Agilent Anion-Exchange Media for Proteins

Similar documents
Agilent PL-SAX Anion-Exchange Media for Nucleotide and Oligonucleotide Analysis

Fast Agilent HPLC for Large Biomolecules

Faster Separations Using Agilent Weak Cation Exchange Columns

Agilent Ion-Exchange BioHPLC Columns CHARACTERIZE CHARGED VARIANTS OF PROTEINS WITH SPEED AND CONFIDENCE

Purification of oligonucleotides by anion exchange chromatography

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Phenyl Membrane Adsorber for Bioprocessing

columns P r o P a c H I C C o l u m n S o l u t i o n s f o r P r o t e i n A n a l y s i s

Phenyl Membrane Adsorber for Bioprocessing

BabyBio S BabyBio Q BabyBio DEAE

Biomolecule Purification. Purification columns and media for peptides, oligonucleotides, and proteins

TSK-GEL BioAssist Series Ion Exchange Columns

Fast protein separations with ion exchange columns

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

ION EXCHANGE KIT FOR MAB SEPARATIONS

Red Sepharose CL-6B INSTRUCTIONS

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

TOYOPEARL GigaCap Series

1. Bloomsbury BBSRC Centre for Structural Biology, Birkbeck College and University College London.

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

ProSEC 300S. Protein Characterization columns

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

Selecting the Correct Agilent PLgel Column for Polyolefin Analysis with GPC/SEC

TSKgel STAT Columns for High Performance Ion Exchange Chromatography

SOURCE 15Q, SOURCE 15S, and prepacked column formats

Dynamic High Capacity Mustang Q Membrane Units for Scaleable Anion Exchange Chromatography Purification of Adenoviral Vectors

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Isolation of Protein

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Chapter 1 Principles of ion exchange

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

WorkBeads Protein A INSTRUCTIONS IN

BioPro SmartSep. Benefits of using BioPro SmartSep. Product information

Column for High Performance,High-Binding Capacity Ion Exchange Chromatography:TSKgel SuperQ-5PW and Its Applications

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

High-Resolution Analysis and Purification of Oligonucleotides with the DNAPac PA-100 Column

G Trap Ion Exchange Selection Kit

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Optimizing Protein Separations with Agilent Weak Cation-Exchange Columns

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

The above media is designed to purify antibodies from aggregates and other impurities.

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Analysis of biomolecules by SEC and Ion-Exchange UPLC

TOSOH FACT The Tosoh logo symbolizes the corporate philosophy of Tosoh s vision of the ideal. The curved lines represent the realization of

Ion exchange chromatography

Blue Sepharose CL-6B. instructions

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Efficient Multi-Well Protein Purification Strategies

2 Liquid chromatography of biomolecules

Size Exclusion Chromatography

The practical task of monoclonal IgG purification with CHT TM ceramic hydroxyapatite

G Sep Size Exclusion Columns

ProteoEnrich CAT-X SEC Kit Merck: Lichrospher Composition. Silica Particle size. 25 µm particles with 6 nm pore size Ligand SO 3

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Protein Techniques 1 APPENDIX TO CHAPTER 5

SUPPLEMENTARY MATERIAL

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

Purification Polishing of His-tagged proteins

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

PATfix TM. Lead the way of your process

Size Exclusion BioHPLC Columns

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Data File. HiLoad Superdex 30 prep grade HiLoad Superdex 75 prep grade HiLoad Superdex 200 prep grade. Pre-packed gel filtration columns

Charge Variant Analysis

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

AFFINITY HIS-TAG PURIFICATION

DNAPac PA200 and PA200 RS Columns Solutions for Nucleic Acid Analysis

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

6 Purification and characterization of L- Asparaginase

Chromatography column for therapeutic protein analysis

Bio-Monolith Protein G Column - More Options for mab Titer Determination

High Performance Polymer Chromatography Products

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

G-Sep Ion Exchange Agarose Fast Flow

G-Sep Ion Exchange Agarose Fast Flow

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

(Refer Slide Time: 00:16)

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension.

Application Note. Authors. Abstract. Biopharmaceuticals

Superdex 200 HR 10/30 INSTRUCTIONS

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

1. Connect the column to the chromatography system, syringe or pump.

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

MBP Excellose handbook - Purification of MBP fusion proteins -

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

AFFINITY HIS-TAG PURIFICATION

Operating Instructions

AFFINITY HIS-TAG PURIFICATION

Capture of mouse monoclonal antibodies

4/4/2013. BioHPLC columns. Paul Dinsmoor Biocolumn Technical Specialist. April 23-25, Size Exclusion BioHPLC Columns

Ion Exchange Chromatography. Learning Objectives:

Q and S HyperCel Sorbents

GE Healthcare. Gel Filtration. Principles and Methods

TOSOH BIOSCIENCE. Hydrophobic Interaction Chromatography. How hydrophobic do you want to go? Separations Business Unit

ProSwift and PepSwift Monolith Columns for Biomolecule Analysis

Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION

The above media is designed to capture antibodies or other molecules of similar size.

Userguide: SepFast Gel Filtration columns

Transcription:

Agilent Anion-Exchange Media for Proteins Technical Overview Introduction Agilent PL-SAX combines rigid macroporous polystyrene/divinylbenzene (PS/DVB) polymer matrix and chemically stable quaternized polyethyleneimine coating that allows the analysis of biomolecules over a wide range of mobile phase conditions and ph. The physical stability of the media permits their use with high eluent flow rates and high speed gradients for very rapid separations. The excellent stability of PL-SAX ensures rapid equilibration between separations using aggressive cleanup procedures employing high salt, NaOH, mineral and organic acids, and a wide range of organic solvents. Some examples of the use of PL-SAX, with 1000Å and 4000Å pore sizes, are given here.

