FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Similar documents
12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

Ameriplate. Rain Screen Wall System

7.0 - EXAMPLE DETAILS

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

WeatherSmart Air Barrier Installation Guide

KS SERIES - VERTICAL INSTALLATION

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ELEVATION FOR DETAIL REFERENCE ONLY

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Ice Rink Renovation & New Clubhouse

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

Architectural Wall Products Guide Specifications

typical section 1:50 Important:

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Student Services & Classroom Addition

Omniplate Barrier Wall System

Ameriplate. Rain Screen Wall System

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

Arcwall. Rain Screen Wall System

CENTRIA Concept Series Metal Wall Panels ZINC

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

GAF EnergyGuard Polyiso Wall Sheathing

Siding and Soffit Installation Guidelines

KARRIER PANEL - BRICK

TYPICAL ROOF CONDITION LAYOUT

Siding and Soffit Installation Guidelines

Prestige Series. (Horizontal Install.) Installation Guide

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CR# August 20, 2015

Metafor Panel System Installation Guide

4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)

Architectural Roof Products Guide Specifications

Proper Installation of Insulated Metal Wall Panels

Ultra Wall System. CAD Detail Sets

DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

The better way to build TM. Installation Manual NAILBASE PANELS

FirstEnergy Program Overview

WrapShield SA Brick Tie Penetration

TW-12. (Horizontal Installation) Installation Guide

CONTOUR CORRUGATED PANEL

Fascia Systems. oofing 7.1

Architectural Roof and Wall Products Guide Specifications

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

Architectural Roof Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

SECTION METAL COMPOSITE MATERIAL WALL PANELS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Arcwall. Rain Screen Wall System

Product and System Specifications DuPont Flashing Systems

Schedule A Development Permit No Issued this 18 day of April, 2018

6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

TremLock TM. Coping. A Pre-engineered Metal Coping System. oofing

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

Guide Specification for the OSI QUAD Window and Door Flashing System

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Stone and Masonry Veneer

200 / 300 SERIES PANELS COLD STORAGE

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

PRE-ENGINEERED METAL BUILDING SYSTEM

Prestige Series 12. Installation guide

Exterior Stucco and Siding Installation

Architectural Roof and Wall Products Guide Specifications

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"

Henri Fennell, CSI/CDT ABX 2015

DIVISION 7 THERMAL AND MOISTURE PROTECTION

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

[Project Name] Section [ ]

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

Container Installation Guide

138 H-STUD AREA SEPARATION WALL SYSTEM

DuPont Tyvek Wall Underlay Install Guide

Dist. by: BEST MATERIALS Ph:

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

ARCHITECTURAL DESIGN GUIDE

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

CENTRIA FORMABOND II Metal Composite Wall System

Transcription:

- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3

CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL WINDOW SILL DETAIL REFERENCE SHEETS HO.1 - PANEL PROFILE INFORMATION HA.1 - WINDOW OPENING ISOMETRIC HA.2 - PENETRATION ISOMETRIC HB.1 - PANEL / PANEL OVERLAP SPLICE TRANSITION OPTIONS EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED. IE: DETAIL 1 ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY. WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR / VAPOR S WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES

- WDW OPENING 12F - HA.1 TYPICAL WINDOW OPENING APPLICATION S NOT SHOWN FOR CLARITY FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING WATER RESISTIVE LOCALIZED FLEXIBLE MEMBRANE METAL FLASHING JAMB TRIM FOAM CLOSURE STRIP LOCALIZED FLEXIBLE MEMBRANE METAL STUD METAL SILL FLASHING LOCALIZED FLEXIBLE MEMBRANE WATER RESISTIVE HA.1

- PENETRATION 12F - HA.2 TYPICAL BEAM PENETRATION APPLICATION S NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS FURRING OR GIRT "AS REQ'D" BY CODE METAL STUD EXTERIOR SHEATHING LOCALIZED FLEXIBLE MEMBRANE JAMB TRIM w/ FOAM CLOSURE STRIP METAL FLASHING ATTACHMENT FLANGE STRUCTURAL MEMBER CLOSURE PLATE WET SEAL CUT OUT PERIMETER LOCALIZED FLEXIBLE MEMBRANE METAL STUD CFP - 12F EXTERIOR SHEATHING WATER RESISTIVE HA.2

