Differential Scanning Calorimetry DSC 3500 Sirius

Similar documents
Differential Scanning Calorimetry DSC 200 F3

Analyzing & Testing. DSC 214 Polyma. Surprisingly Easy The New All-Inclusive Product Package for DSC

Analyzing & Testing. DSC 214 Polyma. Surprisingly Easy The New All-Inclusive Product Package for DSC

Analyzing & Testing. DSC 214 Polyma. Surprisingly Easy The New All-Inclusive Product Package for DSC

Analyzing & Testing. Thermogravimetric Analysis TGA. Method, Technique, Applications

Differential Scanning Calorimetry DSC 214 Polyma

Analyzing & Testing. Differential Scanning Calorimetry. Method, Technique, Applications DSC 204 F1. Leading Thermal Analysis

Differential Scanning Calorimetry DSC 404 F3

Simultaneous Thermal Analyzer STA 449 F5 Jupiter

Differential Scanning Calorimetry DSC 404 F1/F3 Pegasus

DSC limit of detection: < 0.1 µw (depending upon the sensor) System time constant: 0.6 s to 3 s (depending upon the sensor)

Differential Scanning Calorimetry DSC 404 F1

Simultaneous Thermal Analysis STA 2500 Regulus

STA 2500 Regulus Simultaneous Thermal Analysis

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

DIL 402 CD Double/Differential Dilatometer

Heat Flow Meter HFM 436 Lambda. Analyzing & Testing

i Series Thermal Analysis Systems

H N CH 3. Investigation of Pharmaceuticals, Foods and Cosmetics with the NETZSCH Nevio Instrument Series

Analyzing & Testing. Laser Flash Apparatus LFA 457 MicroFlash. Method, Technique, Applications of Thermal Diffusivity and Thermal Conductivity LFA 457

DIFFERENTIAL SCANNING CALORIMETER DSC PT 1000

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETERS

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

Thermal Analysis Premium DSC 3+ STAR e System Innovative Technology Versatile Modularity Swiss Quality

Collected Applications Thermal Analysis ELASTOMERS. Volume C

Thermal Analysis Excellence

THERMAL DIFFUSIVITY THERMAL CONDUCTIVITY

Guarded Hot Plate GHP 456 Titan and GHP 456 HT Titan. Method, Instrumentation, Applications Analyzing & Testing

T H E R M A L A N A L Y S I S

Thermal Analysis Excellence

Accessories for Differential Scanning Calorimeters and Thermobalances

Thermal Diffusivity - Thermal Conductivity LFA 447

Instructions for using the PerkinElmer DSC-8500

Light Flash Apparatus LFA 467 HyperFlash Series. Method, Technique, Applications of Thermal Diffusivity and Thermal Conductivity

Nova Geração de Instrumentos de Análise Térmica

Differential Scanning Calorimeter. DSC-60 Plus Series C160-E013A

ISO INTERNATIONAL STANDARD

High Heating Rate DSC

DMA 242 E. Dynamic Mechanical Analysis. Method, Technique, Applications

Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature and glass transition step height

Introduction. From the combination of TG and DTA or HDSC one receives a broad range of information, such as:

Dilatometer Series DIL 402 Expedis Select and Supreme. Method, Instruments, Applications

Standard Test Method for Transition Temperatures of Polymers By Differential Scanning Calorimetry 1

Dilatometer L 76 L 75 Horizontal L 75 Vertical

Thermal Analysis Excellence

Application Data Book

Analyzing & Testing. Laser Flash Analysis _ LFA Method, Technique, Applications. LFA C to 2800 C. Leading Thermal Analysis

exceptional DesiGn enhanced performance DMA 8000 Dynamic Mechanical Analyzer

THERMAL ENERGY STORAGE SYSTEMS STEARIC / LAURIC ACID MIXTURES AS PHASE CHANGE MATERIALS

A Beginner s Guide to Differential Scanning Calorimetry (DSC)

Purity Determination and DSC Tzero Technology

Physical Aging and Fragility of Amorphous Polyethylene Terephthalate

EXPERIMENTAL APPLICATIONS OF DIFFERENTIAL SCANNING CALORIMETRY TO TEST AND CHARACTERIZE POLYMERS AT THE UNIVERSITY OF WASHINGTON BOTHELL

