Numerical analysis of eccentric orifice plate using ANSYS Fluent software

Similar documents
Effect of Orifice Plate Shape on Performance Characteristics

Design, Fabrication & CFD Analysis of Multi-Hole Orifice Plate

Comparative Analysis of Different Orifice Geometries for Pressure Drop

NUMERICAL ANALYSIS OF FLOW THROUGH MULTISTAGE ORIFICE PLATE ASSEMBLIES WITH ALTERNATE CONCENTRIC AND ANNULAR ORIFICE PLATES

Effects of shaft supporting structure on performance test of axial flow fan

Flow and heat distribution analysis of different transformer sub-stations

ISO INTERNATIONAL STANDARD

SOP-10. Orifice Plate. Model. Description. Specifications. PLATE THICKNESS 3, 6, 9, 12mm

Investigation on the quality of bio-oil produced through fast pyrolysis of biomass-polymer waste mixture

Effect of plenum chamber depth in a swirling fluidized bed

The CFD Simulation of Cyclone Separator without and with the Counter-cone in the Gasification Process

CFD ANALYSIS OF CONVECTIVE FLOW IN A SOLAR DOMESTIC HOT WATER STORAGE TANK

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

ADVANCES in NATURAL and APPLIED SCIENCES

Heat transfer enhancement in fire tube boiler using hellically ribbed tubes

CFD Modelling of an Aerosol Exposure Chamber for Medical Studies G. Manenti, M. Derudi, G. Nano, R. Rota

Numerical Investigation of the Flow Dynamics of a Supersonic Fluid Ejector

Numerical Modeling of Buoyancy-driven Natural Ventilation in a Simple Three Storey Atrium Building

Numerical and Experimental Modeling of Producer Gas Carburettor

Orifice Plates. All types of Orifice Plates and. relative products

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

Heat transfer modelling of slot jet impinging on an inclined plate

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Effects of Geometrical Parameters on Performance Characteristics of Venturimeter

NEW APPROACH TO CALCULATIONS OF TURBINE STAGES AND REGENERATION EXTRACTION POINTS MARIUSZ SZYMANIAK

Verification and Validation of Preliminarily Result of CFD of Electrostatic Precipitator Mr.Dharmendra Dekate 1 Mr.K.M.Narkar 2

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

Analysis of the Kaplan turbine draft tube effect

Investigating Two Configurations of a Heat Exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System

CFD Analysis of a Mixture Flow in a Producer Gas Carburetor for optimizing the design configuration

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

Project Background (long term goals)

COMSOL Multiphysics Simulation of Flow in a Radial Flow Fixed Bed Reactor (RFBR)

FLUID STRUCTURE INTERACTION MODELLING OF WIND TURBINE BLADES BASED ON COMPUTATIONAL FLUID DYNAMICS AND FINITE ELEMENT METHOD

Investigating two configurations of a heat exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System (IHICSSWHS)

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

CFD SIMULATION AND EXPERIMENTAL VALIDATION OF FLUID FLOW IN LIQUID DISTRIBUTORS

Research on the cavitation characteristic of Kaplan turbine under sediment flow condition

CFD ANALYSIS OF DROGUE ASSEMBLY FOR UNDERWATER APPLICATION

Computational Analyses of Combustive Vortex Flows in Liquid Rocket Engines

Flow Meter Calibration

An Effect of Fractal Flow Conditioner Thickness on Turbulent Swirling Flow

CFD Simulation Studies on Integrated Approach of Solar Chimney and Earth Air Tunnel Heat Exchanger for Building Space Conditioning

CFD Analysis of Pelton Runner

Numerical Analysis of Heat Pipe Fin Stack by Delta Wing Vortex Generator

NUMERICAL SIMULATION OF AIR NATURAL CIRCULATION AND THERMAL RADIATION IN PASSIVE CONTAINMENT COOLING SYSTEM

Hydraulic performance of a low specific speed centrifugal pump with Spanwise-Slotted Blades

heat exchanger modelling for generator ventilation systems

Evaluating the Flow Inside of Portable Wind Tunnels for Odour Measurements

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

NUMERICAL STUDY ON FILM COOLING AND CONVECTIVE HEAT TRANSFER CHARACTERISTICS IN THE CUTBACK REGION OF TURBINE BLADE TRAILING EDGE

