Questar Gas Company - ThermWise

Similar documents
Home Energy Savings Program. Utah Participating Weatherization Trade Ally Program Manual

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Questar ThermWise Duct Technical Specifications

Table Air Barrier and Insulation Inspection Component Criteria

Hardin County Planning and Development Commission

Charter Township of Washington

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Feature Zone IECC 2009 IECC

2016 RESIDENTIAL WEATHERIZATION SPECIFICATIONS

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Air Sealing for 5 ACH 50

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

IRC 2012 Key Changes

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Work Order (Bid Form) Upper East Tennessee Human Development Agency, Inc.

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

2018 WEATHERIZATION SPECIFICATIONS MANUAL

RESIDENTIAL MECHANICAL/FIREPLACE

Project Name: Enforcement Agency: Permit Number:

Michigan Energy Code Training and Implementation Program

APPLICATION FOR FINISHED BASEMENT PERMIT

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

Radon Vent Pipe System. Labeling Performance Indicators

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Boulder City NV Prepared by (Print Name) Signature Date

Air Sealing, Infiltration & Ventilation

FIELD COPY ATTACHMENT

Project Type: New Home Addition Alteration (Describe)

REScheck Software Version Compliance Certificate

A.ENVELOPE AIR SEALING

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Prescriptive Checklist for the 2015 Washington State Energy Code

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Presented by: Stephen Carr Regional Building Science Manager (386)

Presented by: Stephen Carr Regional Building Science Manager (386)

SUSTAINABLE ENERGY ANALYTICS

Advanced Ventilation for Residential applications FBC Res 2010.

10 Steps to Save Energy in Your House

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

Standards for Jackson EMC s Right Choice Program Revised: June 2011

Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

IECC Residential Significant Changes Summary. Tier I

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

2012 IECC Residential with State Adopted Changes

Measure 1 Seal Ducts Components Inspected

Standard practice for installing cellulose building insulation

2017 SPECIFICATIONS MANUAL ENERGY TRUST OF OREGON EXISTING HOMES

2010 National Building Code Adoption and Associated Process Changes

currently referenced throughout the

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?

Is Yours? Homes Across Missouri are built to National Energy Efficiency Standards

Energy Provisions of the Kentucky Residential Code. Guide for Homeowners

Air Leakage and Sealing

Work Order (Bid Form) Upper East Tennessee Human Development Agency

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Energy Provisions of the Residential Building Code IECC: Guide for Homeowners

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

BEST PRACTICE INSTALLATION STANDARDS

Home Energy Savings Program. Idaho Technical Specifications Manual

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Montana Homebuilder Brief: Residential Energy Code 1

2. Heat Transfer is quantified in British Thermal Units (BTU s)

A Protocol. Advanced Air Sealing

2014 British Columbia Building Code Changes

Property Inspection Checklist

Energy Efficiency Requirements 9.36

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Photographic Guide: Home Performance Dos and Don ts

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Overview of Presentation. Airflow Control: Why. Airflow Control: what kind?

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Home Energy Savings Program. Washington Technical Specifications Manual

Initial House Assessments & Sealing Options:

Section 22A. Lead Paint Risk Factor NONE-HIGH FLOOR INSULATION FOR CONVENTIONAL HOMES TABLE OF CONTENTS

ASHRAE 62.2: What s New in 2016

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Transcription:

Questar Gas Company - ThermWise WHOLE HOUSE AIR SEALING SPECIFICATIONS December 1, 2011 Index to Sections Section Page I. GENERAL SPECIFICATIONS 1 II. GENERAL MATERIAL SPECIFICATIONS 3 III. GENERAL REQUIREMENTS 4 IV. AIR SEALING AND TESTING 6 V. MECHANICAL VENTILATION 11