OPEN YOUR EYES TO A WORLD OF OPPORTUNITY IN THERMAL ANALYSIS. DSC 4000/6000/8000/8500 Comprehensive Solutions for Differential Scanning Calorimetry

Introduction to TG/DTA/DSC. Thermal Processing Technology Center Illinois Institute of Technology

Thermal Analysis. Dr. Lidia Tajber School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

Thermal Analysis Application

A Short Reviews of Thermal Techniques

Thermogravimetric Analyzer

Thermal Analysis Excellence

Impact of Tzero Technology on the Measurement of Weak Transitions

A chemical change indicates the onset of oxidation or degradation of the material. 2,3 There are

Thermal Analysis Excellence

Physical Aging and Fragility of Amorphous Sucrose by DSC

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

SOLVING ADHESION AND DIE BUILDUP PROBLEMS IN EXTRUSION COATING

Thermal Analysis. Application Handbook. Thermal Analysis of Polymers Selected Applications

DIFFERENTIAL SCANNING CALORIMETRY OF ULTRAMID PLASTIC MATERIAL

SMALL SIZE BIG POTENTIAL. STA 6000 / 8000 Simultaneous Thermal Analyzers

DSC differential scanning calorimeter (DSC)

Laser Flash Apparatus LFA 457 MicroFlash

Thermal Analysis Excellence

Thermal Analysis Premium TMA/SDTA 2+ STAR e System Innovative Technology Versatile Modularity Swiss Quality

Thermoset Curing Schedule and its Affect on the Final Properties

Development of a TG/DTA system

THE INFLUENCE OF THE HEATING AND COOLING RATES ON THE TEMPERATURE OF THE PHASE TRANSITIONS

Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1

Halogen Moisture Analyzers

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Impact of Tzero Technology on DSC Resolution

Heat Transfer in Polymers

Part 1: General principles

Thermal Analysis Methods for Composites

Pumps & Systems. Dosing Technology. Emptying Conveying Dosing

Study of glass transition of metallic glasses by temperature-modulated differential scanning calorimetry (MDSC)

ISO INTERNATIONAL STANDARD. Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature

Thermal Analysis Excellence

TA INSTRUMENTS. Thermal Analysis

Accessories for Laser Flash Analysis. Analyzing & Testing

New Castle, DE USA. Lindon, UT USA. Hüllhorst, Germany. Shanghai, China. Beijing, China. Tokyo, Japan. Seoul, South Korea.

Advanced Materials Testing

DSC - Differential Scanning Calorimetry. Investigation of the Thermal Properties of Polymers

TA INSTRUMENTS THERMOGRAVIMETRIC ANALYZERS

Thermal Value Excellence

Apollo L Thermogravimetric Analyser. Since 1987 IMP is synonymous with providing high end innovative semi and fully automated laboratory equipment

Part 1: General principles

Transcription:

Differential Scanning Calorimetry DSC 3500 Sirius Method, Technique and Applications

Differential Scanning Differential Scanning Calorimetry (DSC) is one of the most frequently employed thermal analysis methods. It can be used to analyze nearly any energetic effect occurring in a solid or liquid during thermal treatment. Easy handling and rapid analysis are among the hallmarks of this analytical technique, which has proven to be highly significant in the areas of research, development, and quality control. There are a variety of standards (ASTM, DIN, ISO, etc.) for the application, evaluation and interpretation of specific materials, products and properties. DSC Measurement Information Specific heat determination (c ) p Glass transition temperatures Melting/crystallization behavior Degree of crystallinity Cross-linking reactions Compatibility Oxidative stability Solid-solid transitions Decomposition onset Polymorphism Phase transitions Liquid crystal transitions Eutectic purity Cross-linking reactions Specific heat Purity Determination Thermokinetics 2

