PRODUCT RANGE JUNE 2018

Similar documents
product range HAMPTON LONSDALE BRIGHTON COVE BLACKWOOD MCLAREN SORRENTO E:

Galintel RETAINING WALL POST. Installation Guide. The Galintel brand is proudly owned by

SPECIFICATION FOR REINFORCED SOIL WALL

Gardenstone Retaining Walls

Reinforced Earth wall Construction Manual

CHAPTER 13 - MECHANICALLY STABILIZED EARTH WALLS AND PATENTED EARTH RETAINING SYSTEMS

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

Heron Retaining Walls

Palm Retaining Walls. masonry. build in style

LANDSCAPE RETAINING WALLS

IRONWOOD SLEEPERS QUICK GUIDE

Gravity Wall. A force to be reckoned with... Gravity (SRW) segmental retaining wall systems are structures

Rapid Ply versatile, modular formwork

CF50/100 KW TURBINE ACCESS ROAD, CRANE PLATFORM, CONCRETE, AND LIFTING SPECIFICATIONS C&F GREEN ENERGY REVISION PREPARED BY APPROVED BY DATE

Dock shelter and dock seal Full choice of dock shelters and dock seals can be included, refer to Stertil Stokvis brochure.

Specification & Procurement Guide ATG SP100 Lift-Assist Bollard

Retaining Walls. Made Easy

SureWall Post & staking systems provide a simple and easy solution for transforming timber sleepers into garden retaining walls.

BACKYARD BLOCK australianpaving.com.au

Retaining Wall System

Each warehouse has its specific requirements that must be assessed in order to obtain the best results. Analysis required in terms of the following:

CONSTRUCTION SPECIFICATION FOR CONCRETE BARRIERS

INFORMATION KIT 2018 COPYRIGHT 2018 PENTABLOCK WORLWIDE PTY LTD

PENTABLOCK Technical Information 190mm Series

Installation Manual. ArchCast Bridge. 3-Sided Precast Concrete Bridge Structure

PISA. Retaining Wall System. The choice of professional contractors

Fence Stone. Self locating Wall System

Strengthened Soil Wall Construction Manual

AUGUST 2017 HASTINGS. retaining walls installation guide

Self Locating Wall System

CONSTRUCTION SPECIFICATION FOR CONCRETE UNIT PAVERS

Installation Instructions for Circular Trench Pipes (DN300 DN1200) PD 46 rev D October 2013

Evaluation Report CCMC R Superior Walls Xi Precast Concrete Insulated Wall Panels

Complete Modern Drainage System

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

Construction Specification for Concrete Curb and Concrete Curb and Gutter

WATER AND DRAINAGE. Drainage Around Walls Water Applications Drainage Structures Water and Drainage Q & A

Verti-Block Design Manual Section 1 - Gravity Wall (Standard)

Applications. 5 reasons why you should choose Hebden X Grid cellular paving

Five Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight

Retaining Wall Products

Construction Specification for Concrete Unit Pavers

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

component developments Stainless Steel Industrial Floor Drainage

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03

Shore Steel Trench Boxes & Manhole

Redi Rock Specification and Installation Manual

MassBloc Retaining Wall EARTH RETENTION

BELMURO WALL SYSTEM INSTALLATION GUIDE

T-WALL Retaining Wall System

EVOLUTION. Product Data Sheet. Design Wall Series

CONSTRUCTION SPECIFICATION FOR CONCRETE CROSSWALK INDEX TS SCOPE...3

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

Garden WallScape Installation Guide

Core. Thickness. Biological

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK AND CONCRETE RAISED MEDIAN INDEX TS SCOPE...3 TS DEFINITIONS...3

HC-Omega (Sinus Slide ) armour joints

NOVEMBER 2016 MAGNUMSTONE. retaining walls installation manual

Limelight Pulse Spa Installation Instructions

Secura Grand Slate Lidl, Wembley

GRANDE WALL large CONCRETE BLOCKS FOR THE CONSTRUCTION OF RETAINING WALLS. 1339_Feuillet_Permacon_Grande_ang.indd 1

Acoustic boundary walls & fencing

VERTI-BLOCK - DESIGN MANUAL

BlazeBrake. Fire Protection Systems. Retrofit Fire Rated Devices for Cable & Pipe Services

Retaining Guide. TerraFirm mm. 750mm (typical)

Acoustic boundary walls & fencing

CONSTRUCTION SPECIFICATION FOR PIPE SUBDRAINS

Tasman Retaining Wall System

Tasman and Norfolk Retaining Wall

freestone eco Prestige & quality DIY vertical wall Large blocks - 10/m 2 Smooth surface finish No concrete footings

8.8 M10/15x90 50Nm. Zinc plated. Mechanically galvanised. PSA anchor. heavy duty vibration resistant removable

G R A V I T Y / G E O G R I D

SAFE WORK PROCEDURE 038 PIT CONSTRUCTION MARCH 2014 DOC. NO. D14/184671

GreenLock L9 Heavy Duty Retaining Wall Block (RWB) Features and advantages of the L9 retaining wall block

Water Control Structures Selected Design Guidelines Alberta Environment Page 24-1

CONSTRUCTION SPECIFICATION FOR PIPE SUBDRAINS

Welcome: What is U-Drain? Drain Materials. Flow

INSTALLATION GUIDE A Unique Retaining Wall System That s Engineered to Last!

