National Property Inspections

Similar documents
National Property Inspections

National Property Inspections

SITE AND BUILDING INSPECTION CHECKLIST

All Pro Home Inspection. Home Report South Your Town

Inspection Report. Property Address:

Pre-Listing Home Inspection Checklist

HOME INSPECTION REPORT Prarie Circle

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Property Inspection Checklist

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434

Alabama Home Inspections

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

National Property Inspections

Building Inspection Report

National Property Inspections

1234 Main St. Buyer Name. Table of Contents

Total Home Inspection Checklist

New Home Warranty Handbook

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

SUMMARY 792 Youngfield Ct., Lakewood CO Frank Oz January 13, 2018

Home Inspection Report

component was performing its intended function; installation and condition were appropriate for age and use.

Stucco Moisture Inspection Report

PROPERTY PRESERVATION AND CAPITAL PLANNING

National Property Inspections

Inspect Hawaii. Property Inspection Report

Water Management & Damage Prevention: A Guide for Homeowners

Home Inspection Checklist

Property Inspection Report

The Inspector. Property Inspection Report

KEVIN BURNS BUILDING INSPECTIONS REGISTERED BUILDER PRE-PURCHASE VISUAL STRUCTURAL INSPECTION REPORT No. 822

FINEGAN INSPECTION SERVICES, INC.

Property Condition Assessment. Summary Report

MUSSELMAN HOME INSPECTION LLC

TOP 10 RED FLAGS #10 - SITE GRADING AND DRAINAGE PROBLEMS. Understand what issues your homebuyers are on the lookout for and how to offer solutions.

1234 Main St Denver CO 80210

REHABILITATION WORK WRITE-UP. Physical Address: Administrator: Grantee:

National Property Inspections

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Home Inspection Report

National Property Inspections

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

HOME MAINTENANCE GUIDE KEEPING YOUR HOME IN EXCELLENT CONDITION

HOME INSPECTION CHECKLIST

Calidad Home Inspection Colleyville, TX (817) /

FINEGAN INSPECTION SERVICES, INC. 76 WEST FOSTER MAINEVILLE ROAD MAINEVILLE, OHIO PHONE FAX

Capstone Inspection Services LLC

TML Home Inspectors, Inc.

UP AND UP HOME INSPECTIONS

RSH ENGINEERING, INC. END OF BUILDERS WARRANTY INSPECTION REPORT INSP#: K00001 DATE: 00/00/11 PAGE #: 1

Rental Inspection Checklist

JBR Property Inspections

Home Condition Checklist

J & M Solutions, LLC

Mills Elementary School Site Summary

InterNACHI Home Inspection Report Checklist

All Pro Home Inspection. Home Report North Your Town

My Home Was Built In What Can I Expect To See On My Report?

K.B. Polk Recreation Center Summary

County of Santa Barbara, California Facility Condition Assessment Total: $238,124. Appendix 1 Probable Cost Estimates Detail

Presenter: Mr. Rob Orwig, P.E. Senior Forensic Engineer/Heartland Regional Manager

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

National Property Inspections

Dr. Edward Livingston Trudeau Building. 118 Main Street, Saranac Lake, NY. Building Systems Report. June 24, 2018

Roof Systems ROOFS. Inspections

Assessing the Renovation Project

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Pinnacle Home Inspections, Inc. Serving Central Arkansas

dba National Property Inspections

Warranty At-A-Glance ONE YEAR WARRANTY PERFORMANCE STANDARDS

FirstEnergy Program Overview

Ottawa Inspections Inspection Report

about your house Before You Start Repairing or Replacing Roof Finishes Figure 1 Common problems

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

Harry Stone Recreation Center Summary

Walnut Creek Mutual Seventy

Hero Home Inspection Your Property Inspection Report. Sample Report

REPORT CHECKLIST SUPPLEMENT

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN

Property Condition Assessment

Madison's Home Inspections

National Property Inspections

Vallery Home Inspections, L.L.C.

bout your house before you start Repairing or Replacing Roof Finishes

SUMMARY 1234 Main St.Severn Buyer Name 02/20/2018 9:00AM

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

dba National Property Inspections

Tired of the Band-Aid or Short Term Solutions in our Industry. Our Industry Cuts Too Many Corners! To Save the Contractors Time and Money, not yours!

