Reading, Understanding, and Following NERC Standards

Similar documents
Implementation Plan Project Operations Personnel Training

Implementation Plan for IRO Reliability Coordination Facilities Prerequisite Approvals Adoption of IRO-001-2, IRO-010-0, COM-001-2

DESCRIPTION OF NERC AND NPCC STANDARD & CRITERIA DOCUMENTS

Performance Standards Issues. Donald Lamontagne Principal Engineer Arizona Public Service

Proposed Revisions to the Applicability of NERC Reliability Standards NERC Standards Applicability to Dispersed Generation Resources

Proposed Revisions to the Applicability of NERC Reliability Standards NERC Standards Applicability to Dispersed Generation Resources

Functional Entity Roles and Responsibilities

4.1 Violation Reporting Remedial Action Directives Mitigation Plans Internal Training Self Assessments...

Mapping Document. Project Phase 2 of System Protection Coordination. Revisions or Retirements to Already Approved Standards

August 1, ReliabilityFirst Compliance Contacts ReliabilityFirst Compliance Program Update Letter August Update

Standard Development Timeline

NYISO Reliability Compliance Status Report for NYSRC RCMS Program Year: 2008

Appendix 5B Statement of Compliance Registry Criteria Revision 5.2 Effective: October 15, 2015

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

Project Consideration of Commission Directives in Order No. 693

NYSRC RELIABILITY RULE/NERC STANDARD CROSS-REFERENCE

Standard EOP System Restoration from Blackstart Resources

Brent Read Compliance Engineer - Enforcement. NERC PER Standards January 29, 2013 Compliance User Group

NERC-led Review Panel Decision on the Request by Orange Grove Energy, L.P.

Western Electricity Coordinating Council WECC Glossary of Terms and Naming Conventions Updated: December 6, 2016

Technical Justification Resource Document Project Generator Requirements at the Transmission Interface Updated July 16, 2012

Appendix 5B. Statement of Compliance Registry Criteria

Mapping Document for FAC-010-3

Standard EOP System Restoration from Blackstart Resources

Load Shed Philosophy

Implementation Plan IRO Reliability Coordination Current Day Operations

N ORTH A MERICAN E LECTRIC R ELIABILITY C OUNCIL

Risk-Based Registration Technical Justification. August 26, 2014

Project Revisions to TOP and IRO Reliability Standards Mapping Document Updated December 2014

NERC Standards Report, Status and Timetable for Addressing Regulatory Directives, and Periodic Review of Reliability Standards Docket No.

A. Introduction. B. Requirements and Measures

FERC Directives in Order 693 Addressed in IROL Implementation Plan

Security Guideline for the Electricity Sector: Identifying Critical Assets

DRAFT Reliability Standards Development Plan. June 15, 2016

September 12, 2016 VIA ELECTRONIC FILING

Appendix A3: Northeast Power Coordinating Council (NPCC) 2018 CMEP Implementation Plan

Project Revision of TOP/IRO Reliability Standards Resolution of Issues and Directives

PRC and EOP Effective 10/1/13

RCR-35 Reliability Coordinator Reliability Plan for the SaskPower Subregion of the Midwest Reliability Organization

Standard IRO a Reliability Coordination Current Day Operations

NERC Reliability Functional Model

Standards Authorization Request Form

Transfer Capability Methodology. for the Near-Term. Transmission Planning Horizon

Standard Development Timeline

TOP TOP TOP 003 3

Standard Development Timeline

Standard EOP Loss of Control Center Functionality

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. NORTH AMERICAN ELECTRIC ) Docket No. RR06-1- RELIABILITY CORPORATION )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION. NORTH AMERICAN ELECTRIC ) Docket No. RR06-1- RELIABILITY CORPORATION )

DRAFT Reliability Standard Audit Worksheet 1

A. Introduction Balancing Authority Reliability Coordinator Transmission Operator. 5. Effective Date:

Standard IRO Reliability Coordination Monitoring and Analysis

Brent Read Compliance Engineer - Enforcement. Root Cause Analysis for Commonly Violated Requirements October 23, 2013 Compliance User Group

Comparison of IV.A.M2 and IV.A.M3 to EOP-005-1

Québec Reliability Standards Compliance Monitoring and Enforcement Program Implementation Plan Annual Implementation Plan

