Using Empower SystemsQT Qualification Tool

Similar documents
ENSURING QUALITY THROUGH COMPLIANCE [ COMPLIANCE ]

Qualification of High-Performance Liquid Chromatography Systems

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

According to USP <1058>

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

The procurement, qualification and calibration of lab instruments: An Overview

Services for Regulated Bioanalysis System Solution June 2012

Validation Strategies for Equipment from Multiple Vendors

ACQUITY Arc VERSATILITY WITHOUT COMPROMISE

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Validation Strategies for Equipment from Multiple Vendors

Welcome into a New World of Chromatography. Karima BAUDIN Oct 2015

Qualification of UPLC system IRequest UPLC Community Tips & tricks Waters Corporation 1

2018 by Agilent Technologies Agilent CrossLab Compliance Services

Analytical HPLC solutions

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

[ ALLIANCE HPLC SYSTEM ]

Empower Driven Services Resource Management Report

Performance characteristics of the 1260 Infinity Quaternary LC system

Agilent Infinity LC Instrument Component Software Version 1.0 for Empower Software

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Optimize Your Process Operations by Improving Process Monitoring

á1058ñ ANALYTICAL INSTRUMENT QUALIFICATION

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

Lessons from Pharmaceutical Laboratory related FDA Warning Letters

UNIFI 1.5 : Simplifying Qualification and Validation June 2012

ICH Q2(R1) A Primer. cgmp. GxP PIC/S SOP ISO QA/QC LOD/LOQ. Validation of Analytical Methods API EP FDA OECD GCP

ACQUITY Arc TM System

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

CHEMICAL SOLUTIONS, Inc.

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

ALLIANCE SYSTEM FOR CARBAMATE ANALYSIS

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

á1058ñ ANALYTICAL INSTRUMENT QUALIFICATION

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Waters QUATTRO PREMIER XE

Fusion Analytical Method Validation

FUTURE-PROOF SOLUTIONS FOR REGULATED LABORATORIES IN THE FACE OF CHANGING USP <621> GUIDELINES

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

QUANLYNX APPLICATION MANAGER

Spectroscopy Solutions for Pharmaceuticals:

WHO SAYS COMPLIANCE NEEDS TO BE COMPLICATED?

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

Strategies for Risk Based Validation of Laboratory Systems

Altus UPLC IT S ALL ABOUT PEAK PERFORMANCE

Patricia McConville Manager Product Positioning Laboratory. Next Generation Instrument Design

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

The Impact of Spare Parts. Performance

[ WHITE PAPER ] A Basic Overview: Meeting the PIC/S Requirements for a Computerized System INTRODUCTION GOOD MANUFACTURING PRACTICES

Welcome to our E-Seminar: Automation Tools for Efficient Result Review According to GMP

EKSIGENT EKSPERT ULTRALC SYSTEMS. UHPLC designed for mass spectrometry

Performance Maintenance Protocol

[ ANALYTICAL SERVICES SOLUTIONS ] constant DEADLINES... FASTER THAN EVER BEFORE.

HPLC 920-LC ANALY TIC AL LIQUID CHROMATOGR APHY SOLUTIONS.

Team L5 Automation Practices in Large Molecule Bioanalysis

of peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry

Techniques for Improving the Efficiency of Large Volume Loading in Preparative Liquid Chromatography

HPLC 940-LC ANALY TIC AL TO PREPARATIVE LIQUID CHROMATOGRAPHY SOLUTIONS.

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

CRITICAL ASPECT ANALYTICAL TEST REVIEW

Agilent 1260 Infinity LC & LC/MS Purification Systems. Purify your way

Integrated IC Systems Installation Qualification Dionex Corporation

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

Agilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY

2017 by Agilent Technologies Agilent CrossLab Compliance Services

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION

Compliance and qualification services. Trust your validation needs to the people who design, build, test, and support your systems

Online UPLC Method for the Support of Cleaning Validation and the Routine Monitoring of Cleaning Procedures

2017 by Agilent Technologies Agilent CrossLab Compliance Services

Agilent 8453 Spectrophotometer and UV-visible ChemStation for Dissolution Testing. Solution Bundles for automated Dissolution Testing

At Your ServIce. Microbiology Services. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada.

MB3600. Versatile FT-NIR analyzer designed for your industry. The most reliable FT-NIR specifically designed for QA / QC.