- PANEL SPLICE TYPICAL PANEL / PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE NOTE: WHEN LAPPING PANEL 'C' OVER 'A' THE TOP FASTENER FLANGE AND BOTTOM HOOK FEATURE MUST BE NOTCHED BACK TO CLEAR PANEL "A". ALIGNED JOINTS OR STAGGERED JOINTS ARE APPLICABLE. FURRING OR GIRT "AS REQ'D" BY CODE 12F - HB.1 WALL ASSEMBLY EXTERIOR SHEATHING WATER RESISTIVE UPPER PANEL NOTCH BACK OVERLAP PANEL TOP AND BOTTOM NON-CURRING BUTYL SEAL LOWER LEFT PANEL LOWER RIGHT PANEL 4" LAP MINIMUM HB.1

- PROFILE 12F - H0.1 INSTALL ITEM NUMBER: NET COVERAGE: 12" (1' 0") MAXIMUM LENGTH: (40 feet) MATERIAL OPTIONS COIL - COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM:.032" -.040" FINISH OPTIONS PAINTING "COIL COATED" HYLAR 5000 / KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES. ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY. NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT A CAUSE FOR REJECTION. 3. AN EXTENSIZE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FSMP FOR UP TO DATE TECHINCAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED. H0.1

- Base Detail 12F - H1.1 CONTINUOUS 'Z' GIRT 1/8" x 1" CONT LOCALIZED MEMBRANE EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING METAL FLASHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS PRECAST WEEP TUBE & BAFFLE CONCRETE IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSIDE THE CAVITY SHOULD USE A VAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON. 2006 INTERNATIONAL BUILDING CODE - 1403.2 WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT. H1.1

WALL ASSEMBLY TYPE 2 - Base Detail 12F - H1.2 FACE OF PANE.500" MIN AIR SPACE 12.7 mm CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED BASE FLASHING PRECAST WEEP TUBE & BAFFLE LOCALIZED MEMBRANE METAL FLASHING CONCRETE EXTERIOR SHEATHING VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS H1.2

- Seam Detail 12F - H2.1 EXTERIOR SHEATHING BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) CONTINUOUS HAT CHANNEL 1/8" x 1" CONT VAPOR "OPTIONAL" H2.1

WALL ASSEMBLY TYPE 2 - Seam Detail 12F - H2.2 1/8" x 1" CONT CONTINUOUS 'Z' GIRT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) LOCALIZED MEMBRANE EXTERIOR SHEATHING VAPOR "OPTIONAL".500 MIN AIR SPACE 12.7 mm H2.2

- Seam Detail 12F - H2.3 EXTERIOR SHEATHING 1/8" x 1" CFP-UNA 25 HANGER CLIP BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.3 HANGER CLIP OPTION

- Seam Detail 12F - H2.4 EXTERIOR SHEATHING 1/8" x 1" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) VAPOR "OPTIONAL" H2.4 DIRECT FASTEN OPTION

- Parapet Roof Detail 12F - H3.1 PRE FINISHED COPING 'J' FLASHING 1/8" x 1" CONT LOCALIZED MEMBRANE ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.1

WALL ASSEMBLY TYPE 2 - Parapet Roof Detail 12F - H3.2 PRE FINISHED COPING 1/8" x 1" CONT LOCALIZED MEMBRANE 'J' FLASHING.500 MIN AIR SPACE 12.7 mm ROOFING MEMBRANE WOOD BLOCKING SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS EXTERIOR SHEATHING FIRE RATED PLYWOOD VAPOR "OPTIONAL" H3.2

- Inside Corner Detail 12F - H4.1 VAPOR "OPTIONAL" METAL CLAD FOAM CLOSURE URETHANE 1/8" x 1" 2.000" 50.8mm ATTACH TRIM BONDING TAPE PRE FINISHED INSIDE CORNER CONTINUOUS HAT CHANNEL INTERIOR DRYWALL EXTERIOR SHEATHING H4.1

WALL ASSEMBLY TYPE 2 - Inside Corner Detail 12F - H4.2 METAL CLAD FOAM CLOSURE URETHANE EXTERIOR SHEATHING 2.000" 50.8mm ATTACH TRIM BONDING TAPE (BY INSTALLER PRE FINISHED INSIDE CORNER CONTINUOUS 'Z' GIRT 1/8" x 1" CONT.500 MIN AIR SPACE 12.7 mm H4.2