Calorimetry THE DSC METHOD The DSC 3500 Sirius operates according to the heat-flux principle. With this method, a sample and a reference are subjected to a controlled temperature program (heating, cooling or isothermal). The actual measured properties are the temperature of the sample and the temperature difference between sample and reference. From the raw data signals, the heat flow difference between sample and reference can be determined which represents the caloric changes of the sample. TC Voltage [μv] (~ Temperature) T M ΔT = T R - T S t 1 T R T S t 2 T M Difference ~ Mass c p Reference signal Sample signal Transition temperature Time [s] Area A ~ Transition enthalpy Difference (from 0) ~ Mass c p The sample is placed inside a crucible which is then placed inside the measurement cell (furnace) of the DSC system along with a reference pan which is normally empty. The DSC 3500 Sirius is in line with nearly every respective instrument and application standard, including: ISO 11357, ASTM E793, ASTM D3895, ASTM D3418, DIN 51004, DIN 51007, DIN 53765. furnace sample t 1 t 2 Time [s] Signal generation in a heat-flux DSC reference Q PR ΔT Schematic of a heat-flux DSC cell 3

DSC 3500 Sirius The gas-tight DSC 3500 Sirius combines the advantages of modern technology, high sensitivity and a robust, easy-tooperate workhorse. Tests can be carried out in the temperature range between -170 C and 600 C. Key components of the DSC 3500 Sirius are the DSC heat-flux sensor, the furnace and clever connection fittings which are designed for the quick and easy attachment of various cooling systems. The sensor of the DSC 3500 Sirius combines high stability and optimized resolution of thermal effects. Laserguided welding processes for the sensor disks and thermocouple wires yield true sensitivity and robustness. TRUSTWORTHY AND STURDY 4

ADVANTAGES TO YOUR BENEFIT Reliable Furnace and Sensor Optimized design of the furnace and the sensor results in a highly stable baseline and excellent signal-tonoise ratio. Variable Gases and Cooling Options Protective and purge gas inlets are, of course, standard features of the unit. For improved cooling times and subambient temperature tests, various cooling options can be connected. Of course, a versatile gas switching and flow control system are also available. Efficient Automatic Sample Changer For applications with a high sample throughput, we offer an automatic sample changer (ASC) for up to 20 samples and references which accommodates different crucible types. Flexibility and high sample throughput allow for efficient time management. All-Encompassing Smart Instrumentation Ease of handling is provided during measurement setup and evaluation by the SmartMode. This incorporates predefined measurement methods and wizards, Auto-Evaluation and Identify. 5

RELIABLE INSTRUMENTATION From Measurement Setup to Just a few clicks to start a measurement SmartMode There's no need to be an expert in thermal analysis to start a measurement! SmartMode No Need to be Well Versed The SmartMode boasts a clear structure, a consistent navigation concept and easy-to-access buttons. Using Wizards measurement templates), it is possible to start a measurement with just a few inputs. Alternatively, customized methods or predefined methods can be selected to set up an experiment. The predefined methods already contain all required parameters for those materials which are listed in the NETZSCH poster Thermal Properties of Polymers. Even customers unfamiliar with the software immediately know how to proceed. ExpertMode Not Just for Professional Users For those who wish to dive deeper into the software for enhanced option setting or for method definition, switching from SmartMode over to ExpertMode is the answer. Here, the user has access to the established Proteus software functionality, including dozens of features and all adjustment settings. AutoCalibration Allows for Full Concentration on the Measurement Tasks Calibration procedures should be simple, fast and ideally done along the way. AutoCalibration provides automatic creation routines for all relevant calibration curves, automatically loading the current calibrations while taking the selected measurement conditions into account and checking their validity periods. 6

AutoEvaluation to Identify AutoEvaluation automatically analyzes unknown curves of polymers and metal melts. AutoEvaluation* Autonomous Evaluation for Polymers Identify* A Step Ahead with the Database AutoEvaluation is a self-acting software package which evaluates glass transition temperatures, melting enthalpies or peak temperatures. For melting effects, for example, both the peak temperature and the enthalpy are determined; in the case of a glass transition, the software calculates Tg (the glass transition temperature) and the step height, expressed as Δc p. For all those who haven't seen such measurements yet, Auto-Evaluation will handle the curve independently without any effort on the operator's part. This ground-breaking technology allows, for the first time in history, test analyses which are fully user-independent and therefore completely objective. Of course, users can still run manual evaluation, if required. The Identify software searches for similar results stored in polymer libraries, providing instantaneous interpretation of the measurement at hand. With the Identify software package, it is possible to carry out one-on-one comparisons with individual curves or literature data from selected libraries, or to check whether a particular curve belongs to a certain class. These classes may contain sets of data for various types of the same polymer e.g., several types of PE but also curves, such as ones which are classified as PASS or FAIL in terms of quality control. Both the libraries and the classes are boundless and users can expand them with experiments and knowledge of their own. * Optional software extensions 7