CFD modeling of Plasmatron Methane Reformer

Modelling of Material Removal in Abrasive Flow Machining Process Using CFD Simulation

ISSN (ONLINE): , ISSN (PRINT):

Task 1 For Task 1, the outlet was set as a zero-gauge pressure outlet, which is the same outlet condition as the five smaller pipes.

VALIDATION OF A CFD MODEL IN RECTANGULAR SETTLING TANKS

A COMPARATIVE STUDY OF HEAT EXCHANGER EFFECTIVENESS FOR DOUBLE HELICAL AND STRAIGHT CIRCULAR GEOMETRY

MEASUREMENT OF AIRFLOW

CFD Investigation on Long-Haul Passenger Bus

INVESTIGATIONS ON PERFORMANCE OF A SAVONIUS HYDROKINETIC TURBINE

Study of water falling film over horizontal drop shaped and inverted drop shaped tubes

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY. May ALDEN RESEARCH LABORATORY, INC. 30 Shrewsbury Street Holden, MA 01520

CRHT VII. Design and CFD analysis of Pico- hydro Turgo turbine. Paper no. CRHT17-11

INVESTIGATION OF FLOW CHARACTERISTICS OF HELLER-TYPE COOLING TOWERS WITH DIFFERENT COOLING DELTA ANGLES

Vipac Engineers & Scientists Ltd

Numerical Investigation of Swirl's Effects in the Outer Annulus of a Reverse-flow Gas Turbine Combustor

Multilevel Diffuser Augmented for Horizontal Axis Wind Turbine

Impellers of low specific speed centrifugal pump based on the draughting technology

Available online at

CFD MODELLING OF AERODYNAMICS IN A SOLAR ENHANCED VORTEX GASIFIER (SVG): PART II. A PRELIMINARY STUDY OF THE LOCATIONS OF SEAL GAS INLETS

EFFECT OF PLENUM CHAMBER DEPTH IN A SWIRLING FLUIDIZED BED

Universities of Leeds, Sheffield and York

Doc No.:FAD17 (2224)C Draft INDIAN STANDARD IRRIGATION EQUIPMENT RAIN GUN SPRINKLER Specification PART 2 TEST METHOD FOR UNIFORMITY OF DISTRIBUTION

Investigation on Core Downward Flow by a Passive Residual Heat Removal System of Research Reactor

HYDRAULIC DEMONSTRATION CHANNEL

CFD simulation on the turbulent mixing flow performance of the liquid-liquid ejector

CFD Analysis for Production of Carbon Nanotubes

DESIGN AND ANALYSIS OF GAS TURBINE INTERNAL COOLING PASSAGE P.Sethunathan, S.Prathap, M. Prabakaran, S. Pawanraj, R. Siddharth

International Journal of Scientific and Research Publications, Volume 8, Issue 8, August ISSN

Comparison of RANS, URANS and LES in the Prediction of Airflow and Pollutant Dispersion

Rosemount 405 Compact Orifice Primary Element

Numerical modelling of shielding gas flow and heat transfer in laser welding process

A Numerical Investigation on bubble formation in Coolant channel with various Ethylene Glycol and water compositions and change in contact angle

An Investigation of Oxide Layer Impact on Heat Transfer in a Fuel Element of the MARIA Reactor

Pitot Tubes and Industrial DP Transmitters (Optional Exercise)

Quenching steels with gas jet arrays

NUMERICAL ANALYSIS OF HEAT PIPE HEAT EXCHANGER BY DELTA WING VORTEX GENERATOR

Literature Review on CFD Study of Producer Gas Carburetor

Derivation of Global Parametric Performance of Mixed Flow Hydraulic Turbine Using CFD. Ruchi Khare, Vishnu Prasad and Sushil Kumar

