Compact Waste Water Treatment MBR /MBBR Technology

Similar documents
Module 19 : Aerobic Secondary Treatment Of Wastewater. Lecture 24 : Aerobic Secondary Treatment Of Wastewater

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

19. AEROBIC SECONDARY TREATMENT OF WASTEWATER

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

FEASIBILITY REPORT OF 250 KLD SEWAGE TREATMENT PLANT

Feasibility Report on Sewage Treatment Plant (STP)

CORPORATION THE EXPERIENCED LEADER IN SEQUENCING BATCH REACTOR TECHNOLOGY

TECHNICAL BROCHURE WASTEWATER TREATMENT SYSTEMS

ISAM INTEGRATED SURGE ANOXIC MIX

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

EVW 2 Hynds Commercial Wastewater Systems April 2013

Advantages & Applications of MBBR Technologies

Duffin Creek Water Pollution Control Plant Technical Information

Proprietary AquaTron technology incorporates three (3) innovative features that increase its efficiency and reduces cost:

SEWAGE TREATMENT PLANT TECHNOLOGY BY COMPLETE WATER SOLUTION BHALERAO HEIGHTS, AKURDI, PUNE

Turbo4bio System For the Treatment of Sewage & Organic Effluents

Feasibility Report of Proposed ETP cum STP. M/s. Zakiya Healthcare Plot No.39, Pharmacity Selaqui, Dehradun (Uttarakhand)

COMPACT PLANTS FOR MUNICIPAL WASTEWATER TREATMENT

Waste water treatment

CLR Process. Vertical Loop Configuration

Appendix B-1. Design Calculations for Sewage Treatment Plant

CORPORATION THE EXPERIENCED LEADER IN SEQUENCING BATCH REACTOR TECHNOLOGY

Dr Martin Peter *, Joachim Scholz & Victor Ferre. Contents

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

FEASIBILITY REPORT ON SEWAGE TREATMENT PLANT ARCHITECTS PHE CONSULTANTS

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

The Membrane Wastewater Treatment Plant in Ihn Layman s report

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Sludge recycling (optional) Figure Aerobic lagoon

North Side WRP Master Plan Research and Development Department 2006 Seminar Series October 27, 2006 Metropolitan Water Reclamation District of

Oxidation Ditch Technologies

American Water College 2010

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

Tour of Regional Water Reclamation Facility

Global Leaders in Biological Wastewater Treatment

Activated Sludge Base Notes: for student. Activated Sludge Intro. What is Activated Sludge? 3/12/2012

Upgrade of an Oxidation Ditch Using Bio-Mass Carriers

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

Description of the Work

Oxidation Ditch Technologies WATER TECHNOLOGIES

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Assuming 100 gallons per capita per day, and 3 people per REU, design flows for the development are proposed to be:

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

BIO-BATCH TM. Sequencing Batch Reactor (SBR) Water & Wastewater Treatment

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

Module 17: The Activated Sludge Process - Part III Answer Key

COMBI-TREAT IMPROVED SBR TECHNOLOGY. 2.1Process Diagram:

KUBOTA Submerged Membrane Unit for MBR Technologies

Sanitary and Environmental Engineering I (4 th Year Civil)

Treatment Systems How they work and what to consider when selecting one. Joe Walsh IOWA Conference 2015

Membrane BioReactor: Technology for Waste Water Reclamation

BIOSPHERE MOVING BED BIOLOGICAL SYSTEMS

a) Biological Oxygen Demand b) Biology Oxygen Demand c) Biochemical Oxygen Demand d) Biomicrobics Oxygen Demand

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng

membrane bioreactors MBR vs. Conventional Activated Sludge Systems CAS

1/11/2016. Types and Characteristics of Microorganisms. Topic VI: Biological Treatment Processes. Learning Objectives:

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

EfloSAF. Eflo. General Description. - About Us

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

Long-Term Activated Sludge Treatment in MBR for Industrial Wastewater Treatment

Containerized Ultrafiltration (UF) Water Treatment Plant

Palmer Wastewater Treatment Plant Environmental Impacts. A summary of the impacts of this treatment alternative are listed below:

SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES

AquaNereda Aerobic Granular Sludge Technology

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

THE FRIENDLY TO KEEP OUR WORLD CLEANS

Lagoons Operation and Management in New Brunswick

EnviroServer Extended Storage Owners Manual

Packaged Wastewater Treatment Systems for Individual Homes and Small Communities. Mark Gross Orenco Systems, Inc. Sutherlin, OR USA.