RELIABLE RESULTS THE BASIS FOR EFFECTIVE WORK Stable Baselines & High Repeatability Smart Furnace Sensor Design The heating wires of the furnace surround the entire sensor plate. They are arranged in such a way that no temperature gradients occur in or above the sensor disk. This arrangement is the basis for a highly homogeneous heat flow to the sample and reference pans from all sides and therefore also for a very stable baseline and an optimum signal-to-noise ratio. DSC/mW 1.5 exo 1.0 Value: -100.0 C, 0.004 mw Value: -100.0 C, 0.009 mw 0.5 Value: -100.0 C, 0.010 mw 0.0-0.5-1.0 1 st heating 2 nd heating 3 rd heating Value: 300.0 C, -0.012 mw Value: 300.0 C, -0.005 mw Value: 300.0 C, 0.012 mw Furnace lid Intracooler head insert port -1.5-100 -50 0 50 100 150 200 250 300 High baseline repeatability demonstrated on three measurement curves DSC/mW 0.20 exo 0.15 Small gas-tight DSC cell 0.10 0.05 0.00 Value: 282.60 C, 0.008 mw Access window of cooling head (closed) -0.05-0.10-0.15 Value: -51.60 C, -0.008 mw LN 2 outlet LN 2 intlet -0.20-100 -50 0 50 100 150 200 250 300 Enlarged baseline between -100 C and 300 C demonstrating that the excellent baseline stability is within the ± 0.01-mW range. 8

Compact Design Fits into Any Corner of Your Lab Gas-Tight A Prerequisite for OIT Tests Economic Cooling User-Interchangeable Devices The DSC 3500 Sirius features a particularly slim design requiring only a small footprint. A clever solution for sample handling is provided by the metallic shelf on top of the DSC system. 380 mm 180 mm The gas-tight measurement cell offers defined atmospheres for optimum measurement conditions. Three magnetic valves control the gas flows and are on/off programmable. Alternatively, mass flow controllers are optionally available. These features all positively affect the process of determining the oxidativeinduction time/temperature (OIT). In addition, gas-tightness allows for the avoidance of any impact on the DSC system caused by high environmental humidity. Condensation problems in geographical areas with high humidity, for example, are greatly reduced. Protective and purge gas inlets are standard features of the unit. Of course, a versatile gas switching system and flow control system are also available. For improved cooling times and subambient temperature tests, various cooling options are available. Intracooler and liquid nitrogen (LN 2 ) systems can be interchanged with almost no effort by the user. Our optimized LN 2 cooling system features low liquid nitrogen consumption. 520 mm 320 mm Dimensions of the DSC 3500 Sirius with optional Automatic Sample Changer (ASC) Cooling Options Air compressor cooling: RT to 600 C Vortex cooling: 0 C to 600 C Intracooler IC 40: -40 C to 600 C Intracooler IC 70: -70 C to 600 C Liquid nitrogen: -170 C to 600 C Al cooling body Small but Powerful 9

Automatic Sample Changer SUPERVISION RELINQUISHED For applications with high sample throughput, an automatic sample changer (ASC) for up to 20 samples and references is available. Besides standard aluminum pans, the ASC can accommodate pressure-tight crucibles (autoclaves), ceramic and metallic sample pans. Transport safety is provided by the four arms of the gripper. This mechanism safely removes the crucible from the magazine and places it carefully without jiggling into its position on the sensor. The reference crucible can also be changed out as often as the application requires. The ASC can be easily programmed via the SmartMode of the Proteus software. A specific measurement program (method) can be assigned to each sample on the tray. This can include evaluation routines as well. In other words, the ASC not only handles the samples, but also carries out measurement and evaluation without the need for supervision. 10