Fast protein fingerprinting of snake venoms on PL-SAX 1000Å The characterization of elution profiles of complex aqueous biological matrices such as snake venom is accomplished in minutes using the open pore structure of PL-SAX columns. Sample preparation of venom often involves only dilution and filtration. These crude samples from the monocellate (Thailand) cobra (Naja naja kaouthia) (Figure 1) and western diamondback rattlesnake (Crotalus atrox) (Figure 2) were chromatographed to produce very distinct protein elution profiles. It is possible using this 4 gradient to fractionate the sample and identify biologically active components in each of the venom samples. Eluent A: 0.01 M Tris HCI, ph 8 Eluent B: A + 0.35 M NaCl, ph 8 Gradient: Linear 0-100% B in 4 Flow Rate: 1 ml/min The venom samples were diluted with Eluent A and filtered prior to the analysis. 30 Figure 1. Raw data chromatogram of a cobra venom on Agilent PL-SAX 1000Å. 2

30 Figure 2. Raw data chromatogram of a rattlesnake venom on Agilent PL-SAX 1000Å. 3

Basic proteins The quaternary amine functionality and ph stability of the PL-SAX adsorbent enables anion-exchange separations to be carried out at high ph. For the analysis of trypsinogen (pl 9.3) and α-chymotrypsinogen (pl 8.3), an eluent ph of 11 is used to ensure that the trypsinogen has a net negative charge. Eluent A: 0.01 M Tris HCI, ph 11 Eluent B: A + 0.35 M NaCl, ph 11 Gradient: Linear 0-100% B in 2 Flow Rate: 1.0 ml/min Peak Identification 1. Trypsinogen 2. α-chymotrypsinogen 1 2 20 Figure 3. Analysis of trypsinogen and α-chymotrypsinogen on Agilent PL-SAX 1000Å. 4

Gastric juice pepsins The strong ion-exchange functionality PL-SAX is ideally suited to the analysis of gastric juices at low ph. In this trial, 250 µl of gastric juice was dialyzed against 0.05 M sodium acetate at ph 4.1 and passed through a 0.45 µm filter. Pepsins 1, 5, 3a, 3b and 3c were well resolved for the identification of peptic ulcer disease in clinical research. Eluent A: Sodium acetate, ph 4.1 Eluent B: A + 1 M NaCl Flow Rate: 1.0 ml/min 3b %B 100 5 3c 3b 1 0 40 Figure 4. Analysis of gastric juice Agilent PL-SAX 1000Å (separation courtesy of N B Roberts, Royal Liverpool Hospital, UK). 5

Maintaining the bioactivity of ß-galactosidase Ion-exchange uses aqueous eluents and so is considered a technique that does not denature proteins. PL-SAX is used to purify enzymes when it is a requirement to maintain the biological activity of enzymes such as ß-galactosidase. Partially purified ß-galactosidase from Escherichia coli was dialyzed against eluent A overnight, prior to analysis. Eluent A: 0.01 M Tris HCI, ph 7.5 Eluent B: A + 1 M NaCl, ph 7.5 Gradient: Linear 0-100% B in 4 Flow Rate: 1.0 ml/min Figure 5. Analysis of ß-galactosidase on Agilent PL-SAX 1000Å (separation courtesy of Mary Anne Rounds, Purdue University, USA). 36 6

Analysis of liver cytosol For the analysis of cytosol from liver, 10 g of tissue was homogenized with 50 ml buffer and centrifuged at 100,000 g to separate the membrane proteins from the cytosol (the portion containing the water soluble proteins). The cytosol contained 57 mg/ml protein by Bradford Assay and 0.15 M NaCl, and was diluted with water (1:9) and passed through a 0.45 µm syringe filter. Eluent A: 0.01 M Tris HCI, ph 8 Eluent B: A + 0.5 M NaCl, ph 8 Gradient: Linear 0-40% B in 3 Flow Rate: 0.01 ml/min Figure 6. Raw data chromatogram of liver cytosol on Agilent PL-SAX 1000Å (separation courtesy of Mary Ann Rounds, Purdue University, USA). 30 7

Analysis of choline kinase on PL-SAX 4000Å PL-SAX 4000Å material has an open pore structure for high resolution and high speed applications or for the separation of very large molecules. The capability of the media is evident in the analysis of choline kinase. A sample of 75 ml of partially purified choline kinase from a liver cytosol contained approximately 1 mg of the enzyme at molecular weight 160,000. Column: PL-SAX 4000Å 8 µm, 50 x 4.6 mm (p/n PL1551-1803) Eluent A: 20 mm Tris 5% ethylene glycol, ph 7.5 1.0 mm Ethylene glycol tetraacetic acid } required to retain 2.0 mm ß-Mercaptoethanol } enzyme activity 0.2 mm Phenylmethylsulfonyl fluoride } Eluent B: A + 1 M KCI Flow Rate: 3.0 ml/min %B 100 enzyme activity Figure 7. Raw data chromatogram of liver choline kinase Agilent PL-SAX 4000Å (separation courtesy of T Porter, Purdue University, USA). 0 40 8

Agilent PL-SAX Strong Anion-Exchange Columns PL-SAX is designed for anion-exchange HPLC separations of proteins and deprotected synthetic oligonucleotides under denaturing conditions. The strong anion-exchange functionality, covalently linked to a chemically stable polymer, extends the operating ph range. What s more, anion-exchange capacity is independent of ph. These data represent typical results. For further information, contact your local Agilent Sales Office. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 2011 Published in UK, August 9, 2011 5990-8778EN