- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3
CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL WINDOW SILL DETAIL REFERENCE SHEETS HO.1 - PANEL PROFILE INFORMATION HA.1 - WINDOW OPENING ISOMETRIC HA.2 - PENETRATION ISOMETRIC HB.1 - PANEL / PANEL OVERLAP SPLICE TRANSITION OPTIONS EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED. IE: DETAIL 1 ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY. WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR / VAPOR S WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES
- WDW OPENING 12F - HA.1 TYPICAL WINDOW OPENING APPLICATION S NOT SHOWN FOR CLARITY FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING WATER RESISTIVE LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING JAMB TRIM FOAM CLOSURE STRIP LOCALIZED FLEXIBLE MEMBRANE METAL STUD METAL SILL FLASHING LOCALIZED FLEXIBLE MEMBRANE WATER RESISTIVE HA.1
- PENETRATION 12F - HA.2 TYPICAL BEAM PENETRATION APPLICATION S NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING LOCALIZED FLEXIBLE MEMBRANE JAMB TRIM w/ FOAM CLOSURE STRIP METAL FLASHING ATTACHMENT FLANGE STRUCTURAL MEMBER CLOSURE PLATE WET SEAL CUT OUT PERIMETER LOCALIZED FLEXIBLE MEMBRANE METAL STUD CFP - 12F EXTERIOR SHEATHING WATER RESISTIVE HA.2
- PANEL SPLICE TYPICAL PANEL / PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE NOTE: WHEN LAPPING PANEL 'C' OVER 'A' THE TOP FASTENER FLANGE AND BOTTOM HOOK FEATURE MUST BE NOTCHED BACK TO CLEAR PANEL "A". ALIGNED JOINTS OR STAGGERED JOINTS ARE APPLICABLE. FURRING OR GIRT "AS REQ'D" BY CODE 12F - HB.1 WALL ASSEMBLY EXTERIOR SHEATHING WATER RESISTIVE UPPER PANEL NOTCH BACK OVERLAP PANEL TOP AND BOTTOM NON-CURRING BUTYL SEAL LOWER LEFT PANEL LOWER RIGHT PANEL 4" LAP MINIMUM HB.1
- PROFILE 12F - H0.1 INSTALL ITEM NUMBER: NET COVERAGE: 12" (1' 0") MAXIMUM LENGTH: (40 feet) MATERIAL OPTIONS COIL - COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM:.032" -.040" FINISH OPTIONS PAINTING "COIL COATED" HYLAR 5000 / KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES. ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY. NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT A CAUSE FOR REJECTION. 3. AN EXTENSIZE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FSMP FOR UP TO DATE TECHINCAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED. H0.1
- Base Detail 12F - H1.1 CONTINUOUS 'Z' GIRT 1/8" x 1" CONT LOCALIZED MEMBRANE EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING METAL FLASHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSIDE THE CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON. 2006 INTERNATIONAL BUILDING CODE - 1403.2 WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT. H1.1
WALL ASSEMBLY TYPE 2 - Base Detail 12F - H1.2 FACE OF PANE.500" MIN AIR SPACE 12.7 mm CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING PRECAST WEEP TUBE & BAFFLE LOCALIZED MEMBRANE METAL FLASHING CONCRETE EXTERIOR SHEATHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS H1.2
- Seam Detail 12F - H2.1 EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) CONTINUOUS HAT CHANNEL 1/8" x 1" CONT VAPOR "OPTIONAL" H2.1
WALL ASSEMBLY TYPE 2 - Seam Detail 12F - H2.2 1/8" x 1" CONT CONTINUOUS 'Z' GIRT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) LOCALIZED MEMBRANE EXTERIOR SHEATHING VAPOR "OPTIONAL".500 MIN AIR SPACE 12.7 mm H2.2
- Seam Detail 12F - H2.3 EXTERIOR SHEATHING 1/8" x 1" CFP-UNA 25 HANGER CLIP BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.3 HANGER CLIP OPTION
- Seam Detail 12F - H2.4 EXTERIOR SHEATHING 1/8" x 1" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.4 DIRECT FASTEN OPTION
- Parapet Roof Detail 12F - H3.1 PRE FINISHED COPING 'J' FLASHING 1/8" x 1" CONT LOCALIZED MEMBRANE ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.1
