PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Similar documents
PD6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER

PD662 LOOP-POWERED METER

YPP6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER

PD662 LOOP-POWERED METER Instruction Manual

PD662 Loop-Powered Meter Instruction Manual

PD6700 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD663 EXPLOSION-PROOF LOOP-POWERED METER

PD663 EXPLOSION-PROOF LOOP-POWERED METER

PD663 EXPLOSION-PROOF LOOP-POWERED METER

Loop Powered Indicator

Sabre P Model PD603 Process Meter Instruction Manual

PD663 EXPLOSION-PROOF LOOP-POWERED METER

SABRE P MODEL PD603 PROCESS METER Instruction Manual

PD6801 EXPLOSION-PROOF Loop-Powered Feet & Inches Level Meter

Cla-Val X145 Loop-Powered Rate/Totalizer Instruction Manual

Supplemental Instruction Manual

PD8 Series ProtEX-MAX Supplemental Instruction Manual

SABRE T MODEL PD743 TEMPERATURE METER Instruction Manual

YPP6801 EXPLOSION-PROOF FEET & INCHES LEVEL METER

PD683 & PD688 LOOP-POWERED METERS

HDI 2200 Choke Position Indicator

Model PD656 Large Display Process Meter with Rate/Totalizer/Batch Control Features Instruction Manual

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

PD683 & PD688 LOOP-POWERED METERS Instruction Manual

Sby SR Instruments, Inc.

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Precision Automatic Vacuum Control (PAVC+)

PIH PIH. Pressure-to-Current Transmitter. Field Mount. Field Mount Pressure-to-Current Transmitter. January A

FCT FCT [UB] [UB] FCT [UB] Signal Converter/Isolator. Signal Converter/Isolator. Page 1. April B. The Interface Solution Experts

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

OptoLum MegaLine RGBW Luminaire

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment.

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

Model HH Signal-Conditioner / Indicator

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

2-Position T1/HDSL Environmental Mounting Assembly Model EM02-0xx

VN Series Floor Scale Instruction Manual

Operating Instructions April 2010 milltronics WD600

Read and understand this manual for safely usage.

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

To Contact PS DOORS:

Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

Table of contents. 1. Introduction

DS-520 Digital Indicator Operation Manual 73366

MD Power Supply -48Vdc +Bias Tee

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Model: LoLander Series Truck Scale Model: LL FT Model: LL FT Installation, Set-Up and Operation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Wash Down Duty Non-Contact Sensor

RSD250 Unwind Dancer Package WEB CONTROL PRODUCTS FORM NO. L B User Manual. MTY (81)

Agilent 16034E Test Fixture

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Installation and Operation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

SENTRAN. Low Profile Load Cell. For more information call

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

PD6830 EXPLOSION-PROOF PULSE INPUT RATE/TOTALIZER

Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

Bravo Platform Unpacking Guide

Installation Manual. Omnicell. Model: 9101 FB by Fairbanks Scales, Inc. Revision 2 03/16 All rights reserved

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H

INSTALLATION INSTRUCTIONS

Engineering Specifications

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

Read and understand this manual for safely usage.

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

Agilent 16047D Test Fixture

MODEL CA-72 SERIES ACCELERATION TRANSDUCER INSTRUCTION MANUAL

Agilent 16048D Test Leads

Signal Follower Card. Instruction Manual Model C

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

92831 TEL: (714) FAX:

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

RHE3 Dock Leveler Installation Manual

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

CFL Series User Manual

Mechanical Post Lift. Owner s Manual

92831 TEL: (714) FAX:

Installation, Operation and Maintenance Instructions 3.19 [81.0] 0.43 [11.0] 0.94 [23.9].29 THRU 0.43 [11.0] 1.42 [36.0] 4.80 [121.8] 1.89 [47.