I. GENERAL SPECIFICATIONS 1. These specifications apply to existing residential (retro-fit) whole house air sealing for single family homes. Also applies to existing attached single family homes, that are on their own foundation and have their own roof (i.e., townhomes), in buildings consisting of four or less attached homes. Does apply to multi-family homes or apartment buildings. 2. Air sealing shall be installed in accordance with these specifications, all applicable State and local codes, and federal regulations. In cases where a federal, state or local code or regulation exceeds the requirements herein, that code or regulation shall apply. If the federal, state or local code or regulation does exceed the requirements herein, then the requirements contained in this specification shall apply. 3. All work shall be completed in a manner that will provide a safe, permanent, effective, and professional installation. 4. Whole House Mechanical Ventilation Compliance, see Section MV, is required on all projects.. Whole house air sealing includes a pre and post blower door test, and a measurement of building tightness. 5. All homes that have Whole House Air Sealing shall receive: a) Care for Your Air: A Guide to Indoor Air Quality, EPA b) Indoor Air Quality Homeowner Disclosure Form Whole House Air Sealing Specifications rev 12/01/11 Page 2 of 14

II. GENERAL MATERIAL SPECIFICATIONS 1. Materials used shall meet or exceed applicable local, state and federal codes and regulations. All materials shall be installed in accordance with manufacturer s instructions. 2. All materials shall be resistant to corrosion, degradation from ultraviolet light, and be compatible with other elements and materials (e.g. will react chemically, etc.) so as to enhance long life expectancy of installed measures. 3. Structural members and building components shall be free of decay and structurally sound before the weatherization measure is installed. 4. Weatherization materials, products and labor shall be warranted by the Installer against failure due to manufacturing and installation defects for a period of at least 1 year from the installation date. The Installer shall provide a written warranty, with the installation date, to the Homeowner or Homeowner Designee. Manufacturers' written warranties may be used by Installers to satisfy a part of this requirement where appropriate. 7. Caulking shall be one of the following materials conforming to the federal specifications listed below or material demonstrating equivalent performance in resiliency and durability. The cartridge or tube containing the caulking material shall be labeled indicating conformance to the applicable federal specification: a) Silicone Rubber TT-S-1543A b) Polysulfide or Polyurethane (single component) TT-S-230C c) Polysulfide or Polyurethane (multiple component) TT-S-227E d) Acrylic Terpolymer (single component) TT-S-230C e) Butyl Rubber TT-S-1657 f) Acrylic Latex ASTM C834 8. Installer Record The Installer of any measure covered by this specification manual shall provide a copy to the utility, and permanently post, an Installer Record, at the furnace, electrical panel or circuit box or other location approved by the homeowner as a record of work performed, containing the following information as applicable: a) Residence address. b) Installation date. c) Name, address and phone number of the Installer. d) Any air sealing that was completed, with final whole house leakage test results if applicable. List primary areas or building components that were air sealed. List any special conditions existing during leakage testing. e) List and describe any new fans or mechanical ventilation systems installed, including design airflow rate and control strategy. Whole House Air Sealing Specifications rev 12/01/11 Page 3 of 14

III. General Requirements 1. Combustion Appliance Exhaust Ventilation Inspection a) Combustion heating and water heating systems shall be visually inspected at accessible locations for readily apparent signs of improper venting and to observe that combustion vent flue terminates outdoors. Visual inspections shall be documented by contractor. b) Repairs shall be made prior to project completion to assure that exhaust venting at accessible locations is continuously connected between the appliance and outdoors ending in a code approved vent cap. c) Homeowners shall be ified of observed signs of improper venting, damaged venting, corrosion or deterioration of equipment or venting system and encouraged to contact a heating or water heating contractor or fuel utility for further inspection. d) Gas clothes dryers shall be vented to outside. e) Homes with unvented combustion heating appliances are eligible. 2. Carbon Monoxide Detectors All Carbon Monoxide Detectors shall: a) Be Underwriters Laboratories Tested and Listed to ANSI/UL 2034-09 b) Include an electrochemical sensor c) Be powered by long-life lithium type battery d) Include a digital readout that automatically displays the current CO level detected when an alarm signal is activated e) Include a data feature which is activated when the test/reset or memory button is pressed, and the readout shall include the current CO level detected down to 10 parts per million (ppm), the highest level detected down to 10 ppm, and for how long the peak level was detected Locked Battery Compartment a) Battery shall be factory pre-installed within a compartment which has a separate battery door that is locked closed with a tamper-resistant screw b) Battery compartment shall be accessible without removing alarm from its mounting Five-Year Warranty CO detector manufacturer shall warrant alarm and sensor for minimum 5 years, and shall guarantee that battery provided will power alarm for minimum 5 years without replacement Installation Requirements a) CO detector shall be installed in all family living units containing a permanently installed combustion appliance. b) CO detector installed in accordance to manufacturer installation instructions c) Detector shall be installed within unconditioned space, furnace closet or garage Occupant Education a) The CO detector shall be tested upon completion of installation, and the occupant shall be instructed how to operate, test and maintain the alarm b) The occupant shall be provided with the manufacturer s owner s manual 3. Interior Attic Access Doors a) Weather-stripping shall be permanently attached to create an effective air seal between the attic access frame and the door. Accesses with air leaks that can be weather-stripped shall be Whole House Air Sealing Specifications rev 12/01/11 Page 4 of 14