Special Provision No. 405F03 March 2005

CONSTRUCTION MANUAL. T-WALL Retaining Wall System FOR RAILROAD PROJECTS. The T-WALL Solution...

Cooke Precast Concrete

Bridge Installation Guide

Network Access Chamber Systems

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

Construction Specification for Utility Adjustments

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

SAFE WORK PROCEDURE 041 CONCRETE WORKS SEPTEMBER 2014 DOC. NO. D14/265945

MagnumStone Specifications Gravity

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

ACO Building Drainage

Special Provision No. 599S22 March 2018 REQUIREMENTS FOR RETAINED SOIL SYSTEMS (RSS)

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

SigmaJoint. The Ultimate Joint J. Armouring & Load Transfer Systems. Metallic Leave-In-Place Contraction & Day Joints for INDUSTRIAL CONCRETE FLOORS

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

Tasman Retaining Wall System

NRDCA 175 GUIDELINE FOR FIELD APPLICATION of CELLULAR INSULATING CONCRETE ROOF DECK SYSTEMS

Transcription:

PRODUCT RANGE JUNE 2018

2 PRODUCT RANGE RETAINING WALL SLEEPERS LONSDALE BLACKWOOD

PRODUCT RANGE 3 RETAINING WALL SLEEPERS COVE MCLAREN

4 PRODUCT RANGE RETAINING WALL SLEEPERS ASHWOOD KENSINGTON

PRODUCT RANGE RETAINING WALL SLEEPERS BRIGHTON 5 SORRENTO

6 PRODUCT RANGE Step treads / Lifting Grab STEP TREADS Create steps with our matching sleeper treads. Available in Lonsdale and Blackwood SLEEPER GRAB Efficiently install sleepers with minimal effort Safe handling with reduced fatigue and injury Massively reduced labour costs Fits most machinery with 300kg load capacity

PRODUCT RANGE SLEEPER INSTALLATION GUIDE 7 TYPICAL SLEEPER ARRANGEMENT 1 STRING LINE STANDARD PRODUCT STANDARD PRODUCT 4m HEAVY DUTY PRODUCT EXTRA HEAVY DUTY PRODUCT 4m HEAVY DUTY PRODUCT EXTRA HEAVY DUTY PRODUCT Set pegs at each end of the retaining wall site and connect with a string line to give the required alignment. Holes should be dug at 2015mm centres for 2.0m sleepers and 2415mm centres for 2.4m sleepers. 3m 2.4m A similar allowance of 15mm can be used for other lengths. Hole diameter must be at least 450mm for a one metre high retaining wall. If your wall is over one metre high you will need council permission and engineers advice. 1.6m 1.4m PEG SLEEPER LENGTH + 15mm STRING LINE SLEEPER LENGTH + 15mm PEG 2 metre sleeper 2.4 metre sleeper 450mm 450mm 450mm 2 POST HOLES The post holes for a typical 1.0m high wall must be dug at minimum 1100mm deep, and 450mm in diameter. For higher walls, and where permits and council regulations apply, holes will typically be larger, please check with relevant authorities. 1000mm GROUND LEVEL 1000mm 3 STEEL PLACEMENT Place steel into recommended size hole, and set at 15mm longer than the sleeper being installed. For example, if you are using a 2.0m sleeper then space the steel uprights at 2015mm inside the channels. Timber props are a good idea at this stage to ensure correct spacing of steel. Ensure the steel is square and straight using level or laser. Once steel is in place, pour concrete into hole ensuring it is covered on all sides and underneath steel by at least 100mm. DO NOT OVER FILL HOLES. Typically concrete should finish at least 10mm below base of bottom of sleeper. 100mm Pad SLEEPER LENGTH + 15mm SLEEPER LENGTH + 15mm 4 SLEEPERS 5 DRAINAGE After the concrete has cured, place first sleeper between steel posts. Use packing to adjust level, ensuring each layer is the same distance down from top of steel posts. It is good practice to insert wedges behind each sleeper to guarantee each is held to the front of the steel post. Total Wall Height wedge packers packers Total Wall Height Once sleepers have been installed, place plastic membrane behind wall and slotted drain along length running to a discharge point. Cover drain and backfill with 20mm scoria up the height of the wall. Ensure there is no compaction behind wall to a distance of 75% of wall height. Example, if your wall is 800mm high, then no compaction within 600mm of back edge of wall. Plastic Membrane Front of Sleeper 20mm SCORIA Front of Sleeper Drainage Pipe Sleeper Wall Note: Please ensure that during installation no equipment is driven over the wall backfill within 75% of the wall height. Compaction if any, within this area should be with non vibrating hand equipment weighing no more than 500kg per square metre of footprint. If greater compaction is required please obtain engineering advice. Wall designs shown are for typical soil conditions. Calculations are available on our website. For walls over 1 metre you should seek independent engineering advice based on your specific site conditions.

