Recent Developments in Quantitative Passive Soil Gas Sampling for VOCs

Similar documents
Brownfields: The Next Generation 7 th Annual Canadian Brownfields Network Conference Toronto, ON. 15 June Todd McAlary

Passive Sampling Demonstration/Validation for Vapor Intrusion Assessments

Quantitative Passive Diffusive Sampling for Assessing Soil Vapor Intrusion to Indoor Air

Passive Sampling for Vapor Intrusion Assessment

Passive Soil Gas Monitoring for Long-Term Stewardship of Vapor Intrusion Risk

PASSIVE SAMPLING FOR VAPOR INTRUSION ASSESSMENT

Quantitative Passive Diffusion-Adsorptive Sampling Techniques for Vapor Intrusion Assessment

VI Investigations in North Carolina What We ve Learned. Delonda Alexander NC Dry-Cleaning Solvent Cleanup Act Program

A Review for the US Navy of Best Practices, Knowledge and Data Gaps, and Research Directions for Vapor Intrusion

ESTCP Research on Optimization of Vapor Intrusion Mitigation Systems in Large Military Buildings

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas

REPORT DOCUMENTATION PAGE

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Beyond Canisters (SUMMAs): Passive and Active Samplers and International Perspective

Ask The Expert Webinar Series Vapor Intrusion Assessments Part Two: Improving Data Quality Using Today s Best Practices for Sample Analysis

Mass Flux Characterization for Vapor Intrusion Assessment

Ensuring Data Integrity

RAPID ASSESSMENT OF A LARGE INDUSTRIAL MANUFACTURING SITE USING WMS-LU PASSIVE SOIL VAPOUR SAMPLERS

Post-Remedy Vapor Intrusion Evaluation for the Laboratory for Energy-Related Health Research (LEHR) Superfund Site

Implementation of a Strategic Approach for Complex Vapor Intrusion Assessment at a Large Military Facility

Building Pressure Cycling for Vapor Intrusion Assessment

Examples of Data Collection Strategies and Methods

Pneumatic Testing, Mathematical. and Optimize the Performance and. Slab Depressurization Systems

Vapor Intrusion Assessment. Kaitlyn S. Rhonehouse, P.E. Florida Brownfield Association 16 th Annual Conference, Brownfields in Motion

Empirical Data: Challenges and Future Directions

Alternative Sampling Methods Implemented at North Carolina Dry-Cleaning Solvent Act (DSCA) Program Sites: A Compilation of Noteworthy Data

MPCA Site Assessment: Vapor Intrusion Investigation. Remediation Division Superfund Unit 1

Increasing Availability of Continuous and Real-Time VOC Monitoring Technologies for VI Assessment

Stylistic Modeling of Vadose Zone Transport Insight into Vapor Intrusion Processes

UNDERSTANDING THE ROLE OF SEWER PREFERENTIAL PATHWAYS IN VAPOR INTRUSION. Thomas McHugh, Ph.D., D.A.B.T. Lila Beckley, P.G.

Sustainability; in Residential, Commercial and Industrial Buildings

Todd McAlary, M.Sc., P.Eng., P.G. Geosyntec Consultants, Inc., Environmental Monitoring and Data Quality Workshop La Jolla, CA 28 March 2012

A New Passive Diffusion Sampler (PDS) for Soil Gas Sampling

Soil Vapor Installation

Vapor Intrusion: The Conference An Analytical Perspective

Risk Management Strategies to Address Vapor Intrusion Assessment and Mitigation Uncertainties Robert Ettinger Geosyntec Consultants

Intensive Study of VOCs and Radon in a Historical Duplex A First Look

Expediting VI Assessments & Remedies with High Res Data

Use of Building Pressure Cycling in Vapor Intrusion Assessment

Resolving Vapor Intrusion Challenges via Automated Continuous Real-Time Monitoring and Response

PRACTICAL ASPECTS OFCONDUCTING SOIL VAPOR INVESTIGATIONS in general accordance with the 2015 DTSC Advisory

Field Methods to Distinguish Between Vapor Intrusion and Indoor Sources of VOCs

Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.