repaired or replaced prior to insulating. Ceiling accesses shall be insulated to at least R-30 with batt-type or rigid insulation. Alternatively, R-10 or greater rigid insulation securely attached to the top surface of the access cover is. Insulation must be sealed around the perimeter to the access cover using caulk, adhesive or spray foam. Access cover assembly must be tightly sealed using weather stripping around the entire perimeter. b) Batt-type insulation shall be attached to the door with twine. The twine shall be stapled to the edges of the door. Stapling the insulation directly to the door is unacceptable. Fibrous insulation must be covered with a vapor permeable air barrier material. c) Attic accesses shall be protected from having loose-fill insulation fall through the opening. The full level of ceiling insulation shall be maintained to the edge of the attic access opening by one of the following methods: I. The opening may be framed with wood or plywood boards. The framing shall be permanently attached and extend at least 4 inches above the final level of insulation. Cardboard or foam board are acceptable for attic access damming. II. A minimum 14-1/2-inch wide insulation batt laid flat, with an R-value equal to that specified for the attic, may be placed tightly around the perimeter of the access opening. This 14-1/2 inches shall be maintained in all outward directions from the access opening, including corners. Scoop out all loose-fill insulation from the edges before laying batts. 4. Pull-Down Stairs Pull-down stairs in heated areas shall be weather-stripped and insulated to a minimum of R-10. Insulation and weather-stripping shall be installed to allow easy operation of the stairs. Factory or sitebuilt pull-down stair covers shall have a minimum R-10. New pull-down stair assemblies with a minimum R-5 insulation rating will be permitted provided the insulation is between conditioned space and the attic stair assembly and gaskets or weather-stripping prevent air infiltration. 5. Crawl Space Access Doors Weather-stripping shall be permanently attached to create an effective air seal between the crawl space access frame and the door. Access door to be insulated with R-5 or greater rigid insulation securely attached to bottom side of door panel 6. Exterior Attic Access Doors Any outside access shall have a door that is constructed for continuous exposure to exterior conditions. Whole House Air Sealing Specifications rev 12/01/11 Page 5 of 14

IV Air Sealing & Testing Whole House Air Sealing includes a pre and post blower door test, and a measurement of building tightness. 1. Air Sealing Requirements a) All accessible and applicable items on AIR SEALING CHECKLIST shall be sealed. b) Whole house air sealing requires compliance with Section V Mechanical Ventilation. c) Air leakage testing, in accordance with Section 4, shall occur immediately prior to the installation of any air leakage control measures. Post-installation testing shall occur immediately following the installation of air leakage control measures. d) Pre and post blower door tests will be done by a BPI certified building analyst approved by program, or by a Questar Gas Company energy auditor. e) All air sealing work to be performed by contractor approved by program. f) Combustion Appliance Zone testing shall be performed in accordance with Section 4. g) All locations except the following are considered to be accessible: I. Locations physically accessible due to building structure or mechanically fastened materials II. Top plates located adjacent to eave line III. Top plates covered by more than ten inches of loose-fill insulation or a combination of loosefill and batt/blanket insulation totaling R-30 or more. Whole House Air Sealing Specifications rev 12/01/11 Page 6 of 14

