Study on the settlement and the load-bearing capacity of Long An soft ground reinforced by the stone columns

Similar documents
ScienceDirect. Determine Load Capacity of Pressed Piles Using Method

Behavior of Stone Columns Based on Experimental and FEM Analysis

CHAPTER 2 LITERATURE REVIEW

EFFECT OF DEEP EXCAVATION SUPPORTED BY CONCRETE SOLIDER PILE WITH STEEL SHEET PILE LAGGING WALL ON ADJACENT EXISTING BUILDINGS

Pile foundations Introduction

BEARING CAPACITY IMPROVEMENT USING MICROPILES A CASE STUDY

Evaluation of negative skin friction on sheet pile walls at the Rio Grande dry dock, Brazil

VOL. 11, NO. 16, AUGUST 2016 ISSN ARPN Journal of Engineering and Applied Sciences

Comparison of the results of load test done on stone columns and rammed aggregate piers using numerical modeling

Modelling of Piled Raft Foundation on Soft Clay

Effect of Soil Reinforcement on Shear Strength and Settlement of Cohesive- Frictional Soil

Response of Circular Footing by Varying the Vertical Spacing of Reinforcement Resting on Structural Fill

SETTLEMENT RATIO OF FLOATING STONE COLUMNS FOR SMALL AND LARGE LOADED AREAS

Behaviour of Strip Footing on Geogrid Reinforced Slope subjected to Eccentric Load

Static Response of Reinforced Soil Retaining Walls with Modular Block Facing

Analysis of skin friction in prebored and precast piles

Performance of Reinforced Earth Retaining Wall with Fly Ash under Static and Dynamic Loading

Investigation of Bearing Capacity and Settlement of Strip Footing on Clay Reinforced with Stone Columns

A Study on the Behaviour of Geogrid Encased Capped Stone Columns by the Finite Element Method

Evaluation on Bearing Capacity of Ring Foundations on two-layered Soil

BEHAVIOUR OF SQUARE FOOTING RESTING ON TWO LAYERED CLAY DEPOSITS. Dr. Sunil S. Pusadkar 1, Sheetal M. Baral 2 ABSTRACT

BEHAVIOUR OF GEOTEXTILE REINFORCED STONE COLUMNS MANITA DAS, A.K.DEY ABSTRACT

CASE STUDY ON DIFFERENT GROUND IMPROVEMENT TECHNIQUES FOR A PROPOSED BUILDING ABSTRACT

Behaviour of Raft Foundation with Vertical Skirt Using Plaxis 2d

Behavior of pile due to combined loading with lateral soil movement

3d Numerical Analysis of Bearing Capacity of Square Foundations on Geogrid Reinforced Soil


A Parametric Study on Behaviour of Geogrid Reinforced Earth Retaining Wall

Monitoring and numerical investigations of rigid inclusion reinforced concrete water tanks

[Kouravand Bardpareh* et al., 5(6): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

DISPLACEMENT OF DIAPHRAGM WALL FOR VERY DEEP BASEMENT EXCAVATION IN SOFT BANGKOK CLAY

Bearing Capacity of Geosynthetic Reinforced Foundation Beds on Compressible Clay

Parametric Study on Geogrid-Reinforced Track Substructure

NUMERICAL STUDY OF OFFSHORE SKIRTED FOUNDATIONS SUBJECTED TO COMBINED LOADING

NUMERICAL MODELLING OF HIGHWAY EMBANKMENT BY DIFFERENT GROUND IMPROVEMENT TECHNIQUES

Downloaded from Downloaded from /1

Numerical Modeling the Behavior of Ground Improvement in Soft Clay

Suitability of Different Materials for Stone Column Construction

Analysis of T-Shape Footing On Layered Sandy Soil

Compressibility of Soil. Chapter 11

Evaluation of Geosynthetic Forces in GRSRW under Dynamic Condition

BRE Seminar Ground treatment - Getting the best from difficult sites A Reality Check What Does the Designer Need to Know?