ATTACHMENT 12: CDISCO Description and Sensitivity to Input Parameters

TRANSPORT PATHWAY EVIDENCE OF A SEWER VAPOR. Findings from Work Performed at the Indianapolis USEPA Research Duplex

Practical Aspects of VI Assessment for TCE. Acknowledgments and special thanks to:

Specialty Seminar on Technical Updates to USEPA & ITRC Vapor Intrusion Guidance Data from Vapor Intrusion Investigations

Vapor Intrusion Pathway Screening for Soil Excavation Remedies

CERAMIC DOSIMETERS FOR TIME-INTEGRATED CONTAMINANT MONITORING

SOIL-GAS MONITORING: FINAL CONFERENCE, May 16th 2013, Ghent, Belgium. Soil-gas sampling installations Soil-gas sampling techniques

Expediting Vapor Intrusion Assessments Using High Resolution Continuous Monitoring

Sampling Instructions for Active Sampling

Vapor intrusion state of the art

MISSOURI RISK-BASED CORRECTIVE ACTION (MRBCA) FOR PETROLEUM STORAGE TANKS SOIL GAS SAMPLING PROTOCOL

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

Eurofins Air Toxics, Inc., is the global expert in environmental air testing. With more than 25 years of air expertise, we have analyzed a wide range

PASSIVE GROUNDWATER SAMPLING METHODS. Applications and Experience

NJDEP Vapor Intrusion Guidance

Modular approach to VOC assessment

MEMORANDUM. Purpose and Scope of Validation Study. DATE: October 9, 2006

Vapor Intrusion Assessment A Comparative Analysis of Subsurface Vapor Sampling Methods

Soil Vapor Reproducibility: An Analytical and Sampling Perspective

Available Laboratory Methods for Soil Gas Analysis

TECHNICAL MEMORANDUM

Lessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion

An Integrated Model for Design of Soil Vapour Intrusion Mitigation Systems

INDOOR AIR INVESTIGATION

Cost-Effective, Accurate Environmental Investigations Using Passive Soil Gas Sampling

Part 5 Soil Gas Sampling Methods. Soil Gas Measurement. VI Requires Much Lower DLs

Storage Cap. EPA Method 325 Fenceline Monitoring. Arrow Points Up. Sampling Protocol. Screen Cap

Groundwater Models and Modeling Considerations

Use of Soil-Gas Data in Vapor Intrusion Decisions

APPENDIX K. Groundwater Monitoring Results

Vadose Zone Profiling to Better Understand Processes

Benzene, toluene and xylene measurements in the vicinity of petrol stations (Toulouse France)

Site-Specific Characterization of Soil Radon Potentials

The Future of Vapor Intrusion (VI)

Quantitative Decision Framework for Vapor Intrusion Evaluation in DoD Industrial Buildings - Based on an Empirical Database

Detailed discussion of the Petroleum Vapor Database is provided in Davis R.V., 2009, LUSTLine #61 and EPA Jan

Soil Gas Sampling for 1,4-Dioxane during Heated Soil Vapor Extraction

March 2010 Frequently Asked Questions

Consideration of Vapor Intrusion Pathway Modeling in the MassDEP Draft Vapor Intrusion Guidance

Steps in Conducting Structural Vapor Intrusion Potential Evaluations Under the Inactive Hazardous Sites Branch 13 February 2017

Project Summary Site-Specific Protocol for Measuring Soil Radon Potentials for Florida Houses

Innovative, Non-Intrusive Passive Soil Gas Collection Device Maps Large Carbon Tetrachloride Plume at the DOE Hanford Site, Washington

ASTM E96 VS. F1249 WHICH PROVIDES MORE ACCURATE TEST RESULTS?

WBEA Standard Operating Procedure

EFFECT OF GLASS TRANSITION TEMPERATURE ON VOLATILE EMISSIONS FROM POLYMER MATERIALS

Outdoor Temperature and Differential Temperature as Indicators for Timing of VI Sampling to Capture the RME

DAMPNESS MEASUREMENT IN CONCRETE FLOORS.

A Dirty Secret: Duplicate Variability in Summa Canister Samples for Vapor Intrusion Investigations

Navy VI Web Tool: A Systematic Approach for Assessing Strength of Evidence

The Added Value of Stable Isotopes in Environmental Forensic Investigations.