Light-Curing via UV Add-On Besides thermally activated reactions, which can be studied by conventional Differential Scanning Calorimetry (DSC), many polyaddition reactions and radical polymerizations can also be started by irradiation with sufficiently high energy. For the DSC 3500 Sirius, we offer a UV add-on consisting of a UV lamp and controller, a pulse generator for shutter control, and a UV fiber lid with a lid rest for convenient handling. Advantages of Photo-DSC Tests Extending the DSC technique with light radiation capability Analyzing photo-initiated reactions in a broad variety of materials Measuring the light curing of polymer resins, paints, coatings and adhesives (degree of cross-linking) Studying the influence of UV stabilizers in pharmaceuticals, cosmetics and foods (aging effects) Selecting temperature, atmosphere, light intensity, wavelength and exposure time Determining the reactivity and curing time of dental composites Technical Specifications of the UV Add-On Temperature range -100 C to 200 C Crucibles Open aluminum Recommended Hg-lamp types DELOUX 04 Omnicure S 2000 Max. power 9.9 W/cm 2 > 10 W/cm 2 Wavelength range 315 nm to 500 nm 320 nm to 500 nm Irradiation time 0.1 s to 1000 s 0.2 s to 1000 s Existing orifice diameter 8 mm, 4 mm, 2 mm 8 mm, 4 mm, 2 mm 11

Identification The DSC 3500 Sirius is also well suited for investigations in the polymer and food industries. Packaging Films Based on PE, PP and PA The upper plot displays the 2 nd heating runs for three different packaging films A, B and C. Only for samples A and B was a later peak detected at 247 C and 253 C, respectively which is the typical melting range for different kinds of polyamides (PA). The peak at 159 C exhibited solely by film C is most probably attributable to the melting of polypropylene (PP). The two peaks additionally located at 126 C and 140 C, as well as those detected in the same temperature range in the DSC curves of films A and B, are due to the different polyethylene (PE) types. In the figure below, the advanced Peak Separation software was used to separate the three peaks detected in sample B between 100 C and 125 C. The graph shows the almost perfect correlation between the measured curve (dotted) and the sum of three calculated curves (red). DSC/( mw/mg) 3.0 2.5 2.0 1.5 1.0 exo DSC/( mw/mg) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0-0.1 117.2 C 107.3 C 127.0 C 126.4 C 121.0 C 136.9 C 139.5 C 159.1 C Film A Film B Film C 100 150 200 250 Temperature/ C Measured Sum of calculated curves Curve 1 Curve 2 Curve 3 Temperature/ C 246.5 C 252.6 C 2 nd heating runs on three materials between 30 C and 300 C; heating rate of 10 K/min. The 1 st heating yields information on the thermal history of a polymer; the 2 nd heating reflects its material properties. 70 80 90 100 110 120 130 Separation of the triple peak of sample B by means of the optional software package Peak Separation 12