Friendly Inspection Services

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

3D Home Improvement and Inspection Services, Inc

The Home Doctor, Inc.

A Sample Report On The Conditions At:

CITY OF RICHMOND HEIGHTS DEPARTMENT OF BUILDING ZONING AND HOUSING STANDARDS AND REGULATIONS

Toronto Community Housing Executive Summary 2016/2017. BCA Report. Sample House High FCI

National Property Inspections

Transcription:

Monday, August 22, 2011 Inspector Joe Smith 548-254-3658 Page 1 of 33

GENERAL INFORMATION GENERAL CONDITIONS AT TIME OF INSPECTION : No Property Occupied : Property Faces : North South East þ West Year(s) Estimated Age Of Property : 16 Weather : Fair Temperature : 45 F Type of Property : þ Single Multi Primary Construction : Wood þ Block Brick Soil Conditions : þ Dry Persons Present : Buyer Damp/ Wet Buyer's Agent Snow Frozen Seller Seller's Agent DEFINITIONS : Below are listed the definitions used throughout the report to describe each feature of the property. ACC (ACCEPTABLE) The item/system was performing its intended function at the time of the inspection. MAR (MARGINAL) The item/system was marginally acceptable. (It performed its designed function at the time of the inspection. However, due to age and/or deterioration, it will likely require early repair or replacement.) NI (NOT INSPECTED) The item/system was not inspected due to safety concerns, inaccessibility and/or concealment or seasonal conditions. NP (NOT PRESENT) The item/system does not exist or was visually concealed at the time of the inspection. DEF (DEFECTIVE) The item/system failed to operate/perform its intended function, was structurally deficient, was unsafe or was hazardous at the time of the inspection. SCOPE OF THE INSPECTION : National Property Inspections wishes to remind you, every property requires a certain amount of ongoing maintenance, such as, unclogging drains, servicing of furnaces, air conditioners, water heaters, etc. This property will be no exception. It is suggested that you budget for regular maintenance/repairs. The following report is based on visual inspection only of the accessible areas of this property. Please read and study the entire report carefully. The intent of the property inspection is to identify and communicate conditions of the facility and components of the facility that are categorized and listed on the inspection form, particularly maintenance issues. The inspection is a visual review of readily accessible areas and components. The inspector will endeavor to observe the operation of mechanical and electrical systems and note the condition of the systems. It is not technically exhaustive and no excavation, disassembly or removal of covers, panels or obstructions is performed. Hidden or obstructed defects may not be observed. Page 2 of 33

GRADING / DRAINAGE Monitor Condition ACC MAR NI NP DEF þ Recommend Repairs þ þ Near Level Positive Slope Negative Slope Ponding Positive grading around most of the building with near level conditions. The concrete walks line the building on the west and north sides, asphalt on the rear(east) and the east side is dirt that has settled for the two feet next to the foundation - typical improper backfill. On the South side of the building near the transformer there is negative grading towards the building. Recommend further evaluation and repair by landscape contractor. Grading / Drainage: Grading / Drainage: PARKING LOT Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ Concrete þ Asphalt Brick Gravel General Deterioration Cracks Settlement The asphalt has typical cracking for its age, recommend sealing. No parking lot drainage issues are evident. There is a stream that runs from the east to the north along the east side of the property. Over one hundred parking spaces with six being handicap. Recycle bins are located on the far south side of the parking lot. Page 3 of 33