Understanding VI Screening Levels

Drying of Concrete TDS 183

Powder Rheology. Powder Flow Measurement with MCR Rheometers

New Opportunities in Water Sampling & Waste Treatment

Response to Anonymous Referee #2

Soil thermal conductivity selection guide Choose the right measuring system or sensor for your application

Transcription:

Recent Developments in Quantitative Passive Soil Gas Sampling for VOCs Hester Groenevelt, Todd McAlary, Robert Ettinger Geosyntec Consultants, Inc. Tadeusz Gorecki, Faten Salim, Marios Ionnadis University of Waterloo 28 th Annual AEHS International Conference On Soil, Water, Energy and Air San Diego, CA 21 March, 2018 1

Outline Introduction to passive sampling Four keys to quality retention, recovery, starvation, calibration Starvation modeling vapor diffusion into a borehole field results Calibration modeling uptake rate over time lab results Future Applications Summary 2 There are four keys to accurate and precise concentration data when using passive sorbent-based sampling. Two of them retention and recovery have been evaluated extensively for active sorbent-based sampling methods such as EPA Method TO-17. This presentation will focus on the other two starvation and calibration which are important for quantitative passive sampling. 2

Basic Principle of Passive Sampling CTWA = M (UR)(t) C TWA M UR t = time-weighted average concentration = mass adsorbed = uptake rate = sampling duration M and t are measured (very accurately) UR is calibrated experimentally 3 M is measured in the laboratory under controlled condition and is usually accurate and precise within very fine tolerances. t is measured in the field at the time of sampler deployment and retrieval. If the sample duration is long (days to months) and the uncertainty in the start and stop times is one minute or so, the uncertainty in t is negligible. Therefore, the uptake rate is the critical parameter for accurate and precise concentration measurements. This is usually calibrated using controlled laboratory experiments. It can also be field-calibrated using side-by-side samples of a different method, for example, one Summa canister sample for analysis by EPA Method TO-15 beside one passive sampler (both with the same sample duration), which is referred to as an inter-method duplicate and can be implemented at a frequency of one in every ten or 20 investigative samples. 3

Benefits of Passive Sampling Time-integrated sampling minimizes temporal variability No electricity, mechanical parts, connections minimizes sampling errors Cost effective vs. active sampling quick and simple protocols shipping Less obtrusive 4 Some of the benefits of passive sampling are shown in this slide. Overall, the quality of data is comparable to other methods such as whole air sampling with Summa canisters, but the sampling can be performed more easily and cheaply with passive samplers. For more information on the demonstration and validation of passive samplers, see ESTCP ER200830 final report (click link to final report on the right side of this page: https://www.serdp-estcp.org/program-areas/environmental- Restoration/Contaminated-Groundwater/Emerging-Issues/ER-200830/ER-200830) 4

Shipping and Handling 72 Summa canisters 72 passive samplers Key Point: passive samplers are much easier to work with 5 The expense and labor associated with shipping and handling a large number of Summa canisters can be alleviated using passive samplers. The sampling protocols are also easier and there are no risks of leaks in the sample train, so leak-checks are not required. 5

Passive Samplers Quantitative Radiello Semi-Quantitative Gore Module ATD Tubes SKC Ultra III 3M OVM 3500 Waterloo Membrane Sampler Beacon Key Points: different samplers have different sizes, uptake rates, sorbents, wind screen, and methods of analysis not all samplers have calibrated uptake rates 6 Passive samplers come in two categories: 1) Quantitative passive samplers which have calibrated uptake rates and are of fixed geometry 2) Semi-quantitative passive samplers which have uptake rates that vary due to their unfixed geometry 6

Four Keys to Quality 1) Retention sorbent must retain the VOCs of interest during sampling 2) Recovery sorbent must release the VOCs of interest during analysis 3) Starvation if the uptake rate of the sampler is higher than the delivery rate of analytes to the sampler, the sampler will scrub its environment, causing a negative bias in the measured concentration 4) Calibration factors that can affect the uptake rate must be understood (Retention and recovery have been extensively studied for active sorptive sampling like Method TO-17) 7 As mentioned earlier, this presentation will focus on starvation and calibration. Starvation is a phenomenon that is well-known in passive soil gas sampling, and calibration must be well-understood in order to get quantitative passive sampling results. 7

Starvation mass flux into passive sampler mass flux through void space mass flux through soil to void space Diffusion is usually the main transport mechanism for vapors in soil. Diffusion coefficients depend on soil moisture content. 8 This slide show a graphical representation of a cylindrical borehole in the vadose zone containing a passive sampler. The mass flux through the soil to the void space (the red arrows) occurs at a rate that depends on the soil texture and moisture. The mass flux through the void space will never be slower, because the tortuosity of the soil restricts the diffusion rate. If the uptake rate of the sampler is the rate-limiting step, the concentration in the void space will equilibrate with the surrounding soil. However, if the uptake rate of the sampler is high, it will become a scrubber that will cause the concentration in the void space to be lower than the surrounding soil, and cause a negative bias in the reported concentration (this is referred to as the starvation effect). 8