- Inside Corner Option 12F - H4.5 FACTORY APPLIED CORNER ANGLE 1/8" x 1" FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY FORMED MITERED 90 INSIDE CORNER CFP - - OPTION 'C' H4.5

- Outside Corner Detail 12F - H5.1 EXTERIOR SHEATHING VAPOR "OPTIONAL" 1/8" x 1" CONTINUOUS HAT CHANNEL ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER URETHANE 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.1

WALL ASSEMBLY TYPE 2 - Outside Corner Detail 12F - H5.2.500 MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING VAPOR "OPTIONAL" ATTACH TRIM W/BONDING TAPE PRE FINISHED OUTSIDE CORNER 1/8" x 1" URETHANE CONTINUOUS 'Z' GIRT 3.000" 76.2mm METAL CLAD FOAM CLOSURE H5.2

- Outside Corner Option 12F - H5.5 FACTORY APPLIED CORNER ANGLE FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY 1/8" x 1" NON-CURRING FORMED MITERED 90 OUTSIDE CORNER CFP - - OPTION 'C' H5.5

- Soffit Detail 12F - H6.1 SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS VAPOR "OPTIONAL" 1/8" x 1" CONT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PRE FINISHED SOFFIT FLASHING 5.000" 127.0mm CONTINUOUS 'J' SHAPE EXTERIOR SHEATHING H6.1

WALL ASSEMBLY TYPE 2 - Soffit Detail 12F - H6.2.500 MIN AIR SPACE 12.7 mm VAPOR "OPTIONAL" SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS CONTINUOUS 'Z' GIRT 1/8" x 1" CONT BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) 5.000" 127.0mm PRE FINISHED SOFFIT FLASHING EXTERIOR SHEATHING H6.2

- Window Jamb Detail 12F - H7.1 VAPOR "OPTIONAL" EXTERIOR SHEATHING LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM 1/8" x 1" PREFINISHED JAMB TRIM ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm CONTINUOUS HAT CHANNEL H7.1

WALL ASSEMBLY TYPE 2 - Window Jamb Detail 12F - H7.2 EXTERIOR SHEATHING VAPOR "OPTIONAL" LOCALIZED MEMBRANE WINDOW/DOOR SYSTEM PREFINISHED JAMB TRIM 1/8" x 1" CONTINUOUS 'Z' GIRT.500 MIN AIR SPACE 12.7 mm ATTACH TRIM W/BONDING TAPE 2.000" 50.8 mm H7.2

- Window Head Detail 12F - H8.1 EXTERIOR SHEATHING CONTINUOUS 'Z' SHAPE VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.1

WALL ASSEMBLY TYPE 2 - Window Head Detail 12F - H8.2.500 MIN AIR SPACE 12.7 mm EXTERIOR SHEATHING 1/8" x 1" CONT CONTINUOUS 'Z' GIRT VAPOR "OPTIONAL" BUTYL / HOTMELT (FACTORY OR FIELD APPLIED) PREFINISHED FLASHING WINDOW/DOOR SYSTEM SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS LOCALIZED MEMBRANE H8.2

- Window Sill Detail 12F - H9.1 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT 1/8" x 1" CONT SILL TRIM CLIP (BY SILL TRIM INSTALLER) VAPOR "OPTIONAL" EXTERIOR SHEATHING H9.1

WALL ASSEMBLY TYPE 2 - Window Sill Detail 12F - H9.2 WINDOW/DOOR SYSTEM SILL TRM ATTACHMENT REVIT SILL TRIM CLIP (BY SILL TRIM INSTALLER) 1/8" x 1" CONT VAPOR "OPTIONAL" EXTERIOR SHEATHING.500 MIN AIR SPACE 12.7 mm H9.2

- Vertical Transitions 12F - H10.1 1/8" x 1" 4.00" MIN LAP NOTCH BACK FASTENING FLANGE AND HOOK FOR OVERLAP CLEARANCE OVERLAP SEAM JOINT CFP - - OPTION 'F' H10.1

- Vertical Transitions 12F - H10.2 URETHANE VHB TAPE 2.000" 50.8mm 1.000" 25.4mm 5.000" 127.0mm 2.000" 50.8mm 5" FORMED TRANSITION STRIP w/ REVEAL CFP - - STD. DETAIL 3.000" 76.2mm.563" 14.3mm 3" FORMED TRANSITION STRIP w/ SEAL JOINT CFP - - OPTION 'A' H10.2