PJM TO/TOP Matrix of Shared or Assigned Tasks

FAC Facility Interconnection Requirements

Unofficial Comment Form Functional Model Advisory Group Revisions to the Functional Model and Functional Model Technical Document

NORMES DE FIABILITÉ DE LA NERC - IRO (VERSION ANGLAISE)

Project : Generator Requirements at the Transmission Interface Background Resource Document

Proposed Definitions for the NERC Glossary of Terms Project : Emergency Operations

PJM TO/TOP Matrix of Shared or Assigned Tasks

RELIABILITY PLAN for the SERC Southeastern Subregion Reliability Coordinator July 14, 2016

Project System Operating Limits

Standard IRO Reliability Coordination Monitoring and Analysis

NERC Compliance Process Bulletin # Update to 2010 CMEP Implementation Plan

CIP Cyber Security Security Management Controls

Operating Procedure PURPOSE... 1

July 15 July 31. August First ballot September 1 10, Drafting Team considers comments and makes any revisions indicated

Glossary of Terms Used in Reliability Standards. Preliminary Draft Version 0 Reliability Standards September 1, 2004

2013 SPP RE Annual CMEP Implementation Plan

Statement of Compliance Registry Criteria (Revision 3.1)

Standards Authorization Request Form

Standard IRO Reliability Coordination Monitoring and Analysis

Standard Development Timeline

Review of Standards Becoming Enforceable in 2014

Unofficial Comment Form Functional Model Advisory Group Revisions to the Functional Model and Functional Model Technical Document

DRAFT Reliability Standard Audit Worksheet 1

Standard EOP Load Shedding Plans

Standard EOP Capacity and Energy Emergencies

Toward Ensuring Reliability: Reliability Performance Metrics. A NERC Staff White Paper

EOP Geomagnetic Disturbance Operations

by the Transmission Planner or Planning Coordinator.

Standard PRC-004-2a Analysis and Mitigation of Transmission and Generation Protection System Misoperations

MACD - Ontario Reliability Compliance Program Reliability Standards Compliance Monitoring Plan

Standard IRO Reliability Coordin ation Res pons ibilities and Authorities

Standard Development Timeline

Unofficial Comment Form Project PER Revisions

FAC Facility Interconnection Requirements

PRC Under Voltage Load Shedding

Five-Year Review Template Updated July 29, 2013

WECC-0111 TOP-007-WECC-1a System Operating Limits Retire or Modify Supporting Narrative and Crosswalk to Retire

NERC Glossary Definitions: System Operating Limit and SOL Exceedance Rationale

Proposed Revisions to the Applicability of NERC Reliability Standards NERC Standards Applicability to Dispersed Generation Resources

GUIDE. Part 11.1: Applicability Criteria for Compliance with NERC Reliability Standards and NPCC Criteria PUBLIC

Reliability Standards Development Plan

ERO Com plia nce Monitoring and Enforcement Program

Transcription:

Reading, Understanding, and Following NERC Standards September 15, 2011 Greg Sorenson, PE Senior Compliance Engineer gsorenson.re@spp.org 501.688.1713

Outline Philosophy behind standards Reading standards Following standards Measuring performance Types of standards Additional resources 3

References NERC Reliability Standards for the Bulk Electric Systems of North America NERC Standard Process Manual 4

NERC s Philosophy Behind Standards Reliability Principles addressed Planned and operated in a coordinated manner Within frequency and voltage limits while balancing Real and Reactive Power Information necessary for planning and operations made available Plans for emergencies and restorations effective Facilities properly maintained Personnel trained, qualified, and have authority to operate Reliability assessed, monitored, and maintained Protection from physical and cyber attacks 5

NERC s Philosophy Behind Standards Provide Adequate Level of Reliability Bulk Electric System: Is within limits during normal conditions Performs acceptably after contingencies Limits impact and scope of instability and cascading outages Facilities protected from damage Integrity can be restored if lost Has ability to supply power and energy to all electricity customers at all times, including likely unscheduled outages 6

Key parts of standards Purpose: Standard s goal Applicability: Which parties the standard applies to Requirements: What the parties are responsible for Measures: How to assess if the requirements have been met Compliance: Additional notes on method (audit, selfcertification) and data requirements NERC s annual Actively Monitored List takes precedence Appendices: Additional important information 7

NERC Defined Terms Capitalized terms and acronyms are in the Reliability Standards Glossary NERC.com > Standards > Reliability Standards (on left) System Operating Limit (SOL) (Numerous) Capacity Benefit Margin (MOD 004) Capacity Emergency (EOP 001, EOP 002) Emergency (EOP, TOP) Protection System (PRC 005) 8