ROOFING Monitor Condition ACC MAR NI NP DEF þ Recommend Repairs þ Age : Design Life : 100 % Visible Visual From Ground þ Walked On Ladder at Eaves Snow Covered Asphalt / Composition Wood Shake Wood Shingle Tile Tar and Gravel Metal Rolled Composition Slate þ Membrane þ Suspected Leak(s) Missing Shingle(s) Cupping/Curling/Lifting/Brittle þ Previous Repairs Noted Excessive Granular Loss þ Bubbling Trim Trees / Branches Improper Installation Leaks not always detectable. The roof covering appears to be Modified Bitumen, it appears to be original to the building and is approximately 18 years in age. Cracking and bubbling noted in several areas, some of the cracks appear to be leaking. The roof slopes from front to rear. Some ponding near drains. One plumbing vent flashing has been repaired in an unprofessional manner. Recommend evaluation and repairs completed by a qualified roofing contractor. Noted dissimilar materials used in repairs, see flashing. Roofing : Roofing : Page 6 of 33

EXTERIOR SURFACE þ Monitor Condition þ Recommend Repairs ACC MAR NI NP DEF SIDING/TRIM þ EXTERIOR FAUCETS þ EXTERIOR ELECTRICAL OUTLETS NO GFCI þ EXTERIOR LIGHTING þ Wood Metal Vinyl Stucco Synthetic Stucco Composite Veneer Brick General Deterioration Needs Paint Missing / Loose Cracked Needs Caulk / Seal Poor Earth / Siding Clearance Block exterior in fair conditions, small dings in surface with minimal cracking in surface. The EIFS on the East side of the building has pockets of damage an exposed foam in several areas. Several penetrations in wall surface need to be sealed. Some of the faucet covers are missing and damaged. Exterior outlets are missing covers. Exterior lights appear to be in good condition, not operated. Recommend repairs to the EIFS, sealing penetrations, faucet outlet covers. Exterior Surface: Exterior Surface: Exterior Surface: Exterior Surface: Page 10 of 33

WINDOWS Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ Wood Vinyl Metal Insulated Panes Single Pane Window Wells General Deterioration Needs Caulk / Seal / Damaged Storm Windows Needs Paint / Finish Fogged Painted Shut Metal insulated windows, appear to be in good condition. MAIN DOORS Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ Wood Metal Vinyl Fiberglass General Deterioration Delaminated / Damaged Missing / Damaged Hardware Doorbell Inoperative Screen / Storm Door Damaged Evidence of Leak(s) Repair/Replace Weather-Strip Needs Caulk / Seal Metal frame main doors appear to be in fair condition. The automatic sliding doors operate slowly, may need so adjustments. Fire doors appear to be in good condition, were not operated due to connection to alarm Main Doors: Main Doors: FRIEGHT DOOR Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ Wood Metal Vinyl Fiberglass General Deterioration Delaminated / Damaged Missing / Damaged Hardware Doorbell Inoperative Screen / Storm Door Damaged Evidence of Leak(s) Repair/Replace Weather-Strip Needs Caulk / Seal Metal freight door operates properly and is in fair condition. Page 11 of 33

Frieght Door: Frieght Door: FOUNDATION Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ þ Concrete Block Concrete Slab Post / Pier Brick Stone Wood Insulated Concrete Forms (ICF) General Deterioration Horizontal Cracks Step Cracks Vertical Cracks Limited Observation Needs Caulk / Seal Trim Vegetation Sub-Grade Entryway Foundation appears to be concrete block on a continuous concrete footing. Limited visibility to foundation. Foundation: Damage to the base of the marquis Page 12 of 33

