Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference Large Meter Testing: Analysis and Calibration

Similar documents
OTCO 12/11/13 Water Audits Meter Testing & Leaks

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

Water Loss. Water Research Foundation How to use the Free Water Loss Audit Software v 5.0

The Changing Landscape and Business Case for Water Loss Control

Illinois Water Audit and Loss Control Training Workshop

Unit 3. Performance Indicators of Water Losses in Distribution System

Illinois Water Audit and Loss Control Training Workshop

Addressing Non-Revenue Water

Benchmarking Water Loss Performance: The Death of Unaccounted For Water

Impact of Large Meter Sizing on Unaccounted For Water. Presented by:

Water Audit and Water Loss Abatement Program

WATER LOSS CONTROL PROGRAMS

flow measurement Methods

Metering Simplified Ultrasonic Technology

City of Philadelphia Water Accountability Committee Fiscal Year 2012 Water Audit

A MODEL FOR THE NATION: Georgia s Statewide Water Loss Management Program

Commercial & Industrial Large Water Meters

Handling Fluid Fertilizers Selecting the Right Equipment Components

Implementation of Magnetic Meters for Irrigation Volumetric Measurement. Stuart W. Styles 1 and Lynn Groundwater 2

Solving the Mystery of Non-Revenue Water in High Point

Dale Barrie Training & Technical Assistance Specialist. Iowa Rural Water Association - Dale Barrie 1

Gwinnett County, Georgia Improves Meter Program Through Science and Strategy

Understanding Water Loss. Addressing Authorized /Unbilled Consumption and Apparent Water Loss

Water Conservation: Strategies, Pricing, Revenues

DRBC Water Conservation Program and Water Loss Accountability Rules

Water Accountability and Loss Control Improvements in North America: A Progress Report

The functional population of the Tampa

LIQUID PIPELINE FIELD OPERATIONS

WATER USES PROJECTED WATER USES THROUGH Table 4 2: 2015 Water Customers

Water Efficiency. Water Plant Operator. Association of Manitoba Municipalities Web:

CITY OF LAGRANGE, GEORGIA UTILITY DEPARTMENT WATER CONSERVATION AND DROUGHT CONTINGENCY PLANS

TWDB Description, Summary & Example of Agency Reports

Flow Meter Calibration

1. Trends in Water Metering 2. Good Revenue Vs Poor Revenue Meter 3. Developments in Metering Technology 4. Smart Metering

Table of Contents Part Title Page

Order to Talk. Water Measurement Techniques, Water Price and Water Fee collection. 1 Water Measurement Techniques

Choosing the Right Residential Water Metering Technology

Revenue Recovery Through Meter Replacement

Georgia Statewide Water Loss Program

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

C Addressing Non-Revenue Water with Static Meters. Martin Casillas Director of Sales, US West Kamstrup

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy

HX Performance Testing

4 PLANNING DATA AND WATER DEMAND FORECASTING

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology

Agricultural Pumping Efficiency Program. Flow Meters. Helping California Agriculture...

Innovative Wellhead Tools for Landfill Gas Management

Less Loss is our Gain Water Loss Control in Los Angeles

2016 Webinar Sponsors

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Will Jernigan, P.E., Chair Cavanaugh & Associates, P.A. Jason Bodwell Georgia Environmental Finance Authority. Dan Carter Eco-Tech Inc.

CA-NV AWWA Water Loss Technical Assistance Program Wave 4 Water Audit Level 1 Validation Document

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

MEASUREMENT OF AIRFLOW

Gary Fiselier Measurement Lead, EnCana Corporation

Challenges to Reduce Non-Revenue Water

ONTARIO CENTRE FOR MUNICIPAL BEST PRACTICES 200 University Ave., Suite 801, Toronto, Ontario, M5H 3C6. BEST PRACTICE SUMMARY REPORT February, 2008

Evaluation of Water Demand Management and Water Loss Control in Sanford, FL

EXHIBIT B. Notice of Non-Compliance

INTRODUCTION DATA COLLECTED WATER BILLING AND PRODUCTION DATA

"Effective Water Resource Management using Modern Metering Technology and Systems." 3 April 2013

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Implementing SB 555: Validated Water Loss Audits and Reporting

There are many technologies available for

Survey on the Techniques of Flow Measurement

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

Managing Losses in Water Distribution Networks

APlus-QMC LLC. Catalog 2017

The focus of this article is methodologies

VERIS Accelabar. Superior Flow Measurement Accuracy

The Paradigm Case Method of Flowmeter Selection

Investigation of Water Losses in Water Supply System: Muscat as a Case Study

lates.htm. LIST OF EXHIBITS

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

TABLE OF CONTENTS GENERAL INFORMATION OF KENT COUNTY WATER AUTHORITY BACKGROUND OFFICES OFFICE HOURS 1-1

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

Ice Rink Renovation & New Clubhouse

Experiences in DMA redesign at the Water Board of Lemesos, Cyprus

Using Advanced Metering Infrastructure to Control Water Loss

Distribution System Upgrades to Improve Water Quality

DEVELOPMENT OF A SUCCESSFUL UNTETHERED LEAK DETECTION AND PIPE WALL CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPELINES

ABB Measurement & Analytics Flowmeter technologies

DRINKING WATER LINE INSTALLATION STANDARDS

The Nexus of Leak Detection and Asset Management

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

ROCTEC Composite Carbide ABRASIVE WATERJET NOZZLES

Selecting the correct device for measurement control

Why Water Meters Matter The New York City Department of Environmental Protection s Operational Excellence Program (OpX)

Customer Metering Inaccuracies

DEPARTMENT OF PROCUREMENT SERVICES - CITY OF CHICAGO DECEMBER 9, 2013 ADDENDUM NO. 1 FOR METERS AND REPLACEMENT PARTS FOR WATER METERS

CHINO VALLEY FIRE DISTRICT FIRE PROTECTION STANDARD

Challenges associated with ballast water sampling for compliance verification and monitoring

GENERAL INFORMATION AND REQUIREMENTS

DEVELOPMENT OF A SUCCESSFUL INTERNAL LEAK DETECTION AND PIPELINE CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPES.

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

Non-Revenue Water Assessment

Redesigning Water Loss Standards in California Using the New IWA Methodology

Weholite LIGHTWEIGHT PIPE SYSTEM

Transcription:

Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference 2013 Large Meter Testing: Analysis and Calibration

Overview Water Loss Control Water Audit / Balance Format (AWWA/IWA) Apparent Losses Concentrating on Large Meter Testing (Master Meters) Concentrating on Large Meter Testing (Commercial/Industrial Meters)

Water Loss Control Monitoring water resources has been conducted for thousands of years. Julius Frontenus was first Roman Water Commissioner and recognized importance of equitable water distribution (300 BC) Concept of water rights and water use has been debated for centuries End result: majority of water is now metered

How much water are you really putting into the distribution system? INFLOW = METERED OUT + LEAKAGE

It s a Question of Balance Water Pumped Water Sold & Leakage

Water Loss Control The difference in the water pumped versus water sold is basically termed water loss Is it not possible to have a perfect system Concept of acceptable loss levels What is acceptable? How do you control losses?

Water Loss Control Water Loss Control is defined simply as the process of Auditing the operational procedures and processes of our water utility to determine losses and then provide remediation for those issues. IWA/AWWA developed a Water Balance chart after much research into differences in concept of water losses.

Start here Standard Water Balance Format Move this direction Own Sources Water Imported Total Total System System Input Input (allow ( allow for for known known errors) errors ) Water Exported Water Supplied Authorized Consumption Water Losses Billed Authorized Consumption Unbilled Authorized Consumption Apparent Losses Real Losses Revenue Water Non- Revenue Water Billed Water Exported Billed Metered Consumption Billed Unmetered Consumption Unbilled Metered Consumption Unbilled Unmetered Consumption Unauthorized Consumption Customer Metering & Data Inaccuracies Leakage on Mains Leakage on Service Lines (before the meter) Leakage & Overflows at Storage

Water systems are not designed to lose money! What is considered acceptable loss in a system? 10%, 15%,??? Why are these losses unacceptable? Law of diminishing returns Water Loss = $$ Money Loss

Master Meters - Determine Actual Production Test all production meters annually to determine the true volume of water being introduced into the distribution system Test all wholesale meters annually to determine the true volume of water being introduced into the distribution system

Why are Large Water Meters so important? Used for Billing in custody transfers Used to determine Chemical Feed Rates Used to account for the Total Volume of Water introduced into a distribution system Large Meters Are a Vital Component in any Distribution System

Meter Types Venturi Meters Orifice Plate Meters Magnetic Flow meters Propeller Meters Turbine Meters Sonic Flow meters Vortex Flow meters Averaging Pitot meters

Turbines Test Taps for comparative testing

Production Venturi Meter Production Mag Meter

New Venturi Meter ready to be installed Venturi Meters at High Service Pump Station

Large Meters are Prone to Failure for a variety of reasons Age Mechanical Wear and Tear Corrosion Mineral Buildup Fouling, due to debris Mis-Use, or operation outside of the meters range Inadequate Plumbing before and/or after the meter

What are the Consequences when these Meters Fail? Inaccurate Billing Lost Revenue Over and Under Feeding of Chemicals Inaccurate Annual Reports and Usage Estimates An Overall Loss of Control So What Can You Do?

Master Meter Test Standards M-6 manual addresses turbines and propeller meters but does not address Venturi meters or other types. M-33 doesn t state allowable accuracy levels (except to mention the manufacturer s specs)

Should they be removed and sent to a test facility?

Courtesy of Primary Flow Signal

Tank & Rotameter Test

Weighing Meter Test

It is best to test them In Place Advantages Practical - do not have to remove meter Test under conditions of current operation Able to inspect and assess flow conditions Disadvantages Meter may be in a compromised setting Test sites may be compromised Flows may be limited You have to settle for what is available/practical

Comparative Test

Flow Measurement Q = V * A Q V is Quantity of water is velocity of flow measured in ft / s A is inside Area of pipe in ft 2

Strap-On Flow Meters Doppler Meter Transit Time Meter

Q=VA Wall thickness Generally thickness gauges are used to determine Pipe Wall thickness Then ID of pipe is determined

Strap-On meters can be inaccurate. This is because the hydraulic conditions inside the pipe are often unknown.