Installation, Operation & Maintenance Manual

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SWM-1 Loudspeaker Wall Mount Device. P/N: Rev 1

General Safety Information

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

HT829 Humidity Transmitter HT839 Humidity and Temperature Transmitter Installation and Operating Instructions

Transcription:

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure Flanges for Wall or Pipe Mounting Easy Calibration and Installation Operates from -40 to 75 C PRECISION DIGITAL CORPORATION 89 October Hill Road Holliston MA 01746 USA Tel (800) 343-1001 Fax (508) 655-8990 www.predig.com

Disclaimer The information contained in this document is subject to change without notice. Precision Digital makes no representations or warranties with respect to the contents hereof; and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose.! CAUTION: Read complete instructions prior to installation and operation of the meter. WARNING: Risk of electric shock or personal injury. WARNINGS This product is not recommended for life support applications or applications where malfunctioning could result in personal injury or property loss. Anyone using this product for such applications does so at his/her own risk. Precision Digital Corporation shall not be held liable for damages resulting from such improper use. Failure to follow installation guidelines could result in death or serious injury. Make sure only qualified personnel perform the installation. Limited Warranty Precision Digital Corporation warrants this product against defects in material or workmanship for the specified period under Specifications from the date of shipment from the factory. Precision Digital s liability under this limited warranty shall not exceed the purchase value, repair, or replacement of the defective unit. Registered Trademarks All trademarks mentioned in this document are the property of their respective owners. 2013 Precision Digital Corporation. All rights reserved. www.predig.com 2

INTRODUCTION The Vantageview PD6770 is a rugged, loop-powered meter with 1" display digits. The plastic NEMA 4X and IP65 field mountable enclosure is designed for demanding applications in the harshest environmental conditions. The meter derives all of its power from the 4-20 ma loop with a small 1 volt drop for easy installation in almost any system. It is programmed using four easy to access front-mounted control dials with no complex or difficult to read programming menus necessary for setup. The numeric display will read from -1999 to 1999 over a 2000 count user adjustable scaling span. The backlight option lets you see the display under any lighting condition and is powered from the 4-20 ma loop with no additional power supply required. The enclosure is provided with two threaded conduit holes and integrated pipe or wall mounting slotted flanges. ORDERING INFORMATION Model PD6770-0L0 PD6770-0K0 Description Loop-Powered Process Meter Loop-Powered Process Meter with Backlight Accessories Model PDAPLUG75P PDA6846 PDA6846-SS Description 3/4" NPT Plastic Conduit Plug Pipe Mounting Kit. Includes zinc-plated u-bolt for 2" pipe, (2) washers, and (2) nuts. Pipe Mounting Kit. Includes stainless steel u- bolt for 2" pipe, (2) washers, and (2) nuts. 3

Table of Contents INTRODUCTION ---------------------------------------------------------------------- 3 ORDERING INFORMATION ------------------------------------------------------- 3 SPECIFICATIONS -------------------------------------------------------------------- 5 General ------------------------------------------------------------------------------------------- 5 Input ----------------------------------------------------------------------------------------------- 6 SAFETY INFORMATION -------------------------------------------------------------------- 7 INSTALLATION ----------------------------------------------------------------------- 8 Unpacking --------------------------------------------------------------------------------------- 8 Conduit/Stopping Plug ---------------------------------------------------------------------- 8 Mounting ----------------------------------------------------------------------------------------- 8 Connections ------------------------------------------------------------------------------------ 9 Connections & Wiring Diagrams... 10 SETUP ---------------------------------------------------------------------------------- 11 Scaling Controls and Display ----------------------------------------------------------- 11 Setting Up the Meter ----------------------------------------------------------------------- 12 Calibrating the Meter... 12 Setting the Decimal Point... 12 Factory Defaults & User Settings ----------------------------------------------------- 13 TROUBLESHOOTING ------------------------------------------------------------- 14 Troubleshooting Tips ---------------------------------------------------------------------- 14 MOUNTING DIMENSIONS -------------------------------------------------------- 15 Table of Figures Figure 1. PD6770 Connectors... 9 Figure 2. PD6770 Input Connections without Backlight... 10 Figure 3. PD6770 Input Connections with Loop-Powered Backlight... 10 Figure 4. Enclosure Dimensions Front View... 15 Figure 5. Enclosure Dimensions Side Cross Section View... 15 4

