Earthquake-resistant fibre-reinforced concrete coupling beams without diagonal bars

Similar documents
10NCEE REINFO FROM ABSTRACT. detailing without. end. For. 5 Lecturer, Ferzli, J. High-

Earthquake-Resistant Coupling Beams without Diagonal Reinforcement

Implementation of High-Performance Fiber Reinforced Concrete Coupling Beams in High-Rise Core-Wall Structures

Seismic Behavior and Detailing of High-Performance Fiber- Reinforced Concrete Coupling Beams and Coupled Wall Systems

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

In-plane testing of precast concrete wall panels with grouted sleeve

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

BEHAVIOR OF PRECAST HIGH-PERFORMANCE FIBER REINFORCED CEMENT COMPOSITE COUPLING BEAMS UNDER LARGE DISPLACEMENT REVERSALS

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Shear Behavior of Steel Fiber-Reinforced Concrete Beams without Stirrup Reinforcement

Interaction between ductile RC perimeter frames and floor slabs containing precast units

Numerical study of shear wall behavior coupled with HPFRCC beam and diagonal reinforcements

Seismic Analysis of Monolithic Coupling Beams of Symmetrical Coupled Shear Wall System

SEISMIC BEHAVIOR OF RCS BEAM-COLUMN-SLAB SUBASSEMBLIES DESIGNED FOLLOWING A CONNECTION DEFORMATION-BASED CAPACITY DESIGN APPROACH

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

AXIAL LOAD FAILURE OF SHEAR CRITICAL COLUMNS SUBJECTED TO HIGH LEVELS OF AXIAL LOAD

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

STRENGTH AND DUCTILITY OF RETROFITTED R/C BUILDING BY MULTI-STORY STEEL-BRACED FRAME SUBJECTED TO TRI-LATERAL EARTHQUAKE LOADING

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

MODELLING OF SHEAR WALLS FOR NON-LINEAR AND PUSH OVER ANALYSIS OF TALL BUILDINGS

UHPC Connection of Precast Bridge Deck

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

EXPERIMENTAL RESULTS

Masonry infills with window openings and influence on reinforced concrete frame constructions

Australian Journal of Basic and Applied Sciences

Seismic response of a cast-in-place steel fibre concrete joint connecting precast beams and columns

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

Reinforced Concrete Coupling Beams Part I: Testing

Bond Behavior of Reinforcing Steel in High Performance Fiber Reinforced Cement Composites under Monotonic and Cyclic Loading

Seismic Behavior of Ultra-High-Performance Fiber- Reinforced Concrete Moment Frame Members

Behavior of Reinforced Concrete Walls with Mesh Reinforcement Subjected to Cyclic Loading

Improvement of Mechanical Performance in Different Concrete Applications through Use of Steel Fibers

BS EN :2004 EN :2004 (E)

Effect of reinforcing steel bond on the seismic performance of lightly reinforced concrete walls

Hybrid-steel concrete connections under reversed cyclic loadings

CAUSES OF ELONGATION IN REINFORCED CONCRETE BEAMS SUBJECTED TO CYCLIC LOADING

Seismic Detailing of RC Structures (IS: )

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Modelling of RC moment resisting frames with precast-prestressed flooring system

Application of Buckling Restrained Braces in a 50-Storey Building

Chapter 2 Notation and Terminology

Damage Mitigation in Reinforced Concrete Shear Walls Detailed with SMA and SFRC

High-Rises, High Seismicity: New Materials and Design Approaches

IDEA OF HYBRID COLUMN WITH ENERGY ABSORPTION ELEMENT

Seismic performance of New Steel Concrete Composite Beam-Columns

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

SEISMIC RESPONSE OF END-CONFINED REINFORCED CONCRETE BLOCK SHEAR WALLS

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

Shear Strength Behaviour of Steel Truss Embedded in Flexural Plastic Hinge Zone of Reinforced Concrete Beam Subjected to Reversed Cyclic Loading

Experimental Evaluation of a Multi-Story Post-Tensioned Coupled Shear Wall Structure

Lateral Force Resisting Mechanism of a Multi-story Shear Wall and Peripheral Members