NUMERICAL STUDY OF FLOATING STONE COLUMNS

(Received 05 February, 2013, Accepted 20 March, 2013)

GEOTECHNICAL ENGINEERING CHALLENGES ON SOFT GROUND. For Myanmar Engineering Society 2012 CONTENTS

FOUNDATION ENGINEERING UNIT -1 SITE INVESTIGATION & SELECTION OF FOUNDATION 1. What are components of total foundation settlement?

Numerical Analysis of Piles in Layered Soils: A Parametric Study By C. Ravi Kumar Reddy & T. D. Gunneswara Rao K L University, India

Numerical Modeling of Geogrid Reinforced Soil Bed under Strip Footings using Finite Element Analysis

The use of flexible flaps in improving the settlement resistent behaviour of raft foundations

Response of Piered Retaining Walls to Lateral Soil Movement Based on Numerical Modeling

Input Parameters for the Design of Stone Columns

IGC. 50 th INDIAN GEOTECHNICAL CONFERENCE BEHAVIOUR OF GEOTEXTILE ENCASED QUARRY WASTE COLUMN SUBJECTED TO SHEAR LOADING IN SOFT CLAY

Performance of axially loaded single pile embedded in cohesive soil with cavities

THREE DIMENSIONAL BEARING CAPACITY ANALYSIS OF GRANULAR SOILS, REINFORCED WITH INNOVATIVE GRID-ANCHOR SYSTEM *

PARAMETRIC STUDY OF SHALLOW FOUNDATION BEARING CAPACITY IN CLAYEY SOIL

Numerical Analysis of the Bearing Capacity of Strip Footing on Reinforced Soil Slope

Foundation Engineering

b e a r i n g c a p a c i t y o f g e o p i e r - s u p p o r t e d f o u n d a t i o n s y s t e m s

EFFECT OF REINFORCEMENT, BACKFILL AND SURCHARGE ON THE PERFORMANCE OF REINFORCED EARTH RETAINING WALL

Evaluation of the Behavior of Geo-Synthetic Reinforced Soil Wall with Improved Soil as Backfill

Case study on a deep excavation in Baku: Flame Towers project earth retaining system

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

CEX6230 GEOTECHNICS Dear Student:

A Case Study: Foundation Design in Liquefiable Site

Behaviour of Reinforced Soil Retaining Walls under Static Loads by Using Plaxis

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil

COURSE ON COMPUTATIONAL GEOTECHNICS A Geotechnical Design Tool. Faculty of Civil Engineering UiTM, Malaysia

Improving Engineering Properties of Soft Soil Using Preloading and Prefabricated Vertical Drains

PILE RAFT FOUNDATION BEHAVIOR WITH DIFFERENT PILE DIAMETERS

GROUND ENGINEERING. Vibro Ground Improvement

A Short State-of-the-Art Review on Construction and Settlement of Soft Clay Soil Reinforced with Stone Column

The Bearing Capacity of Soils. Dr Omar Al Hattamleh

Typical set up for Plate Load test assembly

Geotechnical Solutions for High Speed Track Embankment A Brief Overview

RIGID INCLUSIONS. Rigid Inclusions offer an economical approach for building on sites underlain by soft soil.

Effect of Cavities on the Behaviour of Strip Footing Subjected to Inclined Load

LABORATORY STUDY OF FINE GRAINED SOIL IMPROVEMENT USING LIME MORTAR STONE COLUMNS

Two-dimensional finite element analysis of influence of plasticity on the seismic soil micropiles structure interaction

A STUDY ON GROUND IMPROVEMENT USING STONE COLUMN TECHNIQUE

EFFECT OF SOIL CEMENT COLUMN SPACING AND AREA REPLACEMENT RATIO ON EMBANKMENT BEARING CAPACITY: A QUEENSLAND CASE STUDY

GROUND IMPROVEMENT USING DYNAMIC REPLACEMENT FOR NCIG CET3 COAL STOCKYARD

SUBSOIL IMPROVEMENT WORKS AT DVIZ, HAIPHONG, VIETNAM

DHANALAKSHMI COLLEGE OF ENGINEERING, CHENNAI DEPARTMENT OF CIVIL ENGINEERING 2 MARK QUESTIONS WITH ANSWERS CE FOUNDATION ENGINEERING UNIT 1