-0.1 70 Composition and Oxidative Stability DSC/( mw/mg) exo 5 4 Solid Line: 1 st hea 3 2 DSC/(mW/mg) 1.5 1.0 0.5 0.0-0.5-1.0 exo heating cooling DSC/mW/mg exo -0,25-0,30-0,35-0,40 Area: -41.7 J/g -69.4 C Area: -0,2 J/g Peak*: -3,5 C -10-8 -6-4 -2 0 2 4 6 Temperature / C -64.3 C Area: -3.7 J/g Peak: 52.8 C -44.8 C -27.1 C -18.1 C Area: 46.9 J/g -18.3 C -11.7 C Area: -0.2 J/g Peak -3.5 C*: -80-60 -40-20 0 Rapeseed oil, sample mass: 1.19 mg, aluminum crucible with pierced lid; cooling to -150 C, heating to 40 C, heating/cooling rate 10 K/min Melting and Crystallization Behavior of Edible Oil 190 2 This rapeseed oil sample was first cooled to -150 C and then heated to 40 C. The exothermic peak beginning DSC/(mW/mg) at -18 C (during controlled cooling, 0 blue curve) is due to the crystallization of the oil. The minima at -45 C, -1 exo -64 C and -69 C reflect the composition of the oil consisting mainly of Area: -55.34 J -2 Peak: 186.8 C End: 187.1 C oleic acid, linoleic acid and linolenic -3 acid as well as of various saturated -4 and unsaturated fatty acids. The peak -5 detected at -4 C is probably caused by the crystallization of an additive. -6 In the subsequent heating, post-crystallization occurs at -53 C, followed by -7 the melting of the oil components 170 (peaks at-27 C, -18 C and -12 C). 1 0 Dashed: 2 nd heati DSC(mW/mg) exo 0.8 0.6 0.4 0.2 0.0-0.2-0.4-0.6 OIT: 4.2 min OIT: 13.1 min Dashed: DSC signal under nitrogen Continuous: DSC signal under air Dotted: Temperature signal OIT: 63.3 min 20 40 60 80 100 Time/min Rapeseed oil, sample mass 1.19 mg, aluminum crucible with pierced lid; cooling to -150 C, heating to 40 C, heating/cooling rate 10 K/min, isothermal temperatures 140 C (green), 160 C (blue) and 180 C (red). Temp./ C 180 160 140 120 100 80 60 40 20 Oxidative-Induction Time (OIT) The Relative Stability of Hydrocarbons to Oxidation This plot shows OIT measurements on rapeseed oil heated to three different temperatures under inert conditions. After a five-minute equilibration time, the atmosphere was switched to air. The DSC curves show the influence of the test temperature on the degradation of the samples. Degradation began earlier at higher temperatures: It took 63 min under oxidizing conditions at 140 C, but only 4 min for the test carried out at 180 C. 13

400 450 500 mplex Peak: rea:-1.219 J/g ak*:73.8 C ion: 21 J/(g*K) *K): for the two samples. Both 70 80 90-18.1 C a: 46.9 J/g -11.7 C Area: -0.2 J/g Peak -3.5 C*: Quality Control on Two Solders Two solders made of the same material but taken from different lots were each heated two times. The upper plot compares the 1 st and 2 nd heating segments segments exhibit an endothermic peak (onset temperature at 217 C) which is due to the melting of the metal alloys. The two alloys exhibit similar melting behavior. This is expressed not only in the shape of the curves but also in the peak temperatures and areas. The Importance of Cooling Runs In contrast, the cooling behavior -18.3 C of the two samples differs after the 1 st heating (lower plot). Lot -20 01 (blue curve) already crystallizes at 189 C, whereas lot 2 exhibits an even stronger undercooling effect; the start of crystallization is shifted to a lower temperature (endset 187 C). This effect can be explained by differing impurity content between the two products. Quality DSC/( mw/mg) Control & 0.9 0.8 0.7 Measured Sum of calculated curves Failure 0.6 Analysis Curve 1 0.5 Curve 2 Curve 3 0.4 0.3 0.2 0.1 0-0.1 DSC/( mw/mg) 70 80 90 100 110 120 130 5 Area: 55.23 Temperature/ J/g C exo Area: 55.36 J/g Peak: 221.5 C Peak: 222.1 C Onset*: 216.8 C Onset*: 216.8 C 4 DSC/( 3 mw/mg) 52 41 30 2 1 0 Solid Line: 1 st heating exo Dashed: 2 nd heating Solid Line: 1 st heating Area: 55.23 J/g Peak: 221.5 C Area:55.96 J/g Onset*: 216.8 C Peak: 219.9 C Onset: 216.7 C Area: 55.36 J/g Peak: Area: 222.1 55.98 C J/g Onset*: Peak: 220.0 216.8 C C Onset: 216.7 C Lot 1 Lot 2 Lot 1 190 200 210 220 230 240 Lot 2 Area:55.96 J/g Area: 55.98 J/g 1 st and 2 nd heating runs on two Peak: solder 219.9 materials. C Sample mass Peak: 6.47 220.0 mg C (lot 1)/ 7.05 Dashed: mg (lot 2 nd 2), heating Al crucible with Onset: pierced 216.7 lid, Cheating rate 10 Onset: K/min. 216.7 C 0 190 200 210 220 230 240 exo -1 Area: -55.34 J/g Area: -55.16 J/g -2 Peak: 186.8 C Peak: 188.7 C End: 187.1 C End: 189.0 C -3 DSC/(mW/mg) Lot 1-4 0 exo Lot 2-5 -1-6 Area: -55.34 J/g Area: -55.16 J/g -2 Peak: 186.8 C Peak: 188.7 C -7 End: 187.1 C End: 189.0 C -3 Lot 1-4 170 180 190 200 210 220 Lot 2-5 -6-7 170 180 190 200 210 220 Cooling segment on the two solder materials after first heating; cooling rates of 10 K/min. 14