SHAKE-TABLE TESTING OF A 3-STORY, FULL-SCALE, REINFORCED MASONRY WALL SYSTEM

Seismic Behaviour of RC Shear Walls

APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

SEISMIC BEHAVIOR OF FOUR-CIDH PILE SUPPORTED FOUNDATIONS

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

Earthquake-Resistant Squat Walls Reinforced with High- Strength Steel

ANNEX 10. Special requirements recommended for structures subject to seismic actions. 1 Scope. 2 Basis of design. 2.1 Fundamental requirements

Cyclic Behavior of HPFRCC Coupling Beams with Bundled Diagonal Bars

SEISMIC FORCE RESISTING MECHANISM OF THE MULTI-STORY PRECAST CONCRETE SHEAR WALL SUPPORTED ON PILES

SEISMIC PERFORMANCE OF BRIDGE SLAB-COLUMN JOINTS WITH HEADED REINFORCEMENT

EFFECTS OF END REGION CONFINEMENT ON SEISMIC PERFORMANCE OF RC CANTILEVER WALLS

DUCTILITY REQUIREMENTS FOR BUILDINGS

Pile to Slab Bridge Connections

Influence of Longitudinal FRP Straps on the Behaviour of Circularised and FRP Wrapped Square Hollow RC Concrete Specimens

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

Beam-column joint tests with grade 500E reinforcing

Seismic Performance of Residential Buildings with Staggered Walls

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

EXPERIMENTAL RESPONSE OF BOUNDARY ELEMENTS OF CODE- COMPLIANT REINFORCED CONCRETE SHEAR WALLS

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

7. SPECIFIC RULES FOR STEEL CONCRETE COMPOSITE BUILDINGS

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Deformation Capacity and Shear Strength of Fiber-Reinforced Cement Composite Flexural Members Subjected to Displacement Reversals

Level 6 Graduate Diploma in Engineering Structural analysis

Seismic Design Principles for RC Structures

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Blast Load Performance of Reinforced Concrete Beams and Columns Constructed with SCC and Fibers

RESILIENT INFRASTRUCTURE June 1 4, 2016

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

An Overview of Research at HKU on HSRC Columns and Beam- Column Joints for Low-Medium Seismic-Risked Regions

Transcription:

Earthquake-resistant fibre-reinforced concrete coupling beams without diagonal bars G.J. Parra-Montesinos 1, J. K. Wight 2, C. Kopczynski 3, R.D. Lequesne 4, M. Setkit 5,. Conforti 6, J. Ferzli 3 1 : University of Wisconsin, Madison, WI, US 2 : University of Michigan, nn rbor, MI, US 3 : Cary Kopczynski & Co., ellevue, W, US 4 : University of Kansas, Lawrence, KS, US 5 : Walailak University, Thailand 6 : University of rescia, Italy bstract Results from large-scale tests on fibre-reinforced concrete coupling beams subjected to large displacement reversals are reported. The main goal of using fibre reinforcement was to eliminate the need for diagonal bars and reduce the amount of confinement reinforcement required for adequate seismic performance. Experimental results indicate that the use of 30 mm long, 0.38 mm diameter hooked steel fibres with a 2300 MPa minimum tensile strength and in a volume fraction of 1.5% allows elimination of diagonal bars in coupling beams with span-todepth ratios greater than or equal to 2.2. Further, no special confinement reinforcement is required except at the ends of the coupling beams. The fibre-reinforced concrete coupling beam design was implemented in a high-rise building in the city of Seattle, W, US. brief description of the coupling beam design used for this building, and construction process followed in the field, is provided. Keywords Link beams, steel fibres, shear, coupled walls, displacement reversals. 1 Introduction Coupled walls consisting of structural walls connected by link or coupling beams are a common structural system used in medium- and high-rise structures for earthquake resistance. Typical span-to-depth ratios for coupling beams range between 1.5 and 3.5. Given their low aspect ratio and the large rotation demands these beams can be subjected to during a major earthquake, the design of coupling beams has long represented a challenge for engineers. Current design practice for coupling beams is primarily based on research conducted in the 1970s (see Paulay and inney, 1974). Diagonal bars are provided such that they are capable of resisting the entire shear demand. Closely spaced transverse reinforcement is also required to 461