SPECIFICATIONS Except where noted all specifications apply to operation at +25 C. General DISPLAY DISPLAY UPDATE RATE OVERRANGE PROGRAMMING METHOD RECALIBRATION NORMAL MODE REJECTION 3 ½ digit LCD 1" (25.4 mm); -1999 to 1999 2.5 Updates/Second Display reads 1 on the left most digit Four front mounted rotary control dials accessed when the cover is removed. Recalibration is recommended at least every 12 months. 60 db rejection ratio ENVIRONMENTAL Operating temperature range: -40 to 75 C Storage temperature range: -40 to 75 C Relative humidity: 0 to 90% non-condensing CONNECTIONS ENCLOSURE MOUNTING OVERALL DIMENSIONS WEIGHT WARRANTY Screw terminals accept 12 to 22 AWG wire NEMA 4X, IP65 plastic field enclosure. Color: grey. Three ¾" NPT threaded conduit openings. One ¾" NPT plastic conduit plug, with 1.29" wrenching flats and a screwdriver slot, is included. May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting. See Mounting Dimensions on page 15. 5.67" x 5.25" x 4.18" (W x H x D) (144 mm x 133 mm x 106 mm) 1.65 lbs (26.4 oz, 0.75 kg) 3 years parts and labor 5

Input ACCURACY TEMPERATURE DRIFT DECIMAL POINT CALIBRATION RANGE MAXIMUM VOLTAGE DROP EQUIVALENT RESISTANCE INPUT OVERLOAD ±0.1% of full span ±1 count 150 PPM/ C from -40 to 75 C ambient User selectable decimal point 4 ma input: -1000 to +1000; 20 ma between 20 and 2000 counts greater than 4 ma display. Two point linear display span. Without Backlight With Loop-Powered Backlight 1 VDC @ 20 ma 4 VDC @ 20 ma 50 Ω @ 20 ma 200 Ω @ 20 ma Over current protection to 2 A max. 6

SAFETY INFORMATION WARNINGS Read complete instructions prior to installation and operation of the meter. Installation and service should be performed only by trained service personnel. Service requiring replacement of internal components must be performed at the factory. Disconnect from supply before opening enclosure. Keep cover tight while circuits are alive. If the meter is installed in a high voltage environment and a fault or installation error occurs, high voltage may be present on any lead 7

INSTALLATION All controls and wiring connectors are accessed by opening the enclosure. To access electrical connectors, remove the 2 captive screws and remove the display module from the enclosure. WARNING Unpacking Hazardous voltages may exist within enclosure. Installation and service should be performed only by trained service personnel. Remove the meter and conduit plug from box. Inspect the packaging and contents for damage. Report damages, if any, to the carrier. If any part is missing or the meter malfunctions, please contact your supplier or the factory for assistance. Conduit/Stopping Plug The PD6770 includes three ¾" NPT threaded conduit openings and one IP68 rated ¾" NPT plastic conduit plug. The conduit/stopping plug included has 1.29" wrenching flats and a screwdriver slot. Mounting The PD6770 has two slotted mounting flanges that may be used for pipe mounting or wall mounting. Alternatively, the unit may be supported by the conduit using the conduit holes provided. Refer to Mounting Dimensions, page 15 for details. WARNING Do not attempt to loosen or remove flange bolts while the meter is in service. 8

Connections WARNINGS Static electricity can damage sensitive components. Observe safe handling precautions for static-sensitive components. Use proper grounding procedures/codes. If the meter is installed in a high voltage environment and a fault or installation error occurs, high voltage may be present on any lead or terminal. To access the connectors, remove the enclosure cover and unscrew the two captive screws that fasten the display module. Remove the display module. Signal connections are made to a three-terminal connector on the rear of the display module. S+ 4-20 ma signal input positive terminal connection S- 4-20 ma signal return/negative terminal connection B- 4-20 ma signal return/negative terminal when using the installed loop powered backlight option. Refer to Figure 1 for terminal positions. WARNING Observe all safety regulations. Electrical wiring should be performed in accordance with all agency requirements and applicable national, state, and local codes to prevent damage to the meter and ensure personnel safety. Figure 1. PD6770 Connectors 9

