CS-195+ Composite Sheet FR Board

Similar documents
3M CS-195+ Composite Sheet Product Description

3M Fire Barrier Pillows Product Description

FirePillow-240. Temporary or permanent fire barriers for all types of penetrations and services Approved to AS Technical Data Sheet

3M Fire Barrier Sealant IC 15WB+

3M Fire Barrier Mouldable Putty

3M Fire Barrier Pass-Through Device Product Description

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

Intumescent Fire Dampers

Rainscreen Ventilated Fire Barrier

REGULATORY INFORMATION REPORT

Fire-Rated Bulkhead Batt

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax:

3M Fire Protection Products. Confidence. Even Under Fire. Principal Products Ltd I Ph: I

Protecting clusters of electrical, data, comms cables, cable trays, conduit and metal pipes from fire and smoke Tested to AS1530.

Fire Protection Product Applications by Contractor Trades Through Penetrations & Joints

FIRESTOP AND FIRE PROTECTION

Visit 3M Electrical Fire Protection Solutions Pages.

Fire Protection Products

LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT

REGULATORY INFORMATION REPORT

Firestop and Fire Protection Systems

PASSIVE FIRE PROTECTION PRODUCTS

Duct Wrap Flexible Wraps

System No. C-AJ-8096

/ADF BuyLine 1632 FIREBARRIER FIRESTOP SYSTEMS

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

PASSIVE FIRE PROTECTION PRODUCTS

INTUMESCENT PILLOWS Temporary firestop solution for large voids in walls & floors

Fire Barrier 3000 WT Intumescent Silicone Sealant

ASSESSMENT REPORT. EWFA Report No: Report Sponsor: 3M New Zealand 94 Apollo Drive, Rosedale Auckland, New Zealand

BlazeBrake. Fire Protection Systems. Retrofit Fire Rated Devices for Cable & Pipe Services

FIRE RATING MATERIAL FIXING NOTES

FlexiCoat-MAK. Technical Data Sheet

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings

Not to be distributed outside of FM Global except by Customer

Technical Data Sheet. Hilti CFS-CU Firestop Cushion. European technical approval ETA N o 08/0213. Issue 04 / Hilti Firestop Cushion CFS-CU

St. Monica Food Pantry

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

DECEMBER Phone: Fax:

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

System No. W-J-4050 ANSI/UL1479 (ASTM E814) CAN/ULC S115 4F2 4E. Reproduced by HILTI, Inc. Courtesy of. Underwriters Laboratories, Inc.

System No. C-AJ-8133

LOW PROFILE PIPE COLLARS

Fire Barrier CP25WB+ Sealant

FIRESTOPPING & SMOKE SEALS

LOW PROFILE PIPE COLLARS

Promat PROMASEAL Fire Barrier

Firebreak 22 Fire Resistant Acoustic Sealant. Rigid (concrete) floors of 150mm minimum thickness

FIRESTOP SUBMITTAL PACKAGE

Shared Services Partnership

ASF FR Board PRO RANGE Coated Mineral Wool Board for the Professional

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

PFC Corofil Coated Panel System

FIRESTOP SUBMITTAL PACKAGE

FIRE TEST REPORT FP 5663

REGULATORY INFORMATION REPORT

Promaseal pillows. progressivematerials.com.au

System No. C-AJ-8048

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

SECTION SOUND ISOLATION

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

Product Catalogue 2017

Fire Rated Glazing System Guide

BICSI March 19 th, 2009 Canadian Regional Meeting NBCC Moncton, New Brunswick. Firestop, it s not Magic It s understanding!

Thermasheath-XP. Insulation for Exposed Use

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

FYREBOX TECHNICAL MANUAL. Changing the way we build to improve fire safety. MAXI AND MINI. fyrebox.com.au firebox.com.au

FIRESTOP 101: An Introduction to Firestopping

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

ASSESSMENT REVIEW. Review of assessment report BWA and Regulatory Information Report RIR

UL Design System HW-D-1012 continued

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION HVAC INSULATION

Sarking & Insulation Products A Blue Chip Company

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

JAN Firestopping Standard Details

CERTIFICATE OF APPROVAL No CF 5363 NULLIFIRE LIMITED

Concrete Soffit Direct Fix

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

ATT-TP Section F

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

Common Firestop Issues in Wood Framed Commercial Construction

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816)

A. AISI Specifications for Design of Cold-Formed Steel Structural Members

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

Date of update January 25, 2018 Valid until

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.