All accessible and applicable items on AIR SEALING CHECKLIST shall be addressed. AIR SEALING CHECKLIST Attic Item Attic hatch/door Pull down stair cover Duct penetrations Chases Recessed cans Bath fans Bath fans with heat source Electrical penetrations Plumbing penetrations Top plates Drop soffits Kneewall doors Sealing requirements between conditioned and unconditioned space/exterior Weather-stripping permanently attached to create an effective air seal between the attic access frame and hatch/door Gasket or weather-stripping permanently attached between frame and door or air-tight cover installed between stairs and attic Foam/caulk or other air-tight seal around perimeter of duct boots between the boot and the subfloor Foam/caulk/rigid material sealed to attic floor/wall; use fire rated materials at chimneys and flues Foam/caulk or other air-tight seal between fixture and ceiling or install air-tight drywall, sheet metal, or other non-combustible assembly; maintain 3" space between non-ic rated fixtures and insulation ; Do insulate above non-ic rated fixtures Foam/caulk or other air-tight seal around fixture perimeter Fire rated materials shall be used. Foam /caulk/ rigid sheet if opening larger than 1 inch Foam/caulk or other air-tight seal around perimeter of electrical junction box Penetrations sealed Accessible drywall to top plate connections, wood to wood seams, other wall penetrations sealed with foam/caulk Rigid material covering attic floor opening and sealed with foam/caulk Weather-stripping permanently attached to create an effective air seal between the attic access frame and hatch/door. Install latch or handle if necessary Whole House Air Sealing Specifications rev 12/01/11 Page 7 of 14

Kneewall transition (under floor paths) Kneewall bottom plates Open wall cavities Rigid material between joists; Foam/caulk perimeter of each rim joist Floor/floor plate connection sealed with foam/caulk Rigid material sealed to attic floor/wall Crawl Space/Unconditioned Basement Item Crawlspace hatch/door Chases Duct penetrations Plumbing penetration Electrical penetrations Other open cavities Sealing requirements between conditioned and unconditioned space/exterior Weather-stripping permanently attached to create an effective air seal between the crawl space access frame and hatch/door Foam/caulk/rigid moisture resistant material sealed to ceiling/wall; use fire rated materials at chimneys and flues Foam/caulk or other air-tight seal around perimeter of duct boots between the boot and the subfloor Penetrations sealed; Rigid moisture resistant material sealed to crawl space/basement ceiling if opening larger than 1 inch Foam, caulking; Rigid material sealed to crawl space/basement ceiling if opening larger than 1 inch Rigid material sealed to ceiling Conditioned Basement Item Sealing requirements between conditioned and unconditioned space/exterior Sill plate/stem wall Sill plate to stem wall connection sealed with foam/caulk Rim joists Rigid material between joists; Foam/caulk perimeter of each rim joist Whole House Air Sealing Specifications rev 12/01/11 Page 8 of 14

Walls Separating Conditioned Space From Exterior/Unconditioned Space Item Plumbing penetrations Doors Other unintentional opening Electrical boxes (optional) Baseboards (optional) Door & window trim (optional) Window weather-stripping (optional) Sealing requirements between conditioned and unconditioned space/exterior Foam /caulk/rigid moisture resistant material if opening larger than 1 inch Weather-stripping and door sweep/air-tight threshold permanently attached to create an effective air seal between interior and exterior/unconditioned space Sealed with appropriate material if accessible Seal box to drywall 2. Sealing Floor Penetrations Air sealing shall prohibit drainage or maintenance of plumbing system. 3. Air Leakage Testing Protocol a) All windows and doors shall be properly closed, including pass-through wood-box doors and pet doors. All interior doors shall be left open. b) Ventilation openings: All exhaust fan openings, vent openings, and intake-air vents with backdraft dampers (e.g., dryer vents and kitchen, bathroom, utility room, whole-house, range vents, etc.) shall NOT be sealed. c) Exterior vent openings without backdraft dampers (e.g., some continuous ventilation systems) shall be temporarily sealed for the test. Heat recovery ventilator supply openings shall be sealed. Heat recovery ventilator exhaust openings should have backdraft dampers and shall be sealed. d) When measuring house leakage to determine overall leakage and Mechanical Ventilation, supply and return registers shall be open. e) Combustion appliances: All flue dampers, fireplace doors, and wood burning stove doors shall be closed, but NOT sealed. In conditions of gas logs in solid-fuel-burning fireplaces, the permanently blocked open dampers shall NOT be closed nor sealed. f) Equipment Set-up: The blower door and digital manometer equipment shall be set-up using the manufacturer instructions for depressurization to 50 Pa. g) Quantifying Air Leakage Reduction: Air leakage reduction is determined by the difference between pre-and post-measure cfmcfm50. The post-measure cfmcfm50 is also used to determine if mechanical ventilation is required. See section V. Whole House Air Sealing Specifications rev 12/01/11 Page 9 of 14

