Cementitious Concrete Repair Mortar

Similar documents
R4 Fast Setting Cementitious Repair Mortar

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG

R4 Hand Placed / Wet Spray Repair Microconcrete

R4 Hand Placed / Wet Spray Repair Microconcrete

EN R4 High Strength High Build Concrete Repair Mortar

Product Data Sheet Product Description Uses Characteristics / Advantages Tests Approval / Standards Product Data Construction Form

Construction. R4 Low Resistivity Dry Sprayed Repair Concrete. Product Description. Product Data. Tests. Form. Storage

Bonding Primer and Reinforcement Corrosion Protection

R3 Cementitious Pore Sealer and Levelling Mortar

3-part thixotropic epoxy patching mortar

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

Product Data Sheet Product n Description Uses tio tru Characteristics / C Advantages Tests Approval / Standards

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

CONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray Applications

PRODUCT DATA SHEET Sika MonoTop Dynamic HP

2-part water dispersed epoxy coating

PRODUCT DATA SHEET Sikadur -32 Normal

Waterproofing and Damp-proofing Cementitious Slurry

Sikadur -Combiflex CF Adhesive Type N and Type R are thixotropic two part adhesives based on epoxy resins and fillers.

High strength fibre reinforced structural repair mortar

Product Data Sheet Product Description tio Uses tru n Characteristics / Advantages

Construction. Adhesive for bonding Carbon Fibre & Steel reinforcement. Product Description. Tests

PRODUCT DATA SHEET Sika Galvashield XP

TECHNICAL DATA SHEET SIKALASTIC-1K

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

Non-metallic dry shake floor hardener

High performance, flexible cementitious tile adhesive for thin bed application

2-part epoxy impregnation resin

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

3-component epoxy self-smoothing screed

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

1-part polyurethane pourable self levelling floor joint sealant

Sikadur -31 DW Rapid (VP)

3-Part Epoxy Grouting System for Pile Capping

Swellable joint sealing profiles

PRODUCT DATA SHEET Sikadur -31 DW

1-part elastic joint sealant and multipurpose adhesive

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

TECHNICAL DATA SHEET SIKA ANCHORFIX-1 GREY 300ML (6's)

Construction. Cementitious self levelling, fast hardening, underlayment for use 2-10mm, and 10-30mm with added aggregate. Product Description

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

1-part elastic joint sealant and multipurpose adhesive

PRODUCT DATA SHEET Sikafloor -81 EpoCem New HC

CHARACTERISTICS / ADVANTAGES

EN 14891:2012/AC:2012

Sikadur -330 is a two part, thixotropic epoxy based impregnating resin / adhesive.

PVC profile waterstops for joint sealing

Construction. 2-part water based protective epoxy coating. Product Description. Product Data. Tests. Form

2-part, electrostatically conductive epoxy coating

Liquid applied polyurea hybrid membrane

2-part self smoothing epoxy coating, highly chemically and mechanically resistant

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

Appearance /Colours Resin - part A: transparent, liquid Hardener - part B: transparent, liquid Packaging. Pre-proportioned 5.

Construction. Corrosion inhibiting impregnation (improved formulation) Product Description. Product Data Sheet Edition _1

PRODUCT DATA SHEET SikaGrout -312 HP

2-part epoxy impregnation resin

SITE HANDBOOK. Repair of Concrete Structures. - Patch Repair and Spray Applications

PRODUCT DATA SHEET Sikagard -720 EpoCem

PRODUCT DATA SHEET Sikadur -42 HE

TECHNICAL DATA SHEET SIKALEVEL 25 LATEX SELF LEVELLING 25KG

Construction. Sika FerroGard Method Statement for Application Corporate Construction. Scope:

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

1-part PUR highly elastic coating

PRODUCT DATA SHEET Sika Level-315 F

TECHNICAL DATA SHEET SIKAFLEX FLOOR

Author: M Shaw, Sika Limited. Construction. A Guide to the Concrete Repair European Standards BS EN 1504 Series

Construction. Type N and Type R. 2-part epoxy adhesive Part of the Sikadur -Combiflex System. Product Description

Construction. Sikafloor -2 SynTop-2. Non-rusting hard aggregates dry shake floor hardener. Product Description. Product Data. Uses

Protective coating for exposed concrete

Section Shotcrete

Construction. 1-part elastic joint sealant and multipurpose adhesive. Product Description