Fire performance of curtain walls and rainscreens

System No. SP777 (FOR HORIZONTAL OR VERTICAL SEPARATIONS)

UL-listed fire ratings 1, 2 and 3 hours Excellent sound ratings STC and IIC Manufactured from recycled steel. 48" to 72" joist spacing, longer spans

For inhibiting the spread of fire and smoke in concealed spaces

DECLARATION OF PERFORMANCE

Technical Data Sheet. Hilti Firestop cable collar CFS-CC. European technical approval ETA N o 13 / Issue 10 / 2013

CERTIFICATE OF APPROVAL No CF 5034 FISCHERWERKE GMBH & CO. KG.

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

Firestopping Standard Details

Transcription:

CS-195+ Composite Sheet FR Board Durable, Steel-lined Fire-Rated Board for up to 4 hours fire protection Tested to AS1530.4, EN1366 and UL Listed Technical Data Sheet a product Light. Strong. Durable.

KEY BENEFITS - Intumescent, elastomeric sheet gives superior fire protection - 30 gauge gal steel face gives strength and durability - Protects around HVAC ducts and penetrating services - Excellent fire-break for both vertical and horizontal penetrations - Approved to AS1530.4, EN1366 and UL Listed - See MORE benefits below INTRODUCTION It is use for the following applications: Shielding cable trays and conduit HVAC ductwork Vital process equipment Protects against radiant heat, flame spread and smoke Ideal for new installations and retrofit applications Provides up to 4hr fire rating 3M Fire Barrier CS-195+ Composite Sheet is a one-part composite board system comprised of four elements. 1. The heart of the system is an organic/inorganic, fire-resistive elastomeric sheet. 2. Bonded on one side to a layer of 30 gauge galvanized steel. 3. Reverse face is reinforced with hexagonal shaped steel-wire mesh 4. Wire mesh is veneered with industrial aluminium foil APPLICATION CS-195+ Composite Sheet is designed to offer a fire and smoke seal in larger penetrations through fire-rated walls and floors. When exposed to temperatures in excess of 121 C, the fire-resistive sheet begins to volumetrically expand and swells 8-10 times its original size, forming a high strength, hard char that retards heat transmission. This expansion process is called intumescence. Under normal operating conditions, CS-195+ Composite Sheet is a good thermal conductor which allows unwanted heat build-up to escape from process and control equipment and also minimizes power cable de-rating. MORE BENEFITS Light weight, with excellent strength to weight comparative benefits Seals large penetration in walls and around trays and cables Protects against radiant heat, flame spread and smoke Easily installed with common trade tools Copyright 2014 2

PRODUCT FEATURES PHYSICAL SPECIFICATION Intumesces to form a hard char that tightly seals penetrations against flame spread, smoke and toxic fumes Multiple applications penetration firestop, heat shield and firebreak protection Easy to install using common trade tools Lightweight easy to handle, cut and form to desired shape Easy to fasten bolt punch or drill through. Use self-tapping screws or anchor bolts Thermally conductive allows unwanted heat build-up to escape Non-flame supporting Cost effective, high performance versus installed cost No mixing or damming is clean to install Versatile: can be cut to fit irregular shapes Re-enterable Low odour Tested in accordance with AS1530.4, EN1366 and ASTM E814 (UL Listed). Sheet Sizes 406.4mm x 711.2mm 711.2mm x 1320.8mm 914.4mm x 609.6mm 914.4mm x 914.4mm 914.4mm x 1041mm Component Galvanised sheet steel Fire-resistive sheet Hexagonal restraining wire 20 gauge Aluminium foil Complete material Thickness 0.399mm +/- 0.076mm 30 gauge 7.24mm +/- 1.27mm 0.0508mm +/- 0.00508mm 7.70mm +/- 1.37mm A.Physical and Electrical Properties as installed Normal weight 13.4 kg/m 2 Intumescent Activation Sequence STORAGE 3M Fire Barrier CS-195+ Composite Sheet remains stable for an indefinite period of time. CS-195+ Composite Sheet should be stored in the original shipping container until used. The materials are non-impaired by freezing or storage at temperatures up to 86 o C. Expansion begins Significant expansion Weight loss (TGA) Expansion 150 o C 177 o C 20% @ 350 o C 31% @ 500 o C 53.2% @ 1000 o C 8-10 Typical Intumescent Sheet Properties (as part of composite) Domestic Strength (ASTD 149) 119 volts/mil average Non-flame supporting hardness 45 to 65 Shore A Tensile strength/elongation (ASTM D 142, Method A) Compression set Surface burning characteristics ASTM E 84 (ANSI/UL 723) 0.645 MPa (93.6 psi)/489% 25% (maximum) Flame Speed 5 Smoke Development 50 Copyright 2014 3