8 PRODUCT RANGE RETAINING WALL PANELS LONSDALE brighton BLACKWOOD

PRODUCT RANGE RETAINING WALL PANELS 9 Height of wall HD Sleeper 2000 x 200 x 100mm x 2 x N10 PANEL A+ 2000 x 800 x 100mm 4 x N16 / 2 x N10 PANEL B+ 2000 x 800 x 120mm 4 x N16 / 2 x N10 PANEL C+ 2000 x 800 x 150mm 6 x N16 / 2 x N10 800mm 0 1 N/A N/A 1000mm 1 1 N/A N/A 1200mm 2 1 N/A N/A 1400mm 3 1 N/A N/A 1600mm 0 2 N/A N/A 1800mm 1 2 N/A N/A 2000mm 2 2 N/A N/A 2200mm 3 2 N/A N/A 2400mm 0 2 1 N/A 2600mm 1 2 1 N/A 2800mm 2 2 1 N/A 3000mm 3 2 1 N/A 3200mm 0 2 2 N/A 3400mm 1 2 2 N/A 3600mm 2 2 2 N/A 3800mm 3 2 2 0 4000mm 0 2 2 1 4200mm 1 2 2 1 4400mm 2 2 2 1 4600mm 3 2 2 1 SLEEPERS PLACED ON TOP OF WALL 200mm HD SLEEPER 800mm 800mm 800mm 800mm 800mm PANEL A+ PANEL A+ PANEL B+ PANEL B+ PANEL C+ 4200mm

10 PRODUCT RANGE STEEL 100UC available in selected sizes H section and C section Hot dipped galvanized for longer life span

OUR PREMISES 11 FACTORY Purpose built facility Technologically advanced for superior quality control Large production capabilities for quick turnaround times. DELIVERY Dedicated delivery vehicle Small delivery windows to avoid downtime Forklift for difficult site access and exact stock positioning Large load capacity for commercial customers Smaller crane trucks available on request Metro and country delivery available Pick up with vehicles suitable for forklift loading welcome

ADDING DISTINCTION TO YOUR LANDSCAPE DESIGN. Outback Sleepers offer the highest quality concrete retaining wall sleepers and precast panels, engineered to achieve wall heights in excess of 4 metres. From larger civil works projects, to landscaping works, and small retaining walls, we have designs to suit every taste and budget. As a local manufacturer we offer fast turnaround, large quantities of stock, and an efficient delivery service to site. With a network of long term valued contractors, Outback Sleepers have the industry reputation to match and can recommend wall builders suitable for any installation. Contact us today and our expert team will be happy to assist with your installation or delivery enquiries. WALL DESIGN STANDARDS For all wall construction and permit requirements, please contact your local authority for details. Typically, walls under 1.0m do not require permits, but may still need to be engineered depending on location. Our sleepers have local 1507 building code certification and are designed according to AS 3600-2009 which provides for a minimum 50 year life span. SLEEPER SIZES 2.0m x 200mm x 75mm Standard 2.0m x 200mm x 100mm Heavy Duty 2.0m x 200mm x 120mm Extra Heavy Duty 2.4m x 200mm x 80mm Standard 2.4m x 200mm x 100mm Heavy Duty 2.4m x 200mm x 130mm Extra Heavy Duty 3.0m x 200mm x 110mm Heavy Duty Colours may vary marginally to this brochure. Not all designs available in all sizes. Please check availability at time of purchase. Thicknesses may vary with a tolerance of +3mm/ - 1mm. As with all concrete products, sleepers are subject to efflorescence and water staining. Our products are delivered in plastic wrapping. To maintain optimum colour uniformity of charcoal coloured products, we would recommend plastic covering for 2 weeks if rain is likely. VICTORIA NEW SOUTH WALES 63-65 Ordish Road Dandenong South VIC 3175 Tel: (02) 8318 1449