um"ts: m1 1grams per rt1er (mg./l)

Similar documents
French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/

Appendix U. Mapping of Water Quality Concentration Contours across the Province

ICP/ICP-MS Standards. High Purity Standards for ICP/ICP-MS

CERTIFICATE OF ANALYSIS

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

RITES Lab, Western Region, 210, Amit Industrial Estate, 61, Dr. S.S. Rao Road, Parel, Mumbai, Maharashtra

State of Utah. Department of Health Environmental Laboratory Certification Program. Certification is hereby granted to

ANALYTES available for testing

Water Monitoring - Teralba Quarry EPA Point No.4 - Adit Overflow

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016

NEILSON RESEARCH CORPORATION

2019 Microbac Laboratories Inc. Ohio Valley Division

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

Microbac Laboratories, Inc. AZ0723

Appendix C: Water Quality Data

CERTIFICATE OF ANALYSIS REVISED REPORT

CALA Directory of Laboratories

ENVIRONMENTAL LABORATORY LICENSE AZ0723

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

Participate in proficiency testing studies semi-annually, with the following exception

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

Appendix C1: Batch Kinetics Tests

(Calibration) (Reference Material Production) ISO/IEC 17025:2005 (Calibration)

SUB-Programs - Calibration range Fe Base for "FOUNDRY-MASTER UV"

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

DRINKING WATER ANALYSIS SUMMARY

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS REVISED REPORT

In the fall of 2008, Barr and PolyMet identified four sources of historical Colby Lake water quality data. Those sources are listed below:

ENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102

December 6, 2018 FID:

Appendix C Aquatic Environment - Photographs and Tables

UltraPur TMP. Trimethylphosphite FEATURES & BENEFITS. Canisters and delivery systems APPLICATIONS

Bottom Ash Data Week 52

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS

CALA Directory of Laboratories

Certificate of Analysis

Bottom Ash Data Week 45

Abu Dhabi Trade Effluent Standards & Regulations Summary

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

Bottom Ash Data Week 47

West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division

Drinking Water Analyses

SPECIFIC HEAT OF A METAL0103CP1

Water Quality Protection Issues for New Water Supply Wells

Jacqueline Ho, Mackenzie Valley Land and Water Board

CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

CERTIFICATE OF ANALYSIS

CALA Directory of Laboratories

HAIR ELEMENTS. PATIENT: Number 496 SEX: Female AGE: 70. POTENTIALLY TOXIC ELEMENTS TOXIC RESULT REFERENCE PERCENTILE ELEMENTS µg/g RANGE 68 th 95 th

Statewide Characterization of Oklahoma s Major Aquifers

Influent preheating (note that the heat will be recovered before discharge);

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

DISTRICT OF LILLOOET Box 610 Lillooet BC V0K 1V0

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Safety Data Sheets (SDSs) Soon To be Avalable for Purchase from AFS

Contents. Introduction Technical Services Customised Quote Request Form Quality at Reagecon...

Appendix V6-2A Analytical Results of the Umwelt Westbay Groundwater Sampling Program

Nomenclature Unit I Elements You Should Know

SAMPLE COLLECTION DATE March 25, st Quarter SOUTH WATER PURIFICATION PLANT

Laboratory Turnaround Times and Prices

Practice General Chemistry Speaking Test (I. Gould) (Questions from Chapter 1 of the textbook) hydrogen 1 H

Atomic Masses (amu) IA IIA IIIB IVB VB VIB VIIB VIIIB VIIIB VIIIB IB IIB IIIA IVA VA VIA VIIA VIIIA

STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION

CERTIFICATE OF ANALYSIS

Nomenclature Unit I Elements You Should Know

Please find information regarding the Leachate reporting requirements for the July 15, 2018

TITLE: SABS PROFICIENCY TESTING SCHEME, RSA

CERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION

Date Issued: July 01, 2018 Expiration Date: June 30, 2019

CALA Directory of Laboratories

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

ADDITIONAL SCIENCE/CHEMISTRY. A.M. TUESDAY, 14 January hour

LABORATORY TURNAROUND TIMES AND CHARGES

Corrosion Studies on GeoBrom HG520

Drinking Water Quality Monitoring Report Vancouver Police Department Vancouver, British Columbia

CERTIFICATE OF ANALYSIS

Final Report WP-225. WatR Pollution Study. Open Date: 10/18/13. Close Date: 12/02/13. Report Issued Date: 12/04/13

Colorado Water Energy Research Center. Total number of pages in report:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Texas Commission on Environmental Quality

Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014

BLACK STURGEON LAKES WATER QUALITY MONITORING

Aluminum 18 i. 0 Antimony

Total Leachate Collected= 9.45 m^3 Total Leachate Stored= m^3 Total Leachate Transported= 0 m^3

ADDITIONAL SCIENCE/CHEMISTRY

ADDITIONAL SCIENCE/CHEMISTRY

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE

BLACK STURGEON LAKES WATER QUALITY MONITORING

General Certificate of Secondary Education ADDITIONAL SCIENCE. FOUNDATION TIER (Grades G-C) P.M. FRIDAY, 18 January 2008 (45 minutes)

Table B1: Analytical Results for Nutrients in Surface Water

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

Ground Water Quality Report. Inorganic Ground Water Quality Time Series

New GCSE 4472/02 ADDITIONAL SCIENCE

Statistics valid as of January 2004.

Transcription:

28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (31 4) 531-8085 P.O. Box 897 Page 1of8 REPORT OF ALYSIS ID: WATER NO. 1-1 5 T FLOOR BREAKROOM, 05/09/16 um"ts: m1 1grams per rt1er (mg./l) ANION SCAN ALYTE N0.1 DATE OF ALYSIS ALYST Fluoride < 1.0 4.0 2.0* Chloride 22.0 Nitrite-N < 0.5 1.0 Nitrate-N 2.5 Total Nitrate/Nitrite -N 2.5 Sulfate (S04) 7 Orthophosphate (P04) < 5.0 N/A Test Method: 300.0 (IC) - Not Applicable * Secondary Contaminant- Unenforceable Federal Recommended Guideline

28 Clark Avenue St. Louis, MO 633-2574 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 2 of 8 REPORT OF ALYSIS ID: WATER NO. 2-2No FLOOR BREAKROOM, 05/09/16 um"ts: m1 1grams per rt1 er (mg/l) ANION SCAN ALYTE N0.2 DATE OF ALYSIS ALYST Fluoride < 1.0 4.0 2.0* Chloride 18.7 Nitrite-N < 0.5 1.0 Nitrate-N 3.0 Total Nitrate/Nitrite -N 3.0 Sulfate (S04) 94.1 Orthophosphate (P04) < 5.0 N/A Test Method: 300.0 (IC) - Not Applicable *Secondary Contaminant - Unenforceable Federal Recommended Guideline

28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 3 of 8 REPORT OF ALYSIS ID: WATER NO 3-1 5 T FLOOR DRINKING FOUNTAIN, 05/09/16 m : mr rgrams per 1er mg/l) ANION SCAN ALYTE N0.3 DATE OF ALYSIS ALYST Fluoride < 1.0 4.0 2.0* Chloride 20.1 Nitrite-N < 0.5 1.0 Nitrate-N 3.2 Total Nitrate/Nitrite -N 3.2 Sulfate (S04) 96.1 Orthophosphate (P04) < 5.0 N/A Test Method: 300.0 (IC) - Not Applicable * Secondary Contaminant - Unenforceable Federal Recommended Guideline

28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 4 of 8 REPORT OF ALYSIS ID: WATER N0.4-2ND FLOOR DRINKING FOUNTAIN, 05/09/16 um"ts: m1 1Qrams per rter 1 (mg/l) ALYTE N0.4 Fluoride < 1.0 ANION SCAN 4.0 2.0* DATE OF ALYSIS ALYST Chloride 24.8 Nitrite-N < 0.5 1.0 Nitrate-N 3.2 Total Nitrate/Nitrite -N 3.2 Sulfate (S04) 1 Orthophosphate (P04) < 5.0 N/A Test Method: 300.0 (IC) - Not Applicable * Secondary Contaminant - Unenforceable Federal Recommended Guideline

28 Clark Avenue St. Louis, MO 633-2574 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 5 of 8 REPORT OF ALYSIS ID: WATER NO. 1-1 5 T FLOOR BREAKROOM, 05/09/16 Units: milligrams per liter (mg/l) ICP SCAN ALYTE N0.1 ALYTE N0.1 Silver 0.* Sodium 37.0 Aluminum < 0.05 0.20* Niobium Arsenic 0.01 Nickel 0.005 0. Boron 0.056 Lead 0.015** Barium 0.022 2 Antimony 0.006 Beryllium < 0.004 0.004 Selenium 0.05 Calcium 24.6 Silicon 3.44 Cadmium 0.005 Tin Cobalt Strontium 0.19 Chromium 0.005 0. Tantalum Copper 0.06 1.3** Titanium Iron 0.08 0.3* Vanadium Potassium 5.78 Zinc 0.07 5.0* Magnesium.9 Zirconium Manganese 0.05* Lithium 0.019 Molybdenum Phosphorus 0.19 Mercury < 0.001 0.002 Test Method: 200.7 Test Method: 200.8 Date of Analysis: Date of Analysis: Analyst: H. Blake Analyst: G. Fogelman - Not Applicable *Secondary Contaminant-Unenforceable Federal Guideline Action Level

