Thermal Performance of Northern Facades ISO Clip System Summary

Similar documents
Thermal Performance of Nvelope NV1 Clip System

Thermal Performance of Nvelope NV1 Clip System

Thermal Analysis of CL-TALON Cladding Support System

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Thermal Bridging and Whole Building Energy Performance

FERO RAP TIE AND FAST SYSTEM THERMAL ANALYSIS

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

THERMAL BRIDGING OF MASONRY VENEER CLADDINGS & ENERGY CODE COMPLIANCE

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures

Understanding the National Energy Code of Canada for Buildings, 2011

ENCLOSURE SOLUTIONS THERMAL BRIDGING GUIDE FIBERGLAS FOAMULAR THERMAFIBER

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

OUTLINE. Building Envelope Thermal Bridging Guide. High Level Overview and Themes. The Code Context. The Energy Context. Where do we go from here?

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

Building Envelope

Break it, or Lose it: Thermal Bridging in Building Envelopes

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

Impact of Insulated Concrete Curb on Concrete Balcony Slab

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

Agenda. Scope. Market and code. Impact to Buildings. Design Solution. Future. page 2

The Importance of Slab Edge & Balcony Thermal Bridges

Professional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes

THE IMPORTANCE OF BALCONY AND SLAB EDGE THERMAL BRIDGES IN CONCRETE CONSTRUCTION

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Vanglo House LWPAC. Shannon Estates PERKINS + WILL. Erl Tirol - Festival hall DELUGAN MEISSL. Norma Rose Point Secondary. page 1

Residential Energy Code Compliance

PART 1 BUILDING ENVELOPE THERMAL ANALYSIS (BETA) GUIDE

Thermal Bridging and Energy Standards 2014 BOABC Education Conference. November 27, 2014

Accounting for Thermal Bridging at Interface Details. A Methodology for De-Rating Prescriptive Opaque Envelope Requirements in Energy Codes

National Institute of Building Sciences

INSULATION VALUES TECHNICAL BULLETIN Vol. 3, No. 1 JANUARY 2017

The Effective Thermal Performance of the Building Enclosure: Exterior Walls

Meeting & Exceeding Thermal Requirements of the Code

ASHRAE Research Project Report RP-1365

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

The Role of Control Layers in Building Enclosure Design

Building Enclosure Details and Assemblies for Wood-Frame Buildings

ResearcH JournaL 2016 / VOL

INSULATION VALUES. Metric Version

Manitoba Energy Code for Buildings. Part 3 Building Envelope

Insulation Fastener Guide IKO Ener-Air & IKO Enerfoil Wall Insulation

9.36. Energy Efficiency

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Exterior Insulation and the Cascadia Clip Presenter: Maddy Parrott

The Importance of Slab Edge & Balcony Thermal Bridges

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

Cladding Attachment Through Exterior Insulation Using Long Screws PHIUS 10 TH ANNUAL NAPHC, CHICAGO COLIN SHANE M.ENG, P.ENG 11 SEPTEMBER 2015

No ASHRAE Standard By Susan Hayes, P.Eng., LEED AP BD+C & Graham Finch, Dipl.T, MASc, P.Eng. October 2012 rdh.com 1

Residential Energy Code Update

What s My Baseline? ASHRAE

Attaching Cladding with Long Screws

UL Design System HW-D-1012 continued

Thermal Bridging: It Can Be Done Better

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Residential High Performance Walls

Carter Fabricating Inc. 326 Deerhurst Drive Brampton, Ontario L6T 5H9. Mr. Mike Libreiro

2010 National Building Code Adoption and Associated Process Changes

Deer Ridge Consulting, Inc.

Managing Condensation and Thermal Performance with Continuous Insulation

Using Thermal Modeling to Evaluate Cladding Support Systems

Thermal Bridging in Residential Construction

ONTARIO ENERGY CODES COMMERCIAL & RESIDENTIAL

The Role of Control Layers in Building Enclosure Design

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

Armatherm Structural Thermal Bridging Solutions

Building Envelopes 101

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Attaching Cladding with Long Screws. Presented by: Michael Aoki-Kramer LEED AP

Ontario s Building Code

Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building

calibrated gas flows from the room burner.

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

NBC Calculator Tool Manual

THERMAL BRIDGING CALCULATIONS AND IMPACTS

WILL THE REAL R-VALUE PLEASE STAND UP

COMMERCIAL ENERGY EFFICIENCY

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Welcome to this continuing education seminar. This is the second of three parts of the Building Enclosure Fundamentals series.