4. Combustion Appliance Safety Testing a) In homes with one or more combustion appliances for the purpose of space heating or water heating, combustion safety testing shall be performed both before and after air sealing. b) A combustion appliance is any appliance that burns fuel, such as natural gas, propane, oil, or wood. This includes furnaces, boilers, water heaters, wood stoves, and fireplaces (in case of wood stoves and fireplaces normally used for space heating, safety tests may be limited to worstcase CAZ depressurization test, with depressurization limit of -5 Pa). c) The following tests are required at minimum, with test procedures and action levels as specified in Building Performance Institute Technical Standards for the Building Analyst Professional (BPI Standards): Carbon monoxide test of undiluted flue gas. Ambient carbon monoxide test of CAZ. Spillage test. Draft test. Worst-case CAZ depressurization test. Gas supply line leak test. Note: The BPI Standards sections Health and Safety and Combustion Safety and Carbon Monoxide Protection are included within these specifications by reference. Whole House Air Sealing Specifications rev 12/01/11 Page 10 of 14

V Mechanical Ventilation 1. General Mechanical Ventilation Requirements All homes that have whole house air sealing performed shall receive: Care for Your Air: A Guide to Indoor Air Quality, EPA Indoor Air Quality Homeowner Disclosure Form Whole House Mechanical Ventilation Compliance is required for homes where Whole House Air Sealing is performed. 2. Spot Ventilation Bath & Kitchen Fans a) All exhaust fans shall be vented to the exterior of the structure, with ducts mechanically fastened and air-sealed to the termination or the vent. b) Any newly installed exhaust fan ducts must be sized according to Exhaust Fan Prescriptive Duct Sizing requirements and installed in meeting following requirements: a. Exhaust ducts in unconditioned space shall be insulated to a minimum of R-4. b. Exhaust fan ducts shall sag, and shall be as straight as possible to maximize effective air flow, and have no more than two 90-degree turns, or equivalent. c. Exhaust ducts shall be securely attached at each joint and to the fan housing using mechanical fasteners, such as sheet metal screws or a securely tightened metal clamp. Fasteners shall interfere with damper operation. d. Exhaust duct shall be sheet metal or HVAC flex-duct and insulated to a minimum of R-4. Vinyl coil duct is. c) Existing vent ducts may remain if they are free of holes and kinks and are in otherwise good condition, provided they are vented to the exterior, free of gaps, and sealed to prevent exhaust air from entering back into the attic. Kitchen Fans a) Non-recirculation kitchen range exhaust fans ducts shall be vented to the exterior of the structure, with ducts mechanically fastened and air-sealed to approved metal termination. Venting kitchen fans to existing plastic ducts and plastic roof vents is b) Any newly installed kitchen exhaust fan ducts must be sized according to Exhaust Fan Prescriptive Duct Sizing requirements. c) Kitchen range exhaust fans vented through the ceiling shall be connected to a duct made of 28- gauge galvanized steel, stainless steel, aluminum, or copper (IMC 505.1) which is substantially airtight throughout and which terminates directly to the outside through an approved metal termination. Backdraft dampers are recommended. Existing installations that substantially meet these requirements are acceptable. Downdraft Exhaust Fans Downdraft exhaust ducts may have one 90-degree turn, shall exit through the foundation or exterior wall, be sealed (with no visible gaps) to a vent cap designed for kitchen exhaust. Unless otherwise Whole House Air Sealing Specifications rev 12/01/11 Page 11 of 14

