GAF EnergyGuard Polyiso Wall Sheathing

Similar documents
EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

R-Matte Plus-3: Insulation for the Building Envelope

GA APPLICATION OF GYPSUM SHEATHING

The better way to build TM. Installation Manual NAILBASE PANELS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

Gold Bond BRAND Gypsum Sheathing

Installation Guidelines

DuPont RainVent Batten Installation Guidelines

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

application instructions

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

WeatherSmart Air Barrier Installation Guide

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Framing Methods Structural Components

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

Envelope Highlights Mandatory Measures Prescriptive High Performance Walls 150.1

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

ENCLOSURE: SIMPLE LAYERS

TABLE OF CONTENTS HALO INSTALLATION GUIDE. THE ADVANCED RIGID INSULATION ENVELOPE PRINTED 2017

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80

SECTION THERMAL INSULATION

INSTALLATION INSTRUCTIONS

Contents. ZIP System R-Sheathing

Carpentry. The following describes the scope and sequence of instruction for Carpentry.

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

INSTALLATION INSTRUCTIONS ENERGYSHIELD AND RBOARD USE IN CANADA

HP+ Wall System X Series Technical Installation Manual

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

INSTALLATION GUIDE EPS FOAM

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

SRP-AirOutshield UV Issued:

Magnum Board Coatings

ELEVATION FOR DETAIL REFERENCE ONLY

Multi-Institutional Academic Health Science & Research Center Evansville, IN

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Project Name: Enforcement Agency: Permit Number:

Guide Specification for the OSI QUAD Window and Door Flashing System

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Residential Building Inspections

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

WE International, Inc.

for New Construction Applications

City of High Point Airport Overlay District Noise Level Reduction Design Standards

DuPont Tyvek Wall Underlay Install Guide

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

A. Source Limitations: Obtain each type of building insulation through one source.

ThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

Product and System Specifications DuPont Flashing Systems

ELEVATION FOR DETAIL REFERENCE ONLY

SECTION GYPSUM BOARD

LP SmartSide Perfection Shingle

9.36. Energy Efficiency

Knauf Makes It Easy to Insulate

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

7.0 - EXAMPLE DETAILS

ELEVATION FOR DETAIL REFERENCE ONLY

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

Chapter 14 - Air Sealing

GYPSUM BOARD AND PLASTER

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Exterior Stucco and Siding Installation

NEWS LETTER MARCH 27, 2009

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

2006 INTERNATIONAL ENERGY CONSERVATION CODE

EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Ultra Wall System. CAD Detail Sets

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

APPLICATION INSTRUCTIONS REALSIDE TM

Foil Back Gypsum Board

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Detail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office:

MAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices.

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

SECTION THERMAL INSULATION

Code Compliance Research Report CCRR-0231

Perm-A-Barrier VPS (Vapor Permeable Sheet)

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

Transcription:

From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: o Framed stud walls (exterior & interior) o Re- siding o Masonry cavity walls o Vaulted/ cathedral ceilings o Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com. Exterior Framed Stud Walls General Application Instructions: Before applying any boards, make sure to use code- accepted shear and corner bracing, such as metal strapping, let- in diagonal wood bracing or structural sheathing, such as OSB or plywood. Install EnergyGuard Polyiso Wall Sheathing boards so that the longer edge is positioned vertically with the edges resting on the middle of the stud. Make sure that the board joints are in contact with each other, with the printed side facing the exterior. Contact your local building code official for requirements on horizontal bracing. Fasten all boards using galvanized ring shank nails with a minimum 3/8 (9.5 mm) diameter heads or staples with minimum 1 (25 mm) diameter plastic caps. Fasteners must be long enough to penetrate the substrate at least 3/4 (19mm). Fasten EnergyGuard Polyiso Wall Sheathing boards 12 (305 mm) o.c. around the perimeter and 16 (406 mm) o.c. in the field or as required by local codes. Do not overdrive the fasteners.

Seal all exterior openings and penetrations with all- weather sealant, such as silicone caulk, prior to taping. Make sure all areas are clean prior to sealing and taping to ensure proper adhesion. Center and apply 3 (76 mm) wide foil flashing tape to all board joints, penetrations, window flanges and door edges. Apply tape and sealant in accordance with the manufacturer s application instructions. Always cover EnergyGuard Polyiso Wall Sheathing with a code- approved exterior cladding system, such as vinyl siding, wood siding, aluminum siding, brick, stucco, cover board, etc. Cladding should be installed in accordance with the cladding system manufacturer s application instructions. In areas of high humidity or as required by local code, install a vapor retarder. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.

