Three-Story Victorian Partial Retrofit. Overview. Case Study

Similar documents
National Grid Deep Energy Retrofit Pilot Program Cape Basement Renovation Turned Comprehensive DER

National Grid Deep Energy Retrofit Pilot Program Two-Family Belmont Residence

National Grid Deep Energy Retrofit Pilot Program Millbury Cape

National Grid Deep Energy Retrofit Pilot Program Comprehensive DER of Three-Family Triple Decker

National Grid Deep Energy Retrofit Pilot Program Second Floor Reframing Comprehensive Retrofit of 19 th Century Small Colonial

Bedford Farmhouse High Performance Retrofit Prototype

Water control Vapor control and drying Room for growth

Overview. Historic Preservation Meets Building Science: The Mallett Deep Energy Retrofit. R-Value Targets. The Mallett Deep Energy Retrofit

ENCLOSURE: SIMPLE LAYERS

Pulling it all together: Deep Energy Retrofit Measures Verification. Deep Energy Retrofit Measures

Hamilton Way - Case Study of a High Performance Community in a Cold Climate

Deep Energy Retrofit is a path to ZNE How does all of this support zero netenergy

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

What Would I do? Building Energy Use. Assessing the Impact of US Housing

WeatherSmart Air Barrier Installation Guide

DER Workshop September 13, 2011

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in)

Thermal Remodeling Wasilla, Alaska. Harvey Bowers

1.1 BUILDING DESCRIPTION:

5. SANDSTONE, ELLENDALE, DE

GAF EnergyGuard Polyiso Wall Sheathing

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80

Is Yours? Homes Across Missouri are built to National Energy Efficiency Standards

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016


buildingscience.com buildingscience.com buildingscience.com buildingscience.com buildingscience.com Key Partners/Products buildingscience.

A Practical Look at Retrofits. Deep-Energy

The Nottingham Ecohome. Part L1 (2002) in existing dwellings

Metro Community College January 27-28, Building Science Corporation

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

Northeast Sustainable Energy Association G338

Feature Zone IECC 2009 IECC

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?

Building Enclosure Design Fundamentals, Components, and Assemblies

Installation Guidelines

HOUSE DETAILS House Plan with dimensions (From House Website) First Floor Plan

Administrative Changes

Energy Provisions of the Residential Building Code IECC: Guide for Homeowners

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

R-Matte Plus-3: Insulation for the Building Envelope

2014 British Columbia Building Code Changes

Westford House. Westford House. Building America for Cold Climates: Westford, MA. Westford, MA. Project Overview

Construction Report NYSERDA Residential Performance Challenge

Where to Draw the Line with Thermal Boundaries

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

Henri Fennell, CSI/CDT ABX 2015

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

DOE Zero Energy Ready Home Technical Training

Energy Efficiency Requirements 9.36

Building Envelopes 101

Sloped Roofs vs Walls. Problems. Review Roof Components. University of Waterloo and Balanced Solutions

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

A. GENERAL INFORMATION

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

FirstEnergy Program Overview

Multi-family Passive House Rehabilitation

SINGLE FAMILY PASSIVE HOUSE case studies

Thermal Control Layers: Insulation Materials and Systems

The Role of Control Layers in Building Enclosure Design

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Is Yours? Homes Across Missouri are built to National Energy Efficiency Standards

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

and the new 2013 Title 24 Energy Standards

BUILDING ENCLOSURE AIR TIGHTNESS TESTING Course Number: BCLUNA018-01P

Energy Provisions of the Kentucky Residential Code. Guide for Homeowners

Chapter 14 - Air Sealing

Hardin County Planning and Development Commission

Assessing the Impact of US Housing. Retrofits. Building Carbon Emissions. Building Energy Use. buildingscience.com

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Spray Foam and the Building Codes

Energy Star Qualified - New Homes

3/24/2017. Kohta Ueno. Building Science of Walls. March 24, Background Rhode Island AIA Presentation 2

The better way to build TM. Installation Manual NAILBASE PANELS

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

IRC 2012 Key Changes

1. 18 WILLIAMS AVE, WESTFORD, MA & 130 NORTH ROAD, BEDFORD, MA

Air Sealing for 5 ACH 50

Background Basement Thermal Behavior

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. Adding insulation

Work Order (Bid Form) Upper East Tennessee Human Development Agency

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Net Zero Building Enclosure Retrofits for Houses: An Analysis of Retrofit Strategies