Impact of Pitot tube calibration on the uncertainty of water flow rate measurement

Computational Fluid Dynamics (CFD) Simulations of Dispersed Flow of Viscous Oil in Water in a Horizontal Pipe

Numerical thermal analysis of helical-shaped heat exchanger to improve thermal stratification inside solar storage tank

CFD analysis of high speed Francis hydraulic turbines

Simulation of Melting Process of a Phase Change Material (PCM) using ANSYS (Fluent)

Effect of geometrical parameters on heat transfer and pressure drop characteristics of plate fin and tube heat exchangers

EFFECT OF COMBINED HOLE CONFIGURATION ON FILM COOLING WITH AND WITHOUT MIST INJECTION

Troubleshooting Piping Systems

CFD Simulation Studies for Vertical Temperature Profile, Pitch Optimisation and Parametric Study of Borehole Heat Exchanger

CFD Modeling of Crankcase Inertial Oil Separators. Arun P. Janakiraman Anna Balazy Saru Dawar

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Numerical analysis of eccentric orifice plate using ANSYS Fluent software To cite this article: D Zahariea 2016 IOP Conf. Ser.: Mater. Sci. Eng. 161 012041 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 22/08/2018 at 03:34

Numerical analysis of eccentric orifice plate using ANSYS Fluent software D Zahariea Department of Fluid Mechanics, Fluid Machinery and Fluid Power Systems, Technical University Gheorghe Asachi Ia i, România E-mail: dzahariea@yahoo.com Abstract. In this paper the eccentric orifice plate is qualitative analysed as compared with the classical concentric orifice plate from the point of view of sedimentation tendency of solid particles in the fluid whose flow rate is measured. For this purpose, the numerical streamlines pattern will be compared for both orifice plates. The numerical analysis has been performed using ANSYS Fluent software. The methodology of CFD analysis is presented: creating the 3D solid model, fluid domain extraction, meshing, boundary condition, turbulence model, solving algorithm, convergence criterion, results and validation. Analysing the numerical streamlines, for the concentric orifice plate can be clearly observed two circumferential regions of separated flows, upstream and downstream of the orifice plate. The bottom part of these regions are the place where the solid particles could sediment. On the other hand, for the eccentric orifice plate, the streamlines pattern suggest that no sedimentation will occur because at the bottom area of the pipe there are no separated flows. 1. Introduction One of the most important, common and long history of use methods for fluid flow measurement is the differential pressure device method (head-loss device method), for which the difference in pressure measured at two points, upstream and downstream sides of the measurement device, is proportional with the rate of fluid flow. The flow measurement device, which in this case, is a restriction device causing the obstruction to the fluid flow, will generate a pressure drop which will be measured with two pressure taps positioned upstream and downstream of the restriction device. The most common taps installed configurations are: flange pressure taps, corner pressure taps and vena contracta taps (D and D/2 pressure taps), [1]. There are many restriction devices such as nozzles, Venturi nozzles and Venturi tubes, but by far, the most commonly used restriction device for flow measurement in pipes is the orifice plate (orifice meter) which is designed usually as: squared-edged orifice plate, squared-edged with conical back-cut orifice plates, sharp-edged orifice plates, conical entrance orifice plates, quarter-circle entrance orifice plate, segmental orifice plate and eccentric orifice plates, [1]. In order to obtain the desired accuracy some requirements should be accomplished: the circularity of both the orifice and the pipe, the plate flatness, the roughness of the upstream plate surface, the sharpness of the orifice edge, the thickness of both the plate and the orifice, the pressure taps, the pipe roughness, the eccentricity (the distance between the pipe axis and the orifice axis). There are many results referring to orifice plates, from which, in this context, should be mentioned: the comparative numerical analysis of different orifice plates [2], the numerical analysis of orifice plate working under non-standard Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