Modeling Diffusion to a Borehole 9 We developed two mathematical models (transient and steady-state) to simulate the rate of vapor diffusion from the soil to the void space as a function of the soil moisture content. 9

Model Results Transient Steady-State Steady-state is reached fairly quickly Uptake rates less than about 1 ml/min are preferred to minimize starvation (Lower is better in wet soils) 10 Results from transient modelling (left chart) show that steady-state is reached within minutes or hours for all but very wet soils, which may require up to a day to equilibrate. (Theta sub w is the water-filled porosity. The total porosity was fixed at 35% for these simulations). Results from steady state modeling (right chart) show the diffusive delivery rate (the rate at which analytes are transported from the soil to the cylindrical borehole, expressed in the same units as the uptake rate, ml/min) as a function of the waterfilled porosity of the soil. Delta is the concentration in the void space divided by the concentration in the surrounding soil (i.e., a delta of 0.95 corresponds to a negative bias of 5%, a delta of 0.75 corresponds to a negative bias of 25%, etc.). These simulations indicate that a passive sampler uptake rate less than about 10 ml/min is required for well-drained soils and a lower uptake rate (less than 1 ml/min) would be preferred in wetter soils. 10

Low-Uptake Rate Samplers Decrease sampling surface area Increase membrane thickness 11 Most commercially available passive samplers can be adapted to lower the uptake rate, either by decreasing the area of the sampling surface, or by increasing the membrane thickness of a permeation sampler. Lower uptake rates are advantageous in three scenarios: 1) To minimize or eliminate negative bias attributable to starvation, 2) To avoid overloading the sorbent in setting where there are very high vapor concentrations, and 3) To avoid overloading the sorbent when sampling over very long durations. 11

Field Methods 2 options: open holes for single use or sealed probes for periodic monitoring 12 This slide shows some photos of installations of passive samplers for soil gas and subslab sampling: 1) Use of a hammer drill and a 5-foot long, 1-inch diameter drill bit to install a temporary soil gas probes 2) Use of a hammer drill to install a sub-slab probe 3) A depiction of a open borehole (represented by the glass cylinder) with a passive sampler and a foam plug in a plastic sleeve to collect a depth-discrete soil gas sample 4) A depiction of a completed soil gas probe, fitted with a piece of steel strapping which creates a gap in the vadose zone in which to deploy the passive sampler (length to be adjusted as needed for sampling at any desired depth). 12

Results in Dry Soil 1000000 100000 Passive Sampler (µg/m³) 10000 1000 Sub-Slab Soil Gas Uptake rates in the range of 3 to 5 ml/min provide good correlation to active sampling in dry soil (sub-slab is usually dry because the building is an umbrella) 100 100 1000 10000 100000 1000000 Active Sampler (µg/m³) 13 In dry soils, there is a very good correlation between concentrations measured in a passive sampler (the y-axis) and measured by an active method (the x-axis) over a span of several orders of magnitude, as long as uptake rates are fairly low (less than 5 ml/min) so the passive samplers do not experience significant starvation. 13

Results for Wetter Soils Passive Sampler (µg/m 3 ) 100,000,000 10,000,000 1,000,000 100,000 10,000 Uptake rate about 1 ml/min Uptake rate about 0.1 ml/min 1,000 1,000 10,000 100,000 1,000,000 10,000,000 100,000,000 Active Sampler (µg/m 3 ) Key point: reducing the uptake rate from 1 to 0.1 ml/min reduced starvation Simple modification of 10X thicker membrane 14 In wetter soils, we see that the passive samplers begin to demonstrate a negative bias due to starvation. The blue data points show results for a passive sampler with an uptake rate of about 1 ml/min and all fall below the diagonal 1-to-1 line, indicating a negative bias. The orange diamond symbol shows results for a passive sampler with a 10-times thicker membrane and the correlation to active sample results (Summa canister/to-15) improves significantly. 14