WALL ASSEMBLY TYPE 2 - Parapet Roof Detail 12F - H3.2 PRE FINISHED COPING 1/8" x 1" CONT LOCALIZED MEMBRANE 'J' FLASHING.500 MIN AIR SPACE 12.7 mm ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.2
- Inside Corner Detail 12F - H4.1 VAPOR "OPTIONAL" METAL CLAD FOAM CLOSURE URETHANE 1/8" x 1" 2.000" 50.8mm ATTACH TRIM BONDING TAPE PRE FINISHED INSIDE CORNER CONTINUOUS HAT CHANNEL INTERIOR DRYWALL EXTERIOR SHEATHING H4.1
WALL ASSEMBLY TYPE 2 - Inside Corner Detail 12F - H4.2 METAL CLAD FOAM CLOSURE URETHANE EXTERIOR SHEATHING 2.000" 50.8mm ATTACH TRIM BONDING TAPE (BY INSTALLER PRE FINISHED INSIDE CORNER CONTINUOUS 'Z' GIRT 1/8" x 1" CONT.500 MIN AIR SPACE 12.7 mm H4.2
- Inside Corner Option 12F - H4.5 FACTORY APPLIED CORNER ANGLE 1/8" x 1" FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY FORMED MITERED 90 INSIDE CORNER CFP - - OPTION 'C' H4.5
- Outside Corner Detail 12F - H5.1 EXTERIOR SHEATHING VAPOR "OPTIONAL" 1/8" x 1" CONTINUOUS HAT CHANNEL ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER URETHANE 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.1
WALL ASSEMBLY TYPE 2 - Outside Corner Detail 12F - H5.2.500 MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING VAPOR "OPTIONAL" ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER 1/8" x 1" URETHANE CONTINUOUS 'Z' GIRT 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.2
- Outside Corner Option 12F - H5.5 FACTORY APPLIED CORNER ANGLE FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY 1/8" x 1" NON-CURRING FORMED MITERED 90 OUTSIDE CORNER CFP - - OPTION 'C' H5.5
- Soffit Detail 12F - H6.1 SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" 1/8" x 1" CONT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED SOFFIT FLASHING 5.000" 127.0mm CONTINUOUS 'J' SHAPE EXTERIOR SHEATHING H6.1
WALL ASSEMBLY TYPE 2 - Soffit Detail 12F - H6.2.500 MIN AIR SPACE 12.7 mm VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) 5.000" 127.0mm PRE FINISHED SOFFIT FLASHING EXTERIOR SHEATHING H6.2
- Window Jamb Detail 12F - H7.1 VAPOR "OPTIONAL" EXTERIOR SHEATHING LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM 1/8" x 1" PREFINISHED JAMB TRIM ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm CONTINUOUS HAT CHANNEL H7.1
WALL ASSEMBLY TYPE 2 - Window Jamb Detail 12F - H7.2 EXTERIOR SHEATHING VAPOR "OPTIONAL" LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM PREFINISHED JAMB TRIM 1/8" x 1" CONTINUOUS 'Z' GIRT.500 MIN AIR SPACE 12.7 mm ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm H7.2
- Window Head Detail 12F - H8.1 EXTERIOR SHEATHING CONTINUOUS 'Z' SHAPE VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.1
WALL ASSEMBLY TYPE 2 - Window Head Detail 12F - H8.2.500 MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING 1/8" x 1" CONT CONTINUOUS 'Z' GIRT VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.2
- Window Sill Detail 12F - H9.1 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT 1/8" x 1" CONT SILL TRIM CLIP (BY SILL TRIM INSTALLER) VAPOR "OPTIONAL" EXTERIOR SHEATHING H9.1
WALL ASSEMBLY TYPE 2 - Window Sill Detail 12F - H9.2 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT SILL TRIM CLIP (BY SILL TRIM INSTALLER) 1/8" x 1" CONT VAPOR "OPTIONAL" EXTERIOR SHEATHING.500 MIN AIR SPACE 12.7 mm H9.2
- Vertical Transitions 12F - H10.1 1/8" x 1" 4.00" MIN LAP NOTCH BACK FASTENING FLANGE AND HOOK FOR OVERLAP CLEARANCE OVERLAP SEAM JOINT CFP - - OPTION 'F' H10.1
- Vertical Transitions 12F - H10.2 URETHANE VHB TAPE 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm 5" FORMED TRANSITION STRIP w/ REVEAL CFP - - STD. DETAIL 3.000" 76.2mm.563" 14.3mm 3" FORMED TRANSITION STRIP w/ SEAL JOINT CFP - - OPTION 'A' H10.2