FlameSpec SS Roof Underlay

Similar documents
SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

WATERTIGHT ROOF UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 938 [2017] Appraisal No. 938 (2017) BRANZ Appraisals

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

National Construction Code Series (NCC) Building Code of Australia (BCA)

PRODUCT CERTIFICATE THIS IS TO CERTIFY THERMAKRAFT STEELWRAP 290 WALL UNDERLAY

Bituminous Roofing Underlay & Valley Guard

Bituminous Building Paper

Barricade. Breathable & Water Resistant Keeping your Frame Nice and Dry. Building Wrap 50 YEARS. Order your FREE sample today!

Thermakraft FIRE RETARDANT SELF SUPPORTING ABSORBENT BREATHABLE SYNTHETIC NON-WOVEN ROOF UNDERLAY STRENGTH BREATHER SHEET WATER RESISTANCE

THE THERMAKRAFT ONE WRAP SYSTEM. Product. Scope. Appraisal No. 962 [2017] Appraisal No. 962 (2017) BRANZ Appraisals

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

12/12/2017 CMA-ER30204

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

THERMAKRAFT ALUBAND WINDOW FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 878 [2014]

TRADE-COURSE DPC AND FLASHING. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 849 [2014] Appraisal No.

DYNAFLASH FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 913 [2016] Appraisal No. 913 (2016) Amended 06 October 2016.

SUPERCOURSE 500 DAMP-PROOF COURSE AND CONCEALED FLASHING. Product. Scope. Building Regulations. Appraisal No. 329 [2016]

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

SOLITEX MENTO. Roof Underlays. Waterproof Weathertight. Windproof Durable Y E S P L E A S E!

ROOF VENTILATION PRODUCTS. Product. Scope. Appraisal No. 979 [2017] Appraisal No. 979 (2017) Amended 06 December 2018.

ROOF VENTILATION PRODUCTS. Product. Scope. Appraisal No. 979 [2017] Appraisal No. 979 (2017) BRANZ Appraisals

QUICKFLASH READY- MADE FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 688 [2018]

FRAMEFLASH / WATERTIGHT FLASHING TAPE. Product. Scope. Appraisal No. 631 [2017]

HIGH-PERFORMANCE ROOFING UNDERLAYS AND BUILDING MEMBRANES

TESCON EXTORA SEALING TAPE. Product. Scope. Appraisal No. 838 [2013] Appraisal No. 838 (2013) Amended 30 June 2017.

MULTI-FIT PENETRATION SEALS. Product. Scope. Appraisal No. 942 [2017] Appraisal No. 942 (2017) BRANZ Appraisals

BUILDBASE SUPPLIED BY IKO BREATHER MEMBRANE FOR USE IN TIMBER FRAME CONSTRUCTIONS

Building Regulations

HIGH-PERFORMANCE ROOFING UNDERLAYS AND TIMBER FRAME MEMBRANES

CAVIBAT ROOF BATTENS. Product. Scope. Building Regulations. Appraisal No. 992 [2017] Please Note: Roof underlay not shown under flashing for clarity.

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS

SNUG UNDERFLOOR INSULATION. Product. Scope. Building Regulations. Appraisal No [2018] Appraisal No (2018) Amended 28 June 2018

Appraisal No. 719 (2011) BRANZ Appraisals Marshall Innovations Limited BRANZ

nu-wall aluminium vertical cladding system

NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM. Product. Scope. Appraisal No. 556 [2007] Appraisal No. 556 (2007) Amended 20 November 2015.

EZYCORNER CAVITY FLASHING. Product. Scope. Building Regulations. Appraisal No. 920 [2016] Appraisal No. 920 (2016) BRANZ Appraisals

ECOTUFF TPO ROOF AND DECK MEMBRANE. Product. Scope. Appraisal No. 792 [2012] Appraisal No. 792 (2012) Amended 05 October 2016.