Site Response and Shear Behavior of Stone Column-Improved Ground under Seismic Loading

SETTLEMENTS DUE TO TUNNEL CONSTRUCTION

Hoang-Hung Tran-Nguyen*, Bao Khac Le & Long Phi Le

1G Model Study on the behavior of Piled Raft Foundation

Finite Element Analysis of Flexible Anchored Sheet Pile Walls: Effect of Mode of Construction and Dewatering Naveen Kumar 1, Arindam Dey 2*

IOP Conference Series: Materials Science and Engineering. Related content PAPER OPEN ACCESS

1. limit equilibrium bearing capacity failure modes

Behavior of Reinforced Embankment on Soft Ground with and without Jet Grouted Soil-Cement Piles

AGGREGATE COLUMNS DESIGN GUIDANCE

Relationship between twin tunnels distance and surface subsidence in soft ground of Tabriz Metro - Iran

Brochure E. Deep Vibro Techniques

Finite Element Analyses of Granular Pile Anchors as a Foundation Option for Reactive Soils

Soil Improvement Using Vibro-Replacement

Behaviour of rigid retaining wall with relief shelves with cohesive backfill

Hiep Van Le Department of Geotechnical Engineering, University of Transport Technology, 54 TrieuKhuc, ThanhXuan, Ha Noi, Viet Nam

SEEPAGE FLOW-STABILITY ANALYSIS OF THE RIVERBANK OF SAIGON RIVER DUE TO RIVER WATER LEVEL FLUCTUATION

Effect of Ground Subsidence on Load Sharing and Settlement of Raft and Piled Raft Foundations

Transcription:

Japanese Geotechnical Society Special Publication International Mini Symposium CHUBU (IMS-CHUBU) Study on the settlement and the load-bearing capacity of Long An soft ground reinforced by the stone columns Le Ba Vinh i), Le Ba Khanh ii) i) Associate Professor, Department of Civil Engineering, Viet Nam National University, 68 Ly Thuong Kiet, Ho Chi Minh City. ii) Ph. D, Department of Civil Engineering, Viet Nam National University, 68 Ly Thuong Kiet, Ho Chi Minh City. ABSTRACT Soft soil reinforcement methods by using the granular piles are very popular by improving the strength and deformation characteristics of the soft soils. There were many analytical methods such Aboshi, Priebe, Vesic, Barksdale and Bachus s method to estimate the settlement and the load-bearing capacity of soft grounds reinforced by the stone columns. This paper analyzes the applicability of these methods, well the finite element method, via software PLAXIS 3D Foundation, with a real construction in Long An, Mekong delta, Viet Nam. The back analysis of meured settlements by applying Asaoka method showed a remarkable difference between the calculated and the observed settlements. The load-bearing capacity tests of the stone columns were carried out to confirm the real bearing capacity and failure mechanism of the stone columns. Finally, the recommendations to determine the settlement and the load-bearing capacity of soft grounds reinforced by the stone columns are proposed. Keywords: stone columns, settlement, load-bearing capacity, analytical method, shear failure. 1 INTRODUCTION In order to calculate the load bearing capacity of the stone columns, there are many analytical methods such Greenwood, Vesic, Barksdale and Bachus s method. Several methods have been proposed for estimating the settlement of cohesive soils improved by stone columns (e. g Aboshi et al., 1979; Priebe, 1995; Van Impe and De Beer, 1983). The calculated results by these methods are quite different in many ces. In order to evaluate the applicability of these methods, the analyses have been carried out with an actual project. The calculated results have been compared with the results of numerical simulations using finite element method, and the field test results. Bed on these analyses, the proposals for calculating the settlement and the load-bearing capacity of soft grounds reinforced by the stone columns have been presented. APPROACH OF SETTLEMENT ANALYSIS In order to predict the settlement of a soft ground reinforced by the stone columns, there are some well-known methods which are widely used in the world follows: Table 1. Typical calculation methods of settlement. Method Content Equilibrium t mv c H. S method R = c = (Aboshi,..., 1979) Priebe 1 method f s. 1 1 (Priebe, R ( K A) s. f s. 1995) 1 1 f s. [ ].[ 1 1 a s ( K A) tg 45 Granular wall method (Van Impe and De Beer, 1983) RH 1 1 1 E S t R f, s,, E.1 a s s ] 3 LOAD-BEARING CAPACITY ANALYSIS OF A SINGLE STONE COLUMN In ce the tip of the stone column is resting on a firm http://doi.org/1.38/jgssp.v5.3 14