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

DIVISION 3 CONCRETE Section Concrete Rehabilitation

TECHNICAL DATA SHEET SIKABOND-54 WOOD FLOOR 6KG (3pack=18KG)

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

Construction. Type N and Type R. 2-part epoxy adhesive Part of the Sikadur -Combiflex System. Product Description. Tests

Segmental bridge adhesive

Construction. 2-part epoxy impregnation resin. Product Description. Product Data. Tests. Form. Product Data Sheet Edition 4 March 2015

Sikafloor -264 is a two part, economic, solvent-free coloured epoxy resin, suitable for use under hot climate condition.

2-part epoxy primer, levelling mortar and mortar screed

Low viscous (easy flowing) elastic adhesive for wood flooring

2-part Epoxy coating and seal coat

PRODUCT DATA SHEET Sika Levelling Compound

Construction. 2-part epoxy primer. Product Data

Highly Chemical Resistant Laminate System. Sika Asplit VEL is 2 part, glass fabric reinforced, vinyl-ester based coating and lining system.

PRODUCT DATA SHEET Sikafloor -82 EpoCem

Construction. SikaTop 111 Plus. Application Instructions. Sika Corporation

2-part PUR tough elastic, crack-bridging coating

Water resistant bonding agent and mortar additive

Epoxy resin MIO + polyurethane

Fast curing epoxy resins + polyurethane

Construction. Coloured mineral dry shake floor hardener. Product Description. Product Data. Tests. Form. Storage

Construction. 2-part epoxy impregnation resin. 1 Sikadur /5. Product Data Sheet Edition No. 01 (October 2015) Sikadur -330.

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

PRODUCT DATA SHEET Sikafloor -81 EpoCem

Construction. 2-part epoxy impregnation resin. 1 Sikadur /6

PRODUCT DATA SHEET SikaTop -111 Plus

Transcription:

Product Data Sheet Edition 08/05/2012 Identification no: 02 03 02 04 005 0 000009 SikaTop -122 Cementitious Concrete Repair Mortar Construction Product Description SikaTop -122 is a two component polymer modified cement based fibre reinforced concrete waterproof repair mortar. Uses For repairing all types of concrete Characteristics / Advantages Product Data Form Appearance /Colours Packaging For high strength repairs Repairs to floors Horizontal and vertical repairs Hand applied repairs For exterior and interior use Pre-batched for quality Fast and easy to apply No water required Free of chloride ions Cement grey (Component A: white liquid, Component B: grey powder) 25kg and 10kg bags Storage Storage Conditions/ Shelf-Life 9 months from date of production if stored properly in original unopened, sealed and undamaged packaging in dry and cool conditions. Technical Data Chemical Base Density Grading Layer Thickness Portland cement, polymer redispersable liquid, selected aggregates and additives and microfibres. Fresh mortar density: ~ 2.1 kg/l D max: 1.5 mm 4.0 mm min. / 20 mm max. (vertical) / 75 mm max. (horizontal if bulked out) 1 1/5

Mechanical / Physical Properties Compressive Strength 28 days > 55 N/mm 2 Flexural Tensile Strength 28 days ~ 10-12 N/mm 2 Bond Strength E-Modulus 19.3 kn/mm 2 ~ 1.0-3.0 N/mm 2 (substrate failure with Bonding Primer) System Information System Structure SikaTop 122 is part of the SikaTop Concrete Repair System. SikaTop Armatec-110 EpoCem: Reinforcement coating SikaTop -121: Bonding primer SikaTop -122: Hand applied repair mortar SikaTop -122HB: High build hand applied repair mortar SikaTop -121: Smoothing coat Sika FerroGard - 903: Corrosion inhibitor Application Details Consumption This depends on the substrate roughness and thickness of layer applied. As a guide, ~ 2.1 kg/m 2 /mm. 2 2/5