A smart metal needs a smart instrument High performance for fast quality control not only on polymers but also metals. DSC/(μV/mg) 0.4 exo Shape-Memory Alloy 0.2-0.0-0.2-0.4-0.6-0.8 44.14 C 43.01 C 0 50 100 150 200 Heating (red curve) and cooling (blue curve) of a shape-memory alloy; sample mass of 13.82 mg, heating rate of 5 K/min, nitrogen atmosphere, aluminum crucible with pierced lid. Shape-memory alloys remember their original shape and, following deformation, return to their prior shape upon heating. Their most commonly encountered phase change is the martensitic transformation, which is a nondiffusional transformation. This effect can be studied by DSC. The measurement shown here on a TiNi alloy depicts the martensitic transformation of austenite at 44 C (peak temperature) during heating. During cooling, the low-temperature martensite is formed at 43 C. 15

Temperature-Modulated DSC Separation of Overlapping Effects For temperature-modulated DSC (TM DSC), the heating rate is varied by overlapping the underlying linear heating rate with a sinusoidal temperature modulation. At the same time, the sample is subjected to a non linear temperature (see upper plot inset). This allows for good separation of glass transitions from effects such as relaxation, curing, etc. PVB Determination of the Glass Transition Temperature This TM-DSC measurement on PVB allows for the separation of the modulated signal (upper plot) into a reversing (lower plot, red curve) and non reversing (lower plot, blue curve) signal. The glass transition is a reversible energetic effect and can be clearly seen from the reversing curve (red) at 73.5 C. The relaxation peak (at 73.8 C in the total signal, black curve) can be clearly detected in the non-reversing curve (blue, lower plot). The endothermal effect between 20 C and 60 C is due to the evaporation of humidity. DSC/(mW/mg) 0.1 0.0-0.1-0.2-0.3-0.4-0.5 exo Temp./ C 89 88 87 86 85 84 83 82 81 DSC/(mW/mg) exo 0.10 123.5 124.0 124.5 125.0 126.0 125.5 126.5 Time/min 70 80 90 100 110 120 130 Time/min Complex Peak: Area:-1.219 J/g Peak*:73.8 C 120 100 80 60 40 20 0-20 0.05 Area: -11.4 J/g 0.00-0.05 Area: -10.16 J/g Glass Transition: Mid:73.5 C Delta C p *:0.321 J/(g*K) -0.10-0.15 Glass Transition*: Mid: 72.6 C Delta C p *: 0.333 J/(g*K): 0 10 20 30 40 50 60 70 80 90 TM-DSC measurement on polyvinyl butyral film (PVB); sample mass of 6.034 mg, Al crucible with pierced lid, heating rate of 2 K/min, amplitude of 0.5, period of 80 s, N 2 atmosphere. The sample was held under humidity for 4 h prior to the measurement. 16 DSC/(mW/mg)

Thermophysical Properties (TPP) Specific Heat Capacity Molybdenum SRM 781 The NBS standard material reference material no. 781 (99.95 mass% polycrystalline molybdenum) is a common reference material for specific heat capacity (c p ) measurements with wellproven c p data. C p /(J/(g K)) 0.5 0.4 0.3 0.2 N=1 N=2 Table Value For the upper plot, the DSC 3500 Sirius was used to determine the c p of SRM 781 between room temperature and 500 C. Afterward, the heat capacity values obtained were compared with those provided by NIST (National Institute of Standards and Technology; see table below). 0.1 0.0 50 100 150 200 250 300 350 400 450 500 Determination of the specific heat capacity of molybdenum; sample mass 284.67mg; heating rate 10 K/min, 20 ml/min N 2 atmosphere These measurements were performed in Pt crucibles with an alumina inlet and pierced lid (see photo). Experimental data in comparison with literature data (NIST) on sapphire Temperature [ C] Experimental [J/(g K)] C p according to NIST [J/(g K)] 25 0.245 0.248 100 0.263 0.259 200 0.271 0.268 300 0.278 0.274 400 0.284 0.280 500 0.291 0.285 17