Regulatory Expectations, Standards & Guidelines

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

2018 by Agilent Technologies Agilent CrossLab Compliance Services

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

AQUALAB 4TE, 4TEV, 4TE DUO, 4TEV DUO BENCHTOP WATER ACTIVITY

Cleaning Validation PRODUCT OVERVIEW

Fusion Analytical Method Validation

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082C

MassPREP On-Line Desalting Cartridge

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

[ MARKET SOLUTION ] Chromatography Data System Solutions for the Agrochemical Industry

CX-1 ph Gradient Buffer

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082D

2018 by Agilent Technologies Agilent CrossLab Compliance Services

PESTICIDE SCREENING APPLICATION SOLUTION

March Harmonization of Standards for Better Regulatory Compliance

The Leading Solution for Method Validation VALIDAT

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

QIAGEN Service Solutions Professional Services

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

á1225ñ VALIDATION OF COMPENDIAL PROCEDURES

Transcription:

Using Empower SystemsQT Qualification Tool for Waters Modular HPLC Systems A summary of Empower SystemsQT Qualification Tool features and benefits, with emphasis on the technical attributes of the qualification tests.

GxP 1 Compliance Regulatory agencies continue to require documented evidence (electronic and written) that responsible companies and persons can consistently generate quality products with supporting analytical data. Analytical systems have become more automated and generate analytical data that is managed by sophisticated software programs. While automated analytical systems require less operator involvement to produce data, it is worth noting that routine involvement of a designated responsible person(s) to ensure continued system performance is still required. Regulated companies are constantly balancing expenses to maximize shareholder value as well meeting product quality and regulatory compliance requirements. The constant quest for reduced expenses may target analytical system qualification (performance verification) and maintenance as means to decrease laboratory operating costs. Short cuts in such areas can result in erosion of system performance with accompanying analysis and product errors which may result in regulatory compliance problems and loss of corporate reputation. To assist customers in meeting their regulatory requirements as well as meeting laboratory throughput and system uptime objectives, Waters has created an extensive portfolio of regulatory compliance products and services. Empower Software system qualification (SystemsQT) tools, chemical test solutions kits, qualification workbooks, and Global Services are all focused on ensuring customer success. The Evolution of Chromatography System Qualification As HPLC and now UPLC and LCMS systems evolve into highly automated, computer software controlled systems, so too is the need to verify performance in an as used system configuration. With the growing acceptance of Waters Empower Software as the preferred chromatography laboratory platform, adding systems qualification capability extends its value and benefits to GxP regulated laboratories. Qualification data and records are still required for fully automated systems but qualification processes have needed to evolve to meet these new challenges. Throughout all the evolutionary changes to system qualification processes, the roles of the involved participants have remained constant. n Company (System owner) management is still responsible for the overall use, operation and integrity of analytical systems and generated analytical data. During the process of qualifying analytical systems for use in a GxP regulated environment, owner management (Approver) is responsible for designating a qualified company individual to oversee qualification processes (Reviewer) as well as approve qualification results and the qualification Performer. n The Reviewer is responsible for ensuring the Performer follows the company approved protocols and has completed all maintenance, qualification testing, and documentation. n The Performer is a trained and owner management approved system maintenance and qualification services specialist who can successfully complete all required qualification processes. Traditional Paper-Based Qualification Processes Tied to the evolution of chromatographic systems, Waters qualification services has kept pace with the production of Qualification Workbooks, chemical test kits, and software qualification tools. Paper-based qualification processes, while being used successfully for many years, share many of the same problems as do manual system control and data acquisition processes. 1. Paper records present archival challenges: storage logistics, record management, and record retrieval/access issues. 2. Risk of human error in testing, calculations, and documentation. 3. Metrology-type testing of modules in a non- as-used configuration. When non-automated HPLC systems were comprised of individually programmed and controlled modules, there was a need to verify the performance of each individual component. Individual component performance verification, in terms of accuracy and linearity is called OQ or Operational Qualification. Following the successful completion of module OQs, the total system performance is verified in terms of precision as vendor Performance Qualification (PQ). 2