IMPROVED BIO-TOWER TECHNOLOGY MUNICIPAL SEWAGE TREATMENT

Sequence Batch Reactor A New Technology in Waste Water Treatment

CTB3365x Introduction to Water Treatment

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l

Severn Trent Services Wastewater Solutions End-to-End Wastewater Treatment Solutions

Attachment N o F Control & Monitoring

MEMBRANE BIO-REACTOR. Prashanth N 1 1. INTRODUCION

EHS SMART-Treat Onsite Moving Media Treatment System

Waste Water Treatment Equipment

American Water College 2010

Full Scale Testing to Demonstrate Anaerobic Selector Effect for Low Strength Wastewater

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

/ Marley MARPAK Modular Biomedia /

Error! Bookmark not defined.

UPGRADING FOR TOTAL NITROGEN REMOVAL WITH A POROUS MEDIA IFAS SYSTEM

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

Evaluation of Conventional Activated Sludge Compared to Membrane Bioreactors

2017 Annual Performance Report

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

SECTION 2.0 WASTEWATER TREATMENT PLANT AND DISPOSAL SYSTEM DESCRIPTION

RESTRICTED URBAN REUSE OF KONYA (TURKEY) MUNICIPAL WASTEWATER TREATMENT PLANT EFFLUENTS VIA RECLAIMED WATER DISTRIBUTION SYSTEM

AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) and Integrated Fixed-Film Activated Sludge (IFAS)

WPL Diamond. Environmental Wastewater Solutions. EN approval Compact design No odours. Low visual impact Easy to install

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

Transcription:

Compact Waste Water Treatment MBR /MBBR Technology 1 Minimal Operation and Maintenance Costs and use of Chemicals 2 Recycle and Reuse water for Irrigation and Recreation 3 Save Water, Energy, Money and Conserve the Environment 4 SUSTAINABLE WATER SOLUTIONS

W ATER ENGINEERING MBR /MBBR STP Process Flow Scheme Water Engineering Packaged Water MBBR Treatment Sy stems are state of the art yet affordable plants which are capable of giving excellent quality Treated sewage on small footprint Raw Wastewater Feed Pumps Air Blowers and Coarse Bubble Diffusers for Equalization/Sludge Tank (Optional) The System is a Combination of the Fixed Film and Activated Sludge Process, Activate Sludge has process stability and provides a high degree of treatment and Fi xed Film Processes are inherently stable and resistant to organic and hydraulic shock loadings. Electromagnetic Flow Meters at Inlet of STP Manual Coarse Screen, Bar Type, 10 mm Aeration Tanks with Coarse Bubble Diffusers and Air Piping By incorporating Activated Sludge Recirculation (RAS) hi gher high quality Biomass can be maintained. This makes the Process more stable, more responsive to load fl uctuations and provides better oxygen diffusion, mixing and energy efficiency then conventional MBBR. Design Basis Bio Media inside Aeration Tank Air Blowers for Aeration Tanks Sludge Recirculation/Waste Pumps Motorized Valves for Sludge Wasting PH 7.0-8.5 Settling Tank with Tube Deck Media BOD (mg/l) 300-350 mg/l Sodium Hypochlorite Disinfection System COD (mg/l) Suspended solids (mg/l) 400-600 mg/l 300-400 mg/l Manual/Automatic Multi Media Filter Ammonical Nitrogen 40-50 mg/l Filter Feed Pumps Treated Effluent Quality Backwash Pumps BOD < 15 mg/l COD < 100 mg/l Suspended solids < 15 mg/l Electrical Control Panel, Form 2 Internal and external Interconnecting Piping and accessories SUSTAINABLE WATER SOLUTIONS