exo Curing Behavior Temp./ C 89 88 87 86 85 84 83 82 81 UV Influence 123.5 124.0 124.5 125.0 126.0 125.5 126.5 Time/min Influence of Irradiation Time on a UV-Curing System DPHA polymerizes when exposed to sources of free radicals. It is particularly useful in coatings and inks. Here, the influence of the irradiation time (1s, 10s, 30s and 60s) is demonstrated at a sample temperature of 27 C. With increasing irradiation time, the curing increased, which can be seen in the total enthalpy. The corresponding integral curves reflect the conversion due to UV curing. DSC/(mW/mg) 20 15 10 5 0 exo 1 s 10 s integral curves 30 s 60 s 60 s 30 s 10 s Integral /(J/g) 0.0 0.5 1.0 1.5 2.0 Time/min 1 s 250 200 150 100 50 0 Temp. / C 40 35 30 25 Irradiation time dependence of DPHA (dipentaerythritol penta/hexa acrylate) + irg 184 (initiator 0.05%). The advantage of UV-curing systems is their fast reaction within a few seconds at low isothermal temperature in the absence of solvents. 18

Key Technical Data DSC type DSC 3500 Sirius Gas-tight heat flux system Temperature range -170 C to 600 C Heating/cooling rates Measurement range Accuracy Cooling devices (options) Atmospheres Gas control Oxidative-Induction Time Automatic sample changer (ASC) Software add-ons (optional) Accessories Dimensions of instrument 0.001 K/min to 100 K/min (cooling rate depends on temperature) ± 600 mw Temperature: 0.1 K Enthalpy: < 1% for metals; < 2% for most materials Air compressor cooling: RT to 600 C Vortex cooling: 0 C to 600 C Intracooler IC 40: -40 C to 600 C; Intracooler IC 70: -70 C to 600 C Liquid nitrogen cooling: -170 C to 600 C Al cooling body Oxidizing, inert (static, dynamic) 3 integrated frits; 3 magnetic valves (on/off programmable) Optional 3 mass flow controllers or gas flow control device Integrated in the software For up to 20 samples and references (optional) Removable magazine Temperature-modulated DSC Specific heat capacity (c ) determination Peak Separation p Thermokinetics AutoEvaluation Identify Variety of crucibles (Al, Pt, Al O, Au, Ag, Cu, autoclaves, etc.) For easy sample preparation, 2 SampleCutter 3 and sample preparation kit Height 380 mm (560 mm with ASC) x width 320 mm x depth 520 mm Mass: 28 kg Medium-pressure crucibles (left) and high-pressure crucibles (right) Sealing press for different aluminum crucible types Al crucibles with lids 19

The NETZSCH Group is a mid-sized, family-owned German company engaging in the manufacture of machinery and instrumentation with worldwide production, sales, and service branches. The three Business Units Analyzing & Testing, Grinding & Dispersing and Pumps & Systems provide tailored solutions for highest-level needs. Over 3,300 employees at 210 sales and production centers in 35 countries across the globe guarantee that expert service is never far from our customers. When it comes to Thermal Analysis, Calorimetry (adiabatic & reaction) and the determination of Thermophysical Properties, NETZSCH has it covered. Our 50 years of applications experience, broad state-of-the-art product line and comprehensive service offerings ensure that our solutions will not only meet your every requirement but also exceed your every expectation. NETZSCH-Gerätebau GmbH Wittelsbacherstraße 42 95100 Selb Germany Tel.: +49 9287 881-0 Fax: +49 9287 881 505 at@netzsch.com NGB DSC 3500 Sirius EN 0616 NWS Technical specifications are subject to change.