provide confinement to the concrete and lateral bar support (Figure 1), either along the diagonal reinforcement cages, or to the entire member core. lthough this design has been shown to perform well under large displacement reversals (Paulay and inney, 1974; Naish et al., 2009), the construction of diagonally reinforced coupling beams is difficult and time consuming and may control the construction schedule in some cases. The difficulties mentioned above make it clear that there is need for a simpler coupling beam design that can be implemented economically in the field. Given the tensile and compression ductility of tensile strain-hardening fibre-reinforced concrete, typically referred to as highperformance fibre-reinforced concrete (HPFRC), the use of such a material was thought to show promise as a means to provide shear resistance and confinement, allowing reduced reliance on bar-type reinforcement to ensure adequate seismic behaviour. Figure 1: Typical design of earthquake-resistant coupling beams. 2 Research program 2.1 Tests of HPFRC coupling beams The research on the use of HPFRC as a means to simplify reinforcement detailing in earthquake-resistant coupling beams spanned several investigations conducted for over a decade (Canbolat et al., 2004; Parra-Montesinos et al., 2010; Lequesne, 2011; Setkit, 2012; Lequesne et al., 2013). Thus, only tests and results most related to the coupling beam design ultimately adopted in a high-rise structure recently completed in the city of Seattle, W, US, will be presented. Tests were conducted on isolated coupling beams, as shown in Figure 2. Each test specimen consisted of a coupling beam connected to two large reinforced concrete (RC) blocks simulating the edges of two structural walls. For testing convenience, each coupling beam subassembly was rotated 90 degrees. The tests were conducted at the University of Michigan Structural Engineering Laboratory. The bottom block in Figure 2 was anchored to a strong floor. The top block was connected to a hydraulic actuator, which was connected at the other end to a reaction wall. Lateral displacements were applied to the top block. The vertical steel links shown in Figure 2 restrained rotation of the top block, ensuring double curvature bending of the coupling 462

beam. lso, these links provide some level of axial restraint, which in a real structure is provided by the structural walls and slab. Lateral displacement cycles of increasing drift magnitude were applied to the coupling beams up to failure. Drift, as reported herein, corresponds to the chord rotation of the coupling beam. Figure 2: Coupling beam test setup. Reinforcement details for the three coupling beam tests discussed herein are provided in Figure 3. Coupling beam span-to-overall depth ratio was either 2.2, 2.75, or 3.3. No diagonal reinforcement was used in any of the three coupling beams. s shown in Figure 3, closely spaced transverse reinforcement was provided at the ends of the coupling beams, over a distance half the beam depth from each end. This reinforcement complied with transverse reinforcement required for confinement at the ends of columns in special moment resisting frames, according to Chapter 21 of the 2011 CI uilding Code (CI Committee 318, 2011). In the remaining span of the coupling beam, single closed hoops were provided. ssuming that shear strength in the HPFRC coupling beams is provided by the HPFRC material and hoops, the calculated shear stress demand on the HPFRC material in the middle portion of the beam, assuming yielding of the hoops, was 0.56 f " #, 0.22 f " #, and 0.30 f " # (MPa) for beams with span-to-overall depth ratios of 2.2, 2.75, and 3.3, respectively. ll three coupling beams were precast. This was intended to make the proposed design more flexible, as precast construction may prove more advantageous in certain conditions. s the connection between the coupling beam and the walls is more critical in precast construction, the same design can be applied to cast-in-place coupling beams. To prevent interference with the wall boundary reinforcement, the precast portion of the HPFRC coupling beams extended only to the wall cover (see shaded grey area in Figure 3). Longitudinal bars were extended beyond the precast portion of the beam a full development length for anchorage. U-shaped bar reinforcement crossing the beam-wall interface was used to force most of the beam inelastic deformations to occur away from the cold joint, preventing concentration of damage at the cold joint and thus, a premature sliding shear failure. 463