Purpose Describes why the standard is written FAC 009 1 Purpose: To ensure that Facility Ratings used in the reliable planning and operation of the Bulk Electric System (BES) are determined based on an established methodology or methodologies. TOP 002 2a Purpose: Current operations plans and procedures are essential to being prepared for reliable operations, including response for unplanned events. 9

Requirements Specify who is responsible for what activities Pay attention to all parts! BAL 006 1 R1. Each Balancing Authority shall calculate and record hourly Inadvertent Interchange. EOP 001 1 R2. Each TOP and BA shall R2.2. Develop, maintain, and implement a set of plans to mitigate operating emergencies on the transmission system. FAC 001 0 R1. The TO shall document, maintain, and publish facility connection requirements 10

Requirements IRO 004 R4. Each TOP, BA, TO, GO, GOP, and LSE in the RC Area shall provide information required for system studies, such as critical facility status, Load, generation, operating reserve projections, and known Interchange Transactions. This information shall be available by 1200 Central Standard Time for the Eastern Interconnection and 1200 Pacific Standard Time for the Western Interconnection. 11

Requirements PRC 004 1, R1. The Transmission Owner and any Distribution Provider that owns a transmission Protection System shall each analyze its transmission Protection System Misoperations and shall develop and implement a Corrective Action Plan to avoid future Misoperations of a similar nature according to the Regional Reliability Organization s procedures developed for Reliability Standard PRC 003 Requirement 1. 12

Requirements FAC 009 1 R2. The TO and GO shall each provide Facility Ratings for its solely and jointly owned Facilities that are existing Facilities, new Facilities, modifications to existing Facilities and re ratings of existing Facilities to its associated RC, PA, TP, and TOP as scheduled by such requesting entities. 13

Measures Provides guidance on how to demonstrate compliance. PRC 004 1 M1. The TO, and any DP that owns a transmission Protection System shall each have evidence it analyzed its Protection System Misoperations and developed and implemented Corrective Action Plans to avoid future Misoperations of a similar nature according to the Regional Reliability Organization procedures developed for PRC 003 R1. 14

Measures PRC 001 1 M1. Each Generator Operator and Transmission Operator shall have and provide upon request evidence that could include but is not limited to, revised fault analysis study, letters of agreement on settings, notifications of changes, or other equivalent evidence that will be used to confirm that there was coordination of new protective systems or changes as noted in Requirements 3, 3.1, and 3.2. 15

Measures EOP 002 2.1. M2. If an RC or BA implements its Capacity and Energy Emergency plan, that entity shall have and provide upon request evidence that could include but is not limited to, operator logs, voice recordings or transcripts of voice recordings, electronic communications, computer printouts or other equivalent evidence that will be used to determine if the actions it took to relieve emergency conditions were in conformance with its Capacity and Energy Emergency Plan. 16

Measures TOP 002 2a M1. Each Balancing Authority and Transmission Operator shall have and provide upon request evidence that could include, but is not limited to, documented planning procedures, copies of current day plans, copies of seasonal operations plans, or other equivalent evidence that will be used to confirm that it maintained a set of current plans. (Requirement 1 Part 1). 17

Reliability Standard Types Technical Performance Continuous Event driven Preparedness Organization Certification Some standards may fit into more than one type or have requirements that fit into more than one type 18

Technical Standards Related to provision, testing, analysis, maintenance, or state of bulk power systems. Examples: PRC 005 (Relay maintenance) FAC 001 (Interconnection requirements) FAC 008 (Ratings methodology) FAC 009 (Facility ratings) BAL 005 R17 (Meter accuracy) COM 001 (Telecommunications) Failure to follow would affect planning and real time operations/jeopardize normal system responses test, establish, design, maintenance, analysis 19

Technical Standards COM 001 1.1, R2. Each RC, TOP, and BA shall manage, alarm, test and/or actively monitor vital telecommunications facilities. Special attention shall be given to emergency telecommunications facilities and equipment not used for routine communications. FAC 009 1, R1. The TO and GO shall each establish Facility Ratings for its solely and jointly owned Facilities that are consistent with the associated Facility Ratings Methodology. 20