AUTEX GREENSTUF UNDERFLOOR INSULATION. Product. Scope. Building Regulations. Appraisal No. 734 [2016]

PINK BATTS INSULATION. Product. Scope. Building Regulations. Appraisal No. 238 [2012]

DRYPROOF UNDER TILE EXTERNAL WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 887 [2015] Appraisal No. 887 (2015) Amended 17 September 2015

MLC MASONRY AND BRICK PLASTER SYSTEM. Product. Scope. Appraisal No. 839 [2013] Appraisal No. 839 (2013) BRANZ Appraisals

STEALTH ROOFLIGHTS. Product. Scope. Appraisal No. 987 [2018] Appraisal No. 987 (2018) BRANZ Appraisals

CERTIFICATE No VTT-C Date of issue

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

FIRESTONE RUBBERCOVER EPDM MEMBRANE. Product. Scope. Appraisal No. 893 [2015] Appraisal No. 893 (2015) Amended 24 November 2017.

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals

PRIMA CERAMIC TILE UNDERLAY. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 636 [2008]

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

Product. BRANZ APPRAISAL No. 789 (2012) Scope. Hard as Rocks Ltd PO Box 1703 Taupo 1351

Co-extruded 3 Layer Films

VIKING GM TORCH ON MEMBRANES. Product. Scope. Appraisal No. 948 [2017] Appraisal No. 948 (2017) BRANZ Appraisals

Assessment Brief. CMA-CM40125 MASONS Plastabrick Ltd 9A Parkhead Place Albany, Auckland 0632 NEW ZEALAND Phone:

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

SRP-AirOutshield UV Issued:

PREMIER INSULATION. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 509 [2014]

DAVCO K10 PLUS AND K10 RAPID WET AREA MEMBRANES. Product. Scope. Building Regulations. Appraisal No. 609 [2017]

PROTECTO TAPE FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 450 [2017]

DS411 Exterior. Product. BRANZ APPRAISAL No. 788 (2012) Scope. Wet-seal New Zealand Ltd P O Box Takapuna Auckland Tel:

weathertex sheet Product BRANZ APPRAISAL No. 514 (2006) Scope Weathertex Pty Ltd P O Box 21 Raymond Terrace NSW 2324 Australia

Solitex WA Breathable Wall Protection Membrane

THE A PROCTOR GROUP VAPOUR AND LOW AIR PERMEABLE MEMBRANE FRAMETITE FOR USE IN WALLS

Product. BRANZ APPRAISAL No. 484 (2012) Scope. Mapei New Zealand Ltd P O Box Penrose Auckland. Tel: Fax:

NZ Brick Distributors Canterbury Clay Bricks Clay Bricks Ltd Brick and Stone Imports T/A Midland Brick NZ Full contact details are given on page 9.

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

JENKIN A-LIGN BEVELBACK WEATHERBOARD DIRECT FIXED CLADDING SOLUTION

PINK BATTS POLYESTER INSULATION. Product. Scope. Building Regulations. Appraisal No. 999 [2018] Appraisal No. 999 (2018) BRANZ Appraisals

PRODUCT GUIDE T HERMOFOIL THERMOFOIL

GIB FIRE RATED SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 289 [2018] Logo. Appraisal No. 289 (2018) BRANZ Appraisals

National Construction Code Series (NCC 2016) Building Code Of Australia (BCA)

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

LIQUID NAILS HIGH STRENGTH CONSTRUCTION ADHESIVE. Product. Scope. Appraisal No. 325 [2016]

durotuf TPO WATERPROOFING MEMBRANE Product Scope Appraisal No. 950 [2017] Appraisal No. 950 (2017) Amended 24 May 2018 BRANZ Appraisals

PREVENTING MOISTURE PROBLEMS IN TIMBER-FRAMED SKILLION ROOFS. Issue525

SUPERFLEX EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 473 [2011] Appraisal No. 473 (2011) Amended 08 August 2016.

nu-therm system Product BRANZ APPRAISAL No. 456 (2005) Scope Nu-Age Plaster Limited P O Box 195 Matamata