Home Energy Score Report

Ducts in Conditioned Space High Performance Attics

Boulder City NV Prepared by (Print Name) Signature Date

ENERGY SAVINGS FOR LIFE

Revised January buildingscience.com. Water Management Details. Housewraps/Flashings/Windows buildingscience.com

Plan /Submission Requirements

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Supplementary Standard SB-12. Energy Efficiency For Housing

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

Transcription:

Case Study National Grid Deep Energy Retrofit Pilot Program Three-Story Victorian Partial Retrofit Brookline, Massachusetts Overview The owners of this single family Victorian had previously gone through a retrofit in the spring of 009. The upgrades included adding closed-cell spray foam insulation to the underside of the replacement roof as well as to the existing field stone foundation walls. Work had been also done to modernize the radiant hydronic heating distribution system, which was originally steam. With the financial and technical support offered through National Grid s Deep Energy Retrofit Pilot Program the owners decided to continue making the improvements to the house and incorporate a deep energy retrofit (DER) to the remaining parts of the house. The present retrofit project for this home includes addition of exterior wall insulation and high performance triple-pane windows, air sealing to connect the new and previous retrofit measures, replacement of heating and water heating equipment, and provision of mechanical ventilation. This home provides an example of a staged approach to a comprehensive retrofit. New retrofit measures are carefully thought out and integrated with the measures implemented previously. This staged approach may be a more realistically accessible path to broad adoption of DER. The nature of the retrofit work in this present phase of the larger project imposed minimal disruption to the interior. Project Profile Project Team: Synergy Construction, Builder and DER Lead; Building Science Corporation, Consultants and DER Technical Support; National Grid, Massachusetts, DER Pilot Program Administrator/Sponsor Location: Brookline, Massachusetts Description:,078 ft four bedroom, three bathroom, ½ stories plus a full basement single family Victorian Completion Date: November 0 Estimated Annual Energy Savings: Projected 7% energy use reduction compared to pre-retrofit conditions /0 buildingscience.com

National Grid Deep Energy Retrofit Pilot Program: Three-Story Victorian Retrofit Builder Profile Design Parametric Study of Source Energy Use Synergy Construction specializes in zero and low energy new construction, Deep Energy Retrofits, remodeling, customized efficient insulating, weatherproofing and solar energy systems for both residential and commercial projects. Participating Programs & Certifications U.S. Department of Energy s Building America Program U.S. Environmental Protection Agency ENERGY STAR Program Deep Energy Retrofit Pilot Program For more information, go to www.powerofaction.com/der Image from BSC generated by NREL s BEOpt. for retrofits To build upon the direction set by previous work, the current enclosure retrofit project for this test home focuses on the above-grade walls and windows. The existing composite of vinyl siding and original wood siding were showing signs of deterioration. The DER plan for this test home involved striping the above grade walls to the sheathing, repairing sheathing as needed, then establishing control layers to the exterior of the sheathing. Thus, even without the super-insulation measures, the wall retrofit significantly improved the performance and durability of the wall system. To provide generous protection for the walls and also to maintain the refined period aesthetics of the home, the plan also involved extending the roof eaves. The roof eaves had not been extended as part of the previous project in which the roof was addressed. The project team and owners deliberated for some time whether to replace the windows. The existing windows had been installed relatively recently (within years) and offered reasonable thermal performance. Ultimately the owners decided to replace the windows in order to provide for better integration with water management and to capture the incremental performance benefits. The rather tall configuration of the home and the fact that the project did not include replacement of interior finishes presented a challenge to design of new distribution. Aesthetics, geometry of the house, cost as well as proper sizing of the units were the factors in the selecting the equipment and installation approaches. The owners considered adding cooling to the house but in the end they decided against it.