Substrate Quality Concrete The concrete shall be free from dust, loose material, surface contamination and materials which reduce bond or prevent suction or wetting by repair materials. Steel reinforcement Rust, scale, mortar, concrete, dust and other loose and deleterious material which reduces bond or contributes to corrosion shall be removed to a minimum standard of SA2½. Reference should also be made to BS EN1504-10:2003 for specific requirements. Substrate Preparation / Bonding Primer/ Reinforcement Coating Concrete: Delaminated, weak, damaged and deteriorated concrete and where necessary sound concrete shall be removed by suitable mechanical or very high pressure waterblasting [up to 110 mpa (16500 psi)] techniques. Tying wire fragments, nails and other metal debris embedded in the concrete should be removed where possible. The edges where concrete is removed should be cut at a minimum angle of 90 o to avoid undercutting and a maximum angle of 135 o to reduce the possibility of debonding with the top surface of the adjacent sound concrete and should be roughened sufficiently to provide a mechanical key between the original material and SikaTop -122. Ensure sufficient concrete is removed from around reinforcement to allow coating and compaction of the repair material. Steel reinforcement: Surfaces should be prepared using abrasive blast cleaning techniques or high pressure waterblasting [up to 60 mpa (9000 psi)] techniques. Where exposed reinforcement is contaminated with chloride or other material which may cause corrosion, the reinforcement shall be cleaned by low pressure waterblasting [up to 18 mpa (2700 psi)]. Bonding primer: On a well prepared and roughened substrate a bonding primer is generally not required. When a bonding primer is not required pre-wet the surface. The surface should not be allowed to dry before application of the concrete repair mortar. The surface should achieve a dark matt appearance without glistening and surface pores and pits should not contain water. When a bonding primer is necessary apply SikaTop -121 or SikaTop Armatec-110 EpoCem (Refer to the relevant Product Data Sheets). Site adhesion values - Structural Repair 1.2-1.5 mpa Non Structural repairs minimum value 0.7 mpa Reinforcement coating: Where a reinforcement coating is required as a barrier, apply to the whole exposed circumference two coats of SikaTop Armatec-110 EpoCem. (Refer to the relevant Product Data Sheet). Reference should also be made to BS EN1504-10:2003 for specific requirements. Application Conditions / Limitations Substrate Temperature Air Temperature +8 C min. / +30 C max. +8 C min. / +30 C max. 3 3/5

Application Instructions Mixing Mixing Time Application Method / Tools Cleaning of Tools Potlife Notes on Application / Limitations Mix together both Components A (liquid) and B (powder). Shake component A before using. Pour approximately ½ component A into mixing container and add component B slowly while mixing. When homogeneous, add the remainder of the component A and remix. Normal mixing time depends on the type of mixer used, 2-3 minutes is average. Mix so as to entrain as little air as possible and use without delay. When mixed, the produce may be bulked out with dry, dust free aggregate (40% by wt of 3-6 mm granite chippings) and remixed to a uniform consistency. Hand Applied If a bonding primer has been used apply repair mortar wet on wet. The repair mortar shall be worked into the prepared pre-wetted substrate between the minimum and maximum layer thicknesses and shall be compacted without inclusion of entrapped air pockets using a trowel or gloved hand. Where layers are to be built up to prevent sagging or slumping, each layer should be allowed to stiffen before applying subsequent layers wet on wet. When layers cannot be applied wet on wet, or if more than 6 hours between layers apply a bonding primer of SikaTop -121 or SikaTop Armatec-110 EpoCem and apply repair mortar wet on wet. Reference shall be made to BS EN1504-10:2003 for specific requirements. Clean all tools and application equipment with water immediately after use. Hardened/cured material can only be mechanically removed. ~ 30 minutes (at +20 C) Avoid application in direct sun and/or strong wind and/or rain. Do not add water. Apply only to sound, prepared substrates. Do not add water during the surface finishing as this will cause discoloration and cracking. Protect freshly applied material from freezing. Curing Details Curing Treatment Value Base It is essential to cure the repair mortar immediately after application for a minimum of 3-5 days to ensure full cement hydration and to minimise cracking. Use polythene sheeting taped down at the edges or other approved method. Curing compounds shall not be used when they adversely affect subsequently applied products and systems. Reference shall also be made to BS EN1504-10:2003 for specific requirements. All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. Health and Safety Information For information and advice on the safe handling, storage and disposal of chemical products, users should refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. 4 4/5

Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Construction Sika Limited Watchmead Welwyn Garden City Hertfordshire AL7 1BQ United Kingdom Phone +44 1707 394444 Telefax +44 1707 329129 www.sika.co.uk email: sales@uk.sika.com Certificate No. EMS 4308 Certificate No. FM 12504 5 5/5