USG BORAL WET AREA SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 955 (2017) BRANZ Appraisals

Insulbreak. Insulation. thermal break solution

Product. BRANZ APPRAISAL No. 553 (2007) Scope. Nuplex Industries Ltd C/- Nuplex Construction Products PO Box Glenfield Auckland

MAPELASTIC, MAPELASTIC SMART AND MAPELASTIC TURBO EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 485 [2018]

Product. BRANZ APPRAISAL No. 769 (2012) Scope. Celcrete International Ltd PO Box 2382 Tauranga

NZQA Expiring unit standard version 2 Page 1 of 5. Describe metal roof and wall cladding preparation and installation procedures

Brick Veneer Walls. Insulation

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

AQUABLOK INTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 724 [2017]

METRA INTER- TENANCY WALL SYSTEM. Product. Scope. Appraisal No. 985 [2018] Appraisal No. 985 (2018) BRANZ Appraisals

danpalon glazing system - housing Product BRANZ APPRAISAL No. 526 (2006) Scope Everlight NZ Ltd P O Box Whenuapai Waitakere 0662 Auckland

MAPEGUM WPS AND MAPELASTIC WET AREA MEMBRANES

SIKAROOF MTC ROOF AND DECK MEMBRANE. Product. Scope. Appraisal No. 670 [2017]

Concrete Soffit Direct Fix

Typical waterproofing using Shelterseal 3000X

VIKING GM MERCURY FC DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 864 [2014] Appraisal No. 864 (2014) Amended 11 May 2017

FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 800 [2013] Appraisal No. 800 (2013) Amended 05 February 2016.

Transcription:

CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Appraisals... 2 Product Information... 3 Handling & Storage... 4 Technical Data... 4 Installation Information... 5 Size Range Available... 5 Building products you can count on FREEPHONE 0800 330 320 Page 1 of 5

SUMMARY OF FEATURES A synthetic self supporting building underlay for use under roof claddings. BRANZ appraised for use in all areas without restriction. Consists of a micro-porous water resistant film, laminated to two layers of non-woven spun-bonded polyolefin. The modern alternative to conventional self-supporting kraft paper underlays. Used to reduce drafts and assist in moisture management. Stronger and more resistant to shrinkage than kraft based papers. Water resistant and will not rot. Grey colouring reduces glare for significantly less eye-strain during application. Printed with laying lines for ease of installation. Suitable for use in all Building Wind Zones of NZS 3604 up to, and including Extra High. May be installed in wet conditions without affecting its surface. Breathable water resistant film reduces the risk of condensation when compared with conventional kraft papers. AS 1530.2 Flammability index of <5. Suitable for timber framed and steel framed structures. TECHNICAL INFORMATION Product Description Fastwrap FlameSpec SS Roof Underlay is a self supporting synthetic building underlay for use under roof claddings. It consists of a micro-porous water resistant film, laminated to two layers of non woven spun-bonded polyolefin. Applications Fastwrap FlameSpec SS Roof Underlay is for use as a self supporting roof underlay on buildings within the following: the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and floor plan area with masonry tile roof cladding with metal tile and profiled metal roof cladding situated in NZS 3604 Building Wind Zones up to, and including Extra High Appraisals BRANZ Appraisal No. 715 (2017). Amended 29 June 2018 Building products you can count on FREEPHONE 0800 330 320 Page 2 of 5

