Semi-detached house in De Pinte, Belgium

Similar documents
Row House Henz-Noirfalise in Eupen, Belgium

Single family low energy house, Herselt, Belgium

Single family house in Herselt BE

Apartments and offices in Brussels, Belgium

5 social row houses (Wachtebeke)

Apartment building Sodastraße 40 in Ludwigshafen, DE

2000 Antwerp, terraced house

Passive House Project documentation

Passivhaus Project Documentation Wrexham Passivhaus

Balta Eco Project. group 1

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

Energy consumption and thermal comfort in a passive house built in Romania

Project Description. Projected build start date Projected date of occupation. Existing external wall construction.

PASSIVE HOUSE OBJECT DOCUMENTATION

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec

Construction Studies Theory - Higher Level

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

Warm climate - Passivhaus system

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Cool temperate climate - Passivhaus system

Cady-Guyton Residence

Construction Studies Theory - Higher Level

Construction Studies Theory - Higher Level

ROW - Albertslund, DK

71 kwh/(m²a) Project Documentation. 1 Abstract. Single family house in Bellbrae, Victoria, Australia. 1.1 Data of building. Year of construction

Single family semi-detached four-bedroom home in London, England

Attic conversion in Innsbruck AT

1_Abstract of the PassivHaus in Arrúbal (La Rioja).

IFORE Retrofitting Works Outreau. Pre-retrofit Description

Built examples and project certification. Zeno Bastian, Passive House Institute

Project name SOLAR HOUSE 80/50 Project summary

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Construction Studies Theory - Higher Level

Adaption of the passive house concept in northern Sweden - a case study of performance

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

LITTLEPITS PASSIVHAUS PLUS

Project Description. Projected build start date 19 Apr 2010 Projected date of occupation 30 Sep

Chapter Four: Green Remodeling Illustrations

PassiveDesign.org. Principles of Passive Design

PassiveDesign.org. Passive Construction. Name:...

Renovation of the Brogården area to Passive Houses

Plan /Submission Requirements

Deliverable Report Deliverable No.: D2-07 Work Package No: 02 CONCERTO INITIATIVE SERVE

Principles of Green Architecture

Passive House Object Documentation

Kindergarten Vejtoften, Høje-Taastrup, Denmark

Towards nzeb buildings: a historical building case study

The Net-Zero building Solar 2002

Retrofit of an historical building toward NZEB

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

PASSIVE HOUSE. is a building, which doesn t need an active type of heating. Dr. Ing Mihail Stancu

CONSTRUCTIVE STUDY OF A DANISH SINGLE FAMILY SECOND HOUSE IN VILAFAMÉS. RENEWABLE ENERGIES, MATERIALS, CONSTRUCTIVE SOLUTIONS AND INSTALLATIONS.

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Sustainable Retrofit A fabric first approach. Mark Elton Technical expert panel member Energy Saving Trust

COMP ONENT CATA LO GUE FOR B UILDING YO UR OWN HOME

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

SOLAR PHOTOVOLTAIC ENERGY

Construction Studies Theory - Higher Level

Passive House Object Documentation

Defining a Fabric Energy Efficiency Standard for zero carbon homes

D3.9_Overall Refurbishment Plan DRAFT CS03. Hotel Restaurant Valcanover

14.8 kwh/(m²a) Project Documentation. 1 Abstract. R-951 Residence: Three Family Passive House Building. 1.1 Data of building. Year of construction

Passivhaus Documentation

R-Matte Plus-3: Insulation for the Building Envelope

White Paper. Ultra Low Energy Houses. Frank Ermers Caroline Faasen Rudy Rooth KEMA Consulting December Energy Efficiency

APT building on Makartstrase, Linz AT

William Stanwix and Alex Sparrow. The. Hempcrete. Book Designing and building with hemp-lime. sample pages to show book layout and design only

Achieving the nearly zero energy building concept - A study based on practical experience

Demonstration building

SCANDINAVIAN HOMES LTD.

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

1 Insulation and Façade Systems Internal Insulation

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

Project Description. Projected build start date 03 May 2010 Projected date of occupation 06 Aug

The Nottingham Ecohome. Part L1 (2002) in existing dwellings

GREENHOUSE ENGINEERING PREFABRICATED HOUSES

Solar Home Design and Thermal Mass

URBAN REGENERATION OF A COMMUNITY IN MADRID MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017 MARIANN KRUUSE ALLAR ESKO

Project name Old Dover Road Project summary Whole house retrofit and formation of new habitable roof structure

ZEMedS: Implementation

Denby Dale Passivhaus

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Water control Vapor control and drying Room for growth

BPE Case study of Pippin Close and Barnlea Close

DESIGN SUMMARY: Shadow Trail. Passive Solar, Forest Meadow Home. Conceptual Drawings

A handbook of thermal bridging details incorporating Porotherm blocks

ENGINEERING AND CONSTRUCTION BRIEF REPORT. Áts Árpád Dudás Péter. Budapest University of Technology and Economics. Decathletes

LABC REGISTERED THERMAL SYSTEMS TO PART L

The Existing District for Tomorrow, a concept for quick and clean passive house renovation for mass housing in the Netherlands

Project Description. Projected build start date 10 Sep 2012 Projected date of occupation 03 May

LABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes

4. Insulation of external walls

Forty years of building physics research for what benefit?