Changes. With respect to Energy efficiency 2006 Code is 22% better than 1997 Code Code 37% better than 1997 Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DYNAMIC EFFECT OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS IN BC. Fuad Baba*, Hua Ge

Insulation Retrofit Options

SECTION COLD-FORMED METAL FRAMING

Thermal Bridging Solutions. Improving Building Envelope Performance

9.36 Energy Efficiency

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Carter Architectural Panels Inc. 221 E. Willis Road A Unit 18 Chandler, AZ Mr. Bruce Bourne

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

Where to Draw the Line with Thermal Boundaries

Study of potential nonconformities of a new recreation center building's envelope

RainBarrier Installation Guide

Transcription:

Thermal Performance of Northern Facades ISO Clip Summary The Northern Facades ISO Thermal Clip is a steel clip system for attaching cladding systems to various types of exterior insulated wall assemblies. Morrison Hershfield was contracted by Northern Facades Ltd. to evaluate the thermal performance of their clip system for several construction scenarios. The ISO Clip provides a thermally broken and intermittent structural attachment for cladding systems to exterior wall assemblies. The clip is fabricated from Z-275 galvanized steel, and overmolded with a plastic isolator. Both horizontal and vertical steel girts can be attached to the ISO Clip, as shown in Figures 1 & 2. The horizontal and vertical flanges of the clip have punched slots that allow the sub-girts to be adjusted and fastened to the clip. The plastic isolator between the metal clip and the wall provides a thermal break that reduces thermal bridging. For steel stud assemblies, the clips are fastened through the exterior sheathing directly to the steel studs using self-drilling screws. Figure 1: ISO Clip with Vertical Girt Attachment Figure 2: ISO Clip with Girt Attachment Modeling was done using a general purpose computer aided design (CAD) and finite element analysis (FEA) package. The thermal solver and modeling procedures utilized for this study were extensively calibrated and validated for Research Project 1365-RP Thermal Performance of Building Envelope Details for Mid- and High-Rise Construction (1365-RP)1. Several construction scenarios were investigated for the ISO Clip, including various backup walls, insulation placement, and slab edge detail. This summary highlights results for the ISO Clip with an exterior insulated steel stud wall, as shown in Figure 3. For additional results, please see the full report2. 1 http://www.morrisonhershfield.com/ashrae1365research/pages/insights-publications.aspx 2 Thermal Performance of Northern Facades ISO Clip, August 5th, 2014

Figure 3: Exterior Insulated Steel Stud Wall Assembly with Vertical and Girts The vertical and horizontal configurations of the ISO Clip were modelled with clips ranging from 24 to 60 vertically, and 16 to 24 horizontally and between 4-6 of exterior mineral wool insulation (R-4.2 per inch). They also included all the components of the steel stud assembly, including 3 5/8 (90 mm) steel studs spaced at either 16 or 24 inches o.c., exterior sheathing and interior drywall. The exterior cladding and cavity were not explicitly modelled, but their effects were incorporated into the exterior air film coefficient accordingly. The thermal transmittance (U-value) and thermal resistance (R-value) of the modelled exterior insulated systems are shown in Tables 1 and 2 respectively. The overall effectiveness of the thermal insulation for the vertical sub-girt system ranges from 60% to 78% depending on the vertical clip spacing and thickness of insulation. In comparison, the effectiveness of insulation in typical continuous vertical girt systems ranges from 40% to 50% over the same range of insulation levels 3. For the horizontal system with steel studs spaced 16 o.c., the effectiveness ranges from 65% to 89%, depending on vertical clip spacing and amount of insulation. For steel studs and clips spaced at 24 o.c., the effectiveness increases to 70% to 91%. This is compared to continuous horizontal girt systems (without clips), which range from 50% to 60% effectiveness over the same range of insulation levels 2. 3 Results in 1365-RP Final Report, http://www.morrisonhershfield.com/ashrae1365research/pages/insights- Publications.aspx