Product Information Timber and steel roof framing must be provided in accordance with the requirements of the NZBC and the roof cladding manufacturer. Fastwrap FlameSpec SS Roof Underlay is intended for use as an alternative to conventional kraft paper roof underlays, which are fixed over timber or steel framed roofs in order to limit the entry of wind into the roof cavity, and to assist in the moisture management of the roof cladding system. The material also provides a degree of temporary weather protection during early construction. However, the product will not make the roof weather-tight and some wetting of the underlying structure is always possible before the roof cladding is installed. Hence, the entire building must be closed in and made weatherproof before moisture sensitive materials such as ceiling linings and insulation materials are installed. Fastwrap FlameSpec SS Roof Underlay must not be exposed to the weather or ultra violet light for a total of more than 7 days before being covered by the roof cladding. Fastwrap FlameSpec SS Roof Underlay is suitable for use under roof claddings on buildings as a roof underlay, as called up in NZBC Acceptable Solution E2/AS1, Table 23. Refer to the table below for the material properties of the Fastwrap FlameSpec SS Roof Underlay. Fastwrap Flamespec SS Roof Underlay is suitable for use at roof pitches 3 and above. When used at pitches less than 10, Fastwrap Flamespec SS Roof Underlay can be installed horizontally or vertically when fully supported by a corrosion resistant roof underlay support. At pitches 10 and greater, Fastwrap FlameSpec SS Roof Underlay can be installed vertically or horizontally, spanning no greater than 1200mm between supports. Fastwrap FlameSpec SS Roof Underlay is suitable for use in all Building Wind Zones of NZS 3604 up to, and including, Extra High. Fastwrap FlameSpec SS Roof Underlay meets code compliance with NZBC Clause B2.3.1 (a), not less than 50 years for roof underlays used where the roof cladding durability requirement or expected serviceable life is not less than 50 years, e.g. behind masonry roof tile cladding, and code compliance with NZBC Clause B2.3.1 (b), 15 years for roof underlays used where the roof cladding durability requirement is 15 years. Provided it is not exposed to the weather or ultra-violet light for a total of more than 7 days, and provided the roof cladding is maintained in accordance with the cladding manufacturer s instructions and the roof cladding remains weather resistant, Fastwrap FlameSpec SS Roof Underlay is expected to have a serviceable life equal to that of the roof cladding. Fastwrap FlameSpec SS Roof Underlay has an AS 1530.2 Flammability Index of 5 and meets the requirements of NZBC Acceptable Solution C/AS1 Part 6, Table 6.2 for surface finish requirements for suspended flexible fabrics, and therefore may be used with no restrictions in all buildings. The Flammability Index of Fastwrap FlameSpec SS Roof Underlay has been evaluated in accordance with AS 1530.2. Fastwrap FlameSpec SS Roof Underlay must be separated from fireplaces, heating appliances, flues and chimneys in accordance with the requirements of NZBC Acceptable Solution C/AS1 Part 9 for the protection of combustible materials. Fastwrap FlameSpec SS Roof Underlay must only be used under roof claddings that meet the requirements of the NZBC, such as those covered by NZBC Acceptable Solution E2/AS1, or roof claddings covered by a valid BRANZ Appraisal. Building products you can count on FREEPHONE 0800 330 320 Page 3 of 5