Please Note While paper-based qualification processes have issues, there are and will be instances when such processes are required to complete system qualification. With the addition of specialized detectors to UPLC and HPLC systems as well the continued requirement of metrology-type testing of some physical parameters for automated systems, a paper or electronic workbook-based process may be required to supplement automated qualification processes. Automated HPLC and UPLC Systems Qualification Older, automated HPLC systems can continue to utilize paper-based qualification processes. But in light of today s laboratory regulatory and efficiency challenges, automated system qualification tools are receiving much more focus and acceptance. Waters Empower SystemsQT Features and Benefits 1. Built-in option to a validated chromatography control and data system, which is switched on as required, not a thirdparty program. 2. Eliminates most manual calculations and decisions to reduce human error opportunities as well as provide much faster system testing. 3. Qualification processes can be managed as electronic records. 4. All system control, data collection (acquisition, processing, reporting, archiving) are auditable. 5. Uses validated chromatographic methods to test and verify total system performance. 6. Designed to provide means to integrate metrology-type test methods where required. The Waters Compliance Specialist will transfer DVD-based manual test protocols to a customer s location of choice. Typically such manual tests are run and documented before running the automated Empower SystemsQT tests. 7. Waters Compliance Specialists are trained and certified to perform all system testing, maintenance, and documentation for both traditional workbook-based processes and for Empower SystemsQT automated qualification. 3

Empower SystemsQT Qualification Tool versus Paper Workbook-Based Qualification Processes Responsible Person Qualification Performer Approval / sign-off process Qualification documents Qualification test chemicals Calibrated test equipment New system Installation Qualification (IQ) Empower SystemsQT Processes Owner management designated responsible approver. Trained, certified and owner management approved qualification and system service expert. Electronic record or summary page print out sign-off. Empower / Empower 2 software validated projects. Waters Compliance Specialist (Performer) provides DVD-based projects and documents as required for testing. Storage binder supplied for hard copy sign-off sheets. Ready-to-use, certified test chemicals in accordance with sample manager loading instructions. As required, calibrated measurement devices provided by Waters Compliance Specialist (Performer). Empower / Empower 2 Acquisition Node provides system configuration for inserting serial number, location, purchase information for either electronic record sign-off or print out for manual sign-off and binder insertion. Paper Workbook Processes Same Same Performer initials and dates each results page. Approver signs and dates summary page. Comprehensive workbook containing IQ, OQ, PQ and maintenance instructions, procedures, results logs and sign-off pages for each system module. Storage binder supplied for workbook archiving. Ready-to-use, certified test chemicals to be manually used in accordance with workbook instructions. As required, calibrated measurement devices provided by Waters Compliance Specialist (Performer). Performer written insertion of system configuration, serial numbers, location, purchase information with initials and dates on workbook form pages. Operational Qualification (OQ) and system Performance Qualification (PQ) If required, (for specialized detector and physical parameter testing), load DVD-based protocols and follow instructions for manual procedures. For system testing, select Empower qualification project, follow system preparation instructions, load test chemicals in specified sample manager locations and run automated qualification tests. SystemsQT will analyze chromatographic results and, through the use of Boolean custom fields, provide a pass/fail decision for all test parameters. Reviewer approves qualification results. Performer and Reviewer sign-off either electronic record or hard copy of summary report. Performer follows workbook instructions and procedures for test chemical preparation, test equipment use, individual module testing, system preparation, and total system testing. Performer makes pass/fail decisions for all tests, signs and dates all result forms, and has Reviewer approve and signs-off completed document. Completed workbook chapters are inserted into storage binder. Failed Test Result Process Pre-OQ & PQ Maintenance Processes Archiving System Qualification & Maintenance Records Hard-copy sign-off sheets filed in supplied storage binder. SystemsQT will identify failed test. Performer will then investigate system problem, either provide repair(s) or, more likely, ensure system passes all performance diagnostics and re-run test injections and failed qualification test. Performer will log required maintenance. For existing systems, maintenance must be performed prior to running system qualification. Recommended maintenance procedures are DVD- based and are electronically transferred to owner s management location of choice. Maintenance information report is inserted into qualification binder. System qualification and maintenance records should be stored in a safe place that makes them easily available for inspection. SystemsQT records can be stored as electronic records or as hard copy signed-off summary reports that can be stored in the supplied binder. Empower search capabilities can be used to locate records easily. Performer will stop module /system testing when an individual test fails. Performer will then investigate system problem, either provide repair(s) or, more likely, ensure system passes all performance diagnostics and re-run failed qualification test. The performer will then continue qualification testing. Performer will log required maintenance. For existing systems, maintenance must be performed prior to running system qualification. Individual maintenance chapters are supplied with each module s qualification workbook. Maintenance information report is inserted into qualification binder. System qualification and maintenance records should be stored in a safe place that makes them easily available for inspection. Completed and signed-off workbooks can be stored in the supplied binder. 4