conditions [3], as well as the comparative numerical analysis of single hole and multi hole orifice plates [4]. However, all this research is about the conventional concentric orifice plate. Despite the fact that for conventional orifice plates, the pipe and the orifice should be concentric, there are some exceptional circumstances for which the eccentricity should be an effective design option. The eccentric orifice plates are recommended for flow measurement of fluids with entrained gas, liquid or sediments for which the sedimentation of such inclusions can thus be avoided, [5]. The eccentricity of the orifice is defined by the difference between the pipe axis and the orifice axis, and for the particular case analyzed in this paper, can be express through the formula: (1) where is the pipe diameter, = is the diameter ratio, and is the orifice diameter. This paper discusses the numerical analysis of an eccentric orifice plate used for flow measurement of liquids using ANSYS Fluent software, as compared with the conventional concentric orifice meter. The eccentric orifice plate has the same orifice diameter as the concentric orifice plate. 2. Geometry Both orifice meters are characterized by the same diameter ratio = =0.5, where =50 mm is the orifice diameter and =100 mm is the pipe diameter, as well as by the same pipe Reynolds number =10 5. Considering the fluid as water with density =998.2 kg/m 3 and dynamic viscosity =0.001003 Pa s, the fluid average velocity at the pipe inlet will result as =1.0048 m/s and the mass flow rate will be =7.8775 kg/s. The eccentricity computed using the equation (1), is equal with 25 mm. The orifice plate is located into a horizontal pipe with total length of 35D, between two pipe sections, the upstream pipe section with length =15D and the downstream pipe section with =20D, figure 1. Figure 1. Geometry of the computational domain. Because of the longitudinal symmetry of the geometry, a longitudinal symmetry cutting plane has been used, thus only one half of the pipe geometry will be modeled. The 3D model has been created using CATIA. The 3D geometric model has been transferred in ANSYS using the STP file format. The solid domain geometry of the orifice meters is presented in figure 2 for the concentric orifice plate, and in figure 3 for the eccentric orifice plate. Figure 2. Concentric orifice plate-solid domain. Figure 3. Eccentric orifice plate-solid domain. 2

3. Mesh Using fluid flow domain extraction techniques, the fluid flow domain has been obtained. The fluid flow domains from the orifice plate zone are presented in figure 4 for the concentric orifice plate, and in figure 5 for the eccentric orifice plate. Figure 4. Concentric orifice plate-fluid domain. Figure 5. Eccentric orifice plate-fluid domain. The mesh obtained for the concentric orifice plate is presented in figure 6. a) symmetry plane detail b) concentric orifice plate detail c) section plane detail d) inlet section detail Figure 6. Concentric orifice plate - mesh. 3

The mesh obtained for the eccentric orifice plate is presented in figure 7. a) symmetry plane detail b) eccentric orifice plate detail c) section plane detail d) inlet section detail Figure 6. Eccentric orifice plate - mesh. Both the mesh for concentric orifice plate, as well for the eccentric orifice plate has been obtained using Mesh application from ANSYS Workbench. In order to proper resolve the boundary layer along the fluid domain walls, as well as around the orifice plate an inflation mesh property has been defined with 25 layers and the first layer thickness adjusted for the dimensionless wall distance 1. The mesh principal parameters are presented in table 1. Table 1. Mesh characteristics. Orifice plate Nodes Elements Skewness Concentric 2496422 6650615 0.896 Eccentric 2455446 6550947 0.916 4. CFD analysis The CFD analysis has been performed using Fluent software for solving the Reynolds-Averaged Navier- Stokes equations with the following main settings: SST turbulence model; steady pressure based solver with SIMPLE pressure-velocity coupling algorithm with second order upwind spatial discretization for momentum, turbulent kinetic energy and specific dissipation rate. The boundary conditions of the problem are: the velocity =1.0048 m/s on the inlet section; the atmospheric pressure on the outlet section; no-slip boundary condition at the flow domain walls, as well at the orifice plate walls; zero normal velocity and zero normal gradients of all variables at the symmetry plane; the effect of gravity has been considered. 4