STRUCTURAL FRAME AND BUIILDING ENVELOPE þ Monitor Condition ACC MAR NI NP DEF Recommend Repairs þ þ Concrete Block Concrete Slab Post / Pier Brick Stone Wood Insulated Concrete Forms (ICF) General Deterioration Horizontal Cracks Step Cracks Vertical Cracks Limited Observation Needs Caulk / Seal Trim Vegetation Sub-Grade Entryway Building Envelope is concrete block, appears to be in fair condition. One hairline crack visible on the front of the building, no differential separation. Recommend monitoring for further movement and repair as needed. Structural Frame and Buiilding Envelope : INTERIOR FOUNDATION Monitor Condition ACC MAR NI NP DEF Recommend Repairs General Deterioration Horizontal Cracks Step Cracks Vertical Cracks Limited Observation Leaning / Bowing Inadequate Ventilation Efflorescence / Suspected Leak(s) Page 13 of 33

Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. GRADING / DRAINAGE Positive grading around most of the building with near level conditions. The concrete walks line the building on the west and north sides, asphalt on the rear(east) and the east side is dirt that has settled for the two feet next to the foundation - typical improper backfill. On the South side of the building near the transformer there is negative grading towards the building. Recommend further evaluation and repair by landscape contractor. FENCES / ENCLOSURES No enclosure present, however compactor is located at the rear of the store. The lower portions of the marquis are deteriorated and in need of repair. ROOFING The roof covering appears to be Modified Bitumen, it appears to be original to the building and is approximately 18 years in age. Cracking and bubbling noted in several areas, some of the cracks appear to be leaking. The roof slopes from front to rear. Some ponding near drains. One plumbing vent flashing has been repaired in an unprofessional manner. Recommend evaluation and repairs completed by a qualified roofing contractor. Noted dissimilar materials used in repairs, see flashing. MANSARD ROOF The mansard roof covering is a concrete tile product, at least one broken tile was noted, the remainder of the roof seemed to be in good condition. Recommend replacing broken tile. FLASHING/VALLEYS Flashing appears to be in poor condition, cracking and evidence of ponding water near the drains. Repairs have been made using what appears to be dissimilar material. Please see the plumbing boot comment in the roof section. Recommend evaluation and repairs by a qualified roofing contractor. Page 30 of 33

GUTTERS/DOWN SPOUTS Gutters appear to be in good condition. The area around the drains show signs of ponding. One downspout appears to have received impact blows, doing damage that could affect the flow of water through the downspout. Recommend replacement of the downspout. EXTERIOR SURFACE Siding/Trim Exterior Faucets Exterior Electrical Outlets Block exterior in fair conditions, small dings in surface with minimal cracking in surface. The EIFS on the East side of the building has pockets of damage an exposed foam in several areas. Several penetrations in wall surface need to be sealed. Some of the faucet covers are missing and damaged. Exterior outlets are missing covers. Exterior lights appear to be in good condition, not operated. Recommend repairs to the EIFS, sealing penetrations, faucet outlet covers. Marginal Marginal STRUCTURAL FRAME AND BUIILDING ENVELOPE Marginal Building Envelope is concrete block, appears to be in fair condition. One hairline crack visible on the front of the building, no differential separation. Recommend monitoring for further movement and repair as needed. Main Building - Main Unit WATER HEATER 19 gallon AO Smith water heater, manufactured in 1993 has rust and corrosion on the top sides and bottom of the tank. Appears to be currently holding water, yet rust and water stains on the floor indicate ongoing leakage. Recommend replacement of the water heater. SALES FLOOR Ceilings Several stained ceiling tile should replace when roof repairs complete. Marginal Page 31 of 33

BACK ROOM/STORAGE ROOM Ceilings Noted water stains on ceiling beam over loading area, appears dry at time of inspection. Roof hatch holding latch is not fastened, appears screws have pulled out. Recommend repairs to hatch. EMPLOYEE OFFICE/LOUNGE Interior Doors/Hardware Interior door knob is damaged, recommend repair. MAR (MARGINAL) The item/system was marginally acceptable. (It performed its designed function as of the time of the inspection. However, due to age and/or deterioration, it will likely require early repair or replacement.) DEF (DEFECTIVE) The item/system failed to operate/perform its intended function, was structurally deficient, was unsafe or was hazardous at the time of the inspection. Page 32 of 33