Fastwrap FlameSpec SS Roof Underlay, when installed in accordance with the information in this brochure and the valid BRANZ Appraisal, will assist in the total cladding system s compliance with NZBC Clause E2. Fastwrap FlameSpec SS Roof Underlay, if used, designed, installed and maintained in accordance with the information contained within the valid BRANZ appraisal, will meet, or contribute to meeting the following provisions of the NZBC: Clause B2 Durability: Performance B2.3.1(a), not less than 50 years, B2.3.1(b), 15 years and B2.3.2. Fastwrap FlameSpec SS Roof Underlay meets these requirements. Clause E2 External Moisture: Performance E2.3.2. When used as part of the roof cladding system, Fastwrap FlameSpec SS Roof Underlay will contribute to meeting this requirement. Clause F2 Hazardous Building Materials: Performance F2.3.1. Fastwrap FlameSpec SS Roof Underlay meets this requirement and will not present a health hazard to people. The following tests have been carried out on Fastwrap FlameSpec SS Roof Underlay in accordance with NZBC Acceptable Solution E2/AS1, Table 23: tensile strength, edge-tear resistance and resistance to water vapour transmission in accordance with AS/NZS 4200.1, shrinkage in accordance with AS/NZS 4201.3, resistance to water penetration in accordance with AS/NZS 4201.4, surface water absorbency in accordance with AS/NZS 4201.6 and ph of extract in accordance with AS/NZS 1301.421s. A range of these tests were completed before and after Fastwrap FlameSpec SS Roof Underlay was exposed to ultra-violet light. NZBC E2/AS1 TABLE 23 REQUIREMENTS NZBC E2/AS1 Table 23 Roof Underlay Properties Property Performance Requirement Results Absorbency 150 g/m2 Pass Vapour Resistance 7 MN s/g Pass Water Resistance 100mm Pass ph of Extract 6 and 9 Pass Shrinkage 0.5% Pass Mechanical Edge tear and tensile strength Edge tear (Average): Machine direction = 229 N, Cross direction = 145 N, Tensile strength (Average): Machine direction = 4.47 kn/m, Cross direction = 2.80 kn/m Handling & Storage Handling and storage of Fastwrap FlameSpec SS Roof Underlay, whether on or off site, is under the control of the installer. The rolls must be protected from damage and weather. They must be stored on end, under cover, in clean, dry conditions and must not be crushed. Technical Data Fastwrap FlameSpec SS Roof Underlay is a synthetic building underlay for use under roof claddings. The product consists of a micro-porous water resistant film laminated to two layers Building products you can count on FREEPHONE 0800 330 320 Page 4 of 5

of non woven spun-bonded polyolefin. Fastwrap FlameSpec SS Roof Underlay is coloured grey on the top face and white on the bottom face, and is printed with laying lines. Fastwrap FlameSpec SS Roof Underlay is supplied in rolls 1.250m wide x 40m long. The product is printed with the Fast Wrap logo repeated along the length of the roll. The rolls are wrapped in clear polythene film. Accessories used with Fastwrap FlameSpec SS Roof Underlay which are supplied by the installer are: Fixings stainless steel staples, clouts, screws or proprietary underlay fixings, or other temporary fixings to attach the roof underlay to the framing. Installation Information Installation must always be carried out in accordance with the Fastwrap FlameSpec SS Roof Underlay technical literature and the BRANZ appraisal, by competent tradespersons with an understanding of roof underlay installation. Fastwrap FlameSpec SS Roof Underlay must be fixed at maximum 300mm centres to all framing members with large-head clouts 20mm long, 6-8mm stainless steel staples, self drilling screws or proprietary underlay fixings. The membrane must be pulled taut over the framing before fixing. Fastwrap Flamespec SS Roof Underlay is suitable for use at roof pitches 3 and above. When used at pitches less than 10, Fastwrap Flamespec SS Roof Underlay can be installed horizontally or vertically when fully supported by a corrosion resistant roof underlay support. At pitches 10 and greater, Fastwrap FlameSpec SS Roof Underlay can be installed vertically or horizontally, spanning no greater than 1200mm between supports. It must extend from the ridge and overhand the fascia board by 20-25mm. Vertical laps must be no less than 150mm wide. Horizontal laps must also be no less than 150mm, with the direction of the lap ensuring that water is shed to the outer face of the underlay. End laps must be made over framing and be no less than 150mm wide. When fixing the product in windy conditions, care must be taken due to the large sail area created. Any damaged areas of Fastwrap FlameSpec SS Roof Underlay, such as tears, holes or gaps around service penetrations, must be repaired. Damaged areas can be repaired by covering with new material, lapping the damaged area by at least 150mm and taping, or by taping small tears. In buildings which may be subject to infestation by birds or rodents we recommend that roof underlay is protected using Bayonet Hexagonal Wire Netting (50mm). Fastwrap FlameSpec SS Roof Underlay must not be used under translucent sheeting. Size Range Available Product Code Width (mm) Length (m) Total (m 2 ) Weight (kg) Barcode FSSS125050 1250 40 50 10 9421026720009 Building products you can count on FREEPHONE 0800 330 320 Page 5 of 5