Empower SystemsQT Pass / Fail Processes For automated system qualification, SystemsQT employs the appropriate sample sets in Empower Software to acquire data in Run Samples. Appropriate statistical analysis is applied to the results to provide standard deviation, %RSD, R 2 linearity etc. results. Custom Boolean Fields are applied to the final results to determine test pass or fail. Non-Standard System Qualification Tests and Processes The development of Waters Global Compliance Services and Products included reviews and input by key experts in the USA Department of Health and Human Services (US FDA) inspection branch, international Ministries of Health experts, internationally recognized experts in CGMP / GLP validation as well as global pharmaceutical, cosmetic, and food regulatory compliance groups. Customers using Waters regulatory compliance products (workbooks and SystemsQT) have been achieving successful system audits for over fifteen years. The portfolio of qualification tests utilized by Waters is designed to meet or exceed all regulatory agency requirements. Testing of parameters that are connected to a specific analytical method and not the analytical system are not included in Waters qualification processes. If custom qualification tests and services are required, please contact your local Waters service management team or Global Compliance Services Marketing. Qualification of 1525/1525µ HPLC Pump and 2707 Autosampler Systems with 2489 or 2998 Detector using Empower SystemsQT Qualification Tool A 1525/2707 System includes: A 1525 Binary HPLC pump or a 1525µ Micro Binary HPLC Pump with a 2707 temperature controlled autosampler plus detector option which can be: n A 2489 Tunable UV/Visible (TUV) Dual Wavelength Detector or a 2998 Photodiode Array (PDA) Detector Plus other system options that can include: n A 1500 series column heater 5

Empower SystemsQT processes for qualifying a 1525 / 2707 HPLC System with a UV Detector are as follows: Manual OQ Tests Performed before running Automated SystemsQT Tests OQ Tests From SystemsQT Projects/Documentation DVD 1. Autosampler Temperature Accuracy. 2 Column Heater Temperature Accuracy. OQ Test Methods 1. Temperature verified using calibrated temperature probe. 2. Temperature verified using calibrated temperature probe. System Preparedness Test 1525, 2707 UV OQ & PQ Tests 1. Test Injections These are not considered part of the qualification test suite. Automated OQ & PQ Tests Running Empower Project Sample Sets 1. System Precision Test. 2. (A) PDA detector wavelength accuracy test. (B) TUV detector wavelength accuracy test. 3. Carryover test. 4. Detector linearity and sensitivity test. 5. Injector linearity and accuracy test. 6. Flow rate linearity and accuracy test. 7. Sample positioning test. 1. Replicate test sample injections to verify system is equilibrated and ready to commence. OQ & PQ Test Methods 1. System precision (standard deviation and %RSD of peak retention times, peak areas, and heights) is verified by making replicate injections of test sample. 2. (A) Wavelength accuracy is determined by scanning spectra and verifying lambda maximums of well characterized compound falls within specifications. (B) Wavelength accuracy is determined by the wavelength of the highest peak from several injections of well characterized compound. 3. Sample carryover is determined by running blank injections following an injection of a concentrated sample. 4. Detector linearity is determined by using a fixed injection volume of varying sample concentrations to generate a plot of peak height and area versus sample amount. Sensitivity is determined by dividing peak height and area by sample amount. Pass/fail is based on R 2 of the plot and %RSD of sensitivity values. 5. Verifying a linear response from variable injection volumes of a fixed sample concentration. Accuracy is determined from x intercept of injection volume plot. 6. Flow rate linearity is determined by plotting the inverse of peak retention time versus the flow rates. Flow rate accuracy is determined from the X intercept of the plot. 7. Successful completion of all of the above tests signifies proper sample positioning capabilities. Qualification of1525/1525µ HPLC Pump and 2707 Autosampler Systems with a 2414, 2410, 410 or 2475 Detector using Empower SystemsQT Qualification Tool A 1525/2707 System includes: A 1525 Binary HPLC pump or a 1525µ Micro Binary HPLC Pump with a 2707 temperature controlled autosampler plus detector option which can be: n A 2414, 2410, or 410 Refractive Index (RI) Detector or a 2475 Fluorescence (FL) Detector Plus other system option that can include: n A 1500 series Column Heater 6