and Stud Table 1: Thermal Transmittances for Exterior Insulated Steel Stud Wall Assemblies with ISO Clip Effective Assembly U-Value BTU/hr ft 2 of (W/m 2 K) Exterior Insulation Thickness (in) Exterior Insulation Nominal R-Value 4 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip 36 Vertical Clip 48 Vertical Clip 60 Vertical Clip Vertical 24 Stud 4 16.8 (2.96) 0.070 (0.398) 0.066 (0.376) 0.063 (0.357) 5 5 21.0 (3.70) 0.063 (0.360) 0.060 (0.340) 0.058 (0.327) 0.056 (0.320) 5 6 25.2 (4.44) 0.059 (0.334) 0.055 (0.315) 0.053 (0.302) 0.051 (0.292) 5 4 16.8 (2.96) 0.066 (0.377) 0.061 (0.347) 0.058 (0.331) 0.057 (0.321) 5 21.0 (3.70) 0.059 (0.335) 0.053 (0.303) 0.050 (0.286) 0.048 (0.275) 6 25.2 (4.44) 0.054 (0.307) 0.048 (0.273) 0.045 (0.254) 0.043 (0.243) 4 16.8 (2.96) 0.062 (0.354) 0.058 (0.332) 0.056 (0.319) 0.055 (0.312) 5 21.0 (3.70) 0.055 (0.314) 0.051 (0.289) 0.048 (0.275) 0.047 (0.266) 6 25.2 (4.44) 0.050 (0.286) 0.045 (0.258) 0.043 (0.244) 0.041 (0.235) and Stud Vertical 24 Stud Table 2: Thermal Resistance for Exterior Insulated Steel Stud Wall Assemblies with ISO Clip Exterior Exterior Insulation Assembly Effective R-Value Insulation Nominal hr ft 2 of/btu (m 2 K/W) Thickness R-Value 4 24 Vertical 36 Vertical 48 Vertical 60 Vertical (in) hr ft 2 of/btu (m 2 K/W) 4 16.8 (2.96) R-14.3 (2.51) R-15.1 (2.66) R-15.6 (2.75) R-15.9 (2.80) 5 5 21.0 (3.70) R-15.8 (2.78) R-16.7 (2.94) R-17.4 (3.06) R-17.7 (3.13) 5 6 25.2 (4.44) R-17.0 (2.99) R-18.0 (3.18) R-18.8 (3.31) R-19.4 (3.42) 5 4 16.8 (2.96) R-15.1 (2.65) R-16.4 (2.88) R-17.2 (3.02) R-17.7 (3.12) 5 21.0 (3.70) R-16.9 (2.98) R-18.7 (3.3) R-19.8 (3.5) R-20.6 (3.64) 6 25.2 (4.44) R-18.5 (3.26) R-20.9 (3.67) R-22.3 (3.93) R-23.4 (4.12) 4 16.8 (2.96) R-16.0 (2.82) R-17.1 (3.01) R-17.8 (3.13) R-18.2 (3.21) 5 21.0 (3.70) R-18.1 (3.19) R-19.7 (3.47) R-20.7 (3.64) R-21.3 (3.75) 6 25.2 (4.44) R-19.9 (3.50) R-22.0 (3.87) R-23.3 (4.10) R-24.2 (4.26) 4 This is the nominal insulation value only. The assembly effective values also include air films and the resistance of the backup wall assembly 5 Highlighted values were interpolated and not explicitly modelled.

Thermal profiles for the exterior insulated steel stud assemblies with the vertical and horizontal configurations of the ISO Clip are shown in Figures 4 and 5 respectively. These figures use a temperature index, which has a value between 0 1, where 0 represents the outdoor temperature and 1 represents the indoor temperature. This allows the thermal profile to be applicable to any temperature difference. Figure 4: Temperature profile for exterior insulated steel stud wall with ISO Clip and vertical girts, 5 exterior insulation and clips spaced 36 o.c. Figure 5: Temperature profile for exterior insulated steel stud wall with ISO Clip and horizontal girts, 5 exterior insulation and clips spaced 36 o.c.