Pitot Test

Pitot Testing can be done On-Site Pitot Testing is the most accurate portable testing method This form of Pitot tube was designed by Edward S. Cole in 1896.

Test Site Installation Pitot tap being installed inside the Plant Test site outside of the Plant, in trench

A Pitot Corp, Tapped Into Ductile-Iron Pipe

Using a Polcon Caliper to Measure the Inside Pipe Diameter

Positioning the Sensor in the Center of the Pipe Determine Position of Orifices (From Bottom of Pipe) Tape X Tape Tap X Tap

Flow conditioning Test sites need conditioned flow Meters need conditioned flow Site issues come into play such as straight runs of pipe, concrete pipe, valves, tees, elbows

Velocity Profile is Very Important Used to help calculate mean velocity of flow Used to see flow profile inside pipe

Common Velocity Profile Shapes FLOW FLOW BUTTERFLY VALVE PARTIALLY CLOSED GATE VALVE FLOW FLOW INCRUSTATION / TUBERCULATION BUILD-UP ON WALLS SMOOTH INTERIOR PIPE WALL

Water Loss Control Large Meter Testing and Repair Commercial & Industrial Customer Meters

Commercial and Industrial Meters High Revenue Meters Usually 10%-12% of the customers use 50% - 60% of the water. Test and repair industrial and commercial meters Replace obsolete meters

Common Meter Types Compound Meters Turbine Meters Displacement Metes Magnetic Flow Meters Propeller Meters Multi Jet Meters Single Jet Meters

Large Meter Testing Program Meter testing should be performed as on-going maintenance program An annual testing program will insure that revenues stay up Test meters within 6 months of installation 2 percent of annual revenue should be ear marked for meter testing

Testing Methodology Refer to the AWWA M-6 Manual Test specs are for meter test bench situations Field testing (testing meters on site ) requires following a strict methodology. **M-6 does not spell out field testing requirements. Refer to the meter manufacturer specs Newer style meters require different testing approach

Testing Methodology Calibrated test meter needs to be used AWWA requires tests at 3 flows Low, Intermediate, High flows In some cases testing may be limited by flow situation It makes sense to conduct several tests at different flows to get full assessment of meter s performance aside from the three tests. Look at how water is being used by water customer That will help in determining proper meter size and type. Refer to the M-22 Manual on Service line and Meter sizing.

Testing Frequency Is influenced by the cost of water as water costs increase more accounts require annual testing The water quality harsh water requires meters be tested more frequently

Using Revenue as a basis for testing frequency Using the rule of investing about 2% of a meter s annual revenue in the maintenance (testing) of that meter, the following averages apply. $15,000.00 or greater = annual testing $7,500.00 to $15,000.00 = every 2 years $3,750.00 to $7,500.00 = every 3 years Less than $3,7500.00 = every 4 years

Consequences of not maintaining meters These are your cash registers! (** Do you think it is ok to loose 10% - 20% of your money?) All your operating money comes from collecting the revenue generated by the meters! Make sure everyone pays for their fair share Sewer revenues often based on meter readings! (** Maybe you can get the sewer department to help fund the meter testing program!)

Case study Gwinnett County Department of Water Resources, Gwinnett County, Georgia 225,000 metered accounts, suburban area NE of Atlanta (2007) Pilot study with 36-3 and larger meters 26 testable, 23 failed, 10 untestable (no test ports, no isolation valves) 1 failed meter after replacement yielded a monthly revenue return of $ 38,000 ($456,000 annually!!!) This provided incentive to test and repair all 3 and larger meters

Case study Gwinnett County Department of Water Resources, Gwinnett County, Georgia 732 3 and larger meters inventoried and tested Initial program costs were estimated at approx. $850,000 Initial testing failure rate was 52% failure rate (Failed to meet suggested AWWA accuracy limits) 68 fireline meters were over 20 years old (past useful meter life) and had failed. Many meters in wrong applications.

Case study Gwinnett County Department of Water Resources, Gwinnett County, Georgia Initial program costs were estimated at $850,000 68 fireline meters slated for replacement at estimated cost of $1 million (average of $14,000 each) Assumed average large meter annual revenue of at least $14,400, the 68 meters replaced will pay for themselves in 1 year Estimated annualize revenue return for entire program projected to be slightly over $5 million. Net annual revenue return after testing, repairs and replacements projected to be $3.2 million.

Why develop a meter testing program? To insure that the utility is receiving all the revenue it should To promote conservation, reduce water loss and use best management practices To make sure that the cost of operating the utility is spread fair and equitably among all customers

THANK YOU!! A special thank you to the following people/entities who provided information: Gwinnett County, GA AWWA Water Loss Control Committee John Van Arsdel; Dan Hood; Aaron Horbovetz M.E. Simpson Co., Inc.

Presenter - Michael Simpson