INSTALLATION 1. For drywall constructions, add metal framing to the top and bottom of the opening. If metal studs are used, the top (flat) surface should be facing toward and flush with the opening, and the channel of the stud should be facing into the wall cavity. 2. Wrap cables and metal pipes with a single layer of 3M Fire Barrier Moldable Putty+ Pad for the full depth of the seal. 3. Install 3M Fire Barrier FS-195+ Wrap/Strip around cables and metal pipes on both sides of the fire seal. Use steel wire to hold the FS-195+ Wrap/Strip in place. 4. Use cardboard, marking pencils and scissors to make templates of the exact size and shape of CS-195+ Composite Sheet pieces. Ensure that a 50mm overlap is allowed around the sides of the opening. The template will generally need to be made in at least two pieces. Plan the size of the first piece so only one piece requires contour cuts. The fewer pieces that need contour cuts, the quicker the installation will be. 5. Use a jigsaw to cut the CS-195+ Composite Sheet to the cardboard template. 6. Run a bead of 3M CP 25WB+ Sealant around the opening within 50mm of the edge. 7. Secure the CS-195+ Composite Sheet into place using 6mm steel fasteners with washers placed with 150mm spacing around the opening. Ensure that there is at least 50mm overlap around the opening. 8. Use 40mm wide steel sheet metal strips and sheet metal screws to cover the CS-195+ Composite Sheet seams. 9. Apply Fire Barrier CP 25WB+ Sealant around the cable tray and fill spaces between CS-195+ Composite Sheet and FS-195+ Wrap/Strip. Also, cover edges of the Wrap/Strip and fill any spaces that smoke would likely penetrate. Copyright 2014 4

Performance Specifications for Installers Australian Standard FRLs: 3M CS-195 Composite Sheet Building Element Floor: Concrete slab. Minimum 120mm thickness Wall: Plasterboard Dry Wall Minimum 116mm thickness Wall: Solid masonry, hollow masonry or concrete construction. Minimum 116mm thickness Blank (Unpenetrated) Seal PVC Insulated Cables, Cable trays and Cable bundles Copper or Steel Pipes Small* 15mm diameter or smaller 0.9mm wall thickness or thicker -/240/120 -/180/30 -/240/- -/240/- -/120/30 -/120/30 -/120/- -/120/- -/240/90 -/180/30 -/180/- -/180/- Steel Pipes Small* 34mm diameter or smaller 3.5mm wall thickness or thicker In order to achieve the above FRLs you must ensure that the CS-195+ Composite Sheet is installed as per the Installation Techniques and the building element you are installing into has an FRL performance equal to or better than that of the CS-195+ system. The Installation Techniques can be found on the final page of this document. What does FRL mean? FRL stands for Fire Resistance Level. For example, an FRL of -/240/120 indicates: Structural Adequacy. The first dash - indicates that CS-195+ is non load bearing Integrity. The middle number 240 indicates for how many minutes the CS-195+ system can resist the passage of flames and hot gasses Insulation. The last number 120 indicates how many minutes it takes the unexposed face to heat up by more than 180 o C. Copyright 2014 5

Performance Specifications for Engineers and Specifiers 3M Fire Barrier CS-195+ Composite Sheet has been tested in accordance with AS1530.4-2005 and assessed in accordance with AS4072.1-2005 under BWA Report No: 22695. The following illustrations provide a summary of the test results for D1 and D2 cable configurations, metal pipe penetrations and blank unpenetrated seals with CS-195+ installed as per the Installation Techniques. Specifications for standard D1 and D2 cable configurations can be found in AS1530.4-2005 Appendix D. D1 Cable Pack Power Transmission Cables D2 Cable Pack Telecom Cables Blank Openings (unpenetrated) Copyright 2014 6

SIZES AVAILABLE Product Code Packing Sizes Unit CS - 406711 Boxed 406.4mm x 711mm 1 CS - 7111321 Boxed 711mm x 1321mm 1 CS - 914610 Boxed 914.4mm x 610mm 1 CS - 914914 Boxed 914.4mm x 914.4mm 1 CS - 9141641 Boxed 914.4mm x 1041.4mm 1 FURTHER TECHNICAL INFORMATION For additional technical information on the performance of CS-195+ Composite Sheet FR Board or other BOSS products please contact our Technical Services team on: Phone 1300 502 677 Fax 1300 602 677 Direct +612 9531 8591 Email info@bossfire.com.au Web www.bossfire.com.au HEALTH AND SAFETY To learn more about the safe handling of CS-195+ Composite Sheet FR Board, see the Material Safety Data Sheet available at www.bossfire.com.au. LIMITATION BOSS Fire & Safety Pty Ltd has provided the above technical information in good faith and to the best of its knowledge. This information was deemed to be correct at the time of publication. Should any data come to BOSS Fire & Safety s attention relating to the fire resistance or performance of the product described, BOSS Fire & Safety reserve the right to amend this report. BOSS Fire & Safety strive to constantly improve and develop products so this information may change without notice. Copyright 2014 7