by local code, downdraft exhaust ducts shall comply with material requirements for Kitchen Fans. Dryer Exhaust Dryer exhaust ducts shall be vented to the exterior of the structure, sealed to prevent exhaust air from entering the building, shall have a back-draft damper, and shall terminate in a code-approved vent cap. New dryer ducts shall be rigid metal and shall be securely connected with mechanical fasteners and permanently supported. Exhaust systems shall comply with local code and manufacturer specifications, be as straight as practical, sloped downward to allow condensate drain, and shall exceed 25 feet. To prevent blockage with lint, new dryer vent ducts shall be connected with screws. A metal clamp or UL-rated foil tape may be used to secure dryer duct connections. Exhaust System Makeup Air Exhaust systems capable of exhausting in excess of 450 CFM shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Exceptions: When there are no atmospherically vented or solid-fuel burning combustion appliances within pressure boundary of house, or for whole-house ventilation fans designed for summer house cooling with windows opened. Whole House Air Sealing Specifications rev 12/01/11 Page 12 of 14

Exhaust Fan Prescriptive Duct Sizing Use table below to size new exhaust fan ducts correctly. Duct Type Fan Rating in CFM Duct Diameter 3 HVAC Flex Duct Smooth Hard Duct 50 80 100 125 50 80 100 125 4 70 3 Maximum Duct Length in Feet 5 105 35 5 5 unlimited 70 35 20 unlimited 135 85 55 6 unlimited unlimited 125 95 unlimited unlimited unlimited 145 7 unlimited unlimited unlimited unlimited unlimited unlimited unlimited unlimited Table assumes no elbows. Deduct 15 ft of allowable duct length for each elbow. Table adapted from ASHRAE Standard 62.2 (2010), page 6, Table 5.3. 3. Whole-House Mechanical Ventilation a) As part of air sealing as a program measure, whole-house mechanical ventilation systems shall exist or be installed and shall provide airflow rates as calculated by the Whole House Ventilation Calculator. b) Ventilation provided by the whole-house mechanical ventilation system shall provide air flow calculated by the Whole House Ventilation Calculator. Air flow rates shall be tested by the contractor and based on the rated air flow rate of the fan. c) The whole-house mechanical ventilation system shall run automatically either continuously or intermittently on a timer. d) Whole house mechanical ventilation is required if Whole House Ventilation Calculator shows required whole-house fan measured flow rate of zero cfm. e) Note: These mechanical ventilation procedures are to be used in lieu of procedures contained in the section Building Airflow of the \BPI Standards. Exhaust Fans Exhaust fans installed for whole house mechanical ventilation purposes shall be ENERGY STAR compliant, have a sone level of 1 or less, and be rated for continuous operation. Heat Recovery Ventilation Energy or Heat Recovery Ventilators installed for whole-house mechanical ventilation purposes shall be certified and listed in the Home Ventilating Institute directory, shall be ENERGY STAR compliant and Whole House Air Sealing Specifications rev 12/01/11 Page 13 of 14

rated for continuous operation. Any ducts installed as part of a Heat Recovery Ventilation system shall be sealed and insulated as required by code for heating/cooling ducts. Bathroom Fans as Whole-House Fans Bathroom exhaust fans may be used to provide whole house ventilation as well as bathroom spot ventilation provided all of the following conditions are met: a) A minimum 1 clearance under the bathroom door to provide for a clear air pathway to the rest of the house when the bathroom door is closed. Or an alternative equivalent means of providing a clear air pathway is installed. b) The fan shall have both automatic and manual controls. c) The fan is set to run automatically either continuously or intermittently on a timer. d) There is a manual control switch for spot-ventilation purposes. e) All conditions of Spot Ventilation requirements must be met. Fresh Air Inlets Air inlets that are part of the ventilation system shall be located a minimum of 10 feet from known sources of contamination such as stack, vent, exhaust hood, or vehicle exhaust. The intake shall be placed so that entering air is obstructed by snow, plantings, or other material. Inlets shall have rodent/insect screens with mesh larger than ½ inch. Whole House Air Sealing Specifications rev 12/01/11 Page 14 of 14