28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 6 of 8 REPORT OF ALYSIS ID: WATER NO. 2-2No FLOOR BREAKROOM, 05/09/16 Units: milligrams per liter (mg/l) ALYTE N0.2 Silver Aluminum < 0.05 Arsenic Boron 0.047 Barium 0.023 Beryllium < 0.004 Calcium 24.6 Cadmium Cobalt Chromium 0.005 Copper 0.08 Iron 0.08 Potassium 5.38 Magnesium 9.31 Manganese Molybdenum Mercury < 0.001 ICPSCAN ALYTE 0.* Sodium 0.20* Niobium 0.01 Nickel Lead 2 Antimony 0.004 Selenium Silicon 0.005 Tin Strontium 0. Tantalum 1.3** Titanium 0.3* Vanadium Zinc Zirconium 0.05* Lithium Phosphorus 0.002 N0.2 27.2 0. 0.015** 0.006 0.05 3.21 0.18 < 0.05 5.0* 0.015 0.24 Test Method: 200.7 Test Method: 200.8 Date of Analysis: Date of Analysis: Analyst: H. Blake Analyst: G. Fogelman - Not Applicable * Secondary Contaminant-Unenforceable Federal Guideline Action Level l'jiember

281 O Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 7 of 8 REPORT OF ALYSIS ID: WATER NO. 3-1 8 T FLOOR DRINKING FOUNTAIN, 05/09/16 um"ts: m1 1grams per rt1er (mg/l) ICP SCAN ALYTE N0.3 ALYTE N0.3 Silver 0.* Sodium 37.3 Aluminum < 0.05 0.20* Niobium Arsenic 0.01 Nickel 0. Boron 0.075 Lead 0.015** Barium 0.019 2 Antimony 0.006 Beryllium < 0.004 0.004 Selenium 0.05 Calcium 25.3 Silicon 3.63 Cadmium 0.005 Tin Cobalt Strontium 0.20 Chromium 0.006 0. Tantalum Copper 0.06 1.3** Titanium Iron 0.1 0 0.3* Vanadium Potassium 6.04 Zinc 0.08 5.0* Magnesium 11.0 Zirconium Manganese 0.05* Lithium 0.018 Molybdenum Phosphorus 0.17 Mercury < 0.001 0.002 Test Method: 200.7 Test Method: 200.8 Date of Analysis: Date of Analysis: 05/116 Analyst: H. Blake Analyst: G. Fogelman - Not Applicable * Secondary Contaminant-Unenforceable Federal Guideline.,. Action Level

28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (314) 531-8085 P.O. Box 897 Page 8 of 8 REPORT OF ALYSIS ID: WATER NO. 4-2No FLOOR DRINKING FOUNTAIN, 05/09/16 Units: milligrams per liter (mg/l) ICPSCAN ALYTE N0.4 ALYTE N0.4 Silver 0.* Sodium 31.6 Aluminum < 0.05 0.20* Niobium Arsenic 0.01 Nickel 0. Boron 0.073 Lead 0.015** Barium 0.019 2 Antimony 0.006 Beryllium < 0.004 0.004 Selenium 0.05 Calcium 26.3 Silicon 3.67 Cadmium 0.005 Tin Cobalt Strontium 0.20 Chromium 0.005 0. Tantalum Copper 0.05 1.3** Titanium Iron 0.08 0.3* Vanadium Potassium 5.65 Zinc 0.06 5.0* Magnesium.1 Zirconium Manganese 0.05* Lithium 0.015 Molybdenum Phosphorus 0.20 Mercury < 0.001 0.002 Test Method: 200.7 Date of Analysis: Analyst: H. Blake Test Method: 200.8 Date of Analysis: Analyst: G. Fogelman - Not Applicable * Secondary Contaminant-Unenforceable Federal Guideline Jb ;?.;-..Action Level SR/ss Steve Root, Manager Environmental Testing NOT OFFICIAL WITHOUT THE RAISED SEAL OF ST. LOUIS TESTING LABORATORIES. INC.