150 mm 1050 mm 95 mm 475 mm D13 - D16 D13 Hoops 75 mm - D10 Hoops spect Ratio of 2.2 150 mm D19 145 mm 1650 mm D16 600 mm D13 - D13 Hoops 75 mm - D13 Hoops spect Ratio of 2.75 150 mm D19 145 mm 1650 mm 500 mm D13 - D13 Hoops 75 mm - D13 Hoops spect Ratio of 3.3 Figure 3: Reinforcement details for test coupling beams. ll specimens discussed herein were constructed with a single HPFRC material containing high-strength hooked steel fibres in a 1.5% volume fraction. The fibres used were 30 mm long and 0.38 mm in diameter, made out of a wire with minimum tensile strength of 2300 MPa. The HPFRC mixture proportions by weight were 1:0.875:2.2:1.2:0.8:0.005:0.038 for cement:fly ash:sand:course aggregate:water:high-range water reducing agent:viscosity modifying agent. The course aggregate was crushed limestone with a maximum size of 13 mm. This HPFRC mixture exhibited high workability, so only minimum vibration was required during casting. Detailed information about this mixture can be found elsewhere (Liao et al., 2006). s shown in Table 1, the compressive strength of this HPFRC mix, obtained from tests of 100 x 200 mm cylinders, was 63 MPa for the coupling beam with an aspect ratio of 2.2, and 68 MPa for the other two test coupling beams. 464

Table 1: Summary of test results l n /h b, mm h, mm f c *, MPa V max, kn V max / (bh f c ), Drift MPa Capacity** 2.2 150 475 63 570 1.00 5.8 % 2.75 150 600 68 540 0.73 5.7 % 3.3 150 500 68 500 0.81 6.8 % * Concrete cylinder compressive strength at test day. ** Largest drift achieved in both directions with less than 20% strength loss b: thickness; h: overall depth; V max : maximum shear Figure 4: (a) (b) Proposed tensile test: (a) specimen details; (b) sample result. 2.2 Tensile and flexural behaviour of HPFRC There is no standardized tensile test protocol for fibre-reinforced concrete. This is due primarily to difficulties associated with connecting a material specimen sufficiently large to be representative of field conditions to conventional testing equipment. There is also no agreement among researchers about the proper boundary conditions for such a specimen. tensile test developed by co-writers Parra-Montesinos, Lequesne, and Conforti was used to evaluate the tensile behaviour of an HPFRC with the same matrix mixture proportions, fibre type, and fibre content as that used in the test coupling beams. This test can be conducted using standard reinforcing bar test equipment and largely diminishes fibre alignment due to edge effects. The test specimens consisted of a 150 by 150 by 350 mm FRC prism with an embedded 19 mm reinforcing bar used for loading purposes (Figure 4a). The reinforcing bar was pre-cut in order to make it discontinuous at the centre of the specimen in order to reduce restraint against shrinkage. 19 mm deep notch was sawn prior to testing around the perimeter of the specimen, at a location coinciding with the cut in the reinforcing bar. Tests in which the reinforcing bar was continuous were also conducted in order to better study the interaction between reinforcing steel and cracked FRC. The uncertainty in the estimation of the effect of stresses induced by restrained shrinkage on specimen behaviour, however, made the use of data from these continuous bar tests questionable. 465

For testing (Figure 4a), the reinforcing bars protruding from the ends of the FRC prism were held by standard bar grips. Specimens were loaded at a rate of 0.002 mm/s until cracking, followed by a rate of 0.006 mm/s until the average crack width exceeded 5 mm. Non-contact infrared-based instrumentation was used to determine crack widths. Figure 4b shows representative tensile stress versus average crack width responses obtained from specimens cast with the same concrete mixture used in the coupling beam tests. The specimens cracked at a stress that was typically between 2.3 and 3 MPa. The peak tensile strength, which was, on average, 30% higher than the first cracking strength, occurred at a crack width of approximately 0.5 mm. The fact that the peak stress was significantly higher than the first cracking stress indicates that this fibre-reinforced concrete was an HPFRC. HPFRC samples with dimensions of 150 by 150 by 500 mm were also subjected to thirdpoint flexural tests in accordance with STM C1609 (Figure 5a). Typical equivalent bending stress versus midspan deflection responses are shown in Figure 5b. Equivalent bending stress refers to the tensile stress calculated at the bottom of the section assuming linear elastic behaviour and uncracked section properties. Specimens consistently exhibited higher strength after first cracking, with peak strengths exceeding the first cracking strength by approximately 40%. The peak strength occurred at a midspan deflection of 0.9 mm on average. The predicted flexural responses that would be obtained by using the tensile stress vs. crack width data shown in Figure 4b would have trends similar to the behaviour shown in Figure 5b. However, the calculated equivalent flexural stresses would generally be greater, as the tensile stress versus crack width data were obtained from a notched specimen, while the STM C1609 beams were unnotched. Figure 5: (a) STM C1609 Flexural test: (a) schematic of test setup; (b) sample result. (b) 3 Results and discussion Figure 6 shows the average shear stress versus drift response for the three coupling beam specimens. verage shear stress was calculated as the applied shear divided by the beam cross sectional area. s shown in Figure 6, all three beams exhibited stable hysteresis up to drifts exceeding 5% (0.05 rad). No significant shear-related damage was observed in the middle region of the beam throughout the test, even though the peak shear stress ranged between 0.73 and 1.0 f " (MPa). It is worth mentioning that the maximum shear stress allowed in design in 466