Empower SystemsQT processes for qualifying a 1525 / 2707 HPLC System with a RI or FL Detector are as follows: Manual OQ Tests Performed before running Automated SystemsQT Tests System Start Up (RI Detector Only) System Preparedness Test 1525, 2707 RI OQ & PQ Tests 1525, 2707 FL OQ & PQ Tests OQ Tests From SystemsQT Projects/ Documentation DVD 1. Flow rate accuracy (1525/ 2475 systems). 2. Autosampler temperature accuracy. 3. Column heater temperature accuracy. 4. Wavelength calibration (2475 only). 5. Emission units normalization (2475 only). 6. Raman signal-to-noise (2475 only). 1. Sample set that purges injector and RI detector and equilibrates system. 1. Test Injections These are not considered part of the qualification test suite. Automated OQ & PQ Tests Running Empower Project Sample Sets 1. System Precision Test. 2. RI detector sensitivity test. 3. RI detector linearity and plate positioning test. 4. Injector linearity and accuracy tests. 5. Flow rate linearity and accuracy test. Automated OQ & PQ Tests Running Empower Project Sample Sets 1. System Precision Test 2. Emission wavelength accuracy test. 3. Excitation wavelength accuracy test. 4. Carryover test. 5. Linearity, sensitivity, and plate positioning test. 6. Gain linearity test. OQ Test Methods 1. Flow rate accuracy verified by timing collection of fixed volume. 2. Temperature verified using calibrated thermometer. 3. Temperature verified using calibrated thermometer. 4. Calibrates detector wavelengths to internal erbium filter wavelengths. 5. Sets a common detector sensitivity based on Raman water band energy. 6. Uses Raman water band light scattering reading to verify signal-to-noise is within specifications. 1. Purges and equilibrates system. 1. Replicate test sample injections to verify system is equilibrated and ready to commence. OQ & PQ Test Methods 1. System precision (standard deviation and %RSD of peak retention times, peak areas and heights) is verified by making replicate injections of test sample. 2. Sensitivity is determined by injecting fixed injection volumes at different sensitivity settings and dividing the peak area by the sensitivity setting. 3. Determines that response is linear within the specified range. Fixed injection volumes of different concentrations of test sample, provides the coefficient (r 2 ) of detector response versus sample amount. Proper function of autosampler plate positioning is verified during linearity test by injecting from vials in different plate locations. 4. Verifying a linear response from variable injection volumes of a fixed sample concentration. Accuracy is determined from x intercept of injection volume plot. 5. Flow rate linearity is determined by plotting the inverse of peak retention time versus the flow rates. Flow rate accuracy is determined from the X intercept of the plot. OQ & PQ Test Methods 1. System precision (standard deviation and %RSD of peak retention times, peak areas and heights) is verified by making replicate injections of test sample. 2. Emission wavelength accuracy, is verified by determining that the lambda maximum of test sample peak falls within specifications. 3. Excitation wavelength accuracy, is verified by determining that the lambda maximum of test sample peak falls within specifications. 4. Sample carryover is determined by running blank injections following an injection of a concentrated sample. 5. Detector linearity is determined by using a fixed injection volume of varying sample concentrations to generate a plot of peak height and area versus sample amount. Sensitivity is determined by dividing peak height and area by sample amount. Pass/fail is based on R 2 of the plot and %RSD of sensitivity values. Proper function of autosampler plate positioning is verified during linearity test by injecting from vials in different plate locations. 6. To verify detector gain linearity performance, replicate injections of fixed volume and concentrations are run at different gain settings and plotted. Gain sensitivity is determined by dividing peak area/height by the gain amount. Pass/fail is based on %RSD of gain sensitivity values. 7

References 1. GxP refers to all government required good laboratory operating practices including, Current Good Laboratory Practices (CGLP), Current Good Manufacturing Practices (CGMP), Current Good Automated Laboratory Practices (CGALP), Current Good Clinical Practices (CGCP) as well as other regulatory agency required practices. Waters and UPLC are registered trademarks and Empower, SystemsQT, and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2010 Waters Corporation. Produced in the U.S.A. May 2010 720003402EN AG-AP Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com