration Acts as both flow meter and flow conditioner Direct drop-in replacement to an orifice plate 31 February 3, 2016 Curtiss-Wright

Balanced Flow Meters Balanced flow meters may be supplied with temperature probes inserted into holes cross-drilled into them from the edges This allows for the most accurate measurement of bulk average water temperature flowing though the pipe Bulk temperature and flow rate may be measured simultaneously at the same point and time with great accuracy This allows for extremely accurate measurement of heat flux past that point 32 February 3, 2016 Curtiss-Wright

Balanced Flow Meters vs Orifice Plates 10x improvement in accuracy 100% increase in pressure recovery No need for straight pipe runs before or after the plate Extreme resistance to Scaling 15x reduction in noise energy/vibration Permanent pressure loss, accuracy and discharge coefficient comparable with a venturi meter 33 February 3, 2016 Curtiss-Wright

SONARtrac Flow Meters Clamp on meters that use the principle of sonar Up to 1% of reading accuracy Pipe coatings may be left on Effected by entrance length effects to a lessor degree than orifice plates or ultrasonic meters Pipe diameters and wall thickness are required Rotational checks are not required Increased reliability verses ultrasonic flow meters 34 February 3, 2016 Curtiss-Wright

Vane Anemometer Most commonly used instrument to measure air velocity Measures actual velocity Readings highly dependent upon distance from face and angle Accuracy not highly effected by turbulence Accurate for low flow rates 35 February 3, 2016 Curtiss-Wright

Hot Wire Anemometer Measures standard velocity Readings highly dependent upon distance from face and angle Accuracy is greatly effected by turbulence Not good for very low flow rates 36 February 3, 2016 Curtiss-Wright

Multi-Port Pitot Tube Placed in blower inlet Measures actual velocity Can be used only when all of blower s inlet air passes through the HX face being measured Good in cases when incoming the air is traveling straight along the fan s axis 37 February 3, 2016 Curtiss-Wright

3D UltraSonic Anemometer Measures both magnitude and direction of air velocity Measures standard velocity Not effected by turbulence Good for low velocity applications The only solution in cases where air flow gets turned 38 February 3, 2016 Curtiss-Wright

HXPT OE By far the biggest challenge is air velocity measurement The correct velocity instrument must be used for specific application Velocity instrument calibration conditions must match test conditions Coordination with OPS needed to insure no condensation during test Coordination with OPS needed to insure stable test conditions Real time heat balance needed to validate results while testing Pretest analysis required to determine optimum system conditions to maximize resolution Straight pipe runs to measure flow 39 February 3, 2016 Curtiss-Wright

RX Cooler HXPT 40 February 3, 2016 Curtiss-Wright

Questions? Thank you Questions? 41 February 3, 2016 Curtiss-Wright

Rich Heibel Product Manager rheibel@curtisswright.com 619-952-1048 Joseph Rosca Product Manager Graftel Products jrosca@curtisswright.com 714-220-8484 www.cwnuclear.com 42 February 3, 2016 Curtiss-Wright