From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: Framed stud walls (exterior & interior) Re- siding Masonry cavity walls Vaulted/ cathedral ceilings Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com. Re- Siding General Application Instructions: Before applying any EnergyGuard Polyiso Wall Sheathing boards, make sure to consult the siding manufacturer for specific recommendations and application instructions. Existing siding should be moisture free and in relatively good condition. Replace or repair any rotted trim, siding or wood. Remove any obstructions, such as shutter or downspouts, prior to installing the new insulation board. Install EnergyGuard Polyiso Wall Sheathing boards over the existing siding so that the longer edge is positioned vertically, with the edges resting on the middle of the stud. Make sure the board joints are in contact with each other, with the printed side facing the exterior. Fasten all boards using galvanized ring shank nails with a minimum 3/8 (9.5 mm) diameter heads or staples with minimum 1 (25 mm) diameter plastic caps. Fasteners must be long enough to penetrate the studs at least 3/4 (19mm). Fasten EnergyGuard Polyiso Wall Sheathing boards 12 (305 mm) o.c. around the perimeter and 16 (406 mm) o.c. in the field or as required by local codes. Do not overdrive the fasteners.

Seal all exterior openings and penetrations with all- weather sealant, such as silicone caulk, prior to taping. Make sure all areas are clean prior to sealing and taping to ensure proper adhesion. Center and apply 3 (76 mm) wide foil flashing tape to all board joints, penetrations, window flanges and door edges. Apply tape and sealant in accordance with the manufacturer s application instructions. Always cover EnergyGuard Polyiso Wall Sheathing with a code- approved exterior cladding system such as vinyl siding, wood siding, aluminum siding, brick, stucco, cover board, etc. The new cladding should be installed in accordance with the cladding system manufacturer s application instructions. Fasteners for the exterior cladding should be long enough to penetrate through all the material layers into the structural substrate as required by the cladding manufacturer. In areas of high humidity or as required by local code, install a vapor retarder. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.

From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: o Framed stud walls (exterior & interior) o Re- siding o Masonry cavity walls o Vaulted/ cathedral ceilings o Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com. Masonry Cavity Walls General Application Instructions: Install EnergyGuard Polyiso Wall Sheathing boards between the concrete wall and the exterior masonry system so that the longer edge is positioned horizontally against the inner concrete wall. Make sure the board joints are in contact with each other, with the printed side facing the exterior. Fasten all boards using appropriate masonry mechanical fasteners or construction- grade adhesive following the adhesive manufacturer s instructions. Fasteners must be long enough to penetrate the concrete wall at least 3/4 (19mm). Do not overdrive the fasteners. Fasten EnergyGuard Polyiso Wall Sheathing boards 12 (305 mm) o.c. around the perimeter and 16 (406 mm) o.c. in the field or as required by local codes. Install masonry wall ties between board joints. Seal all exterior openings and penetrations with all- weather sealant, such as silicone caulk prior to taping.

Make sure all areas are clean prior to sealing and taping to ensure proper adhesion. Center and apply 3 (76 mm) wide foil flashing tape to all board joints, penetrations, window flanges and door edges. Apply tape and sealant in accordance with the manufacturer s application instructions. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. 2. EnergyGuard Polyiso Wall Sheathing boards can be applied to most oil- base waterproofing coatings. Refer to coating manufacturer s instructions. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.

From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: o Framed stud walls (exterior & interior) o Re- siding o Masonry cavity walls o Vaulted/ cathedral ceilings o Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com. Interior Framed Stud Walls General Application Instructions: If batt insulation is to be installed between studs, install it prior to the application of the EnergyGuard Polyiso Wall Sheathing boards. Install EnergyGuard Polyiso Wall Sheathing boards to the framed stud interior wall so that the longer edge is positioned vertically, with the edges resting on the middle of the interior stud. Make sure the board joints are in contact with each other, with the printed side facing the interior. Fasten all boards using galvanized ring shank nails with a minimum 3/8 (9.5 mm) diameter heads or staples with minimum 1 (25 mm) diameter plastic caps. Fasteners must be long enough to penetrate the substrate at least 3/4 (19mm). Fasten EnergyGuard Polyiso Wall Sheathing boards 12 (305 mm) o.c. around the perimeter and 16 (406 mm) o.c. in the field or as required by local codes. Do not overdrive the fasteners. Seal all interior openings and penetrations with all- weather sealant, such as silicone caulk, prior to taping. Make sure that all areas are clean prior to sealing and taping to ensure proper adhesion.