School Tito Maccio Plauto Cesena (IT)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Exterior Perspective, East End

Transcription:

PROJECT SUMMARY Retrofit of a semi-detached house from the 50 s towards passive house standard. SPECIAL FEATURES Passive house standard Ecological design ARCHITECT Alexis Versele Architecten vennootschap OWNER Huyghe-Van Steeland Semi-detached house in De Pinte, Belgium IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation

he original front view of the dwelling he original back view of the dwelling BACKGROUND The owners of this half-open house from the 50ies wanted a healthy and low-energy house with lots of light and open space. But the search for an architect who could realize their dream house turned out to be difficult. When their first architect presented them the preliminary sketches of the future house, the design was severely over budget, while not fully taking into account a low-energy concept. So the owners decided to search an architect who already had experience with energy efficient buildings, and found this person in Alexis Versele Architects. After an initial interview and a visit to the house, the decision was made to renovate the property towards passive standard, and close to the postulated budget. The new design focused on sufficient insulation and airtight construction. Since the orientation of the building was far from ideal, the common wall being oriented south, window surfaces were designed to maximize the possible passive solar gains. New construction or renovation? One could argue that new construction towards passive house standards would have been preferred. Still, the decision was made to retrofit the building, because of: the excellent structure of the existing dwelling, consisting of 19cm thick concrete blocks which were still in excellent condition. Their thermal inertia was another plus. waste reduction, by reusing the existing materials. This was clearly a sustainable decision. the reduced VAT rate for retrofit of 6%, compared to the 21% rate for new construction. The original house The existing dwelling consisted of a main volume with a pitched roof, to which different constructions had been added according to the needs of the former inhabitants. As the common wall was almost perfectly oriented towards the south, this provided an extra challenge to reach passive house standard. The owners wanted a house with a lofty feeling, with lots of light and an open plan. This inspired the organization of the different functions: the bedrooms were placed on the ground floor, where natural light was less abundant. The living space and kitchen would take up the first floor. By raising the eaves and changing the pitch of the new roof, one big open space was created here, including a new mezzanine.

Before After SUMMARY OF THE RENOVATION Replacing the existing annexes by a new one resulting in an improved compactness (from 1,73m to 2,16m). Replacement of the worn out roof construction. Redesign of the layout and the circulation of the house. Removal of the exterior brick façade, replaced by a timber frame construction and filled with cellulose. Air tightness of 0,56 h -1. Mechanical ventilation with counter-flow heat exchanger. Ground/water heat exchanger. Flat plate solar collector. cross section, with old volume marked The original plans of the dwelling ground floor first floor mezzanine

Timber frame construction fixed to the existing wall. The originally wall was erected with concrete blocks, but during the retrofit and the adaptation of the windows some clay tile blocks were build in. CONSTRUCTION Roof construction (new) U-value: 0,12 W/(m² K) (top down) - Roof tiles 50 mm - Wood-fiber board 22 mm - Rafter + cellulose 82 mm - Wooden I-beams + cellulose 300 mm - OSB 15 mm - Lathwork 22 mm - Gypsum Fibreboard 12,5 mm Total 503,5 mm Wall construction U-value: 0,126 W/(m² K) (interior to exterior) - Interior plaster 15 mm - Concrete blocks 190 mm - Wooden I-beams + cellulose (new) 240 mm - Wood-fibre board (hardboard) (new) 18 mm - Wood-fibre board (soft board) (new) 60 mm - Exterior stucco (new) 20 mm Total 543 mm Floor construction U-value: 0,086 W/(m² K) (top down) - Linoleum (new) 6 mm - Screed (new) 70 mm - Phenolic rigid board insulation (new) 260 mm - Concrete slab 150 mm Total 486 mm

The house after dismantling the walls The construction of the common wall REPLACING THE OUTSIDE BRICK FACADE The old house was built with a traditional cavity wall construction, without insulation. After consultation with the contractor, the outside wall was removed, to be replaced by a timber frame construction fixed to the inner walls, containing the insulation layer. During construction, it became clear that the inner wall was far from straight. In some places a difference of 7 cm had to be gapped. REACHING PASSIVE HOUSE STANDARD The first PHPP calculation of the project underlined how big the challenge would be to reach passive standard. Following changes were made to the original design, in order to reach the target standard: The insulation layer in the walls was increased. The size of the windows was optimized, allowing for bigger windows at the back (west-side). The skylights and light tunnel on the east, originally planned, were deleted because they wouldn t deliver enough solar gains. The floor insulation type was changed towards a less ecological but higher performance material (26cm Phenolic rigid board in stead of cellulose) ENSURING AIR TIGHTNESS Because of the mixed structure of solid and timber construction, the connections between them were critical points. Special bands that can be plastered were used to make this connection. A first air tightness test showed an infiltration rate of 0,56 h-1 at 50 Pa pressure difference (n 50 ). The big leaks that remained were situated at the passage of the solar collector pipes through the roof (even thought they were taped off as good as possible), the passage of an old electricity cable in the old floor and the interruption of the stucco at the base of the wall in the corner between common wall and façade. Taping off the OSB boards, and connection between OSB and plaster on the brick walls (the white band in the upper photo)