Implications of Lower Uptake Rates Sample duration is related to target concentration Select the sample duration to provide a concentrations reporting limit equal to or less than the sub-slab or soil gas screening level (SL). But how might a long sample duration affect the uptake rate? 15 One consequence of reducing the uptake rate is that the sample duration must be extended proportionately in order achieve the same reporting limit. The reporting limit is the lowest concentration that can be quantified reliably and must be lower than the screening level that the sample is intended to satisfy. This raises the question of consistent the uptake rate is during a long sampling period. As an example: Consider a compound that has a subslab screening level (SSSL) of 100 µg/m3. If the laboratory can reliably detect as little as 0.05 µg of mass (M) for that compound, and the sampler uptake rate is 1 ml/min, the sample duration must be at least 12 hours. If the uptake rate was reduced to 0.1 ml/min, the sample duration would have to be at least 5 days. 15

Transient Modeling of Uptake Rate Environmental Science: Processes & Impacts, 2017, 19, 1363-1373 Membrane 0 x L Sorbent bed L m m x L b Air Gap Sorbent Membrane VOC uptake L b L m x x= 0 Model considers: permeation of analytes though the membrane mass transfer between gas and sorbed phase in sorbent bed migration of analytes within the sorbent bed 16 A mathematical model was developed to characterize the uptake of analytes by a permeation passive sampler (the Waterloo Membrane Sampler, or WMS). 16

Model Results Uptake Rate vs Time 2.0 1.5 Uptake rate (ml/min) 1.0 0.5 Toluene/Carbopack B Co = 2.3 µg/m 3 0.0 0 2 4 6 8 10 12 14 16 Time (days) Key Point: reducing the uptake rate by increasing the membrane thickness minimizes the change in uptake rate over time. 17 The scenario that was modelled was that of a worst case where the uptake rate is expected to vary over time: a weak sorbent (Carbopack B) and an analyte with low affinity to it (toluene). The reason for this is that we wanted the model to show a change in the uptake rate so that the results could be dissected. If a stronger sorbent, such as Anasorb 747, is used, the change in uptake rate over time is expected to be much less. The model results show that for a 100 µm thick membrane (the orange dashed line), the uptake rate declines over time. By reducing the uptake rate 2-fold by increasing the membrane thickness to 200 µm (the blue dashed line), the change of the uptake rate over time is greatly reduced. 17

Model vs Experimental Results 2.5 2.0 Carbopack B (Non-porous particles) 2.5 Anasorb 747 (Porous particles) 100 µm membrane / toluene 100 µm membrane / toluene 2.0 Uptake 1.5 Rate (ml/min) 1.0 0.5 1.5 1.0 0.5 0.0 0 10 20 30 0.0 40 Time (day) 0 10 20 30 40 Time (days) Key Point: model matches experimental data which provides confidence in ability to predict the uptake rate for any sample duration 18 Experimental results show good agreement with the model results. And, as described on the previous slide, the stronger sorbent, Anasorb 747, shows a much smaller change in uptake rate over time, even with the 100 µm membrane. 18

Model Results - Toluene Distribution Moles of Toluene 1.E-03 1.E-04 1.E-05 1.E-06 1.E-07 1.E-08 1.E-09 1.E-10 1.E-11 1.E-12 Sorbed on the sorbent In the air in the packaging In the membrane In the air spaces between the sorbent particles >99% 1.E-13 0 1 2 3 4 5 6 7 8 Storage time (day) <1% <0.1% <0.001% packaging sorbent bed with air spaces membrane Key Point: the vast majority of the analyte is trapped by the sorbent, as intended 19 19 The model results also show the distribution of analytes in the different compartments of a permeation passive sampler. This allows us to see that the great majority of the analyte, >99%, is trapped by the sorbent, as intended. Only a very small amount (<0.1% for toluene) remains in the membrane. 19

3-Month Sample Durations 20 Experimental validation of the uptake rate vs time model was performed using this experimental set-up, in which samplers were exposed to a known concentration of >50 different VOCs over a 3-month period. 20

Measured versus Modeled Uptake Rates For most VOCs in the 8260 analyte list, the measured uptake rate was within 2x of the expected uptake rate 21 Results show that the experimental uptake rate over 3 months is mostly within a factor of 2 of the uptake rate measured for a 7-day sample duration, with only a few outliers. 21