Center and apply 3 (76 mm) wide foil flashing tape to all board joints, penetrations, window flanges and door edges. Apply tape and sealant in accordance with the manufacturer s application instructions. Gypsum boards should be installed in accordance with the gypsum board manufacturer s application instructions. In areas of high humidity or as required by local code, install a vapor retarder. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.

From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: o Framed stud walls (exterior & interior) o Re- siding o Masonry cavity walls o Vaulted/cathedral ceilings o Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com. Interior Basement Walls General Application Instructions: Install EnergyGuard Polyiso Wall Sheathing boards to the interior side of the basement masonry wall so that the longer edge is positioned vertically against the field of the wall. Make sure the board joints are in contact with each other, with the printed side facing the interior. Installation with Wood Furring Fasten all boards to wall using construction- grade adhesive following the adhesive manufacturer s instructions. Install wood furring strips a maximum 16 (406mm) o.c. vertically over the EnergyGuard Polyiso Wall Sheathing boards with appropriate masonry mechanical fasteners. Be sure to install furring strips over the vertical joints of the insulation boards. Fasteners must be long enough to penetrate through the furring strip into the concrete wall at least 3/4 (19mm). Do not overdrive the fasteners. Installation with Conventional Stud Wall

Spot fasten all EnergyGuard Polyiso Wall Sheathing boards to the masonry basement wall using construction- grade adhesive following the adhesive manufacturer s instructions. Construct a conventional stud wall that firmly applies pressure to the installed EnergyGuard Polyiso Wall Sheathing boards. Install batt insulation in between studs as required by local codes. Always cover EnergyGuard Polyiso Wall Sheathing boards with a code- approved interior cladding system such as ½ (13mm) gypsum board. Install gypsum boards in accordance with the gypsum board manufacturer s application instructions. In areas of high humidity or as required by local code, install a vapor retarder. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. 2. EnergyGuard Polyiso Wall Sheathing boards can be applied to most oil- base waterproofing coatings. Refer to coating manufacturer s instructions. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.

rom: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: Framed stud walls (exterior & interior) Re- siding Masonry cavity walls Vaulted/ cathedral ceilings Interior basement walls The following are general application instructions. Be sure to review complete instructions at www.gaf.com Vaulted/Cathedral Ceilings General Application Instructions: Cut the EnergyGuard Polyiso Wall Sheathing boards to fit snugly between the roof rafters. Install the boards between the bottom sides of the roof rafters making sure the boards stop flush. Run the boards continuously without gaps the entire length of the vaulted ceiling, starting from the top or bottom. The thickness of the EnergyGuard Polyiso Wall Sheathing boards should be such so that when they are installed flush with the bottom of the roof rafters, there is a continuous air space between the top of the Polyiso boards and the bottom of the roof deck. This gap is to provide enough net- free continuous air space from the soffit vents up to the ridge vent so it does not restrict air flow. For proper ventilation requirements, refer to local building code or roofing manufacturer s guidelines. Polyiso board joints are to be in contact with each other, with the printed side facing the interior.

Seal all interior openings and penetrations with all- weather sealant, such as silicone caulk, prior to taping. Make sure all areas are clean prior to sealing and taping to ensure proper adhesion. Center and apply 3 (76 mm) wide foil flashing tape to all board joints, penetrations and skylight flanges. Apply tape and sealant in accordance with the manufacturer s application instructions. Always cover EnergyGuard Polyiso Wall Sheathing with a code- approved interior cladding system, such as ½ (13mm) gypsum board. The gypsum boards or other interior cladding system should be installed in accordance with the appropriate manufacturer s application instructions. In areas of high humidity or as required by local code, install a vapor retarder. NOTE: 1. Contact your local building code official for requirements on fire barriers. Do not leave boards exposed to the weather or near high heat sources. For other types of application or further information, contact our Technical Services at 800- ROOF- 411 (800-766- 3411) or www.gaf.com.