Thermal break at the base of the walls Connection treshold with frontdoor. THERMAL BRIDGES AND SOLUTIONS Resolving the thermal bridges became an additional challenge, mainly because the starting point was an already existing structure. The most important connections were simulated. A classic thermal bridge when retrofitting is the base of the wall. Calculations showed its great impact. Because a moisture resisting barrier had to be installed anyway, it was decided to replace the first layer of bricks by cellular concrete. The joint between façade and common wall was another problematic connection. Here, no real solution was found, but adding an additional insulation layer on the inner wall at least greatly reduced the thermal bridging effect. Finally, the installation of the roof windows was studied. Because of their positioning outside of the roof construction, the thermal bridging effect was even greater. To reduce this, a second window was placed underneath the roof window. The roof windows and the solar thermal collector. Ψ < 0,01 W/mK Detail and thermal bridge simulation of the connection between façade and common wall Ψ < 0,01 W/mK Detail and thermal bridge simulation of the connection between roof window and inner window.

SUSTAINABLE MATERIALS For choosing the building materials, their ecological value was taken into account. FSC labeled timber was used for the timber frame construction. Cellulose insulation was used for the walls and roof. Only in the floor a chemical insulation material was used (Fenol-insulation). An interior plaster based on natural gypsum was used for the masonry walls. Cork and linoleum were applied as floor decking. A mineral stucco applied on a wood fiber insulation plate was used as an exterior finishing. A final aspect of sustainability is the reuse of rainwater. In front of the house a rain water tank of 5000l is placed. 2 toilets and a washing machine are connected to it. This way the use of tap water is reduced to a minimum. Mechanical ventilation unit. 1% 0% 2% 2% 0% 3% 4% 0% blowerdoor 1% demolition roof 9% 2% 13% 54% 2% 7% scaffold contractor carcass facade structure carcass contractor wooden structure and finishing EPDM Cellular glas Cork (incl. bathroom) Inner plaster Exterior stucco Water electricity An electrical resistance for post heating the living areas. Cost diagram COST ANALISYS The renovation to passive house standard was not evident. This translates into the cost of the project. This also reflects the unfavorable orientation of the dwelling, therefore additional insulation was needed. On the other hand, the reduced VAT rate, various grants and a federal tax deduction for retrofitting to passive house standard, make it all economically viable in times of high energy prices. CONCLUSIONS When the owners first formulated their dream of an ecological new home, their wishes were far from met. After having found an experienced architect, eager to realize their dream, the end result was a sustainable and ecological passive house retrofit. The project fully uses the existing potential of the building, and changes the rest for the better. The process was not an easy one though. Solving thermal bridges, incorporating air tightness solutions, developing an efficient ventilation strategy and last but not least keeping the budget within reasonable margins, required commitment and study work.

Front and rear view of the house; trees for natural shading Summary of U-values W/(m² K) RENEWABLE ENERGY USE Before After Roof 5,5 0,12 Walls 1,9 0,126 Basement ceiling 2,7 0,086 Windows * 5 0,74 BUILDING SERVICES Solar heating collector: flat plate collector, 8m² storage volume 300l ENERGY PERFORMANCE Space + water heating (primary energy)* Before: 450 kwh/m².a After: 67 kwh/m².a Reduction: 85 % * Flemish implementation of EPBD Mechanical ventilation system with a counter flow heat exchanger (η=84%). An electrical decentral post-heater (1200W) warms the ventilation air going to the living room. Additional electric heaters can heat the air going to the bedrooms as desired. In the bathroom an extra electrical heater is installed because of the higher comfort temperatures that are required there. To prevent overheating during the summer, screens are installed on all roof windows, as well as on the back windows on the first floor. 2 trees in front of the windows will provide sufficient shadow on the ground floor. Compact unit with heat pump and connected to the solar thermal collector, via a 300l buffer tank. This is used for the domestic warm water. INFORMATION SOURCES Alexis Versele Architecten, PHP vzw Brochure authors Wouter.Hilderson@passiefhuisplatform.be Johan.Cre@passiefhuisplatform.be This research was executed within the framework of the LEHR project (www.lehr.be), grouping three research teams (PHP/PMP, Architecture et Climat UCL, BBRI), on account of the Belgian Federal Science Policy, executing the Programme to stimulate knowledge transfer in areas of strategic importance.