Chapter 21 of the CI uilding Code (CI Committee 318, 2011) is 0.83 f " (MPa). Drift at failure, which was defined as the largest drift achieved in both directions prior to a loss of strength of 20% or greater was close to 6% for the beams with an aspect ratio of 2.2 and 2.75, and slightly less than 7% for the beam with a 3.3 aspect ratio. summary of the beam test results is shown in Table 1. 8 6 4 Shear Stress (MPa) 2 0-2 - 4-6 spect Ratio = 2.2 spect Ratio = 2.75 spect Ratio = 3.3-8 - 10-8 - 6-4 - 2 0 2 4 6 8 10 Drift (%) Figure 6: Shear stress versus drift behaviour for test specimens. Figure 7: Damage in coupling beam with aspect ratio of 3.3 at 3% (left) and 5% (right) drift. 467

Plastic deformations and damage in the coupling beams concentrated at the beam ends, but no concentration of damage occurred at the cold-joint between the precast HPFRC beam and the cast-in-place wall concrete, indicating that the intermediate reinforcement served the intended purpose of strengthening this interface and forcing most of the inelastic deformations within the beam span. Failure of the coupling beams was caused by the development of wide flexural cracks, along which sliding deformations developed, leading to a significant loss of stiffness and strength. t coupling beam drifts of approximately 4%, however, damage in the coupling beams was relatively modest, which indicates that the HPFRC coupling beams are highly tolerant to large inelastic deformations. Figure 7 shows damage in the coupling beam with an aspect ratio of 3.3 at 3 and 5% drift. 4 Use of HPFRC coupling beams in a high-rise structure The coupling beam design shown in Figure 3 was implemented in a high-rise building in the city of Seattle, W, US. The building, The Martin (Figure 8), is a 73 m tall, 24-story corewall structure designed by Cary Kopczynski & Co from ellevue, W, US. pproval of the use of HPFRC coupling beams was achieved through a peer-review process. Results from the tests described above were used as the basis for analysis and design. ecause approval from building officials was obtained after construction had begun, the HPFRC coupling beam design was implemented from the 12 th floor up. Each floor level had five coupling beams and each HPFRC coupling beam had a 76 x 46 cm cross section, with a span length of 1.3 m for a span-to-height ratio of 2.8. Only longitudinal and transverse reinforcement was used in the beams (i.e., no diagonal bars), as in the test specimens discussed herein, which substantially facilitated construction. Design shear stresses in the coupling beams ranged from 0.33 f " to 0.71 f " (MPa) and transverse steel in the middle portion of the beam was designed such that the shear stress demand in the HPFRC material would not exceed 0.29 f ", MPa. This was consistent with the coupling beams tested. s in the test specimens, special column-type confinement reinforcement was provided over half the beam depth from each beam end. Longitudinal reinforcement ranged from 5-No. 22M bars top and bottom for the coupling beams with lower shear stress demands to 3-No. 35M + 3-No. 32M top and bottom. Specified concrete strength ranged between 41 and 69 MPa. Ready-mix fibre-reinforced concrete was used, with the fibres added at the concrete plant. The fibres were of the same type (high-strength hooked steel fibres) and used in the same dosage (1.5% volume fraction) as in the test specimens. Prior to addition of fibres, the mixture used exhibited self-consolidating properties. To verify that adequate fibre distribution could be achieved, small samples were cast and cut after hardening of concrete for visual inspection. photo of fresh fibre-reinforced concrete used in the coupling beams is shown in Figure 9a. Rather than using a precast operation as in the experimental program, the coupling beams were cast-in-place, using a crane and bucket operation (Figure 9b). Given the fact that the HPFRC material did not penetrate into the core of the wall boundary region, intermediate reinforcement was used as in the precast coupling beams to force most of the inelastic deformations to occur away from the cold joint and thus prevent a premature sliding shear failure. Overall, the construction of cast-in-place HPFRC coupling beams proved to be a very practical and successful operation. 468