PROCESS FLOW SCHEME OF STP Air Blowers Equalization Tank Wastewater Feed Pumps Mancial Caorse Screen MBBR Tank Ae ration + Nitrification + Settling (Compartments) Recirculation /Waste Sludge Pump Storage Tank Chlorine Contact Tank Sewage Collection Tank Backwash Pumps Chlorine Dosing P Treated Sewage Tank Multi Media Filters Filter Feed Pumps Salient Features Factory made plug and play system with small footprint. MLSS Concentrations of 2000-3000 mg/l which increases SRT resulting in better biology and performance. Reduction in sludge production and less sludge needs to be wasted compared to Conventional MBBR. Safe HRT enabling stable and sustainable Biology and better Aeration and Nitrification. Using very conservative surface area loading rates for the Biomedia thereby ensuring design for peak flows. Positive Displacement Blowers for Aeration instead of Side Channel Blower which are better in quality and long lasting. Coarse Bubble Differs for Aeration specially designed to ensure the swirling action to keep Bio Media in suspension. State of the art Bio Media from GEA Germany which creates the perfect environment for bacteria SUSTAINABLE WATER SOLUTIONS

Model No. *Capacity (m3/d) Population (persons) Inlet (BOD/TSS) Outlet (BOD/TSS) Tank Dimensions Multi Media Filter Diameter WMBR 100 100 500 300/400 15/15 4.5 m * 2.5 m * 3.5 m 30 Inch WMBR 150 150 750 300/400 15/15 6.3 m * 2.5 m * 3.5 m 36 Inch WMBR 200 200 1000 300/400 15/15 8.2 m * 2.5 m * 3.5 m 42 Inch WMBR 250 250 1250 300/400 15/15 10.1 m * 2.5 m * 3.5 m 48 Inch WMBR 300 300 1500 300/400 15/15 12.0 m * 2.5 m * 3.5 m 48 Inch WMBR 350 350 1750 300/400 15/15 12.0 m * 3.0 m * 3.5 m 63 Inch *Calculations are based on discharge of 200 liters of Wastewater per person per day. If bigger capacity is required than the standard modules can be added in parallel A ISO 9001:2008 Company

STP HS 0.5B Wastewater Treatment Systems with Nutrient(N,P)Removal Hydraulic loading:500l/day Influent Flow rate adjustment 1st Anaerobic /Primary settlement Clarification Electrodes for P removal (Optional) Bio-film filtration 2nd Anaerobic Flow Rate Adjustment Area Flow rate adjustment device Aerobic Outlet pipe Backwash Tank(DCPD) Aeration A su ir pp ly Bio-film filtration Air blow er Phosphorus removal area Backwash Clarification Washing Aeration 1st Anaerobic Reccirculation Disinfection Mixing Access cover Flow rate Control Inlet pipe Disinfection area 2nd Anaerobic Effluent /Primary settlement Advanced Performance 优点 Nitrogen removal The systems are designed for installations in environmentally sensitive area and the effluent can meet: COD 60mg/L SS 20mg/L TN 15mg/L TP 1mg/L NH 3 -N 8mg/L In anaerobic s, nitrogen-removing microorganisms grow on the surface of filter media. The microorganisms convert nitrates in the recirculated water coming from the aerobic to nitrogen gas which returns to the atmosphere without causing any harm. Phosphorus removal Automatic backwash Automatic backwash controlled by timer ensures: Through electrolytic process of electrodes in the wastewater, phosphate is generated and precipitated, thus removing phosphorus. The water washes the surface of electrodes, further stabilizing P removal. stable and highly efficient treatment performance automatically controlling the thickness of bio-film on the filter media better nitrogen and SS removal the filter media not clogging Flow rate adjustment Combined with airlift pump and overflow weir, flow rate adjustment device easily controls the volume of both effluent water and re-circulated water.

Details of the systems Model 1st anaerobic /Primary settlement Effective volume m 3 2nd anaerobic Aerobic chambe Clarification Dimension mm Total volume m3 length width height Inlet invert depth (mm) Outlet invert Weight to base (Kg) (mm) Air blowers Power W(50Hz) Airflow L/min DSP-SH-05B 0.334 0.371 0.284 0.112 1.437 1672 972 1477 360 370 250 30 40 600 Diameter of access cover (mm) Warranty 15 years for tank, 2 years for electrical components Structure diagram 5m3/day Package MBBR plant A ISO 9001:2008 Company