The convergence criterion of the steady state solution obtained by the CFD analysis has been defined as a sum of three convergence check criteria: the residual error for continuity, for x-, y- and z-velocity, for turbulence kinetic energy and for specific rate of dissipation should be under 10-4 ; the pressure at the inlet section, as one of the relevant variable of the analysis, should reach a steady solution; the relative mass flow rate imbalance between the inlet and the outlet sections should be less than 1% of the smallest mass flow through the flow domain. The convergence has been obtained after 880 iterations for concentric orifice plate analysis, and after 1283 iterations for the eccentric orifice plate analysis. At the convergence point, the relative mass flow rate imbalance is 3.12e-04% for concentric orifice plate and 5.82e-04% for the eccentric orifice plate. The computations have been parallelized performed on 32 cores of a SUPERMICRO workstation with 4 Intel XEON E5-4640 2.4 GHz processors, 256 GB DDR4 RAM, 2 TB HDD and NVIDIA Quadro K4000 3 GB GDDR5 video card. 5. Results The streamlines, both 3D and 2D, are presented in figure 7 for the concentric orifice plate, and in figure 8 for the eccentric orifice plate. a) 3D b) 2D Figure 7. Concentric orifice plate - streamlines. a) 3D b) 2D Figure 8. Eccentric orifice plate - streamlines. 5

6. Validation The validation of the CFD analysis has been done by comparing the CFD results with the results provided by the standards ISO 5167, [1] and ISO TR 15377, [5] in terms of discharge coefficient. The discharge coefficient is defined as, [1]: (2) where =1 is the expansion factor. The validation results are presented in table 2. Table 2. Validation results. Orifice plate Pressure tappings Discharge coefficient, Relative Standard CFD error D and D/2 0.6062 0.6084 0.36% Concentric Flange, 25.4 mm 0.6062 0.6117 0.90% Corner, 3 mm 0.6069 0.6707 10.50% Eccentric Corner, 3 mm 0.6270 0.6887 9.83% 7. Conclusions The pressure drop across the orifice plate computed by CFD analysis is in very good agreement with the standard results, but starting from a certain distance from the orifice plate. In the close vicinity of the orifice plate, the errors are increased, and for this reason, further mesh improvement are required. However, the qualitative results obtained related with the streamlines pattern, confirm that the separated flow areas at the bottom part of the pipe, upstream and downstream of the concentric orifice plate where the solid particles could sediment, are not present for the eccentric orifice plate, and as consequence, for the eccentric orifice plate the sedimentation process will be avoided. Acknowledgments The author would like to acknowledge the computational resources offered by the Computer-Aided Fluid Engineering Laboratory from the Department of Fluid Mechanics, Fluid Machinery and Fluid Power Systems, Technical University Gheorghe Asachi Ia i, Romania. The Computer-Aided Fluid Engineering Laboratory has been equipped with hardware and software resources with the financial support of the grant ENERED, POSCCE-A2-O2.2.1-2009-4, ID 911. References [1] ISO 5167 2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full [2] Sridevi T, Sekhar D and Subrahmanyam V 2014 Comparison of Flow Analysis Through a Different Geometry of Flowmeters using Fluent Software Int. J. of Research in Eng. and Technol. 3(8) 141-149 [3] Karthik G S, Kumar K J Y and Seshadri V 2015 Prediction of Performance Characteristics of Orifice Plate Assembly for Non-Standard Conditions Using CFD, Int. J. of Eng. and Technical Research 3(5) 162-167 [4] Malatesch B, Ganesha T and Math M C 2014 CFD Analysis and Comparison of Fluid Flow Through a Single Hole and Multi Hole Orifice Plate, Int. J. of Research in Advent Technol. 2(8) 6-15 [5] ISO/TR 15377 2007 Measurement of fluid flow by means of pressure-differential devices Guidelines for specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167 6