Performance Standards Related to entities actions providing for or impacting reliability. Examples: BAL 001 1 (Control Performance Standard) BAL 002 0 (Disturbance Control Performance) COM 002 (directives, staffing) VAR 002 1 (Generator Operation for Voltage) Measures results of these actions Measures quality of performance of these actions implement, coordinate, provide, submit, operate 21

Performance Standards Unless otherwise noted, no failures are allowed COM 002, R2. Each RC, TOP, and BA shall issue directives in a clear, concise, and definitive manner; shall ensure the recipient of the directive repeats the information back correctly; and shall acknowledge the response as correct or repeat the original statement to resolve any misunderstandings. BAL 002 0, R4. A BA or RSG shall meet the Disturbance Recovery Criterion within the Disturbance Recovery Period for 100% of Reportable Disturbances. 22

Preparedness Standards Entities actions to be prepared for conditions that are unlikely to occur, but are critical to reliability. Examples: EOP 001 (Emergency Operations Planning) EOP 005 (System Restoration) EOP 008 (Plans for Loss of Control Center Functionality) TOP 002 2a (Normal Operations Planning) plan, train, mitigate 23

Preparedness Standards EOP 005 1, R9. The TOP shall document the Cranking Paths, including initial switching requirements, between each blackstart generating unit and the unit(s) to be started and shall provide this documentation for review by the Regional Reliability Organization upon request. Such documentation may include Cranking Path diagrams. EOP 001 0,R3. Each TOP and BA shall: R3.1. Develop, maintain, and implement a set of plans to mitigate operating emergencies for insufficient generating capacity. 24

Organization Certification Standards Define essential capabilities to perform reliability functions. Examples: BAL 005 0.1b (Automatic Generation Control) PER 003 0 (Operating Personnel Credentials) IRO 002 1 (RC Facilities) TOP 005 1.1 (Operational Reliability Information) PER 001 0.1 (Operating Personnel Responsibility and Authority) Used to ensure organizations have the required capabilities 25

Organization Certification Standards PER 003 0, R1. Each TOP, BA, and RC shall staff all operating positions that meet both of the following criteria with personnel that are NERC certified for the applicable functions: ( ) PER 001 0.1, R1. Each TOP and BA shall provide operating personnel with the responsibility and authority to implement real time actions to ensure the stable and reliable operation of the Bulk Electric System. 26

More resources FERC Orders Reliability Standard Audit Worksheets (RSAWs) Compliance Application Notices (CANs) Interpretations Compliance Assessment Reports (CARs) 27

FERC Orders FERC is organization with original jurisdiction Comments enhance application, provide direction to NERC and industry Applicable sections are included in RSAWs, which are available on NERC.com > Compliance > Resources 28

Reliability Standard Audit Worksheets Designed to add clarity and consistency in compliance assessment Data source for audit review Can be helpful for your internal review 29

Compliance Application Notices (CANs) NERC.com > Compliance > Resources > Compliance Application Notices (on left) Clarify how compliance is being assessed across REs Often explain how the requirement will be audited; might describe expectations on evidence If a standard has a CAN, it is linked from the applicable standard Standards > Reliability Standards > PRC, TOP, etc. Could be replaced by interpretations or revised standards 30

Interpretations Attempt to clarify a standard Team will draft, balloting occurs as with a standard If approved, filed with regulatory authority Carries same weight as the standard! Will be incorporated in next revision In RSAWs If a Standard has an Interpretation, there is a link from NERC.com Standards > Reliability Standards > COM, CIP, etc. 31

Compliance Analysis Reports (CARs) NERC.com > Compliance > Resources > Compliance Analysis Reports (on left) Identify common pitfalls for most violated standards May provide suggestions for ways to improve your program If applicable, link by the applicable Standard Standards > Reliability Standards > COM, BAL, EOP, etc. 32

Summary Understanding how to read standards helps you develop internal procedures and ensure you are meeting all parts of standards You must follow performance based standards regardless of having a procedure Many standards include performance measures that will be used to analyze compliance Different types of standards have different compliance methods NERC.com has additional resources 33

Questions or Comments 34

Summary Understanding how to read standards helps you develop internal procedures and ensure you are meeting all parts of standards You must follow performance based standards regardless of having a procedure Many standards include performance measures that will be used to analyze compliance Different types of standards have different compliance methods NERC.com has additional resources 35

Greg Sorenson, PE Senior Compliance Engineer 501 688 1713 gsorenson.re@spp.org 36