National Grid Deep Energy Retrofit Pilot Program: Three-Story Victorian Retrofit Enclosure Design uroof Assembly: Retrofit measures completed in the previous enclosure retrofit; R-8 (nominal): Unvented roof assembly with 8 of closed-cell spray foam between the rafters; ½ plywood; fully-adhered membrane; asphalt shingles. vwall Assembly: R-0 (nominal): Existing dense-packed cellulose insulation in wall framing cavities; housewrap over existing board sheathing, sealed at perimeter and all penetrations with seams taped; two layers of foil-faced polyisocyanurate insulating sheathing; ¾ furring strips; wood siding. wwindow Specifications: New Paradigm triple-glazed, krypton/ argon blend gas, low-e vinyl windows, U=0.0, SHGC=0.; windows installed in alignment with drainage plane. xinfiltration: Sealant applied between housewrap and existing board sheathing at top and bottom of wall; sealant between successive layers at bottom of wall transitions airflow control to foundation airflow control of previous work; taped insulating sheathing with joints offset; two-part foam applied at the top of insulating sheathing to connect to closed-cell spray foam of previous work. yfoundation Assembly: Retrofit measures completed in the previous enclosure retrofit; closed-cell spray foam applied directly onto the existing field stone foundation walls; gypsum wall board thermal barrier on / 8 metal studs partially embedded in closed-cell spray foam; 7 closed-cell spray foam at sill beam with a layer of rigid mineral wool insulation; slab remained uninsulated.

National Grid Deep Energy Retrofit Pilot Program: Three-Story Victorian Retrofit Mechanical Design uheating: Buderus condensing boiler located in the basement for hot water radiators. The owners chose not to install cooling. vventilation: Imperial Heat Recovery Ventilator (HRV) located in the basement. Ventilation supply ducted to living and dining room and hallways, stale air exhausted from bedrooms. Point source ventilation from kitchen and bathrooms. wspace Conditioning Distribution: Ventilation ductwork and hydronic distribution located entirely within the conditioned space. xdhw: SuperStor Ultra hot water storage tank connected to the boiler located in the basement. ylighting: Combination of CFL and incandescent light bulbs in light fixtures. Appliances: ENERGY STAR appliances. Construction The builder demonstrated an innovative approach with the installation of the windows in alignment with the drainage plane of the wall. Wood blocking let in to exterior layer of insulation is covered by self-adhered flashing that wraps into the opening over the wood blocking and inner layer of insulating sheathing. Since the insulated sheathing used is thick, the blocking is padded to the inside with of rigid foam insulation. The blocking is fastened to the wall framing through the inner layer of exterior insulating sheathing. Positive drainage of the window sill pan flashing is established by cutting the foam at the bottom of the window to provide a slope. With the opening prepared, the window is installed and flashed as per typical practice with fasteners into the x blocking through the nailing flanges. This project demonstrated robust means of maintaining continuity of the water, air and thermal control at attached porch roof and porch deck connections by temporarily supporting the structures, cutting them back from the wall, installing the air, water and thermal control layers, then re-attaching the structures over these layers. The continuous airflow control layers enabled by this measure likely contributed to strong air leakage reduction.

National Grid Deep Energy Retrofit Pilot Program: Three-Story Victorian Retrofit Testing and On-Site Technical Support BSC was able to assist the builder with technical issues through both on-site visits and remote support. Ventilation strategies were discussed in order to work out the best approach for providing ventilation in this circa 900 house. Aesthetics and geometry of the house played a significant role in selecting the right equipment and finishes as well as Moving Forward developing an appropriate approach for distributing the ductwork. BSC performed a pre- and post-retrofit air leakage testing to determine the improvement in the air leakage of the whole house. The pre-retrofit air leakage measurement was 67 CFM @0 Pa (.80 ACH 0) and the postretrofit measurement was 6 CFM @0 Pa (.0 ACH 0). Monthly gas and electric bills will be collected from the homeowner to gauge performance of the retrofit strategies employed. The builder for this project had completed several DER projects prior to this one and demonstrated acumen in developing various improvements in retrofit strategies. The builder continued to do so in the present DER retrofit project. Certainly, the retrofit approaches will keep evolving in the several future DER projects that are in store for the builder. Design Challenge: Doubling Efforts This project presented interesting challenges of connecting the control functions of an exterior wall retrofit system to previous retrofit work. At the front of the building is an overhanging floor where the previous retrofit had applied closed-cell SPF. The exterior insulating sheathing added as part of the current retrofit was applied to the face of the wall and continuous through the location where the porch roof had been cut away. As seen in the photo to the right, the use of two-part kit foam does not appear to have successfully connected the new work to the previous work at the first attempt. A second application of two-part foam was needed to provide robust connections. For more information about this or other case studies by Building Science Corporation and the Building America Program go to: www.buildingscienceconsulting.com/ services/building-america.aspx This case study has been prepared by Building Science Corporation for the Department of Energy s Building America Program, a private/ public partnership that develops energy solutions for new and existing homes. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. For more information about Building America go to www.buildingamerica.gov