Fig. 1. Vesic cylindrical cavity expansion factors. Fig.. Mechanism of failure of short column, Vitkar 1978. Fig. 3. Bearing Capacity Factor, Nc. Fig. 4. Bearing Capacity Factor N, Nq. 15

bearing layer, the bulging failure or the shear failure often develops in the improved ground. 3.1 Load-bearing capacity, the ce of bulging failure Vesic, 197 proposed the formula of ultimate load-bearing capacity follow: 1 sin q s ult c.f c q.f q x 1 sins (1) where: c = cohesion, q = mean (isotropic) stress, 1 q 3 at the equivalent failure depth, F, F 3 c q = cavity expansion factors. The cavity expansion factors F, shown in Fig.1 are a function of the angle of c F q internal friction of the surrounding soil and the rigidity index, I. The rigidity index, not reduced for the effects of volume change in the pltic zone, is expressed : E Ir 1 vc qtanc () where: E = modulus of elticity of the surrounding soil in which cavity expansion is occurring, v - Poissons ratio of the surrounding soil. Besides Vesic, there are also another methods of Greenwood 1983, Hughes 1979, Barksdale and Bachus 1983, etc. 3. Load-bearing capacity, the ce of shear failure Vitkar, 1978 proposed the formula of ultimate load-bearing capacity follow: qult where: N, N c, Nq Fig. 3 and Fig. 4. 1 cbn cnc D f cnq (3) are bearing capacity factors given in 4 BEHAVIOURS OF STONE COLUMN IMPROVED SOFT GROUND, A CASE STUDY 4.1 Introduction of a project With a total area of approximately 64,m, VIFON II project w planned with two main factories - one for rice-related products and the other for instant noodle products - covered up to 33,m. Fig. 5 shows the general plan layout of the future project. The factory is designed with different loading are from 1kN/m to 4kN/m. The soft ground is reinforced by the stone columns with a diameter of.65m and average length of 3.3m. The stone columns are designed and constructed by BACHY SOLETANCHE VIET NAM, and arranged in square grids with the spacing from 1.7m to.5m in accordance with each service load ce. 4. Geological condition The soil layers and its parameters are shown in Table. (Duong Chung Nguyen, 13). Fig. 5. VIFON II factory plan layout. Table. Soil parameters of the ground. Soil Type Sand Sandy Stone (Back Clay Clay Clay column filling) Thickness (m).5 3.3 3. 6. 3.3 w (%) - 31. 4.51.56 c (kn/m³) 18 18.54 19.75.3 c,sat (kn/m³) 18 18.97.5.48 e -.931.719.69 - Ip - 19.1 19.16 13.83 - k h (m/day) 1 3E-4 6E-5 1E-5 1 k (m/day) 1 1E-4 3E-5 4E-5 1 v E (kn/m²) 4 15 144 48 c (kn/m²).1 16.59 5. 4..1 3 8 58 5 4 39 4.3.35.3.3.3 SPT - 5 15 11-14 - 4.3 Settlement prediction of stone column improved soft ground In this part, the settlement of the improved soft ground is calculated by the different analytical methods and the numerical method. Bed on the comparison between these results and the meured settlement, the overall sessment of the deformation behavior of stone column improved soft ground can be concluded. 4.3.1 Analytical results By applying the different analytical methods mentioned above, the deformation of the improved zone by the stone columns can be calculated according to the 1-D problem with a load of 41.4kN/m. For the unimproved zone which is beneath the stone columns, because the soil layers have deformation modulus of larger than 1Mpa, the deformation of this zone can be predicted by using a Vietnamese Standard TCVN 936:1. The settlement determined by the different analytical methods are shown in Fig.6. 16