Potential Applications Round-the-calendar monitoring 4 successive 3-month samples never miss a day What about short-term exposures? if a 10-day sample concentration is <0.1 µg/m 3, no single 24- hour period could have been above 1 µg/m 3 same for a 100-day sample concentration of <0.01 µg/m 3 Key Point: where there really is no vapor intrusion, this is a cost-effective way to document it 22 There are several potential applications for long-term indoor air monitoring. 22

Take-Home Messages Quantitative Passive Sampling for Soil Gas has arrived key is to have an uptake rate lower than the diffusive delivery rate this innovation was awarded a US patent (#9399912) in 2016 WMS sampler uptake rates are easily adjusted via membrane thickness Lower uptake rates require longer sample durations e.g., 1 week with UR = 0.1 ml/min for SGSL of 60 µg/m 3 Longer sampling durations can be a good thing talk to anyone in the radon field (90-days is a short-term sample) uptake rates for various sample durations can now be calculated field calibration may be challenging for durations >14 days creates new options for cost-effective monitoring 23 Quantitative passive soil vapor sampling is accurate and precise when the uptake rate of the sampler is lower than the diffusive delivery rate of VOC vapors through soil to the void space in which the passive sampler is deployed, as supported by mathematical modeling and a comprehensive demonstration/validation (ESTCP ER200830). A lower uptake rate requires a proportionally longer sample duration to achieve the same reporting limit. Another mathematical model validated with experimental data shows that uptake rates can decrease over long times, particularly for weak sorbents with weakly sorbed analytes; however, experimental results show that for strong sorbents, the uptake rate does not decrease significantly over a 3-month period. Longer sampling times have certain advantages, such as the ability to collect long-term time-weighted average samples easily and cheaply. Field calibration with inter-method duplicates is valuable when the highest level of accuracy is desired. This has been difficult when collecting samples over 14 days or longer, but Alan Rossner of Clarkson University is evaluating 14 day flow controllers for Summa canisters as part of an ESTCP project, and this will make it a lot easier to fieldcalibrate long-term passive samplers. 23

Peer-Reviewed Articles McAlary, T., X. Wang, A. Unger, H. Groenevelt and T. Górecki, 2014. Quantitative passive soil vapor sampling for VOCs- part 1: theory. Environ. Sci.: Processes Impacts, 2014, DOI: 10.1039/C3EM00652B. McAlary, T., H. Groenevelt, S. Seethapathy, P. Sacco, D. Crump, M. Tuday, B. Schumacher, H. Hayes, P. Johnson and T. Górecki, 2014. Soil vapor sampling for VOCs using passive diffusive samplers laboratory experiments. Environ. Sci.: Processes Impacts, 10.1039/c3em00128h. McAlary, T., H. Groenevelt, P. Nicholson, S. Seethapathy, P. Sacco, D. Crump, M. Tuday, H. Hayes, B. Schumacher, P. Johnson, T. Górecki and I. Rivers-Duarte, 2014. Quantitative passive soil vapor sampling for VOCs: field experiments. Environ. Sci.: Processes Impacts, 10.1039/c3em00653k. McAlary, T., H. Groenevelt, S. Seethapathy, P. Sacco, D. Crump, M. Tuday, B. Schumacher, H. Hayes, P. Johnson, L. Parker and T. Górecki. Quantitative passive soil vapor sampling for VOCs: flow-through cells. Environ. Sci.: Processes Impacts, 10.1039/c4em00098f. McAlary, T., H. Groenevelt, S. Disher, J. Arnold, S. Seethapathy, P. Sacco, D. Crump, B. Schumacher, H. Hayes, P. Johnson, T. Górecki. Passive Sampling for Volatile Organic Compounds in indoor Air Controlled Laboratory Comparison of Four Sampler Types. Environ. Sci.: Processes Impacts, 10.1039/c4em00560k. Salim, F., M. Ioannidis, T. Górecki. Experimentally validated mathematical model of analyte uptake by permeation passive samplers. Environ. Sci.: Processes Impacts, 10.1039/c7em00315c. Seethapathy, S. and T. Górecki, 2011a. Polydimethylsiloxane-based permeation passive air sampler. Part I: Calibration constants and their relation to retention indices of the analytes. J Chromatogr A. 2011 Jan 7; 1218(1):143-55. Seethapathy, S. and T. Górecki, 2011b. Polydimethylsiloxane-based permeation passive air sampler. Part II: Effect of temperature and humidity on the calibration constants. J Chromatogr A. 2010 Dec 10; 1217(50):7907-13. 24 24

Questions? 25