Figure 8: The Martin, a core-wall structure with HPFRC coupling beams in Seattle, W, US. Figure 9: (a) (b) (a) Fibre distribution in fresh fibre-reinforced concrete used in The Martin building (fibre length: 30 mm); (b) casting of fibre-reinforced concrete coupling beam in The Martin building. 5 Conclusions Results from tests of large-scale coupling beams under simulated earthquake-induced displacements proved that a complete elimination of diagonal bars and a substantial reduction in confinement reinforcement is possible in coupling beams constructed with a highperformance fibre-reinforced concrete (HPFRC) and with span-to-overall depth ratios greater than or equal to 2.2. The behaviour of the test specimens was governed by flexural yielding at the beam ends with little shear-related damage. Ultimate failure of the coupling beams was caused by sliding along wide flexural cracks at the beam ends, but at coupling beam drifts greater than 5%. 469

The elimination of diagonal bars and reduction in transverse reinforcement proved to be advantageous from a construction viewpoint, as evidenced by the experience in the construction of a high-rise building in the city of Seattle, W, US, where cast-in-place HPFRC coupling beams were used. For evaluation of the tensile behaviour of HPFRC mixtures, tensile tests on 150 x 150 x 350 mm notched prisms with an embedded bar discontinuous at the notched section proved to be simple and gave consistent results up to crack widths as large as 5 mm. This tensile test can be conducted using standard reinforcing bar test equipment and largely diminishes fibre alignment due to edge effects by allowing the testing of large prisms. 6 References CI Committee 318. uilding Code Requirements for Structural Concrete (CI 318-11). merican Concrete Institute, Farmington Hills, MI, 2011. STM C1609/C1609M-12, Standard Test Method for Flexural Performance of Fiber- Reinforced Concrete (Using eam with Third-Point Loading), STM International, West Conshohocken, P, 2012. Canbolat,..; Parra-Montesinos, G.J.; Wight, J.K. (2005). Experimental study on seismic behavior of high-performance fiber-reinforced cement composite coupling beams, CI Structural Journal, Vol. 102, No. 1, pp. 159-166. Lequesne, R.D. (2011). ehavior and design of high-performance fiber-reinforced concrete coupling beams and coupled-wall systems, PhD. Dissertation, University of Michigan, nn rbor, MI. Lequesne, R.D.; Parra-Montesinos, G.J.; Wight, J.K. (2013). Seismic behavior and detailing of high-performance fiber reinforced concrete coupling beams and coupled wall systems, SCE Journal of Structural Engineering, Vol. 139, No. 8, pp. 1362-1370. Liao, W.-C.; Chao, S.-H.; Park, S.-Y.; Naaman,.E. (2006). Self-consolidating highperformance fiber-reinforced concrete (SCHPFRC) Preliminary investigation. Report No. UMCEE 06-02, University of Michigan, nn rbor, MI. Naish, D.; Fry, J..; Klemencic, R.; Wallace, J. (2009). Reinforced concrete link beams: lternative details for improved constructability. Report to Charles Pankow Foundation, UCL-SGEL, University of California at Los ngeles. Parra-Montesinos, G.J.; Wight, J.K.; Setkit, M. (2010). Earthquake-resistant coupling beams without diagonal reinforcement. Concrete International, merican Concrete Institute, Vol. 32, No. 12, pp. 36-40. Paulay, T.; inney, J.R. (1974). Diagonally reinforced coupling beams of shear walls. Shear in Reinforced Concrete, Special Publication 42, merican Concrete Institute: Detroit, MI, pp. 579-598. Setkit, M. (2012). Seismic ehavior of slender coupling beams constructed with highperformance fiber-reinforced concrete, PhD. Dissertation, University of Michigan, nn rbor, MI. 470