S e t t le m e n t ( m m ) 8 7 6 5 4 3 67.5 67.8 66.5 64.85 53.4 4.3.3 Numerical analysis by the FEM The PLAXIS 3D Foundation software h been utilized to analyze the settlement of an improved ground shown in Fig. 9. The reinforced ground can be considered to have a behavior of Mohr Coulomb model. The soil layers and its parameters are shown in Table 1. A calculated area of 144m with 5 stone columns h been analyzed in the simulation. The surcharge layer of.3m height caused the settlement of 64mm shown in Fig. 1. 1 Equilibrium Method Granular Wall Method Priebe Method (1995) Plaxis 3D s result Asaoka s result Fig. 6. Settlement predicted by the different methods. 4.3. Meured settlement at the site A system of settlement monitoring points w set up to observe the consolidation progress of treated soil shown in Fig.7 The settlement monitoring data is meured in a certain period of time and in a certain region. Therefore, the Asaoka method h been applied to determine the final settlement. Fig. 8 shows the final settlement of about 53.4mm obtained from the S1 region. Fig. 9. A 3D finite element modelling w used to predict the settlement of improved ground. Fig. 7. Settlement points layout. 53,5 53 5,5 Si (mm) 5 51,5 51 5,5 5 49,5 49,5 5 5,5 51 51,5 5 5,5 53 53,5 Si-1 (mm) Fig. 8. Final settlement derived from Asaoka method. Fig. 1. Vertical displacement of the improved ground. * Results Discussion - The different analytical methods resulted in the similar settlements with a small difference of less than 1%. - The settlement calculated by the Plaxis 3D Foundation software is very similar to the analytical result, but these results still have a difference of about 16.8% compared with the observed settlement. The main cause may be due to the fact that the actual 17

diameter of stone columns is often larger than the designed diameter due to the field compaction. From the in-situ investigation, the actual diameter of stone columns is 754mm which is 13.6% larger than the designed diameter. After the recalculation with the actual diameter of stone columns, the difference between the calculated results and the observed settlement is about 1%. 4.4 Determination of the load bearing capacity of a single stone column In this part, the load-bearing capacity of the stone columns is calculated by the different methods. Bed on the obtained results, the overall sessment of the failure mechanism well the load bearing capacity of stone columns can be concluded. 4.4.1 Analytical results Depending on the different mechanisms of failure, the ultimate load bearing capacity determined by the different analytical methods are shown in Table 3. Table 3. Ultimate load bearing capacity determined by the different methods. Method Mechanism Ultimate load bearing of failure capacity, Pult (tons) Greenwood 197 17.5 Vesic 197 Bulging 19.4 Hughes 1979 failure 16.1 Barksdale and Bachus 1983 16. Vitkar and Madhav Shear failure 1975 1.55 4.4. Static load test After finishing the test column, a static load test shown in Fig. 11 h been conducted to determine the in-situ load bearing capacity of the stone column. In the experiment, the loading process is divided into 6 levels of 33kN, 66kN, 99kN, 133kN, 165kN, 199kN which correspond to the pressures of 4.7kN/m, 81.5kN/m, 1.1kN/m, 164.kN/m, 3.7kN/m, 45.7kN/m, respectively. From the graphs in Fig. 13 and Fig. 14, the ultimate load bearing capacity of a stone column, q ult, can be obtained. Fig. 11. Static load test. Settlement (mm) Fig. 1. Relationship between load and settlement of a stone column. Fig. 13. Effects of various loadings on the relationship between settlement and time. (S6 - S1) 5 1 15 5 1 15.3.5..15.1.5 Load (tons) 5 1 15 5 3 qult q (kn/m ) Fig. 14. Ultimate load bearing capacity determined by the relationship between (S6 S1) and load. 4.4.3 Numerical analysis by the FEM The PLAXIS 3D Foundation software h been utilized to analyze the load bearing capacity of a single stone column shown in Fig. 15. Using a reinforced concrete slab with a thickness of.3m,.9m in width and length set up on the top of the stone column with a real diameter of.754m. Bed on the relationship between load and settlement of a stone column shown in Fig. 16, the load bearing capacity of 98kN can be determined. 18