For commercial or mid and high rise construction (non-part 9), many codes reference standards from national and international organizations. In regards to the building envelope, the most commonly referenced standards across Canada are 90.1 Energy Standard for Buildings Except Low-Rise Buildings and the National Energy Code for Buildings (NECB) 2011. While these standards differ in their specific requirements, they both employ three options for showing compliance: Prescriptive, Trade-off and Performance. The prescriptive path awards compliance for explicitly meeting all provisions of the code relevant to the project. For the building envelope, assemblies must have a lower than specified maximum thermal transmittance U-value or must meet or exceed insulation values in a prescribed assembly. These requirements can be based on climate region, building type/principal heating source and construction type, depending on the standard. The prescriptive path is widely used as it is fairly straight forward and building components need only be assessed individually. However, some of the prescriptive requirements may be difficult to achieve due to design trends. For example, in, the prescriptive path requires a glazing to wall ratio of less than 40%, otherwise another compliance path must be used. The trade-off path allows for projects to trade-off the performance of building envelope components (i.e. roofs, walls, and windows) when the prescriptive requirements are not met. With this approach, the performance of some envelope components may be lower than the prescribed values in the standard as long as other components exceed the requirements so that the overall building envelope is deemed to be equal or better than the standard. This allows for the relaxation of the wall U-value requirements if the roof or windows sufficiently compensate for the difference. This approach can be demonstrated using methodology in the standards or through computer software designed for demonstrating compliance. The performance path requires an evaluation of the annual energy use of the whole building. This must be done using computer simulation, where the proposed building and its systems are modeled and compared to a baseline compliant building. The baseline compliant building has the same shape, size, occupancy and scheduling as the proposed building, but all of its systems and individual components meet the minimum requirements of the standard. For the compliance building, the thermal performance of the walls must match the prescriptive U-values of the standard. The proposed design building complies with the standard or code if the annual energy use or cost is equal to or less than the baseline compliant building. This allows the envelope performance to be less than the prescriptive requirements as long as another components (like the mechanical system) can make up for the additional energy use. Energy certification programs like LEED have used MNECB and performance paths to allow for more flexibility in design. The performance path takes into account other variables such as higher efficiency HVAC systems and lighting power and controls, which would not give any benefit with the other two compliance paths. Each standard specifies what can and cannot be included in the energy model. separates the prescriptive requirements by wall type (mass, woodframed, steel-framed etc.) and by building type (residential, non-residential), however NECB 2011 does not and provides the same requirements regardless of wall and building type. Below is a summary of the prescriptive wall assembly requirements from 90.1 2010 for steel framed buildings and mass walls along with wall assembly requirements from NECB 2011. Canadian climate zones in both and NECB are divided by heating degree days (HDD). Note, there are no climate zones in Canada below Zone 4.

Climate Zone Table 3: Prescriptive Requirements for and NECB 2011 per climate zone NECB Climate Zones Heating Degree Days (HDD) Steel Framed, Non- Maximum Assembly U-Value Steel Framed BTU/hr ft 2 o F (W/m 2 K) Mass Wall, Non- Mass Wall, NECB-2011 4C 4 < 3000 0.104 (0.591) 0.090 (0.511) 0.055 (0.315) 5A, 5B and 5C 5 3000-4000 0.090 (0.511) 0.080 (0.454) 0.049 (0.278) 6A, 6B 6 4000-5000 0.080 (0.454) 0.044 (0.247) 7 7A 5000-6000 7B 6000-7000 0.042 (0.238) 0.042 (0.238) 0.037 (0.210) 0.037 (0.210) 8 8 >7000 0.037 (0.210) 0.052 (0.295) 0.032 (0.183) The data in Tables 1 and 2 can be used to compare to any of the energy efficient requirements and compliance paths for the building envelope in the relevant Canadian energy codes and standards. The ISO system makes meeting these energy standards feasible in contrast to continuous z-girts for attaching cladding. As way of an example, the prescriptive U-value requirements for for steel framed non-residential building is BTU/hr ft 2 of for all climate zones above 4. From the simulated results in Table 1, it can be determined that the horizontal ISO system can meet this prescriptive requirement with four inches of exterior mineral wool insulation and with clips spaced at a minimum of 36 inches o.c. vertically and 16 inches o.c. horizontally.

For exterior insulated steel stud assemblies, the ISO Clip provides an effective means of reducing thermal bridging in exterior façade systems compared to traditional continuous girt systems. The ISO Clip can be used to meet many of the demanding thermal requirements from current energy codes and standards in Canada. The U- and R- values provided by this summary can be used for compliance calculations for any of the compliance paths set forth in 90.1, NECB or SB-10. The main report for the ISO Clip contains results for additional scenarios, including additional backup walls, slab edge effects and sensitivity analysis for other construction modifications to the system. Key takeaways from the main report include: The horizontal system is more effective than the vertical system. For each system, there is a significant improvement with increasing clip spacing. With the inclusion of interior R-12 batt, the clear wall thermal resistance gains approximately R-5.5 for the vertical system and between R-6 and R-7.5 for the horizontal system. The concrete block wall system had over an R-1 improvement compared to the same system with the steel stud backup wall There are minor effects on the thermal resistance of the system when the assembly does not have a vented cavity behind the cladding. There is negligible impact on the thermal resistance of the assembly with the introduction of additional steel members, such as a hat track, outboard of the insulation and ISO Clip. For more information, please see the full report for the ISO Clip. Morrison Hershfield Ltd. Neil Norris, M.A.Sc. Building Science Consultant Patrick Roppel, P.Eng. Associate, Building Science Specialist