Connections & Wiring Diagrams Signal connections are made to a three-terminal connector mounted on the rear of the display module. The enclosure also provides one internal and one external earth grounding screw. The 4-20 ma input with no backlight has a maximum voltage drop of 1 V and is wired as shown in Figure 2. The loop-powered backlight configuration requires a total maximum voltage drop of 4 V. The backlight option is recommended for dim lighting conditions and is enabled when wired as shown in Figure 3. Figure 2. PD6770 Input Connections without Backlight Figure 3. PD6770 Input Connections with Loop-Powered Backlight 10

SETUP Overview Setup is done using four rotary control dials located on the front of the display module that are accessed when the meter cover is removed. Setup is performed using a 4-20 ma signal source and scaling the 4 and 20 ma readings using the control dials. Scaling Controls and Display Control LO LO FINE HI HI FINE Description 4 ma display adjust. 4 ma precision display adjust. 20 ma display adjust. 20 ma precision display adjust. 11

Setting Up the Meter Calibrating the Meter The meter is provided factory calibrated to display -50.0 at 4 ma and 150.0 at 20 ma. HI and LO coarse and fine controls are labeled on the front of the display. Use the HI and LO controls for large range changes during calibration and the HI FINE and LO FINE controls for precision changes. Apply a 4 ma signal and adjust the LO controls to display the desired reading. Apply a signal between 16 and 20 ma and adjust the HI controls to display the desired reading. Complete the calibration procedure by making minor adjustments to the LO and HI controls as necessary. Minimum & Maximum Input Span A minimum input span of 20 counts is required between a 4 ma and 20 ma input. A maximum input span of 2000 counts may be setup between a 4 ma and 20 ma input. The meter will not properly calibrate or display if these minimum and maximum span ranges are not maintained during scaling. Setting the Decimal Point Decimal point may be set using a three position jumper on the rear of the display module. To access the connectors, unscrew the two captive screws that fasten the display module. Remove the display module and place the jumper on the desired pins as indicated on the board for decimal point locations of D.DDD, DD.DD, DDD.D, or remove it if no decimal point is desired. 12

Factory Defaults & User Settings The following table shows the factory setting for most of the programmable parameters on the meter. Next to the factory setting, the user may record the new setting for the particular application. Model: Parameter Decimal point S/N: Date: Default User Setting Setting 1 place Calibration Settings Input 1 4.00 ma Display 1-50.0 Input 2 20.00 ma Display 2 150.0 13

TROUBLESHOOTING The rugged design and the user-friendly interface of the meter should make it unusual for the installer or operator to refer to this section of the manual. If the meter is not working as expected, refer to the recommendations below. Troubleshooting Tips Symptom No display Rate display unsteady during calibration Meter displays 1 on the left most digit location Display is faded If the display locks up or the meter does not respond at all Backlight does not appear Other symptoms not described above Check/Action Check input signal connections. Adjust LO FINE or HI FINE controls to fine-tune the display. Check signal level is not over range. Dial down the HI control and recalibrate at 20 ma. Check input signal is not under 1 ma. Perform hard reset by shorting S+ and S- terminals. Verify backlight is installed. Check signal connections are as shown in Figure 3 on page 10. Call Technical Support for assistance. 14

3.35 85.1 PD6770 Loop-Powered Process Meter MOUNTING DIMENSIONS 2.25 57.2 All units: inches [mm] 0.33 8.3 3.35 85.1 0.33 8.3 2.25 57.2 5.67 144.0 5.67 144.0 5.25 133.3 5.25 133.3 Figure 4. Enclosure Dimensions Front View Ø 3.34 84.9 Ø 3.34 84.9 4.18 106.1 4.18 106.1 Figure 5. Enclosure Dimensions Side Cross Section View Note: The supplied conduit plug may extend up to 0.21 in [5.3 mm] from the conduit opening when installed. 15

How to Contact Precision Digital For Technical Support: Call: (800) 610-5239 or (508) 655-7300 Fax: (508) 655-8990 Email: support@predig.com For Sales Support: Call: (800) 343-1001 or (508) 655-7300 Fax: (508) 655-8990 Email: sales@predig.com For the latest version of this manual please visit: www.predig.com LIM6770_A 10/13