Bed on the relationship between load and settlement shown in Fig. 16, if a stone column is considered a concrete pile in the load bearing capacity determination, this may result in a large difference of about 14% between the calculated result and the field test result. Fig. 15. A 3D finite element modelling w used to determine the load bearing capacity of a single stone column. Fig. 16. Relationship between load and settlement of a stone column. 5 CONCLUSION Bed on the analyses of settlement and load bearing capacity of Long An soft ground reinforced by the stone columns, the main conclusions are follows: - The different analytical methods resulted in the similar settlements, but the Aboshi s method with its simplicity is a good practical approach for the engineers. - The settlement calculated by the Plaxis 3D Foundation software is very similar to the analytical result, but these results still have a difference of about 16.8% compared with the observed settlement. The main cause may be due to the fact that the actual diameter of stone columns is often larger than the designed diameter due to the field compaction. After the recalculation with the actual diameter of stone columns, the difference between the calculated results and the observed settlement is about 1%. - The analyzing the relationship between load and displacement of a stone column to predict the load-bearing capacity by applying the Plaxis 3D Foundation software may result in a big error. There is a large difference of about 14% between the calculated result and the field test result. - Among the analytical methods, the results of Vitkar and Madhav (1975) method are quite similar with the results of the static compression test with a difference of about 6.6%. In this ce, the actual failure of a single stone column may have a mechanism of shear failure. In the calculation of the load-bearing capacity of a stone column, if the column tip penetrates into a stiff layer, the bulging failure or the shear failure often occur. REFERENCES 1) Aboshi, H., Ichimoto, E., Enoki, M. and Harada, K, (1979): The composer a method to improve characteristics of soft clay by inclusion of large diameter sand columns, Proceedings International Conference on Soil Reinforcements: Reinforced Earth and Other Techniques, Paris, Vol. 1, pp. 11-16. ) Aboshi, H. and Suematsu, N. (1985): The State of the Art on Sand Compaction Pile Method. Geotechnical Seminar on Soil Improvement Method. Nanyang Technological Institute, Singapore. 3) Asaoka, A. (1978): Observational procedure of settlement prediction, Soils and Foundations, 18 (4) (1978), 87 11 4) Barksdale and Bachus, (1983): Design and Construction of Stone Columns, Federal Highway Administration Office of Engineering and Highway Operations, National Technical Information Service, Springfield, Virginia 161 5) Dennes Bergado, M.C. Alfaro, A.S. Balubramaniam,, J.C. Chai (1994): Improvement Techniques of Soft Ground in Subsiding and Lowland Environment, ISBN-13: 97895411444, Taylor & Francis. 6) Duong Chung Nguyen (13): Study on the using of stone columns to reinforce the soft ground, Mter Thesis (in Vietnamese), 85-15. 7) Greenwood D. A and Kirsch K. (1983) Specialist Ground Treatment by Vibratory and Dynamic Method. Thom Telford. London. 8) Madhav, M. R. and P. P. Vitkar, (1978): Strip Footing on Weak Clay Stabilized with a Granular Trench or Pile, Canadian Geotechnical Journal, Vol. 15, 65-69. 9) Priebe H. J (1995): The Design of Vibro Replacement. Ground Engineering Journal. 1) Vesic, A. S., (197): Expansion of Cavities in Infinite Soil Ms, Journal of the Soil Mechanics and Foundation Engineering, ASCE, Vol. 98, No. SM3, 65-9. 11) Vietnam Ministry of Construction (1):Vietnamese Standard TCVN 936:1, Instructions for the design of foundations (in Vietnamese). 19